Digital amplifier for proportional valves PEM XD

Similar documents
EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

ELECTRONIC REGULATOR FOR OPEN LOOP

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Continental Hydraulics Installation Manual CEM-PA-A

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Electronic amplifier type EV1D

Continental Hydraulics Installation Manual CEM-RA-A

Proportional Directional Control Valves Nominal sizes 16 and 25

RT-5005/5006/5007/5008

Technical Documentation

DENISON HYDRAULICS Proportional Pressure Control Valves

Analog amplifier RA. RE Edition: Replaces:

Proportional Directional Control Valves Size 6

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Drive Electronics pq11

Electronic regulator for PWM controlled proportional solenoid valves FABER -

Drive electronics pq11

Technical Documentation PAM-190-P

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment

Proportional Directional Control Valves Size 6

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Accessories Power Amplifiers

TECHNICAL DATASHEET #TDAX022420

W.E.ST. Elektronik GmbH

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Valve amplifier for proportional pressure valves

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Digital Function Generator

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Technical Documentation MOT-114-P

RT100 Multi-axis Joystick Controller. RunnTech

Model 805 PWM Proportional Valve / Solenoid Driver with Peak and Hold Control Modes

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

Electronically controlled proportional pressure regulating valves

400 (±2,5 V/ V/ ,3% V4A

Proportional amplifier type EV1M3

TxBlock-USB Transmitter

OVEN INDUSTRIES, INC. Model 5C7-362

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 12 VDC

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Valve amplifier for proportional valves with electrical position feedback

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

with Electronic Assistant

Strain Gauge Measuring Amplifier BA 662

Proportional amplifier type EV22K5

Programmable with Electronic Assistant Simulink

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Ordering Part Numbers: SAE J1939 version Controller: AX022400

Digital Interface Card DEC005000

Industrial motor controller for brushed DC motors 24 VDC

RT200 Series Single-axis Industrial Joystick. RunnTech

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Electric amplifier for flow control with proportional

TECHNICAL DATASHEET #TDAX INPUT, 12 OUTPUT VALVE CONTROLLER,

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Totalizing Counters mini-i

ISOMETER IRDH575. Approvals

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Pulse Scaler for DIN Rail Attachment

Overview. Features. Specifications. Important Notes

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

Tarocco Closed Loop Motor Controller

RA / /6. Replaces: Table of contents RA /06.98

MDSD (Series 2X) Mobile Dual Solenoid Driver

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

DEIF A/S. Insulation monitor. Type SIM-Q

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

LVDT. Inductive Position Transducer. SL Series. Key-Features:

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

Applications: Off-highway construction equipment Municipal vehicles Material handling equipment (forklifts, etc.) Ordering Part Numbers:

EMA Series, EMC Series

NX Series Inverters. HVAC Pocket Programming Guide

Electric amplifier for proportional cartridge throttle valves

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

Analog Servo Drive 25A20DD

2/2 way Proportional Valve (motordriven)

YVPC ELECTRONIC REGULATOR FOR PWM CONTROLLED SOLENOID

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Technical data. General specifications. Measurement range min max. 360

Analog Servo Drive 20A20

User Manual. Proportional Directional Control Valve PRM7

Amplifier / controller electronics

Sealed Interface Control: EC20300

Torque Sensor Series 3000 and Series 4000

Transcription:

Digital amplifier for proportional valves PEM XD FEATURES - Amplifier for cap rail mounting according to DIN EN 50022 - Control of 2 coils in open loop, or 2 proportional valves with 1 coil in open loop - Linear control with minimal hysteresis SPECIFICATIONS Electric supply*: DC 10-30 VDC (rectified and filtered, small ripple) * shall be > than voltage of coils 20 up to max. 40 W 860 ma 2600 ma Power: Output: Setpoint signal: - tension ±10V Input impedance 10-100 kω - current 4 up to 20 ma Input impedance max 500 Ω Card connector: DIN 41612-D 32 drill Ambient temperature: -20 up to 70 C Electro-magnetic capability (EMC): - Output according to CEI EN 61000-6-4 - capability according to CEI EN 61000-6-2 according to standards 2004/108/CEE Protection: Weight: Measures: Fixation: Supply: Over-voltage- and Inverse polarity protection Signal entry: (> 33 V) inverse polarity protect. Coil output: over-voltage protection 0,15 kg 120 x 93 x 23 mm cap rail DIN 50022, terminal strip 15 poles Signals A1 Setpoint 1 < 3,5A Block diagram A2 Setpoint 2 < 3,5A A3 Short circuit at port 1 A4 Short circuit at port 2 A5 Disconnection at port 1 A6 Disconnection at port 2 Parameters for PEM-XD-Dx2x A7 Supply voltage < 10V Annotation: if the reason for the failure is corrected the display is automatically deleted E 5.249.2.0 /01.13

1 - FEATURES 1.1 - Supply The amplifier requires a power supply of 10 to 30 VDC (terminals 1 and 2). Note: The supply voltage of the amplifier may not be lower than the operating voltage of the controlled solenoids. The voltage must be rectified and filtered, and the max. allowable ripple must be above the voltage range. The performance of the amplifier depends on the supply voltage and the value of the highest current. In general, a safe value for estimating the required performance results from the product of V x I. For example, an amplifier with maximum solenoid current = 800 ma and a supply voltage of 24 Vdc has a power consumption of 20W. 1.2 - Electrical protection devices The input power of the amplifier is equipped with an overvoltage and reverse polarity protection. The outputs have a short circuit protection. 1.3 - Setpoint signal The amplifier is designed for input setpoint values in the form of voltage signals 0 and 10 V and ± 10V and current signals of 20 ma. The setpoint values come from an exterior generator (PLC, CNC) or from an external potentiometer, which is supplied with the amplifier. 2 - STATUSMELDUNGEN 2.1 - Power ON The two-character display issues a confirmation of the power supply to the amplifier: ON - Supply ok. OFF - no or insufficient supply FLASHING - error message (see table 1) The number of the displayed variables is depending on the version of the amplifier (see model code): U1: setpoint of Channel 1:..0V 9.9 V at version D01x 4mA to 20mA version D11x.. - 9.9 V. V..0. +9.9 V for version D02x..4mA 12mA 20mA at version D12x C1: Nominal current for channel 1. Calculated from the setpoint signal. Displayed in amperes in the range of 0A to 3.0 A. E1: Actual current for channel 1. Measured actual current value. Displayed in amperes in the range of 0A to 3.0 A. U2: Setpoint signal of channel 2: 0V.. 9.9 V at version D03x 4mA to 20mA version D13x.. - 9.9 V. V..0. +9.9 V for version D02x. 4mA 12mA 20mA at version D12x C1: Nominal current for channel 2. Calculated from the setpoint. Displayed in amperes in the range of 0A to 3.0 A. E1: Actual current for channel 2. Measured actual current value. Displayed in amperes in 0A to 3.0 A. In version Dx1x, only the variables U1, C1 and E1 are foreseen for display. The indicated value should be interpreted as described below. E.g. version D12x. Setpoint signal 4.2 - Card OK OUTPUT If no error is present, there is voltage at Pin 9. The output voltage signal corresponds to the supply voltage, if not even detected as defective (<10V). As a reference point, the ground pin 15 may be used. In case of failures the output it set to 0V. The following failures are recognized: - Supply voltage <10V - Short circuit - No coil connected In the case of a failure the output amplifier ports are disabled. After eliminating the interference the output ports are automatically reset. The output current shall not exceed 100mA. 3 - Settings Two modes of operation have to be distinguished: display of variables and modification of parameters. The display of variables allows a real-time control of the setpoint and actual point state of the current and voltage values. The second mode enables editing and adjustment of various operating parameters. 3.1 - Variable display After switching-on the amplifier starts in the variable display mode and shows the value of the first variable, i.e. U1 = setpoint signal of Channel 1. By the buttons (+) and (-) it is possible to select another variable for display. After the choice, the name of the variable is displayed for about 1 second and then automatically replaced by the value of this variable. By a short press of the button (E) the name of the displayed value will be shown for about 1second. 4 CHANGE OF PARAMETERS If the button (-) is pressed longer than 1.5 seconds the display changes from display mode to the mode to change the parameters - and vice versa. The change of the parameters is done via the buttons (+) and (-) its name appears after each selection for about 1 second in the display. By a short press of the button (E) the name of the displayed value will be shown for about 1second. If the button (E) is pressed more than 1.5 seconds the parameter name will flash for about 1 second. Change of the parameter value using the buttons (+) and (-) is possible. At each time the buttons are pressed, the parameter value is increased or decreased by one unit. If the button is hold, the parameter value changes with increasing speed. After selecting the desired parameter value is stored

by pressing the button (E) in the EEPROM. By the buttons (+) and (-) the selection of the parameters is again possible. After pressing the button (+) for more than 2-seconds the displayed value begins to flash. The parameter values are stored in EEPROM. List of parameters G1: "I, Max" in amperes Corresponds to the maximum current of the solenoid coil (channel 1) at maximum setpoint voltage +10 V (or 20mA). Used e.g. to limit the hydr. parameters. Default: 860mA at Dxx1 and Dxx2 Area: 50% from.100 lmax o1: "I min" in amperes Corresponds to the offset streamed to the solenoid coil (channel 1) if the setpoint signal exceeds the threshold of 0.1 V (or 0.1 ma). E.g. used to reduce the zero coverage. Default: 200mA Range: 0.50% of lmax. r1: "Max. ramp time in seconds Determines the time in which the current to the solenoid coil (channel 1)rises from 0 to 100%, triggered by a setpoint signal from 0 to 100%. Also valid for inverse signal course. Range: 0.20 sec u1: "Ramp Up" rise time as a percentage of r1 Determines the rise time with respect to a setpoint step response from 0 to 100%. Default: 99% Range: 0.99% d1: "Ramp Down" fall-time as a percentage of r1 Determines the rise time with respect to a setpoint step response from 100 to 0%. Default: 99% Range: 0...99% d2: "Ramp Down" fall-time as a percentage of r2 Determines the rise time with respect to a setpoint response time on 100 to 0%. Default: 99% Range: 0.99% Fr: dither frequency in Hertz Determines the PWM frequency of the amplifier, thus indirectly the dither frequency of the solenoid current. This is used to minimize the hysteresis of hydraulic valves. An optimization has to be done to the hydraulic system. Default: 100Hz at Dxx1 and 200Hz for Dxx2 Area: 50.400 Hz U1 and U2: "V max" Factor for the validation of the setpoint input without loss of resolution. Example: at default mode and 10V setpoint signal, the output current is 1200mA. If Ux changed to now 500, is the amp at 10V only 600mA from. Default: 1000 Range: 0.1000 In version Dx1x only the parameters for channel 1are displayed. 5 - INSTALLATION The amplifier is foreseen for the installation on rails to DIN EN suitable 50022. The cabling is conducted over a 15-pin terminal block. For the connection of power supply and solenoids please choose cables with a diameter of 0.75 mm² for distances up to 20m and 1.00 mm ² for distances up to 40m. The cross section depends on the length of the cable. For signal lines use shielded, grounded cables at the drive electronics. G2: "I, Max" in amperes Corresponds to the maximum current to the solenoid coil (channel 2) at maximum value +10 V (or 20mA). Used e.g. to limit the hydr. parameter. Default: 860mA at Dxx1 and Dxx2 Area: 50.100% of lmax o2: "I min" in amperes Corresponds to the offset streamed to the solenoid coil (channel 2) if the setpoint signal exceeds the threshold of 0.1 V (or 0.1 ma). E.g. used to reduce the zero coverage. Default: 200mA Range: 0.50% of lmax. r2: "Max ramp time in seconds Determines the time in which the current to the solenoids coil (channel 2) rises from 0 to 100%, triggered by a setpoint signal from 0 to 100%. Also valid for inverse signal course. Range = 0.20 sec u2: "Ramp Up" rise time as a percentage of r2 Determines the rise time with respect to a setpoint on 0 to 100%. Default: 99% Range: 0.99%

NOTE 1 To observe EMC requirements it s important that the control unit electrical connection is in compliance with the wiring diagram of chapter 7. As a general rule, the valve and the electronic unit connection wires must be kept as far as possible from interference sources (e.g. power wires, electrical motors, inverters and electrical switches). In environments where there are critical electromagnetic interferences, a complete protection of the connection wires can be requested. 5.2 FUNCTION of the ramps Example: parameters for PEM-XD-Dx2x The diagram shows the curve of the current output in function of the setpoint signal PEM-XD-Dx1x PEM-XD-Dx2x PEM-XD-Dx3x

BLOCK DIAGRAMS PEM-XD-Dx1x PEM-XD-Dx2x PEM-XD-Dx3x

STANDARD MODEL Part No. PEM-XD-D021 3493285 PEM-XD-D022 3532186 PEM-XD-D031 3530881 PEM-XD-D032 3530882 Other types on request Cabling of the setpoint signal PEM-XD-Dx1x TYPECODE Name Amplifier For cap rail mounting Parameterization Digital parameterization without control option Setpoint signal 0 = voltage 0 to +/-10V 1 = current 4 - +/-20mA PEM-XD D 0 2 1 Number of coils on valve 01 = with 1 coil 02 = with 2 coils 03 = with 2 coils independent channels PEM-XD-Dx2x Pre-adjusted highest current 1 = 860 ma 2 = 1200 ma 3 = 1600 ma 4 = 1880 ma 5 = 2600 ma (only possible at 1 a. 2) DIMENSIONS PEM-XD-Dx3x Hint: If the generator only contains a differential entry (not on ground), clamp 8 (11 for PEM-XD-X3X) Has to be connected with clamp 14 1) Display- and mini USB side 2) Knob protections lock 3) Display for the signal of the cardsupply and failures 4) Terminal strip with 15 poles, cable exit to bottom 5) Printout of the electric circuit of the PSB and port overview 6) Connector for guidances according to DIN EN 50022 Annotation The technical information in this brochure are relating to the operating conditions and applications. At deviant applications and/or operating conditions please contact the technical dept. Technical information are subject to technical modifications. HYDAC Fluidtechnik GmbH Justus-von-Liebig-Str. 5 66280 Sulzbach / Saar Tel.: 06897 / 509-0 Fax: 06897 / 509-598 Email: flutec@hydac.com