Electrical Temperature Measurement

Similar documents
Resistance Thermometers Model Series TR7X0, Sheathed Design

In-Line Resistance Thermometers Model TR25

In-Line Resistance Thermometers Model TR472

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR30, compact design

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Model TR33, thread-mounted

In-line resistance thermometer Model TR25

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR31, miniature design

Resistance thermometers for process technology

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Field indicator for current loops with HART communication Models DIH50, DIH52

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

OPTITEMP TT 10 C/R Technical Datasheet

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Omnigrad S -TR63. Technical Information

HART field temperature transmitter Models TIF50, TIF52, TIF62

OPTITEMP TT 20 Technical Datasheet

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Mineral-insulated resistance thermometers to EN

SITRANS T measuring instruments for temperature

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Field indicator for current loops with HART communication Models DIH50, DIH52

Features and benefits The Omnigrad S TC62 is an industrial thermometer (thermocouple

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Screw-in resistance thermometers with terminal head Form B

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Series RTD (Resistance Temperature Detector) Code: JT

Submersible pressure sensor For oils and fuels Model LF-1

itemp PA TMT184 Technical information

Omnigrad S -TR61. Technical Information

Design and applications

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

KFS. Flap-type flow meter. Design and range of application

OPTIFLUX 5000 Technical Datasheet

Submersible pressure sensor For water and wastewater Model LW-1

omnigrad M TR 46 Technical Information Hygienic in-line RTD thermometer PCP ( ma), HART or PROFIBUS-PA electronic

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Positioner with HART Communication Type 3780

OEM radar transmitter, for aggressive media level measurement

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Temperature Measurement

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Installation guide 971 SmartRadar LTi

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Coriolis Massflowmeter

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Coriolis Massflowmeter

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Screw-in resistance thermometers with plug connector

Rosemount 148 Temperature Transmitter

Submersible pressure sensor For superior applications Model LF-1

SATRON VB Pressure Transmitter

Omnigrad S TR66. Technical Information. Modular RTD assembly, flameproof Barstock thermowell, with thread or flange

SALES SERVICE +358 (0)

Explosion-Proof ORDER ODES HN 94, T- R1T1 5 4

Temperature Transmitters TMT 136, TMT 137

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Pressure transmitter for general industrial applications Model A-10

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Full Metal Variable Area Flowmeter and Counter Model BGF

CombiTemp TCR6 Standard RTD temperature sensor

Temperature Input Module for Zone 1 Series 9482/32

Temperature Sensor with Thread G1/4" FLEXadapt

Valve Island with Electronic I/O

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Rod probe With coaxial tube reference probe

Temperature Transmitter itemp RTD DIN rail TMT 127

Transcription:

Electrical Temperature Measurement Resistance Thermometers Model TR10-B, for Additional Thermowell Applications Machinery, plant and tank construction Energy and power plant technology Chemical industry Food and beverage industry Sanitary, heating and air-conditioning technology Special Features Application ranges from -200 C... +600 C To assemble with all standard thermowell designs Spring-loaded measuring insert (exchangeable) Explosion-protected versions Ex-i, Ex-n and NAMUR NE24 Description Resistance thermometers in this series can be combined with a large number of thermowell designs. Operation without thermowell is only recommended for specific applications. An extensive range of sensors, connection heads, insertion lengths, neck lengths, thermowell connections etc. are available for these thermometers, so that they are suitable for all thermowell dimensions and applications. Intrinsically safe designs are available for applications in hazardous areas. The models of the TR10-B series are provided with a typeexamination certificate for intrinsically safe type of protection according to directive 94/9/ EC (ATEX) for gases and dust. Manufacturer s Declarations in accordance with NAMUR NE24 are also available. Resistance Thermometer for Additional Thermowell, Model TR10-B Optionally we can fit analogue or digital transmitters from the Parker range into the connection head of the TR10-B.

Sensor The sensor is located in the measuring insert, which is exchangeable and spring-loaded. Sensor method of connection 2-wire The lead resistance of the measuring insert compounds the error. 3-wire With a cable length of approx. 30 m or longer measuring deviations can occur. 4-wire The inner lead resistance of the connecting wires is negligible. Sensor limiting error Class B to DIN EN 60 751 Class A to DIN EN 60 751 1 3 DIN B at 0 C It makes no sense to combine 2-wire connection with class A or 2-wire connection with 1 3 DIN B, because the lead resistance of the measuring insert, over-rides the higher sensor accuracy. Basic values and limiting errors Basic values and limiting errors for the platinum measurement resistances are laid down in DIN EN 60 751. The nominal value of Pt100 sensors is 100 Ω at 0 C. The temperature coefficient Ω can be stated simply to be between 0 C and 100 C with: α = 3,85 10-3 C-1 The relationship between the temperature and the electrical resistance is characterised by polynomials which are defined in DIN EN 60 751. Furthermore, this standard lays down the basic values in C stages. Class Limiting error in C A 0.15 + 0.002 t 1) B 0.3 + 0.005 t Error in C Temperature Basic value Limiting error DIN EN 60 751 (ITS 90) Class A Class B 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 C Ω C Ω C Ω -200 18.52 ± 0.55 ± 0.24 ± 1.30 ± 0.56-100 60.26 ± 0.35 ± 0.14 ± 0.80 ± 0.32-50 80.31 ± 0.25 ± 0.10 ± 0.55 ± 0.22 0 100.00 ± 0.15 ± 0.06 ± 0.30 ± 0.12 50 119.40 ± 0.25 ± 0.10 ± 0.55 ± 0.21 100 138.51 ± 0.35 ± 0.13 ± 0.80 ± 0.30 200 175.86 ± 0.55 ± 0.20 ± 1.30 ± 0.48 300 212.05 ± 0.75 ± 0.27 ± 1.80 ± 0.64 400 247.09 ± 0.95 ± 0.33 ± 2.30 ± 0.79 500 280.98 ± 1.15 ± 0.38 ± 2.80 ± 0.93 600 313.71 ± 1.35 ± 0.43 ± 3.30 ± 1.06 class B in C class B in Ω class A in C class A in Ω -200-100 0 100 200 300 400 500 600 Temperature in C 1.75 1.5 1.25 1.0 0.75 0.5 0.25 0 Error in Ω 3163008.01 1) t is the value of the temperature in C without consideration of the sign TR10-B components Fig. with parallel thread, conical thread see page 5 Legend: 3160 645.06 1 2 3 4 5 Connection head Neck tube Connection to thermowell Measuring insert Transmitter (option) A (l1) Insertion length l5 Measuring insert length N (MH) Neck length

Connection head BS BSZ BSZ-K BSZ-H BSZ-HK BSS BSS-HB VA Model Material Cable entry Ingress protection Cap Surface finish BS Aluminium M20 x 1.5 1) IP 65 Cap with 2 screws blue, painted 2) BSZ Aluminium M20 x 1.5 1) IP 65 Flap cap with screw blue, painted 2) BSZ-K Plastic M20 x 1.5 1) IP 65 Flap cap with screw BSZ-H Aluminium M20 x 1.5 1) IP 65 Flap cap with screw blue, painted 2) BSZ-HK Plastic M20 x 1.5 1) IP 65 Flap cap with screw BSS Aluminium M20 x 1.5 1) IP 65 Flap cap with clip blue, painted 2) BSS-H Aluminium M20 x 1.5 1) IP 65 Flap cap with clip blue, painted 2) BVA Stainless steel M20 x 1.5 1) IP 65 Screw cover blank 1) Standard 2) RAL5022, polyester paint saltwater-proof Connection head with digital indicator (option) As an optional alternative to the standard connection head the thermometer may be equipped with the digital indicator DIH10. The connection head used in this case is similar to the head model BSZ-H. For operation a 4... 20 ma transmitter is necessary, which is mounted to the measuring insert. The scale range of the indicator is configurated identical to the measuring range of the transmitter. Intrinsically safe versions, explosion protection type EEx (i), are also available. Fig. Connection head with digital indicator, Model DIH10 Transmitter (option) Depending on used connection head a transmitter can be mounted into the thermometer. Mounted instead of terminal block Mounted within the cap of the connection head Mounting not possible Mounting of 2 transmitters on request. Order chart 1 Connection head Transmitter Model T12 T19 T24 T32 T53 BS - - BSZ / BSZ-K BSZ-H / BSZ-HK BSS BSS-H BVA Model Description Explosion protection Data sheet T19 Analogue transmitter, configurable without TE 19.03 T24 Analogue transmitter, PC-configurable optional TE 24.01 T12 Digital transmitter, PC-configurable optional TE 12.03 T32 Digital transmitter, HART protocol optional TE 32.03 T53 Digital transmitter FOUNDATION Fieldbus and PROFIBUS PA standard TE 53.01

Neck tube The neck tube is screwed to the connection head. The usual size to industrial standards is M24 x 1.5 mm. The length of the neck tube depends on the application. Generally the neck tube serves for the bridging of an insulation. In many applications it is also used as a part cooling element between connection head and medium in order to protect any head mount transmitters from high medium temperatures. Standard material of the neck tube is stainless steel. Measuring insert The measuring insert is made of a vibration-resistant sheathed measuring cable (mineral-insulated cable). The diameter of the measuring insert shall be approx. 1 mm smaller than the hole diameter of the thermowell. Gaps of more than 0.5 mm between thermowell and measuring insert will have a negative effect on the heat transfer, and they will result in an unfavourable response behaviour of the thermometer. When fitting the measuring insert with a thermowell, it is very important to determine the correct insertion length (= thermowell length with bottom thicknesses of 5.5 mm). In this connection the fact that the measuring insert is spring-loaded (spring travel: max. 10 mm) has to be taken into account in order to ensure that the measuring insert presses against the bottom of the thermowell. Furthermore we recommend that a neck length be selected to give a standard length for the thermometer's measuring insert. This has the advantage that a measuring insert of the Order chart 2: Standard measuring insert lengths Measuring insert Ø in mm Standard measuring insert lengths in mm 3 275 315 375 435 6 275 315 345 375 405 435 525 555 585 655 735 8 275 315 345 375 405 435 525 555 585 655 735 The lengths specified in this table correspond to the standard lengths. Intermediate lengths or excess lengths are possible without any problems. Possible combinations of measuring insert diameter, number of sensors and sensor method of connection Measuring insert Ø in mm Sensor / method of connection 1 x Pt100 Sensor / method of connection 2 x Pt100 2-wire 3-wire 4-wire 2-wire 3-wire 4-wire 3 x x x x x - 6 x x x x x x 8 x x x x x x Order chart 3: Possible combinations of design, neck tube diameter and connection thread Design of the screw connection at the Connection thread at neck tube Connection tread to the head neck tube Ø 12 mm Order No Ø 14 mm Order No Male thread G ½ B 1 G ½ B 11 M24 x 1.5 G ¾ B 2 G ¾ 12 M24 x 1.5 M14 x 1.5 3 - M24 x 1.5 M18 x 1.5 4 M18 x 1.5 13 M24 x 1.5 ½ NPT 5 ½ NPT 14 M24 x 1.5 ¾ NPT 6 ¾ NPT 15 M24 x 1.5 Union nut G ½ 7 G ½ 16 M24 x 1.5 M27 x 2 8 M27 x 2 17 M24 x 1.5 Male nut G ½ B 9 G ½ B 18 M24 x 1.5 Neck tube without thread - - M24 x 1.5 Neck tube with compression fitting G ½ B 10 G ½ B 19 M24 x 1.5 M27 x 2 11 M27 x 2 20 M24 x 1.5 Explosion protection (option) Resistance thermometers of the Model series TR10-B are available with a type-examination certificate for "intrinsically safe" ignition protection (TÜV 02 ATEX 1793 X). These thermometers comply with the requirements of directive 94/9/EC (ATEX), EEx-i, for gases and dust. Manufacturer s Declarations in accordance with NAMUR NE24 are also available. The classification / suitability of the instrument (permissible power Pmax., minimum neck length and permissible ambient temperature) for the respective category can be seen on the type-examination certificate and in the operating instructions. Built-in transmitters have their own approval. The permissible ambient temperature ranges of the built-in transmitters can be taken from the corresponding transmitter approval. The responsibility for using suitable thermowells rests with the user.

Connection to thermowell The many possible designs ensure that the resistance thermometer, Model TR10-B, can be combined with almost all feasible thermowells. The most usual designs of connection are shown in the following drawings. Others are available on request. 3160688.05 3160670.05 Male thread Neck tube with compression fitting (positional) Nipple-Union- Nipple Legend: A (l1) Insertion length (with cylindrical threads) A (U2) Insertion length (with conical threads) l5 Measuring insert length N (MH) Neck length Ø F1 Neck tube Ø Ø d Measuring insert Ø KE Screw-in length by hand - with ½ NPT approx. 8.1 mm - with ¾ NPT approx. 8.6 mm

Electrical connection 1 x Pt100, 2-wire 1 x Pt100, 3-wire 1 x Pt100, 4-wire 3160 629.06 2 x Pt100, 2-wire 2 x Pt100, 3-wire 2 x Pt100, 4-wire

Ordering information - Part Number Configurator Part Code Connection Senor limiting error Connection head Transmitter Neck length Neck tube connection thread Example TR 1 x PT100 1 BS T12 3 1 1 x PT100 2 wire = 1 3 wire = 2 4 wire = 3 2 x PT100 2 wire = 4 3 wire = 5 4 wire = 6 BS BS2 BSK BS2-H BS2-HK BSS BSS-H BUA T12 T19 T24 T32 T53 (see order chart 1 on page 3) Enter length in mm (see order chart 2 on page 4) Enter connection thread (see order chart 3 on page 4) Class A = 1 Class B = 2 DIN B at C = 3 Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. 2008 Parker Hannifin Corporation. All rights reserved. Parker Hannifin Ltd. Instrumentation Products Division, Europe Riverside Road, Pottington Business Park, Barnstaple, Devon, EX31 1NP United Kingdom Tel.: +44 (0) 1271 31 31 31 Fax: +44 (0) 1271 37 36 36 www.parker.com/ipd CATALOGUE REF: 3010-ET1