ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

Similar documents
ORTEC ORTEC. Modular Pulse- Processing Electronics. What s in this Catalog? Who Needs this Catalog?

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

Gamma Spectrometer Initial Project Proposal

Summary. Introduction

Comparisons Between Digital Gamma-Ray Spectrometer (DSPec) and Standard Nuclear Instrumentation Methods (NIM) Systems

M. K. Schultz, R. M. Keyser, R. C. Trammell, and D. L. Upp

Electronic Instrumentation for Radiation Detection Systems

Keyser, Ronald M., Twomey, Timothy R., and Bingham, Russell D. ORTEC, 801 South Illinois Avenue, Oak Ridge, TN 37831s

Purpose This experiment will use the coincidence method for time correlation to measure the lifetime in the decay scheme of 57

ORTEC. Time-to-Amplitude Converters and Time Calibrator. Choosing the Right TAC. Timing with TACs

PX4 Frequently Asked Questions (FAQ)

ORTEC. AN34 Experiment 14 Nuclear Lifetimes and the Coincidence Method. Equipment Needed from ORTEC. Equipment Required from Other Manufacturers

Amptek Silicon Drift Diode (SDD) at High Count Rates

ORTEC Experiment 13. Gamma-Gamma Coincidence with Angular Correlation. Equipment Required

INDEX. Firmware for DPP (Digital Pulse Processing) DPP-PSD Digital Pulse Processing for Pulse Shape Discrimination

Radiation Detection Instrumentation

Digital Signal Processing for HPGe Detectors

XRF Instrumentation. Introduction to spectrometer

ORTEC. NaI-SS Radiation Search Systems V2.5

Development of New Peak Detection method for Nuclear Spectroscopy

Analog-to-Digital-Converter User Manual

IDM-200-P. High Purity Germanium (HPGe) Interchangeable Detector Module. Intelligent, Modular Solutions for Nuclear Security Monitoring Systems

Comparisons of the Portable Digital Spectrometer Systems

DEVELOPMENT OF HIGH STABLE MONITOR FOR MEASURERING ENVIRONMENTAL RADIATION

Advanced Materials Research Vol

A PC104 Multiprocessor DSP System for Radiation Spectroscopy Applications

Traditional analog QDC chain and Digital Pulse Processing [1]

Citation X-Ray Spectrometry (2011), 40(4): 2. Right final form at

NEEP 427 PROPORTIONAL COUNTERS. Knoll, Chapters 6 & 14 Sect. I & II

e t Development of Low Cost γ - Ray Energy Spectrometer

GAMMA-GAMMA CORRELATION Latest Revision: August 21, 2007

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

GAMMA-RAD5 User Manual

Energy Measurements with a Si Surface Barrier Detector and a 5.5-MeV 241 Am α Source

AMPTEK INC. 14 DeAngelo Drive, Bedford MA U.S.A FAX:

Picosecond Time Analyzer Applications in...

DSA-LX. Digital Signal Analyzer. Radiation Safety. Amplified.


CAEN Tools for Discovery

AN-DPP-003 Rev A2: Using the DP5 with HPGe USING THE DP5 WITH GERMANIUM DETECTORS

Chapter 6 Pulse Processing

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

nanomca-ii-sp datasheet

ORTEC Experiment 9. Time Coincidence Techniques Applied to Absolute Activity Measurements. Equipment Required. Purpose.

NIM. ADCs (Peak Sensing) Analog Pulse Processors Amplifiers (Fast) Amplifiers (Spectroscopy) Attenuators Coincidence/Logic/Trigger Units

Overview 256 channel Silicon Photomultiplier large area using matrix readout system The SensL Matrix detector () is the largest area, highest channel

Detecting and Suppressing Background Signal

Semiconductor Detector Systems

ORTEC Experiment 3. Gamma-Ray Spectroscopy Using NaI(Tl) Equipment Required. Purpose. Gamma Emission

nanomca-sp datasheet I. FEATURES

DEVELOPMENT OF A CHARGE-SENSITIVE PREAMPLIFIER USING COMMERCIALLY AVAILABLE COMPONENTES

A MONTE CARLO CODE FOR SIMULATION OF PULSE PILE-UP SPECTRAL DISTORTION IN PULSE-HEIGHT MEASUREMENT

The 2017 IEEE NSS-MIC. Industrial Presentation


Virtual Laboratory of Nuclear Fission Virtual practicum in the framework of the project Virtual Laboratory of Nuclear Fission

LUDLUM MODEL MODEL AND MODEL GAMMA SCINTILLATORS. June 2017

OPERATION MANUAL. Model LET-SW5. April Far West Technology, Inc. 330 South Kellogg Ave, Suite D Goleta, CA 93117

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

nanomca 80 MHz HIGH PERFORMANCE, LOW POWER DIGITAL MCA Model Numbers: NM0530 and NM0530Z

PX5 User Manual and Operating Instructions

ORTEC. High-Count-Rate Spectroscopy with Ge Detectors: Quantitative Evaluation of the Performance of High-Rate Systems 1. I.

Atomic and Nuclear Physics

CAEN. Electronic Instrumentation. CAEN Silicon Photomultiplier Kit

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

Positron Emission Tomography

TB-5 User Manual. Products for Your Imagination

NIM INDEX. Attenuators. ADCs (Peak Sensing) Discriminators. Translators Analog Pulse Processors Amplifiers (Fast) Amplifiers (Spectroscopy)

An aging study ofa MICROMEGAS with GEM preamplification

Chemical Engineering 412

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa

nanomca datasheet I. FEATURES

nanodpp datasheet I. FEATURES

COMPARISON OF A DIGITAL AND AN ANALOGICAL GAMMA SPECTROMETER AT LOW COUNT RATES

Mössbauer ~ Spectrometer. Following to our long-term experiences, we offer complete Mössbauer spectroscopy instrumental support

Amptek Inc. Page 1 of 7

DP5 User Manual and Operating Instructions

Silicon Drift Detector. with On- Chip Ele ctronics for X-Ray Spectroscopy. KETEK GmbH Am Isarbach 30 D O berschleißheim GERMANY

Range of Alpha Particles in Gas (note, this is abridged from full Nuclear Decay laboratory file)

A CMOS INTEGRATED CIRCUIT FOR PULSE-SHAPE DISCRIMINATION*

Fast first practical help -- detailed instructions will follow- preliminary Experiment F80

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy

Method for digital particle spectrometry Khryachkov Vitaly

Measuring Atlas Radiation Backgrounds in the Muon System at Startup: A U.S. ATLAS Upgrade R&D Project

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information)

Week 11: Chap. 16b Pulse Shaping

ORTEC Experiment 1. Introduction to Electronic Signal Analysis in Nuclear Radiation Measurements. Equipment Required: Purpose. Electronic Circuits

ISO-CART-85. Mobile Low-Level Waste Assay System

LONG TERM STATISTICS OF X-RAY SPECTROMETERS

COMPTON SCATTERING. Purpose. Introduction. Fundamentals of Experiment

Soft X-Ray Silicon Photodiodes with 100% Quantum Efficiency

EXPERIMENT 5. SCINTILLATION COUNTING AND QUENCH CORRECTION.

Amptek sets the New State-of-the-Art... Again! with Cooled FET

EQUIPMENT SPECIFICATIONS

Product Range Electronic Units

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Application Notes: Discrete Amplification Photon Detector 5x5 Array Including Pre- Amplifiers Board

The Influence of Crystal Configuration and PMT on PET Time-of-Flight Resolution

Real-Time Pulse-Shape Discrimination and Beta-Gamma Coincidence Detection in Field- Programmable Gate Array

Activities in Electronics Lab Associates are: Mrs. Arti Gupta, K.S.Golda, S.Muralithar & Dr.R.K.Bhowmik

Transcription:

ORTEC Spectroscopy systems for ORTEC instrumentation produce pulse height distributions of gamma ray or alpha energies. MAESTRO-32 (model A65-B32) is the software included with most spectroscopy systems and includes a control program for ORTEC hardware commonly referenced as the UMCBI. The UMCBI provides all the drivers for the various hardware MAESTRO-32 supports. MAESTRO-32 is an emulation software package that provides a histogram display for pulse heights as well as utilizing the PC for display and control functions that would normally be done in older stand alone multi-channel pulse height analyzers. Functions in MAESTRO-32 are typically designed for germanium detector spectra and functions like peak search are looking for narrow peaks found with a germanium detector not the broad peaks found with a sodium iodide [NaI(Tl)] detector. Software packages for qualitative and quantitative analysis of gamma rays are available for both germanium, sodium iodide, and alpha spectra. Specialized application software packages are also available. Processing pulse height information can be recorded in three ways. One method is where the output of an analog shaping amplifier feeds into an ADC. A second method is by using a DSP instead of an analog shaping amplifier. The detector preamplifier output is sampled, digitized, and filtered. Then the digitized information is displayed as a histogram. The third way is to list each pulse height event sequentially (List Mode). List mode requires the use of our software toolkit (Model A11-B32) to write a program for List Mode operation. Example programs are provided in the manuals of instruments that have list mode capability. Detectors High-Purity Germanium Detectors (HPGe) Germanium detectors are extremely large reverse biased diodes which include charge sensitive preamplifiers that convert the charge deposited by interacting gamma radiation into a voltage pulse which is typically filtered and amplified for display in a pulse height histogram to exhibit the energy spectrum of the gamma-rays collected. Germanium detectors are well known for their superior resolution. A typical NaI detector would have on the order of 7% resolution while an HPGe detector would have less than 0.13%. A full line of HPGe detectors is available from ORTEC including planar and coaxial configurations. HPGe detectors need to be cooled to near liquid nitrogen temperatures to operate. HPGe detectors far exceed any other detector type for gamma-ray resolution. HPGe technology has grown extensively over the past ten years. Today both laboratory and field units are available with full analysis capability with either liquid nitrogen or with refrigeration cooling systems. Thallium Activated Sodium Iodide [NaI(Tl)] Detectors NaI(Tl) detectors incorporate a NaI(Tl) crystal mounted on a photomultiplier tube (PMT). The NaI(Tl) crystal emits a flash of light proportional to the energy of the gamma ray that interacts with the crystal. The PMT detects this light and amplifies the detected light to yield a proportional quantity of charge. This charge is converted into a voltage pulse by a charge sensitive preamplifier. The pulse can be discriminated by a window type (upper and lower level) Single Channel Analyzer (SCA) and then counted, or these pulses can be displayed as a histogram of pulse heights representing a spectrum of energy. Other Scintillator detectors are available today such as BGO, CsI, Fast Plastic, etc. Halide detectors have resolutions about twice as good as NaI detectors (around 3%) which make this an attractive detector for some applications. It is important to note that HPGe detectors still have more than 20 times better resolution than the halides can provide. Alpha Detectors Alpha detectors are charged-particle silicon crystal diodes that come in various active diameters. There are two types of detectors for alphas. The Ultra series detectors have an ion-implanted front contact that gives a very thin (~500 Angstrom silicon equivalence) front contact and these have passivated leakage surfaces. These detectors are available as low background (designated as AS ) detectors that will fit into ORTEC vacuum chambers. Ultra series detectors require positive bias voltage. The ruggedized or R series detectors are made with metal evaporated contacts and have a contact thickness on the order of ~2300 Angstroms silicon equivalence. These detectors have epoxy covered leakage surfaces. These detectors are available as low background (designated as SNA ) detectors that will fit into ORTEC vacuum chambers. R-series detectors require negative bias voltage. Processing Electronics Preamplifiers HPGe detectors come with a charge-sensitive preamplifier that integrates the charge from the gamma-ray interaction in the detector crystal onto a capacitor in the feedback circuit. Either a parallel resistor or a reset switch (transistor or LED diode switch) discharges the capacitor. NaI (Tl) detectors use a charge-sensitive preamplifier that is stand-alone or incorporated into the PMT base. Alpha detectors also use a charge-sensitive preamplifier that is stand-alone or incorporated into the alpha system.

Analog Shaping Amplifiers Shaping amplifiers have a selectable shaping time, t. (2.2 X t = risetime) which shapes the detector pulses for best resolution or throughput, a pole zero circuit that allows the pulse to return to base line long before the actual preamplifier charge pulse does, and a base line restorer circuit to insure a consistent reference for the pulse heights. Some shaping amplifiers incorporate logic to account for preamplifier reset time, pulse processing time, and pile-up rejection circuits to correct for dead times that the amplifier processing produces. See the Amplifier section for more information. Multi-Channel Analyzers Multi-Channel Analyzers take their input from an analog amplifier and digitize the incoming pulse heights placing the accumulated data into memory and displaying this pulse height distribution in a historgram. The histogram X-axis is the pulse height and the Y-axis is the number of counts. Today s Multi-Channel Analyzers typically consist or a Multi-Channel Buffer (MCB) which has an Analog-to- Digital Converter (ADC) and a histogramming memory that can be interfaced to a PC for display. Software (MAESTRO-32 model A65- B32) is required to run the MCB units using the computer to make a complete Multi-Channel Analyzer. The interface to the PC can be either by thinwire ethernet, parallel printer port, dual port memory, or USB. The number of channels in the ADC can determine the digital resolution which should be chosen to suit the detector type and energy range. Signal processing does take time and the time the system is available to receive a signal is considered Live Time while all the time consumed with signal processing is Dead Time. MCA systems can receive logic signals to determine this Dead Time in order to insure any quantitative data is correct. DSP Units Digital Signal Processor (DSP) units replace the functions of the analog shaping amplifier and the MCB. These DSP units also use MAESTRO-32 software (included with all DSP models). DSP units typically receive a signal with a specific shape from the preamplifier. This signal is sampled and the resulting digital number is processed to provide a much larger range of shaping parameters than an analog amplifier can provide. The functions of gain, baseline restorer, pole zero, and dead time logic functions are still performed in the DSP. Since the data is already digitized an ADC is not required. A histogram is typically made for display on the PC. The DSP units interface with a PC either with a dual port interface, a thinwire ethernet interface or a USB interface (see the individual data sheets for details). Examples Figures 1 through 8 show systems for pulse-height spectrometry with a variety of detector types. The following types are included: Microchannel plate detector (Fig 1). Microchannel plate photomultiplier tube (Fig. 1). NaI(Tl) scintillation detector (Fig. 2). Conventional photomultiplier tube (Fig. 3). Proportional counter (Fig. 4). Silicon charged-particle detector (Fig. 5). Si(Li) detector (Fig. 6, 7 and 8). Ge detector (Figs. 6, 7, and 8). If nuclear or x-ray radiation is being detected, the pulse-height is usually calibrated in terms of the energy of the radiation. Hence the term energy spectroscopy is used. For other types of signal sources, the pulse height simply represents the charge deposited in the detector by the event. Consequently, the measurement process can be considered to be either charge or pulse-height spectrometry. In Figures 1, and 3 through 7, a preamplifier integrates the charge deposited in the detector, an amplifier shapes the pulses for pulseheight measurement, and a multichannel buffer (ADC plus memory) sorts the pulse heights into a spectrum (histogram of energy versus counts). Figure 2 uses an integrated package complete with preamplifier, high voltage supply, and a digital signal processor all powered by the USB interface to the PC. In Figure 4, the low-noise 142PC Preamplifier has about a factor of 6 higher sensitivity than the standard 142IH Preamplifier. This higher sensitivity allows operation of the proportional counter at a lower gas gain. The benefit is less dependance of the gas gain on counting rate in the proportional counter. As a result, the proportional counter can be operated at higher counting rates before peak shifting occurs in the recorded energy spectrum. In Figure 6, connection of the BUSY and PUR signals between the amplifier and MCB is essential for achieving accurate dead time correction with the Gedcke-Hale Live-Time Clock in the MCB. 2

Figures 2, 7 and 8 show the use of an integrated electronics package for x-ray or gamma-ray spectrometry. In this case the preamplifier output is sampled and our digital systems provide digital signal processing for improved performance. Fig. 1. Pulse-Height (Charge) Spectroscopy with a Microchannel Plate (µcp) Detector, or a Microchannel Plate Photomultiplier Tube (µcp PMT). Fig. 2. Pulse-Height (Energy) Spectroscopy with a NaI(Tl) Scintillation Detector Fig. 3. Pulse-Height (Charge) Spectroscopy with a Photomultiplier Tube. Fig. 4. Pulse-Height (Energy) Spectroscopy with a Proportional Counter. 3

Fig. 5. Pulse-Height (Energy) Spectrometry with a Si Charged-Particle Detector, Including Derivation of an Optional Timing Signal. Fig. 6. Pulse-Height (Energy) Spectroscopy with a Ge Detector for Gamma Rays, or a Si(Li) Detector for X Rays. Fig. 7. Pulse-Height (Energy) Spectroscopy with a Ge Detector for Gamma Rays, or a Si(Li) Detector for X Rays, Using Digital Signal Processing (DSP). 4

Fig. 8. Pulse-Height (Energy) Spectroscopy with a Ge Detector for Gamma Rays, or a Si(Li) Detector for X Rays, Using Digital Signal Processing (DSP). *DSPec jr 2.0, DSPec jr, or digidart may also be used. ORTEC www.ortec-online.com Tel. (865) 482-4411 Fax (865) 483-0396 ortec.info@ametek.com 801 South Illinois Ave., Oak Ridge, TN 37831-0895 U.S.A. For International Office Locations, Visit Our Website Specifications subject to change 071309 5