Free Standing Pedestal Mounting Installation Manual

Similar documents
Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Pega 357 with Fanuc 04PC User Pre-installation Guide

Pega 345 Queen with Fanuc 04PC User Pre-installation Guide

Pega 367 with Fanuc 04PC User Pre-installation Guide

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

OWNER'S MANUAL TIE ROD, WALL & FLOOR MOUNTED JIBS. Model JIB-HC, JIB-LC, JIB-FM

18000 HDL FOUR POST LIFT LB CAPACITY INSTALLATION AND OWNER'S MANUAL

Assembly Instructions

INSTALLATION INSTRUCTIONS FOR HAND OPERATED MODELS: 170, 171-R, 171-N, 172, 260

Installation, Operation and Maintenance Manual. RB Weir Gate

Umbrella Inserts and Stubby Screens

STRATUS SHELTER. Take bike parking to new heights

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

MOR/ryde Steer Axle Suspension System

Vipros 357 User Pre-installation Guide

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

INSTALLATION GUIDE. Version 2.0

Large Diameter Tapcon

INSTALLATION MANUAL IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA MANUAL PART NUMBER:

C4 Fabrication Rock Slider Installation 14+ 5th Gen 4Runner w/o KDSS

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

SUBSTATION SECURITY WALL INSTALLATION MANUAL

Please be sure to read this manual before using the product.

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

ATTENTION. 4. Do not over tighten the hydraulic fittings. This will cause leakage and will not be covered under warranty.

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

Vipros 357 Queen User Pre-installation Guide

Click Here to Go Back

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Pole Mount Installation Guide

w w w. h d o n l i n e s h o p. d e TIMKEN BEARING CONVERSION TOOL GENERAL INSTALLATION -J04672 REV Kit Number Models

Rhino SD2/XD2 Mini Tote Conversion Kit

CONTROLS KIT FOR ALL # & # HARLEY DAVIDSON SPORTSTER MODELS

1. VERIFY ALL COMPONENTS

Midwest Roadside Safety Facility

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

Installation Instructions

Mount to the Wall INSTALLATION MANUAL

INDEX PAGE RELEASE SECTION NUMBER DATE

CM543 STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Removing Right-Side. Components. Right-Side. Components. Click Here to Go Back AT THIS POINT

CSS Central Mount System

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

One Piece LSD/Vector Pads from TIE DOWN ENGINEERING Easier installation with 70% fewer parts Lower cost with competitive pricing

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

BISON GOOSENECK FOOTBALL 1 PAIR OF GOAL POSTS

Straight Stringer Installation Instructions

BEST PRACTICE GUIDE. Socket Bases. Working with Concrete Slabs

Installation Instruction

Dual Arm Tilt LCD Mount

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

KOLO SHELTER Installation Instructions Parts List

Model : TLX-350FM. TV Mount Installation Guide

Technologies, Inc. Installation Instructions for Anchors & Components. Rev PAGE 1 / 11

Umbrella Inserts and Stubby Screens

TK 1014 A POWER SHEAR

REVIEW ALL INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING INSTALLATION

Hardened Structures Hardened Shelters, LLC. Explosion Resistant Pre-hung Sealed Blast Door

Removing the Z-Axis lead screw

Letter of Transmittal/Submittal

PFW Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

EURO DELUXE INSTALLATION INSTRUCTIONS

DO35 MAINTENANCE INSTRUCTIONS

Installation Instructions for Solar Snow Pad (SSP-T-3)

Arc Trainer Main Frame Assembly

ASSEMBLY INSTRUCTIONS DIY WALL BED KIT QUEEN BI FOLD DOOR CABINET & MECHANISM. Tools Required For Assembly. 6.5mm Masonry Drill Bit

INSTALLATION INSTRUCTIONS CHAIN-LINK FENCE AND GATE

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring

HEAVY DUTY WEIGH FEET KIT. Installation Instructions

E4-WM5-Y542A00 MOUNTING INSTRUCTION

New Product Release: October 2014 Boone Racks

Due to possible damage in shipping, the vertical stop assembly has been removed from this machine.

Baseball Backstopper System

Installation Instructions for FC2 & FC15 Forward Controls for the Super Magna

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

Installing a COMROD AS1R Whip Antenna with Anchor Post

Assembly Instructions

Block Foundation. From the 1950s through the 80s. Hydraulically driven. piers provide bearing. for a settling foundation

Spring Loaded All Season Roll-Up Doors

KEEP YOUR RESOURCE MOVING.

6o ft (18.3 m) Southwest Windpower, Inc West Route 66 Flagstaff, Arizona USA Phone: Fax:

Assembly, Installation, Operation and Maintenance Instructions Kit, Base Rail Bracket Part # 31852

LC200DS2 Double Stud Dual Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

MODEL 200/220 ASSEMBLY INSTRUCTIONS

Installing CNC Stepper Motor Mounts On A Sherline Lathe

3 Emergency Breakaway Coupling

Referencing 0,0 position

Pickup Box Utility Rack Package Installation (Instruction ID: )

1.8 METER SERIES 1194 ANTENNA SYSTEM

PREPARATION & TOOL CHECK LIST

Installation and Assembly: Full Service Video Wall Mount

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Equilibrium Credenza

Instruction Sheet For: SCM-2

Transcription:

Free Standing Pedestal Mounting Installation Manual Articulated Jib Crane KickLIFT Page 1 of 5

INSTALLATION GENERAL INSTALLATION INSTRUCTIONS All AIMCO lift assist equipment and associated tooling is assembled and tested at the factory. ARTICULATED JIB CRANE REQUIREMENTS Foundation: For a 500lbs capacity @ 15 (7500 ft-lbs) SAJ, a 6 slab (minimum f c> 3,500 psi) may be utilized provided it meets the following conditions. - Slab must be a slab-on-grade supported by soil with an allowable bearing pressure greater than 1,000 pounds per square foot. - Concrete must be in sound condition devoid of any cracks, spalling, deterioration, etc. within a 10-0 x 10-0 square area (jib mast centered on this area). - Six (6) anchors on a 27 bolt circle must develop an un-factored tension greater than 3,300 pounds each. This may be obtained with a minimum 3/4 diameter Hilti HAS E-rod with a minimum 4 1/4 embedment. - Bottom of anchor not to be within (2*(diameter+1/8 )) from the bottom of the slab. 10-0 square area must be clear of additional equipment and/or fork truck traffic. For 865lbs capacity @ 15 (13,000 ft-lbs) HAJ, an 8 slab (minimum f c> 3,500 psi) may be utilized provided it meets the following conditions. - Slab must be a slab-on-grade. - Concrete must be in sound condition devoid of any cracks, spalling, deterioration, etc. within a 10-0 x 10-0 square area (jib mast centered on this area). - Six (6) anchors on a 27 bolt circle must develop an un-factored tension greater than 4,700 pounds each. This may be obtained with a minimum 3/4 diameter Hilti HAS E-rod with a minimum 5 embedment. - Bottom of anchor not to be within (2*(diameter+1/8 )) from the bottom of the slab. 10-0 square area must be clear of additional equipment and/or fork truck traffic. Note: If neither of the two above conditions can be met, or if a factor of safety above 3 to 1 is desired then a dedicated jib foundation (5ft x 5ft x 4ft deep) must be poured. Temperature Limits: - Your articulated jib crane should be installed where it is not subject to radical changes in temperature or temperatures outside of the limits listed below. Temperatures outside of the recommended limits may cause problems with bearings, pneumatic systems, moving parts and tooling. - Unless otherwise specified, AIMCO equipment is designed for indoor use only. Minimum Temperature 40 degrees Fahrenheit Maximum Temperature +140 degrees Fahrenheit Air Supply: All foundation requirements assume concrete was installed per the ACI 318 Building Code Requirements for Structural Concrete. Consult a qualified structural engineer if you deviate from the recommended specifications listed below. - Clean, dry air (90 PSI minimum). It is recommended that a filter regulator be placed between the incoming Page 2 of 5

INSTALLATION Pedestal Pedestal must be level to prevent the articulated jib arms from drifting. AIMCO Pedestal mounting for: SAJ & HAJ Series FIG-1 A.) Mount the pedestal on a level, appropriately sized concrete foundation. B.) The pedestal must be leveled prior to securing to the floor. Level across the top mounting plate (See Fig-3). C.) Shim stock beneath the pedestal mounting plate may be used to aid leveling the pedestal (See Fig-3). D.) Position the pedestal on the foundation with the supply air intake cover positioned to minimize piping. E.) Recommendation only! Use 3/4" Concrete Anchors (provided by others) to mount the pedestal. Consult structural engineer for concrete anchor recommendations. Supply Air Intake Cover FIG-3 AIMCO Pedestal mounting for: BAJ & VAJ Series FIG-2 Top Mounting Plate Shim under Pedestal Mounting Plate. If shim(s) exceed 1/8 thickness, fill gaps with high strength grout. Page 3 of 5

INSTALLATION Articulated Jib F.) Assure the 1/2" push to connect fitting is securely connected to the bottom of the primary bearing housing. G.) Fold back the secondary arm beneath the primary arm (as shown in Fig-4). Tie the two arms together to prevent them from unfolding during lifting. Using a forklift, spread the forks and place them between the primary and secondary arm so that the load is lifted from the bottom side of the primary arm. Secure the arms to the forks with "C" clamps prior to lifting overhead. Primary Bearing Housing 1/2" Air Line Primary Arm FIG-4 H.) Route the 1/2" airline down through the pedestal and out of the hole located on the side of the pedestal (See Fig-4). I.) Slowly lower the arms onto the top of the pedestal, aligning the bolt holes. Secure the arms to the pedestal with 6 bolts from the accessory box. (Bolts will vary between series of articulated jibs) Torque bolts using the chart shown in Fig. 4. NOTE: It is recommended that LocTite threadlocker be used for this connection. J.) Connect the 1/2" airline to the 1/2" push to connect fitting and secure the 1/2" NPT female fitting plate to the pedestal using the 1/4-20 SHCS provided. Secondary Arm Mounting Hardware (Included with shipment) 1/2" Push to Connect Fitting 1/2" NPT Female Fitting K.) System Power: Clean, dry air (90 PSI minimum). It is recommended that a filter regulator be placed between the incoming L.) Carefully rotate the jib crane to ensure clearance between jib arms and the surrounding areas. M.) If stud anchors are used at the Pedestal Base, cut-off excess thread above the nut so that 2-3 threads are exposed above the nut; 6 places. Do Not Over tighten Bolts: Over tightening will result in higher pull forces. SHCS Bolt Size 1/2-13 110 5/8-11 210 3/4-10 380 Torque Ft.-Lbs. Page 4 of 5

INSTALLATION KickLIFT N.) Assure the 1/2" push to connect fitting is securely connected to the bottom of the primary bearing housing. Primary Bearing Housing 1/2" Air Line FIG-5 O.) Align the primary bearing housing with the pedestal (as shown in Fig-5). 1/2" Push to Connect Fitting P.) Route the 1/2" airline down through the pedestal and out of the hole located on the side of the pedestal (See Fig-5). Q.) Slowly lower the arm onto the top of the pedestal, aligning the bolt holes. Secure the arms to the pedestal with 6 bolts from the accessory box. Torque bolts using the chart shown in Fig. 5. NOTE: It is recommended that LocTite threadlocker be used for this connection. Mounting Hardware (Included with shipment) R.) Align the secondary jib arm with the primary arm and attach with the mounting hardware included. NOTE: It is recommended that LocTite threadlocker be used for this connection. S.) Connect the 1/2" airline to the 1/2" push to connect fitting and secure the 1/2" NPT female fitting plate to the pedestal using the 1/4-20 SHCS provided. T.) System Power: Clean, dry air (90 PSI minimum). It is recommended that a filter regulator be placed between the incoming 1/2" NPT Female Fitting Secondary Jib Arm U.) Carefully rotate the jib crane to ensure clearance between jib arms and the surrounding areas. V.) If stud anchors are used at the Pedestal Base, cut-off excess thread above the nut so that 2-3 threads are exposed above the nut; 6 places. Do Not Over tighten Bolts: Over tightening will result in higher pull forces. SHCS Bolt Size Torque Ft.-Lbs. 1/2-13 110 5/8-11 210 3/4-10 380 Page 5 of 5