ICPU2-8 for imc CRONOSflex (CRFX/ICPU2-8)

Similar documents
AUDIO2-4 for imc CRONOSflex (CRFX/AUDIO2-4)

imc C-SERIES: CS-3008-N, CL-3016-N

LV3-8 for imc CRONOS-PL/-SL/compact

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

imc C-SERIES: CS-1016-N, CL-1032-N

imc C-SERIES: CS-5008-FD

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Kistler LabAmp for DynoWare

MX1615. Data sheet. Bridge/strain gauge amplifier

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses

QUAD PROGRAMMABLE FILTER/AMPLIFIERS For the and Signal Conditioning Systems

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

Variable Gain Low Frequency Voltage Amplifier

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

KMT - Kraus Messtechnik GmbH

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

Telemetrie-Messtechnik Schnorrenberg

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Variable Gain 100 MHz Wideband Voltage Amplifier

MX1615B. Data sheet. Bridge/strain gauge amplifier

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Transducer for Measurement Bridges SCM90, SIGS15

Model Channels Input type Sample rate Resolution

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

ELECTRONIC DESIGN & ENGINEERING. ICP_FM3 Versatile DC AC IEPE Signal Conditioning. 1 ICP_FM3 Introduction

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Dx: Digital Multi-Channel Telemetry System

User Manual CTP4/8/16

Analog Isolation Amplifiers

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Oscilloscope Probes and Accessories

SCXI 8-Channel Isolated Analog Input Modules

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

Model 140 Inline Amplifier

IsoAmp 11000/ Universal isolation amplifiers for ±20 mv to ±10 V or ±20 ma input signals.

MX410B. Highly dynamic universal amplifier. Data sheet. Special features. Block diagram

VariTrans P V. Safe and Sound.

PRODUCT DATA. 3-ch. Input Module LAN-XI khz Type Uses and Features

Instruction Manual. Charge Amplifiers. M68 Series. Manfred Weber

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model 600 Switching Matrix Series Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

Series GLET Accessory for dataloggers series GL in modular enclosure

DC MHZ PXI Differential Instrumentation Amplifier

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

QUAD-CHANNEL CONDITIONER BALANCED CURRENT EXCITATION ±10 V Common Mode; 255 or 510 Cutoff Frequencies

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL

5000 Series Receiver Systems

IsoAmp 3000/4000. The Advantages The dynamic range extends into the negative, allowing for strictly linear transmission

Coupling Relays and Converters

SCP for Combustion Engines

SC-4/M User manual 4-channel measuring amplifier

Q.raxx A101-8 slimline RS / EC

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

SINEAX / EURAX 2I1 Passive DC signal isolator

Instrument. Specifications OR34/35. SmartRouter. 2 to 8 Channels Multi-Analyzers. Controller Unit TECHNICAL SPECIFICATIONS

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram

Q.raxx A slimline RS / EC

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements

Differential charge amplifier

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Extreme values ors statistic measurements

28454A. QUAD-CHANNEL CONDITIONER BALANCED CURRENT EXCITATION Constant Current Excitation; 700 khz Bandwidth PRECISION 28454A APPLICATIONS

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Acceleration sensors With relay output for limit monitoring Analog / CANopen

Model 7000 Low Noise Differential Preamplifier

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

SSI Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Wide-band Models from DC to 100 MHz

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

20 General technical data XI/ON

Modular Signal Conditioning System

NDR6110 Single Channel Dynamic Driver for Piezoelectric Actuators

Low Noise Variable Gain Low Frequency Voltage Amplifier

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution

R&S OSP Open Switch and Control Platform Specifications

Transcription:

Data Sheet Version 1.7 8-channel IEPE/ICP-Measurement Module The imc CRONOSflex IEPE/ICP Measurement Module (CRFX/ICPU2-8) is ideal for the use in sound and vibration measurement engineering. Highlights Direct connection of IEPE/ICP-sensors via BNC inputs High signal bandwidth of up to 48 khz per channel Wide input-voltage range of 5 mv to 50 V, individually software selectable per channel Input coupling switchable via software: DC, AC, AC with current supply Supports imc Plug & Measure Transducer Electronic Data Sheets (IEEE 1451.4) Typical applications: Noise and vibration analysis General measurement of dynamic acceleration imc CRONOSflex IEPE/ICP Measurement Module (CRFX/ICPU2-8) imc CRONOSflex - Frameless expansion, flexible modularity An imc CRONOSflex system is composed of a base unit (CRFX-400 / CRFX-2000G) and one or more modules. These modules are designed to be directly connected to one another. The imc Click Mechanism and extruded aluminum case provide a firm mechanical and electrical connection. As a result, no mainframe or rack is needed. In addition when a module is added it is automatically recognized by the software displaying its dynamically assigned ID on the front of the module. Alternatively, connection can be made by means of standard Ethernet cables (RJ45, CAT5) thus creating a spatially distributed system. imc CRONOSflex Modules can be operated without the base unit when used as components within an EtherCAT-based automation system operating as EtherCAT slaves with full CANopen over EtherCAT (CoE) support. imc Click Mechanism imc CRONOSflex distributed system Overview of the available variants Order code article number CRFX/ICPU2-8 1190039 CRFX/ICPU2-8-ET remarks standard extended environmental range Terminal connections Measurement inputs: System bus (EtherCAT): 8x BNC 2x network plugs RJ45 1

Power supply: Module connector: LEMO.EGE.1B.302 (female) multicoded 2x 20 pin (System bus and power supply) Mechanical drawings rear view Module power supply options Direct connection (LEMO.EGE.1B.302 power socket) Adjacent module (module connector / imc Click Mechanism) EtherCAT network cable: Power over EtherCAT (PoE) For further details refer to the power options documentation. Required software version Supported by imc STUDIO version 3.0R4 and imc DEVICES version 2.7R3, or later imc Plug & Measure (TEDS) The amplifier supports TEDS and can be used together with imc SENSORS. Optional accessories AC/DC power adapter 110-230 VAC 50-60 Hz (with appropriate LEMO.1B.302 plug) 24 V DC / 60 W CRPL/AC-ADAPTER-60W-1B 1080066 24 V DC / 150 W ACC/AC-ADAPTER-150W-1B 1350139 48 V DC / 150 W ACC/AC-ADAP-48-150-1B 1350148 Power connectors ACC/POWER-PLUG-5 CRFX/MODUL-PP-90 Power connector for DC supply LEMO FGE.1B.302 plug (male, E-coded: 2 coding keys) Power connector for DC supply 90 angular LEMO.FHE.1B.302 plug (male, E-coded: 2 coding keys) 1350150 1190074 Supply module (Power Handle) CRFX/HANDLE-POWER-L CRFX/HANDLE-UPS-L CRFX/HANDLE-LI-IO-L Handle with system power supply 50 V 100 W, without UPS Handle with system power supply 50 V 100 W, UPS with lead-gel battery Handle with system power supply 50 V 100 W, UPS with Li-Ion battery 1190058 1190043 1190010 Passive-Handle CRFX/HANDLE-L standard unpowered left handle 1190008 2

CRFX/HANDLE-R standard unpowered right handle 1190007 Mounting brackets for fixed installations CRFX/BRACKET-90 mounting bracket 90 1190068 CRFX/BRACKET-180 mounting bracket 180 1190069 CRFX/BRACKET-BACK rear panel mounting element 1190070 CRFX/BRACKET-CON assembly element for 2 modules 1190071 CRFX/RACK 19" RACK for CRFX Modules 1190066 CRFX/BRACKET-RACK mounting element in the RACK 1190072 1 ICP (Integrated Circuit Piezoelectric) is a registered trade mark of PCB Piezotronic inc. 3

Data Sheet Version 1.7 Technical Specs - CRFX/ICPU2-8 Channels, measurement modes, terminal connection Inputs 8 Measurement modes Input coupling Terminal connection Sampling rate, Bandwidth, Filter, TEDS voltage measurement transducer with constant current supply DC AC, ICP BNC Sampling rate 100 khz per channel Bandwidth Filter cut-off frequency characteristic order Filter cut-off frequency (high pass, 3th order,-3db) 0.37 Hz 1.11 Hz 0 Hz to 48 khz 0 Hz to 30 khz 10 Hz to 20 khz 5 % 5 % e.g. ICP -, DELTATRON -Sensors 1 AC-coupling (or ICP) means a high pass filter at the input. To avoid drifting of the module, a high pass filter is always calculated, even if the user selects without filter. -3 db -0.1 db Butterworth, Bessel low pass or high pass filter: 8th order band pass: LP 4th and HP 4th order Anti-aliasing filter: Cauer 8.order with f cutoff = 0.4 f s for AC-coupling without filter a HP 2 nd order Bessel with f cutoff = 1 Hz (0.5 Hz with WAVE) is calculated AC, ICP, range ± AC, ICP, range > ± Resolution 24 Bit output data format selectable for each channel: a) 16 Bit Integer b) Float (24 Bit) TEDS conforming to IEEE 1451.4 Class I Mixed Mode Interface Characteristic curve linearization user defined (max. 1023 supporting points) TEDS-data and analog signal shared wire 2 4

Voltage measurement Input configuration differential single-end Voltage input ranges (IR) 50 V, 25 V,, 5 V, 2.5 V, 1 V,..., 5 mv software-configurable Surge protection 50 V permanent channel to chassis Input impedance Range > ± 333 k 0.67 M 1 M 908 k 1.82 M 20 M at DC-voltage resp. 50 Hz ICP (single-end) AC (differential) DC (differential) ICP (single-end) AC (differential) DC (differential) 0.05 % of display range (25 C) Gain uncertainty 0.02 % +20 ppm/k T a +80 ppm/k T a T a = T a -25 C ambient temperature T a Offset uncertainty drift Common mode suppression Input ranges 50 V to 5 V to 50 mv 25 mv to 5 mv Noise 0.02 % 60 µv/k T a 0.06 µv/k T a 62 db 92 db 120 db 0.4 µvrms 14 nv/ Hz 0.05 % 0.06 % 100 µv/k T a 0.3 µv/k T a >46 db >84 db >100 db of input range (25 C) > 50 mv 50 mv > T a = T a 25 C ambient temperature T a Common mode voltage (DC..60 Hz): 50 V Bandwidth 0.1 khz to 1 khz Constant current supply ICP current sources 4.2 ma/channel ±10 % Compliance voltage 25 V >24 V Source impedance 280 k >100 k Power supply of the module Parameter Value Remarks Input supply voltage to 50 V DC Isolation 60 V nominal isolation specification of the supply input Power-over EtherCAT (PoE) 42 V to 50 V DC supply via EtherCAT network cable 5

Terminal connections of the module Parameter Value Remarks EtherCAT connection Input supply plug (female) 2x RJ45 LEMO.EGE.1B.302 system bus for distributed imc CRONOSflex components multicoded 2 notches for optional individually power supply Module connector 2x 20 pin direct connection of modules (click) supply and system bus Pass through power limits Directly connected (clicked) imc CRONOSflex Modules Power-over EtherCAT (PoE) for remote imc CRONOSflex Modules 3.1 A (maximum current) Equivalent power with chosen DC power input: 148.8 W @ 48 V DC (e.g. AC/DC line adapter) 74.4 W @ 24 V DC (e.g. AC/DC line adapter) 37.2 W @ 12 V DC (typical vehicle supplied DC input) 350 ma (maximum current, corresponding to IEEE 802.3) Equivalent power with chosen DC power input: 17.5 W @ 50 V DC (e.g. Power Handle) 16.8 W @ 48 V DC (e.g. AC/DC line adapter) 14.7 W @ 42 V DC (minimum voltage for PoE) Note: minimum system power of 42 V DC required for PoE Operating conditions Operating environment (standard) Ingress Protection Rating Operating temperature range (standard) Extended environmental range (optional) dry, non corrosive environment within specified temperature range IP20-10 C to +55 C no condensation -40 C to +85 C with condensation Shock- and Vibration resistance IEC 60068-2-27, IEC 61373 Category 1, Class A and B Extended Shock- and Vibration resistance (special order) Dimensions (W x H x D) Weight MIL-STD-810F Rail Cargo Vibration Exposure U.S. Highway Truck Vibration Exposure 43.3 x 118 x 186 mm approx. 878 g 1 ICP is a registered trade mark of PCB Piezotronics Inc., Delta Tron is a registered trade mark of Bruel & Kjaer Sound and Vibration; PIEZOTRON, PIEZOBEAM is a registered trade mark of Kistler 2 Only galvanically insulated sensors. For more detailed information, please refer to chapter "MMI-TEDS" in imc CRONOS manual. 6