Development of new dosimeter for measuring dose distribution in CT

Similar documents
Evaluation of no-grid radiography using the digital scattered x-ray removal processing

Improvement of CT image quality with iterative reconstruction idose4

Investigation of Effective DQE (edqe) parameters for a flat panel detector

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Influence of different iteration levels in fourth generation iterative reconstruction technique on image noise in CT examinations of the neck

Dose reduction using Cu-filter for full-spine radiografic examination of patients with adolescent idiopathic scoliosis

Computer applications, PACS, Instrumentation, Equipment, Technology assessment /ecr2012/C-0655

The impact of increasing SID on patient dose in pa abdomen imaging

A comparison between medical-grade liquid crystal display (LCD) and ipad color imaging

Visualization of sources of scattered radiation from x-ray equipment used for interventional radiology

Fundamental and Clinical Studies for Effectiveness of Zero-filling Interpolation on k-space for Improvement of Sharpness in Magnetic Resonance Imaging

A study of exposure index value fluctuations in computed radiography and direct digital radiography using multiple manufacturers

Aim. Images for this section: Page 2 of 13

Comparison of high-resolution C-arm cone-beam CT imaging and conventional 3D rotational angiography for the better microvascular visualization

Multi-slice computed tomography analysis of bullet trajectory in forensic investigation.

Suppression of metal artifacts using image-based monoenergetic DECT imaging

Analysis of spatial dependence of acoustic noise transfer function in magnetic resonance imaging

Determining acceptance levels for automatic daily image quality control in magnetic resonance imaging

Correction of the local intensity nonuniformity artifact in high field MRI

Clear delineation of optic radiation and very small vessels using phase difference enhanced imaging (PADRE)

Lumbar disc height assessment: a comparative study between EOS and digital radiography

Practical guidelines for color calibration and quality assurance of medical displays

Effective energy measurement using radiochromic film: application of a mobile scanner

Difference in signal-to-noise-ratio (SNR) from vertical to horizontal scanner position using a 0,25 Tesla Weightbearing

NOT FOR DISTRIBUTION JINST_083P_0914 v1

QC Testing for Computed Tomography (CT) Scanner

Novel cassette-sized, flat-panel digital radiography (DR) system: Initial clinical and workflow results versus computed radiography (CR)

Worldwide practice of breast MRI: insights from the MIPA study applications - the MIPA study group

A Guide to Radiochromic Film Dosimetry with EBT2 and EBT3

Wide beam CT dosimetry. Elly Castellano

The most Comprehensive, Reliable, Economical and Easy to use GAFCHROMIC film based RT QA system Updated Feb 08 BUSINESS UNIT OF ISP

The role of CT in restoration of a very rare Christ wooden statue: a fundamental contribution.

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Nuclear Associates , , CT Head and Body Dose Phantom

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

Use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation beam

Analysis of Post-exposure Density Growth in Radiochromic Film with Respect to the Radiation Dose

- Water resistant. - Large size.

PROJECT TIPIRX (integration of teleradiology using Lowcost digitalization of X-ray films): a Brazilian solution

PROJECT TIPIRX (integration of teleradiology using Lowcost digitalization of X-ray films): a Brazilian solution

Exposure in Dental Radiology: A Comparison Between Intra-oral, Panoramic and Tomographic Examinations

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

State of the Art Film Dosimetry

GAFCHROMIC. Therapy Dosimetry Media Models to

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Diagnostic X-Ray Shielding

Measurement of table feed speed in modern CT

Optimal speed for dual-energy subtraction neck imaging with flat-panel detector radiography

QA Considerations. QA for LGK Perfexion : : Follow NRC licensing guidelines (10( CFR ) Leksell Gamma Knife Perfexion

Derivation of total filtration thickness for diagnostic x-ray source assembly

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

Homogeneity of GAFCHROMIC EBT2 film among different lot numbers

I. Introduction.

diagnostic examination

Dose Reduction in Helical CT: Dynamically Adjustable z-axis X-Ray Beam Collimation

Image Quality and Dose. Image Quality and Dose. Image Quality and Dose Issues in MSCT. Scanner parameters affecting IQ and Dose

Test Equipment for Radiology and CT Quality Control Contents

The feasibility of breath-hold high-resolution 3D-MRCP obtained with 32 channel torso cardiac coil and T2-prepBTFE

2012 :15th SESSION of ESMP

A comparison of two methods for the determination of freein-air geometric efficiency in MDCT

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Principles of CT scan

computed tomography, computed tomography dose index, dosimetry

COMPUTED TOMOGRAPHY 1

RaySafe X2. Effortless measurements of X-ray

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

CT radiation profile width measurement using CR imaging plate raw data

Y11-DR Digital Radiography (DR) Image Quality

PD233: Design of Biomedical Devices and Systems

Introduction of a Single Chip TLD System for Patient Dosimetry

Using Radiochromic Film Tips and Techniques

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

Ludlum Medical Physics

Film Replacement in Radiographic Weld Inspection The New ISO Standard

IV. 4. An Optical Common-mode Rejection for Improving the Sensitivity Limit of a Radiochromic Imaging Film

Comparing three UV wavelengths for pre-exposing Gafchromic EBT2 and EBT3 films

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

GafChromic EBT2 and EBT3 Films for Ball Cube II Phantom

inspexio SMX-225CT FPD HR

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

Tomophan TSP004 Manual

GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data

Acceptance Testing of a Digital Breast Tomosynthesis Unit

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

abc MHRA Philips Mx8000 IDT CT scanner technical evaluation September 2004 Best choice best practice nww.medical-devices.nhs.

A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering

Post-irradiation colouration of Gafchromic EBT radiochromic film

High Energy Digital Radiography & 3D-CT for Industrial Systems

Fig.2: Scanner VistaScan for image plates

Research Support. Dual-Source CT: What is it and How Do I Test it? Cynthia H. McCollough, Ph.D.

160-slice CT SCANNER / New Standard for the Future

CT Scanner Dose Survey

Transcription:

Development of new dosimeter for measuring dose distribution in CT Poster No.: C-2925 Congress: ECR 2010 Type: Scientific Exhibit Topic: Physics in Radiology - Without Subtopic Authors: Y. Muramatsu, K. Nomura, K. Hanai, N. Moriyama, T. Iyoki, Y. 1 4 1 2 2 2 3 1 3 4 Morishita ; Tokyo/JP, Chiba/JP, Kanagawa/JP, Tochigi/JP Keywords: CT, Dosimetry, Quality Control Keywords: Physics DOI: 10.1594/ecr2010/C-2925 Any information contained in this pdf file is automatically generated from digital material submitted to EPOS by third parties in the form of scientific presentations. References to any names, marks, products, or services of third parties or hypertext links to thirdparty sites or information are provided solely as a convenience to you and do not in any way constitute or imply ECR's endorsement, sponsorship or recommendation of the third party, information, product or service. ECR is not responsible for the content of these pages and does not make any representations regarding the content or accuracy of material in this file. As per copyright regulations, any unauthorised use of the material or parts thereof as well as commercial reproduction or multiple distribution by any traditional or electronically based reproduction/publication method ist strictly prohibited. You agree to defend, indemnify, and hold ECR harmless from and against any and all claims, damages, costs, and expenses, including attorneys' fees, arising from or related to your use of these pages. Please note: Links to movies, ppt slideshows and any other multimedia files are not available in the pdf version of presentations. www.myesr.org Page 1 of 38

Purpose 1. Introduction As the number of detector rows in CT scanners is increased, the X-ray beam width becomes larger. In general, the beam width of a 64-row multidetector CT (MDCT) scanner is approximately 40 mm and that of an area detector CT (ADCT) scanner is 160 mm. A 64-DAS MDCT scanner, with more detector rows and a larger beam width, permits the entire body to be scanned in approximately 10 s, and an ADCT scanner allows the entire heart to be covered in a single rotation. The CT dose index (CTDI), dose-length product (DLP), and dose efficiency (DE) are used as indices for measuring the exposure dose of CT systems (reference 1, 2). The most basic value, CTDI, is measured using a cylindrical methacrylate resin phantom and a pencil chamber in combination, with the measured value corrected by the beam width in the calculation. The DLP is calculated by multiplying the weighted CTDI (CTDIW) by the total scan time. In addition, the half-value width (FWHM) of the beam profile is measured by film dosimetry in which ready-pack films or radiochromic films are employed in order to calculate the DE. However, it has been reported that when the exposure dose of a CT system with a larger beam width is evaluated, the dose is underestimated when a conventional 100-mm pencil chamber is used, and as a result, accurate measurement results cannot be obtained (reference 3). Taking into consideration the evaluation of exposure dose by Monte Carlo simulation such as the Electron Gamma Shower (EGS), it is important to assess the two-dimensional dose distributions in air and the energy spectrum in order to evaluate the exposure dose accurately. However, it is difficult to measure two-dimensional dose distributions easily by film dosimetry. The present study was therefore conducted in order to develop a new dosimeter for measuring the two-dimensional dose distribution in CT. Page 2 of 38

Page 3 of 38

Methods and Materials 2. Methods 2.1 Structure of the dose distribution measurement system and dose calibration 2.1.1 Structure of the dose distribution measurement system A newly developed dose distribution measurement system (PA-32, Toreck, Japan) is shown in Fig. 1 on page 7. The sensor section is mounted on rails with a length of 400 mm. The sensor section can be set at any desired position on the rails (stationary mode) and can also be moved along the rails at constant speed (move mode: 6.7, 10, or 16 mm/s, Fig. 2 on page 7, video clip) using the dedicated software, which runs on a standard Windows personal computer. The dose measurement time can be selected from among 2.5, 5, 10, 30, and 60 s. A pattern diagram and the external appearance of the radiation receiving (sensor) section of the dosimeter are shown in Fig.3 on page 8. The radiation sensor section consists of an array of 32 small semiconductor detector elements arranged in a single row. Each element measures 1.175 mm 2 mm, and the elements are spaced at 1.575-mm intervals. The entire sensor measures 2 mm 48.825 mm. (It should be noted that the value of 50.4 mm given in the abstract we submitted previously was incorrect due to a calculation error.) 2.1.2 Dose calibration In general, in order to perform dose calibration for a dosimeter intended for diagnostic applications, the correction value is calculated in a uniform X-ray field generated by a general-purpose X-ray system. In CT systems, however, thick, wedge-shaped bow tie filters made of materials such as Al are employed. In the present study, an ADCT scanner (Aquilion ONE, Toshiba, Japan) was used to generate a uniform X-ray field with the energy spectrum of a CT system. In addition, a semiconductor dosimeter (Xi, Unfors Instruments AB, Sweden) was used as a field dosimeter with calibration performed using a reference dosimeter. The dose distribution in the axial direction in the Aquilion scanner was found to be influenced by heel effects (Fig. 4 on page 9, reference 3). The center of the sensor of the Xi or PA-32 was shifted 35 mm toward the anode from the central axis of rotation, where the dose distribution is maintained at a constant level. Figure 5 on page 10 shows diagrams of the geometric layouts at the time of measurement, and Fig. 6 on page 11 shows the external appearance of the Xi (left panel) and of the PA-32 (right panel) at the time of measurement. The maintenance mode of the Aquilion ONE scanner was used to perform exposure with the X-ray tube fixed at 0. The exposure conditions were fixed, with a beam width of 160 Page 4 of 38

mm, the large bow tie filter, and an exposure time of 1.0 s. The tube voltage was varied (80, 100, 120, and 135 kv), and the tube current was adjusted so that the dose read by the Xi was approximately 30 mgy as required. 2.2 Comparison of X-ray beam profiles obtained using the film method and the dose distribution measurement system Radiochromic films (GAFCHROMIC XR-SP2, lot # A05140904, ISP, USA) and the PA-32 were used to measure the beam profiles in the axial direction in a 16-DAS MDCT scanner (Aquilion 16, Toshiba, Japan) and the measurement results were compared. 2.2.1 Exposure method and conditions The maintenance mode of the Aquilion 16 scanner was used to generate X-rays with the X-ray tube fixed at 0. X-rays were generated with various tube voltages (80, 100, 120, and 135 kv), various tube currents (80, 100, 130, and 190 ma), the focus size set to L, various beam widths (8, 16, and 32 mm), an exposure time of 1.0 s, and the large bow tie filter. For the PA-32, measurement was also performed with the focus size set to S. 2.2.2 Measurement by the film method A sheet of GAFCHROMIC film measuring 10 inches 12 inches was cut into strips measuring 30 mm in width 10 inches (approx. 254 mm) in length. A strip of film was placed at the center of rotation with its long side oriented in the axial direction, and the strip was then scanned (Fig. 7 on page 12). After exposure, the strip of film was placed in a light-tight box and stored at room temperature (24 C) for 48 hours. The strips of GAFCHROMIC film were scanned using a flatbed scanner (ES-10000G, Epson, Japan). The scanner settings were a 16-bit gray scale, a resolution of 300 dpi, and a scan range of 46 mm 76 mm. The scanned images were saved in TIFF format. The images were analyzed using ImageJ (NIH, MD, USA. reference 4). An ROI measuring 100 pixels 900 pixels was placed on the image (Fig. 8 on page 13) to measure the beam profiles in the axial direction. The measured pixel values (net pixel values: PV net) were converted using a dose conversion table (Appendix) relative to the PV net obtained using the Aquilion ONE scanner beforehand. 2.2.3 Measurement using the dose distribution measurement system Measurement was performed in stationary mode. The sensor section of the PA-32 was placed with its long side oriented in the axial direction, and the PA-32 was set at the center of rotation (Fig. 9 on page 14). In order to improve the measurement accuracy Page 5 of 38

of the beam profiles, X-rays were generated at 9 points (-40.5, -40.0, -39.5, -0.5, 0, 0.5, 39.5, 40.0, and 40.5) in the axial direction for each beam profile measurement. The nine profiles obtained were then superimposed. 2.3 Measurement of the two-dimensional dose distributions using the dose distribution measurement system Measurement was performed in move mode. The sensor section of the PA-32 was placed with its long side oriented in the axial direction, and the PA-32 was set with the center of the sensor shifted 172 mm toward the 0 tube position from the center of rotation (Fig. 10 on page 15). The maintenance mode of the 64-DAS MDCT scanner (Aquilion 64, Toshiba, Japan) was used to generate X-rays with the X-ray tube fixed at 0. X-rays were generated with various tube voltages (80, 100, 120, and 135 kv), various tube currents (50, 75, and 100 ma), various exposure times (25, 40, and 60 s), two types of bow tie filters (small and large), and a beam width of 32 mm (slice thickness of 0.5 mm 64 DAS). During exposure, the sensor was moved at a constant speed (6.7, 10, or 16 mm/s) along rails in the x-scan plane direction in order to acquire data over a range of 400 mm (Fig. 11 on page 16, video clip). The output of the sensor (for which energy correction was performed using dedicated software and magnification ratio correction was performed using a homothetic ratio) was converted to the two-dimensional dose distribution at the center of rotation. Page 6 of 38

Images for this section: Fig. 0: Newly developed dose distribution measurement system (PA-32, Toreck, Japan) Page 7 of 38

Fig. 2: A acquisition method has stationary mode and move mode. A video clip is a situation of move mode collection. Page 8 of 38

Fig. 0: X-ray receiving section of the dosimeter Left: External appearance Right: Pattern diagram (The value of 50.4 mm given in the abstract we submitted previously was incorrect due to a calculation error.) Page 9 of 38

Fig. 0: Heel effects in the Aquilion ONE scanner (reference 3) Example of the measured dose profile along the z-axis obtained with a tube voltage of 120 kv and the medium bow tie filter "Geleijns J et al. (2009) Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner.phys Med Biol 54(10): 3141-59 Page 10 of 38

Fig. 0: Calibration of the dosimeters using ADCT (geometric layouts) Page 11 of 38

Fig. 0: Calibration of the dosimeters Left: Xi (Unfors, Sweden) Right: PA-32 (Toreck, Japan) Page 12 of 38

Fig. 0: Measurement of X-ray beam profiles using the film method (GAFCHROMIC film: XR-SP2, ISP, USA) Page 13 of 38

Fig. 0: Measurement of X-ray beam profiles using the film method Image analysis using Image-J ROI size: 100 pixels x 900 pixels Page 14 of 38

Fig. 0: Measurement of X-ray beam profiles using the dose distribution measurement system (PA-32, Toreck, JAPAN) Page 15 of 38

Fig. 0: Measurement of two-dimensional dose distributions using the dose distribution measurement system (PA-32, Toreck, Japan) The sensor section was shifted 172 mm toward the 0 tube position from the center of rotation. Page 16 of 38

Fig. 1: Measurement of X-ray beam profiles using the move mode of the PA-32 system Page 17 of 38

Results 3. Results 3.1 Dose calibration using the dose distribution measurement system (PA-32) Figure 1 on page 23shows the dose calibration results obtained using the PA-32. The horizontal axis of the graph represents the half-value layer of the tube voltages measured by the Xi, the left vertical axis of the graph represents the absolute values of the output values (calibration values) of the PA-32 relative to the dose obtained using the Xi, and the right vertical axis of the graph represents the relative values assuming that the output value of the PA-32 relative to the dose obtained using the Xi at a tube voltage of 120 kv is 1.0. The half-value layer at tube voltages of 80, 100, 120, and 135 kv measured by the Xi were 4.36, 5.37, 6.20, and 6.70 mmal, respectively. The calibration values relative to each halfvalue layers were 20.42, 21.95, 23.36, and 24.38 µgy/digital, respectively. The energy dependency was ±8.5% over the range of energies measured (39.5 kev to 49.5 kev). 3.2 Comparison of X-ray beam profiles between the film method and the dose distribution measurement system (PA-32) Figure 2 on page 23 shows the beam profiles obtained with a beam width of 32 mm (2-mm slice 16 DAS) measured using GAFCHROMIC film and the PA-32. Figures 3 on page 24 and 4 on page 25also show the beam profiles obtained with beam widths of 16 mm (1-mm slice 16 DAS) and 8 mm (0.5-mm slice 16 DAS) measured using GAFCHROMIC film and the PA-32. The tube voltage was fixed at 120 kv (5.56 mmal) and the focus size used was the large focus. Figure 5 on page 26 shows the beam profiles obtained with a beam width of 32 mm at each tube voltage measured using the PA-32. The horizontal axis of the graph represents the distance in the axial direction assuming that the center position of the slice plane is 0, and the vertical axis of the graph represents the relative dose normalized by the maximum dose under different conditions. Tables 1 and 2 show a comparison of the half-value widths calculated from the dose profiles. For all beam widths, the overall shapes of the beam profiles showed good agreement. In addition, there was almost no variation in the shapes of the beam profiles at all tube voltages. However, as the beam width became smaller, the beam profile obtained using the film method also became narrower due to the effects of the size of the semiconductor elements, showing a difference of 2% to 6% in the half-value width. 12okV (fixed) PA-32 GAFCHROMIC Page 18 of 38

film Focus size Small/Large Large Error (%) Beam width 40.5 / 42.5 41.4 2.3 16 mm (1 x 16) 21.9 / 23.2 22.5 3.0 8 mm (0.5 x 16) 12.8 / 14.1 13.3 5.7 (slice x DAS) 32 mm (2 x 16) Table 1 Comparison of the half-value widths based in the beam profiles obtained using the radiochromic film and the two-dimensional dose distribution measurement system 32 mm (2 x 16) PA-32 (fixed) GAFCHROMIC film Focus size Large Large Error (%) Tube voltage (kv) 42.3 41.4 2.1 100 42.3 41.4 2.1 120 42.4 41.4 2.3 135 42.5 41.3 2.8 80 Table 2 Comparison of the half-value widths based on the beam profiles obtained using the radiochromic film method and the two-dimensional dose distribution measurement system 3.3 Measurement of the two-dimensional dose distributions using the dose distribution measurement system Figure 6 on page 27shows the two-dimensional dose distributions at tube currents of 50, 75, and 100 ma. The exposure conditions were a tube voltage of 120 kv (5.56 mmal), a beam width of 32 mm, and the large bow tie filter. The x-axis represents the position in the scan plane direction with the center of rotation assumed to be 0, the z-axis represents the distance in the axial direction with the center position of the slice plane assumed to be 0, and the y-axis represents the dose in air corrected based on the results shown in Fig. 1. The overall shapes of the two-dimensional dose distributions showed good agreement. The doses at point 0 were 19.8 mgy, 29.9 mgy, and 39.8 mgy at tube Page 19 of 38

currents of 50 ma, 75 ma, and 100 ma, respectively, showing good agreement of the tube current ratios (50:75:100 = 1:1.51:2.01). Figure 7 on page 28shows the two-dimensional dose distributions obtained at sensor movement speeds of 6.7, 10, and 16 mm/s using the PA-32. The exposure conditions were a tube voltage of 120 kv, a tube current of 75 ma, a beam width of 32 mm, and the large bow tie filter. The two-dimensional dose distributions showed good agreement, with no dependence on the sensor movement speed. Figure 8 on page 29shows the two-dimensional dose distributions acquired with the large (5.56 mmal) and small (6.83 mmal) bow tie filters. The exposure conditions were a tube voltage of 120 kv, a tube current of 75 ma, and a beam width of 32 mm. The dose distribution acquired with the large filter showed higher dose levels around the center and a smoother shape horizontally. Figure 9 on page 30shows the two-dimensional dose distributions at tube voltages of 80, 100, and 135 kv. The exposure conditions were a tube current of 75 ma, a beam width of 32 mm, and the large bow tie filter. The higher the tube voltage, the higher the dose. The dose ratios between the four tube voltage settings of 80, 100, 120, and 135 kv were 0.47:0.72:1.0:1.21. 4. Discussion Due to the larger beam width resulting from the introduction of MDCT with a larger number of detector rows, it is important to assess the two-dimensional dose distribution more accurately, but dose evaluation focusing on the conventional CTDI measurement method is limited. In the present study, we have developed a measurement system that permits extremely accurate two-dimensional dose distributions to be obtained easily. Table 3 shows a comparison of the characteristics of the radiochromic film method and the two-dimensional dose distribution measurement system PA-32. Using the PA-32, measurement can be performed repeatedly by setting the level and the sensor section at specific locations based on CT images. The two-dimensional dose distribution and the beam width were analyzed in real time when X-ray generation was completed. The energy dependency was ±8.5%, which was higher than that for radiochromic film (±5.0% for the XR-QA type, no data for XRSP2 type). It was also affected by the absolute size (1.175 mm) of the semiconductor elements. However, when the beam width was 10 mm or more, the difference in the half-value width between the radiochromic film method and the PA-32 was 5% or less, indicating equivalent measurement performance capabilities. Page 20 of 38

For radiochromic film, on the other hand, analysis can basically be started after 24 hours or more has elapsed. It is also necessary to take into consideration the particular characteristics of the film (which plays the role of the sensor) and the measurement environment, such as light shielding and temperature control. In addition, radiochromic films cannot be recycled and are therefore not environment-friendly. It should be noted that radiochromic films can be used to perform measurement in phantoms and in water, permitting dose evaluation including scattered radiation. However, as the beam width has increased, the phantoms used for CTDI measurement have became larger and larger. For example, the abdominal phantom measures 320 mm in diameter 350 mm in length and weighs 34.5 kg (reference 5). Since two-dimensional dose distributions in air can be obtained easily using the PA-32, it is considered that Monte Carlo simulation such as EGS is practical for evaluation of the dose including scattered radiation. It should be noted that the minimum acquisition time for two-dimensional dose distributions using the PA-32 is 25 s. In modes other than maintenance mode, the measurement environment cannot be ensured easily, which is a future challenge. Factor PA-32 GAFCHROMIC film Processing work Simple Complicated Processing time Real time 24 hours Recycling Possible ±5.0%* Individual differences Minimal Yes Evaluation of Not possible** Possible scattered radiation *: Based on the catalog data for XR-QA film (No data for XR-SP2) **: Possible with Monte Carlo simulation Table 3 Comparison of the characteristics of the radiochromic film method and the twodimensional dose distribution measurement system Page 21 of 38

Page 22 of 38

Images for this section: Fig. 0: Dose calibration of the PA-32 using the Xi as the reference dosimeter Page 23 of 38

Fig. 0: Comparison of the measured beam profiles between GAFCHROMIC film and the PA-32 (for a beam width of 32 mm) Page 24 of 38

Fig. 0: Comparison of the measured beam profiles between GAFCHROMIC film and the PA-32 (for a beam width of 16 mm) Page 25 of 38

Fig. 0: Comparison of the measured beam profiles between GAFCHROMIC film and the PA-32 (for a beam width of 8 mm) Page 26 of 38

Fig. 0: Comparison of the beam profiles between the four tube voltage settings measured using the PA-32 (for a beam width of 32 mm) Page 27 of 38

Fig. 0: Two-dimensional dose distributions obtained at various tube currents 120 kv (5.56 mmal), focus: large, bow tie filter: large, beam width: 32 mm Left upper: Tube current: 50 ma Right upper: 75 ma Left lower: 100 ma Page 28 of 38

Fig. 0: Two-dimensional dose distributions obtained at various acquisition speeds 120 kv (5.56 mmal), 75 ma, focus: large, bow tie filter: large, beam width: 32 mm Left upper: Acquisition speed: 6.7 m/s Right upper: 10.0 m/s Left lower: 16.0 m/s Page 29 of 38

Fig. 0: Two-dimensional dose distributions obtained with the large and small bow tie filters 120 kv, 75 ma, focus: large, beam width: 32 mm Left: Bow tie filter: Large 5.56 mmal Right: Small 6.83 mmal Page 30 of 38

Fig. 0: Two-dimensional dose distributions obtained at various tube voltages 75 ma, focus: large, bow tie filter: large, beam width: 32 mm Left upper: Tube voltage: 80 kv Right upper: 100 kv Left lower: 135 kv Page 31 of 38

Conclusion 5. Conclusion A dosimeter for measuring the two-dimensional dose distribution using a semiconductor detector has been developed. Compared with the film method, this fully digital method allows real-time dose distribution measurements to be obtained easily and repeatedly. This dosimeter could be very useful for quality control and also for Monte Carlo simulations in CT that require information about dose distribution. Appendix Creating the dose conversion table for radiochromic film using ADCT In the film method, a table for converting the film density to the dose must be created. Although a general-purpose X-ray system is generally employed, the ADCT scanner was used to create the table for dose calibration as described in subsection 2.1.2. Figure A-1 on page 34 shows the geometric layout, and Fig. A-2 on page 34shows the external appearance. The Xi was used as a field dosimeter. A sheet of GAFCHROMIC film (XR-SP2) was cut into pieces measuring 30 mm 25 mm. The Xi and XR-SP2 film were shifted 35 mm toward the anode from the central axis of rotation, where the dose distribution is maintained at a constant level. The maintenance mode of the Aquilion ONE scanner was used to generate X-rays with the X-ray tube fixed at 0. The exposure conditions were a beam width of 160 mm, the large bow tie filter, and a tube voltage of 120 kv. Considering that the maximum value is 5 cgy according to the product data (performance table) of the XR-SP2 film, the tube current time (tube current-time product [ma]) was adjusted in five levels as required. X-rays were generated for the Xi and XRSP2 film under each set of exposure conditions. After exposure, the GAFCHROMIC film was placed in a light-tight box and stored at room temperature (24 C) for 48 hours. A flatbed scanner (ES-10000G, EPSON, Japan) was used to scan the films. The scanner settings were a 16-bit gray scale, a resolution of 120 dpi, and a scan range of 40 mm 40 mm. The scanned images were saved in TIFF format. The images were analyzed using ImageJ (reference 4). An ROI measuring 200 pixels 200 pixels (13 mm 13 mm) was placed at the center of each acquired image to measure the pixel values (PV m). In a similar manner, the pixel values in images in which X-rays were not generated (PV bg) were measured. PV net was obtained by subtracting PV bg from PV m. Page 32 of 38

Figure A-3 on page 35 shows the relationship between PV net and the dose in air. The relationship between PV net and the dose in air was found to be nonlinear. Regression analysis using the least-squares method showed that the regression formula was y = -5 3-3 2-2 -2 (5 10 )x + (2.2 10 )x + (4.17 10 )x - 3.06 10 and the coefficient of determination 2 was R = 0.9997. Page 33 of 38

Images for this section: Fig. 0: Geometric layouts for creating the dose conversion table for the radiochromic film Page 34 of 38

Fig. 0: Creating the dose conversion table for the radiochromic film Back: Xi (Unfors, Sweden) Front: XR-SP (IPS, USA) Page 35 of 38

Fig. 0: Dose conversion table for GAFCHROMIC film Page 36 of 38

References 1. IEC 2002 Medical electrical equipment: Part 2-44. Particular requirements for the safety of x-ray equipment for computed tomography IEC 60601-2-44. 2. Nagel HD: Radiation Exposure in Computed Tomography (4th Revised Updated Edition), CTB, Hamburg 2002. 3. Geleijns J, Salvadó Artells M, de Bruin PW, Matter R, Muramatsu Y, McNitt-Gray MF: Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner. Phys Med Biol 2009 May 21;54(10):3141-59. 4. ImageJ 1.42: http://rsb.info.nih.gov/ij/. 5. Geleijns J: Performance evaluation for new-technology CT systems 256-channel CT, AAPM 49th Annual Meeting, July 22-26, 2007, http://www.aapm.org/meetings/07am/?general=o#menu. Page 37 of 38

Personal Information Yoshihisa Muramatsu, Ph.D., R.T. International Medical Center of JAPAN http://www.imcj.go.jp/english/index.html Department of Radiology Page 38 of 38