MI-10kV. Technical specifications Operating instructions. Supplier:

Similar documents
MD-5060 DIGITAL MEGOHMMETER

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

MIT400/2 CAT IV Insulation testers

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet

3B SCIENTIFIC PHYSICS

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT415 Insulation tester

# Digital Multimeter

79/26 Series III Multimeter

HAWK5000 Operators Manual

MIT400/2 CAT IV Insulation testers

Jewell DPM EINE BEST IN CLASS

BH series Paddle joystick controllers

DM-45 Digital Multimeter

MIT510/2, MIT520/2 and MIT1020/2

1210N 1250N MEGOHMMETER. User Manual 15 V 500V kV. MEGOHMMETER Model 1250N 600V CAT II / 1000V CAT I! 30. x 10.

MEGOHMMETER. User Manual

MSV200 - Hall effect transducer

INSULATION TESTER SERIES

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Model Microphone Preamplifier Power Supply Manual

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

BL series Miniature paddle joystick controllers

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

MIT480/2 Insulation testers

1587/1577 Insulation Multimeters

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

MAVOWATT 4 Multifunction Power Meter

BM25 Automated 5-kV Insulation Tester

1507/1503. Insulation Testers. Technical Data. Features and benefits:

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

User Manual Digital Multimeter

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Current clamps for AC current

Current clamps for AC current

High precision measurement system for current and voltage IHC-A/B-RM01/03

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

1507/1503. Insulation Testers. Users Manual

Product Specification sheet

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

374 FC/375 FC/376 FC Clamp Meter

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Power supply CP-E 24/2.5

Manual Signal calibration box (SCB)

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Model 77 Series IV. Digital Multimeter. Users Manual

Insulation Testers and Earth Ground Testers

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

UBC 200 relay - Voltage monitoring

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

3B SCIENTIFIC PHYSICS

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

MIT400 CAT IV Industrial Insulation Testers

4-range High voltage insulation resistance tester KEW 3126

Fluke 1587 FC/1577 Insulation Multimeters

Measure voltage without test leads. Product Highlights

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

MIT400 CAT IV Industrial Insulation Testers

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Power supply CP-E 24/20.0

DIGIT & POINTER MULTIMETER

Model UT511 OPERATING MANUAL

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

PART NUMBERING SYSTEM

MIT510, MIT520 and MIT1020

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Table of Contents Title Page

EC Declaration of Conformity

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

User manual ISO Analyser 5kV

AC/DC Current Oscilloscope Probe Model SL261

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

DEIF A/S. Insulation monitor. Type SIM-Q

USER'S MANUAL DMR-6700

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Transcription:

Technical specifications Operating instructions Supplier: Nieaf-Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht P.O. Box 7023, 3502 KA Utrecht The Netherlands T +31 30 288 1311 F +31 30 289 8816 E sales@nieaf-smitt.nl W www.nieaf-smitt.nl Helpdesk T +31 30 285 0285 E helpdesk@nieaf-smitt.nl Specifications of the equipment Specifications of the user manual - May 2004 Number:

There are hazardous voltages involved in assays carried out using this megohmmeter. Although output current of the megohmmeter is limited, external capacities are charged to very high potentials and there is no protection against them. So, a suitably trained and competent person, strictly applying corresponding security standards should only use this equipment.

Contents Description...4 Immunity Against Electric and Magnetic Fiels...4 Operator's Safety...4 Technical Specifications...5 Measuring Intervals, Test Voltages...5 Test Voltages Accuracy...5 Megohmmeter Accuracyl...5 Short-circuit Current...5 Analogue Indicator...5 Environmental Protection...5 Safety Class...5 E.M.C....5 Electrostatic Immunity...5 Power Supply...5 Battery Charger...5 Operating Temperature Range...5 Storage Temperature Range...5 Humidity Range...5 Battery Test...5 Dimensions and Weight...5 Supplied Accessories...5 Control Panel...6 Operating Instructions...7 Battery Charger...10 Application Note # 32...11 - - 3 - Utrecht

Description The Nieaf Instruments electronic megohmmeter is a versatile, portable, user friendly, rugged instrument. It uses an efficient, well experienced technology providing reliable, safe and accurate insulation resistance measurements up to 2.000.000M Ω, with four test voltages: 1.000, 2.000, 5.000 and 10.000V. Due to its compact size and reduced weight, mechanical strength, self-contained battery supply, this apparatus is particularly suitable for field tests under severe environments. It is easy to be carried, very simple to be operated and stands severe handling conditions including frequent shocks, extreme temperatures, vibrations during transportation through hard roads, long direct exposure to solar radiation, dust, sand and other air-borne impurities etc. Accuracy is not affected by all these conditions and it is still comparable with that of the best laboratory instruments. Immunity against electric and magnetic fields The Nieaf Instruments megohmmeters feature an effective filtering system that improves immunity against electromagnetic disturbances and prevents variations induced by industrial frequency fields. Operator s Safety Due to the high voltages involved, operator s safety is a must. Nieaf Instruments megohmeters were designed considering this outstanding aspect: ENCLOSURE: Moulded in high dielectric strength plastic. HIGH-VOLTAGE INDICATOR LIGHT: An indicator light (LED) is warning the presence of high voltage at the output terminal during a measurement and remains lit until the discharge process is completed. - - 4 - Utrecht

Technical Specifications MEASURING RANGES (MΩ) Test Voltage (Volts) A B C Cx10 Scale Multiplier Output Resistance 1.000 0 20 10 300 200 20.000 2.000 200.000 X 1 1MΩ 2.000 0 40 20 600 400 40.000 4.000 400.000 X 2 2MΩ 5.000 0 100 50 1.200 1.000 100.000 10.000 1.000.000 X 5 5MΩ 10.000 0 200 100 3.000 2.000 200.000 20.000 2.000.000 X 10 10MΩ TEST VOLTAGES ACCURACY OPERATING TEMPERATURE RANGE +2% of nominal test voltage on R> 10GΩ -5 o C to 50 o C MEGOHMMETER ACCURACY Class 2 (+ 2% of full scale deflection) SHORT-CIRCUITCURRENT 1,0mA ANALOGUE INDICATOR Up to 100 mm. Scale length, tautband, with Mirror (thus avoiding parallax errors) ENVIRONMENTAL PROTECTION IP54 with closed lid. SAFETY CLASS Meets the requirements of IEC 61010-1/1990, IEC 61010-1/1992-2 E.M.C. In accordance with IEC61326-1 ELECTROSTATIC IMMUNITY In accordance with IEC1000-4-2 POWER SUPPLY Internal rechargeable 12V 7Ah sealed lead acid battery STORAGE TEMPERATURE RANGE -25 o C to 65 o C HUMIDITY RANGE 95% RH (non condensing) BATTERY TEST Allows checking battery status under real consumption conditions without interrupting the generation of test voltages GUARD TERMINAL Allows the measurement of very high resistance values, avoiding the effect of stray resistance. DIMENSIONS 378 x 308 x 175 mm. (housing only) WEIGHT 9,5 kg (including accessories) SUPPLIED ACCESSOIRES Every megohmmeter is supplied with a full set of test leads, rechargeable battery, charger, carrying bad and operating manual. BATTERY CHARGER For 200/240V~, 50/60Hz, 40VA, mains supply - - 5 - Utrecht

Control Panel 1. Power input (220/240V~) 10. Mechanical adjust (Infinite 2. Fuse 11. ON indicator 3. 10kV test voltage 12. High voltage indicator 4. 5kV test voltage 13. Key board range (A,B,C&CX10) 5. 2kV test voltage 14. Battery charger indicator 6. 1kV test voltage 15. Battery check key 7. Current return terminal (-R) 16. ON/OFF switch 8. GUARD terminal (G) 17. START key 9. Analogue indicator 18. STOP key - - 6 - Utrecht

Operating Instruction 1) Be sure that there are no voltage differences between the points at which the megohmmeter will be connected, or between them and ground. Caution This megohmmeter is inhibited to generate test voltage while it is connected to mains. Therefore, the power cable has to be unplugged from mains prior to press the start button. 2) Determine the value of test voltage to be used in the insulation resistance measurement. 3) Connect the connector red pin of the red cable to the 10kV(3), 5.kV (4), 2kV (5), of 1kV (6), V terminal in accordance with the desired test voltage. 4) Connect the black cable to the R (7) megohmmeter terminal (See fig. 2) - - 7 - Utrecht

5) The green GUARD (8) terminal is not always used. Application Note #32 explains the use of GUARD (8) terminal is order to minimizing the effect of stray resistances. When measurements is carried out between parts which is none of them is grounded, (like between high-side and low-side windings of a transformer), GUARD (8) terminal must be connected to ground in order to fix the apparatus potential. At any time a measurement is performed, either the R (7) or GUARD (8) terminals must be connected to ground but never both simultaneously. If non of these terminals are connected to ground, the megohmmeter can reach a high potential that may result in a stable reading. If both terminals are simultaneously connected to ground, there is a shortcircuit between them and consequently the megohmmeter will measure with error. 6) Connect the free ends of cables (dolphin clips) to the element to be measured. 7) Turn of the apparatus by pressing the ON/OFF (16) key. The ON LED (11) begins to bright. 8) Press the START KEY (17). Then the high-voltage generator starts operating and the corresponding indication light turns on at the front panel. The meter pointer will indicate the value of the unknown resistance. If the element to be measured is strongly capacitive it will initially indicate a low resistance value, which will be gradually increased while the charging of that capacitance takes place. The instrument will always begin in the scale A. See fig. 3. 9) When the measured resistance exceeds the maximum value in range A, press range B key, and if still the value is not achieved, press keys of ranges C or Cx10, as required. - - 8 - Utrecht

10) Always remember to multiply the reading by the factor stated in the following table, depending on selected test voltage: 11) When key C x 10 is used, reading shall be carried out in range C and shall be multiplied by 10, in addition to the factor corresponding to the test voltage. 12) When you press STOP KEY (18), the megohmmeter will start discharging the potentials accumulated in the apparatus internal capacitances and in those of the element under test as well. When this discharging process is over (up to 60 seconds after turn off) the HIGH-VOLTAGE LED (12) will turn off automatically. The test leads may be disconnected. To finish measurement press again and release ON/OFF switch (16). 13) In certain instances, when the apparatus is disconnected the pointer exceeds the infinite position to the right side. This is a normal behaviour. 14) Checking battery status. Battery measurement can be performed without interrupting high-voltage generation, which will proved a better evaluation of the battery status, by pressing the Battery Icon key (15) during the measurement. So, the battery test is performed under actual consumption conditions and, for long lasting measurements, (i.e. Polarisation Index), the evolution of battery status can be checked without affecting the measurement. The meter pointer should stop over the blue zone. If the pointer stop over the red zone, this means that the battery is discharged and shall be charged. 15) Infinite setting (10). The mechanical zero of galvanometer must be periodically checked. In order to perform this checking, be sure that the megohmmeter is off. The pointer should stay on the right end of the scale just over the infinite mark on scale C. In other case, the plastic screw at the bottom of the galvanometer acrylic cover shall be adjusted. - - 9 - Utrecht

Battery Charger This equipment has an intelligent built-in circuit that controls the battery charge and does not allow the equipment to operate during the charging process. In order to charge the battery, follow the following procedure: Verify that the ON/OFF switch (16) is switched off. Connect the equipment to mains with power cord at the Power Input (01) of the equipment. After a while, the luminous indicator LED (14) will blink alternatively in green and red during one second, while the charger verifies the initial condition of the battery to select the optimised parameters of the charge. Later, the LED indicator (14) will keep on being lit in red, up to completing the charge. When the indicator changes to green and will keep being like this up to the equipment is unplugged from mains. If during the charge the system detects that for any reason the battery is not receiving the normal charging current the LED indicator (14) will blink in red. If at the end of the maximum charging time, the battery has not reached the complete charge, LED (14) will keep on blinking in green. The following chart summarises the meaning of LED luminous indications (14): Green and red flashing alternatively Permanent red Flashing red Permanent green Flashing green Test of the initial condition of the battery when plugging the mains, during one second. Battery under charge. Charging current is less than normal. The charging process has been successfully finished. Battery OK. The charging process has finished, nevertheless the battery has not received the complete charge. Note: The battery looses part of its charge while being stored. Thus, before using the megohmmeter for the first time, or after a time being out of use, the battery should be recharged. - - 10 - Utrecht

Application not #32 Use of the GUARD terminal in megohmmeters When insulation resistance measurements are performed with megohmmeters, specially with high-sensitivity instruments measuring high resistance values, the use of the GUARD terminal avoids the harmful influence of stray resistances. In order to better explain the function of this terminal, let us start reviewing the megohmmeter basic circuit diagram of Fig. 1. Where: V: DC high-voltage generator Ri: Generator internal resistance A: Indicator meter (microammeter) The unknown resistance (Rx) is connected between Vt and R terminals. Its value determines the current through the circuit, which in turn is indicated by the microammeter. The value of Rx can be determined as follows: V Rx = I - Ri - - 11 - Utrecht

In many cases the resistance to be measured is in parallel with other stray resistances which influence on Rx should be minimum and if possible, zero. A typical example of this situation is when the insulation resistance between primary and secondary windings of a transformer mounted inside a metal housing is be measured. Rx: Insulation resistance between primary and secondary winding. R1: Insulation resistance between primary winding and housing. R2: Insulation resistance between secondary winding and housing. If megohmmeter (terminals Vt and R) is connected to transformer terminals A and B, and considering that the resistance of the turns on each side of the transformer may be disregarded as compared with the insulation resistance between primary and secondary windings measured by Megohmmeter, Rx appears to be in parallel with (R1+R2). The situation is changed if we connect the transformer housing to GUARD terminal. - - 12 - Utrecht

Then the resulting circuit will be: In the circuit of Fig. 3, it may be noted that R1 is in parallel with a low-value resistance (the one from the microammeter) therefore its influence is reduced during reading. Through resistance R2 circulates a current which is not passing through the meter and consequently does not affect the reading. In fact, current through R2 originates a certain error, since is creates an additional voltage drop in R1, which was not regarded during megohmmeter calibration. As regards the practical use of megohmmeter, it shall be considered that if R1 and R2 are higher than 100MΩ, any value of Rx will be measured with an error lower than 10%. For example: Let us consider Rx = 3.000MΩ and R1 = R2 = 100MΩ, the reading without using the GUARD terminal would be 187,5MΩ, which is quite wrong. On the other hand, if the GUARD terminal is properly used, we would have 3.000MΩ, with an error lower than 10%. - - 13 - Utrecht