COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

Similar documents
Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

FSK1VDRA 1G Al DPLX RCPT CVR

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets

Thru Wall Floor Seals For New Installation

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

Ground Clamps Cable Tray

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Cast Iron Junction Boxes

General Information...SA1-SA4

INTERMEDIATE METAL CONDUIT

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

E.M.T. Set-Screw Connectors. Technical Specifications

Section 2 Outdoor Voltage Transformers

SECTION PANELBOARDS

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

B. Manufacturers: Square-D, G.E. or Westinghosue.

SECTION TRANSFORMERS

RACO Commercial Fittings

RACO Commercial Fittings

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

SECTION METAL FABRICATIONS

Applications. Illustrated Features. Certifications and Compliances

Industrial Mercmaster LED Generation 3 Series Luminaires For Ordinary Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations

A-51 Incandescent Factory Sealed Luminaires Explosionproof Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Baymaster LED Luminaire High Bay for Hazardous Locations

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

SECTION EQUIPMENT WIRING

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

Floor Boxes. Flush Service Floor Boxes

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

Class II, Division 1 and 2, Groups E, F, G Class III CSA 4X

Regal Series Recessed Flatwalls

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

T S 15KVA 1PH 240/480 Transformer

SECTION CABLE TRAYS

Tuf-Lite III Fans 3000K Series Hub

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2

NEW OR UPGRADED ELECTRICAL SERVICE

Tuf-Lite II Fans 3000H Series Hub

tings fi t fl ex/mc/ac

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf

A. Product Data: For each electrical identification product indicated.

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

CONTINUING EDUC ATION

Thread Repair & Thread Protection

1.3. Pushbuttons and Indicating Lights.

U CON DUIT CODEGUARD. 10-IN-1 UNIVERSAL CONDUIT BODY for RIGID/IMC or EMT. Service Truck Solutions

DIVISION 26 ELECTRICAL SECTION ELECTRICAL

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub

GLOSSARY OF ELECTRICAL INDUSTRY TERMS

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

Quarter-Turn Fasteners

WIREMOLD Flushduct Infloor Duct System

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

SELF-CLINCHING STUDS AND PINS

Tuf-Lite II Fans 3000H Series Hub

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

Floor Stops - Dome. FS13 Dome Stop. FS17 Dome Stop. R14 Riser. Features:

Perma-Cote Submittal Guide Contents

Architectural Door Accessories. Markar Continuous Hinges

Tuf-Lite II Fans 3000HC Series Hub

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

content Introduction Some good reasons to use SMARTr products Reducers, Plugs Conduit Reducer Stopping Plug

Tuf-Lite III Fans 5000K Series Hub

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

BASIC TECHNICAL INFORMATION FOR REAMERS FLUTE STYLES

MAST ARMS & POLES. Ornamental Pole Top & Bases

Stud Wall Pages

Coatings ASTM B117 SST Salt Spray Test Kesternick Phosphate Zinc E-Coat Dip Spin Coatings

ANCHORS SLEEVE ANCHORS BOLT DIAMETER

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

MATERIAL & FINISH SPECIFICATIONS INSTALLATION. For Types FH, FHS, FHA, FHL, FHLS, TFH, TFHS, HFH, HFHB, HFHS and HFE studs

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Incandescent Lighting: Enclosed and Gasketed

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

Tuf-Lite III Fans 5000K Series Hub

Mercmaster LED Low Profile Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

PCS. Patient Security Service Console. Installation Instructions.

Transcription:

Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw. Applications Accommodate wiring devices such as switches and receptacles. Provide excellent service in areas where boxes are subject to rough usage. Serve as pull boxes for conductors. Permit access to conductors for maintenance. Provide openings for making splices. Allow connections for branch conduit runs. Blank bodies for special conduit entrance arrangements. Features Corrosion-resistant ideal for indoor and outdoor installations. Weatherproof, raintight and dust-tight when used with cast gasketed covers. FS and FD boxes take standard flush wiring devices. FD boxes take devices exceeding 1-5/8 in depth under fastening ears. Malleable iron for high tensile strength and ductility provides greater resistance to impact and shock. Both malleable iron and aluminum boxes have ridge top construction for positive cover/gasket/box fit. Accurately tapped, tapered threads for tight, rigid joints, ground continuity. Complete selection of covers, receptacles, plugs, gaskets and accessories. s have captive screws to speed installation, prevents loss of screws. Internal grounding screws standard. Available in single, two, three and four gang boxes. Brazed threaded hubs for threaded conduit from 1/2 thru 1-1/2 and brazed union hubs from 1/2 thru 1-1/4. Smooth, rounded integral bushing in each hub protects conductor insulation. Standard Materials Brazed hub device boxes: malleable iron Brazed hubs: malleable iron s: malleable iron or steel screws: stainless steel, 6 32 thread Standard Finishes Malleable iron boxes and covers: triple-coat (1) zinc electroplate, (2) chromate, and (3) epoxy powder coat Steel covers: zinc electroplate NEC Certifications and Compliances UL Standard: 514A UL Listed: E2527 NEMA Standard: FB-1 Reference Data When ordering drilled and tapped openings or brazed hubs for blank bodies, refer to FDH Cast Device Boxes Drilling and Tapping Information pages. Blank Bodies for Drilling and tapping. FD-3L shown. Blank Bodies for Brazed Hubs. FS-3G shown. 151

Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw. Single-Gang Box Description Depth (2.69 Deep with Lugs) Catalog Number Malleable Iron Ridge Top Use with single-gang covers Deep FD-1L Two-Gang Box, Multiple Three-Gang Box, Multiple Four-Gang Box, Multiple Use with single-gang covers Deep FD-2L Use with single-gang covers Deep FD-3L Use with single-gang covers Deep FD-4L 152

Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw. FS Box (Shallow) 2.00, FD Box (Deep) 2.69 FS and FD with Lugs Brazed Hubs Description Depth Catalog Number Malleable Iron Ridge Top Single-Gang Box Shallow FS-1GL Two-Gang Box Shallow FS-2GL FS and FD without Lugs Single Deep FD-2GL Three-Gang Box Shallow FS-3GL Single Deep FD-3GL Four-Gang Box Shallow FS-4GL Single Deep FD-4GL Two-Gang Box Shallow FS-2G Single Deep FD-2G Three-Gang Box Shallow FS-3G Single Deep FD-3G Four-Gang Box Shallow FS-4G Single Deep FD-4G Not furnished with internal ground screw. 153

Stamped Steel s Description Catalog Number Malleable Iron Steel Furnished with stainless steel screws, less gasket For square handle tumbler or toggle flush switches FSK-4TS Malleable Iron Cast s - Weatherproof Furnished with gasket and stainless steel screws Blank Cast FSK-4B-CM Gasket Replacement Neoprene for use with 4-gang cast covers above FS-GKR-4N FS-GKR-4N 154

Single-, Two-, Three-, and Four-Gang Boxes. Brazed Threaded Hubs for Rigid Conduit, 1/2 through 1-1/2 ; Brazed Union Hubs, 1/2 through 1-1/4. Determine catalog number as follows: (1) Select FDH device box catalog number; (2) Select Standard Hub Arrangement Diagram number; (3) Detemine if your desired number and trade size of conduit entries will fit in the FDH box choosen, by reviewing the Maximum Number and Size... table on page B-25. Select a larger box if you experience a fit problem: and (4) Delect symbols that represent hub sizes from Symbol Table. (Use 0 where no hub is required, and separate the various divisions of the complete catalog number by dashes.) Standard Conduit Opening Arrangement Diagrams Hub a is always TOP of box Two, Three and Four Gang (Front View) Example: The blank body device box selected is FS- 3GL and the hub arrangement is diagram #8. Hub a is to be 1/2 BRAZED THREADED; hub b, 1 BRAZED THREADED; hub c, 3/4 BRAZED THREADED; hub d, no hub is required; and hub e, 1-1/4 BRAZED UNION. The complete catalog number will be: FS-3GL 8 1320U If a Standard Hub Arrangement is not suitable for the application, or when hubs are to be more accurately spaced, submit sketch locating hubs (1) from centerlines of walls and (2) from outside back of box (or from mounting lug surface if lugs are supplied). All hubs will be located in centerlines of walls and evenly spaced unless otherwise specified. Symbol Table Hub Size (Inches) Brazed Threaded Hub Symbol Brazed Union Hub Symbol Blank 0 0 1/2 1 R 3/4 2 S 1 3 T 1-1/4 4 U 1-1/2 5 One Gang (Front View) 155

Single-, Two-, Three-, and Four-Gang Boxes. Brazed Threaded Hubs for Rigid Conduit, 1/2 through 1-1/2 ; Brazed Union Hubs, 1/2 through 1-1/4. Minimum Centerline Spacing Between Brazed Threaded Hubs Table shows minimum distances between hub centerlines in various size combinations. For example, if 1-1/4 and 1/2 openings are to be brazed on one side of box, the minimum spacing between centerlines would be 1.75. If union hubs are used, additional space must be allowed. Distance from Mounting Surface to Centerline of Brazed Threaded Hubs Minimum Centerline Spacing in Inches Hub Size (Inches) 1/2 3/4 1 1-1/4 1-1/2 1/2 31.8 (1.25) 3/4 35.1 (1.38) 38.1 (1.50) 1 39.6 (1.56) 42.9 (1.69) 46.0 (1.81) Hub Size Dimensions A 1-1/4 44.5 (1.75) 47.8 (1.88) 50.8 (2.00) 55.6 (2.19) (Inches) Millimeters (Inches) 1-1/2 49.3 (1.94) 52.3 (2.06) 55.6 (2.19) 60.5 (2.38) 65.0 (2.56) 1/2 16.0 (0.63) Hub Dia. 28.7 (1.13) 35.0 (1.38) 41.4 (1.63) 50.8 (2.00) 60.5 (2.38) 3/4 19.1 (0.75) Conduit Dia. 22.4 (0.88) 26.9 (1.06) 33.3 (1.31) 42.9 (1.69) 49.3 (1.94) 1 22.4 (0.88) UNY/UNF 1-1/4 27.7 (1.09) 38.1 (1.50) 44.5 (1.75) 50.8 (2.00) 71.4 (2.81) Union Dia. 1-1/2 31.0 (1.22) Maximum Number and Sizes of Drilled and Tapped Conduit Openings Per Top, Bottom, Side and Back Allowance made for clearance over Appleton BBU Series bushings. Hub Size Max. No. Of Openings Hub Size Max. No. Of Openings Type Box (Inches) Top or Bottom Per Side Back Type Box (Inches) Top or Bottom Per Side Back FD-1L One Single-Gang FD-2L Two Single Gang s FD-3L Three Single Gang s FD-4L Four Single Gang s FS-1GL One Single Gang FS-2G and FS-2GL One Two Gang 1/2 2 2 1 FS-3G and 1/2 4 2 6 3/4 1 2 1 FS-3GL 3/4 3 2 6 1 1 2 1 One 1 3 2 6 1-1/4 1 1 1 Three-Gang 1-1/4 None None 3 1-1/2 1 1 1 1-1/2 None None 3 1/2 4 2 4 FS-4G and 1/2 5 2 8 3/4 2 2 4 FS-4GL 3/4 4 2 8 1 2 2 4 One 1 4 2 8 1-1/4 2 1 2 Four Gang 1-1/4 None None 4 1-1/2 2 1 2 1-1/2 None None 4 1/2 6 2 6 FD-2G and 1/2 3 24 3/4 3 2 6 FD-2GL 3/4 2 2 4 1 3 2 6 One 1 2 2 4 1-1/4 3 1 3 Two Gang 1-1/4 1 1 2 1-1/2 3 1 3 1-1/2 1 1 2 1/2 8 2 8 FD-3G and 1/2 4 26 3/4 4 2 8 FD-3GL 3/4 3 2 6 1 4 2 8 One 1 3 2 6 1-1/4 4 1 4 Three Gang 1-1/4 2 1 3 1-1/2 4 1 4 1-1/2 2 1 3 1/2 2 2 1 FD-4G and 1/2 5 28 3/4 1 2 1 FD-4GL 3/4 4 2 8 1 1 2 1 One 1 4 2 8 1-1/4 None None 1 Four Gang 1-1/4 3 1 4 1-1/2 None None 1 1-1/2 3 1 4 1/2 3 2 4 3/4 2 2 4 1 2 2 4 1-1/4 None None 2 1-1/2 None None 2 Hubs will be located in center of walls and evenly spaced unless otherwise specified. Where spacings are critical, submit sketch showing exact spacing requirements. 156

Blank Bodies for Brazed Hubs. Wiring Capacity Gangs Capacity dm 3 (in 3 ) Catalog Number Volume Catalog Number Volume Single FS-1GL 0.29 (18.00) FD-1L 0.43 (26.00) Two FS-2G 0.52 (32.00) FD-2G, FD-2GL 0.74 (45.00) Two FS-2GL 0.52 (32.00) FD-2L 1.07 (65.00) Three FS-3G 0.75 (46.00) FD-3G, FD-3GL 1.02 (62.00) Three FS-3GL 0.75 (46.00) FD-3L 1.61 (98.00) Four FS-4G 0.95 (58.00) FD-4G, FD-4GL 1.28 (78.00) Four FS-4GL 0.95 (58.00) FD-4L 2.13 (130.00) Dimensions in Millimeters (Inches) Single, Multiple Gang Boxes with Multiple s 157

Blank Bodies for Brazed Hubs. Dimensions in Millimeters (Inches) Two and Three Gang Single Boxes FS and FD Four Gang Single Boxes A B FS FD FS FD 50.8 (2.00) 68.3 (2.69) 45.2 (1.78) 62.0 (2.44) 158