Wearable PZT sensors for distributed soft contact sensing (Design and Signal Conditioning Manual)

Similar documents
Active Vibration Control in Ultrasonic Wire Bonding Improving Bondability on Demanding Surfaces

Lamb Wave Ultrasonic Stylus

Design & Simulation of Multi Gate Piezoelectric FET Devices for Sensing Applications

HAPTIC A PROMISING NEW SOLUTION FOR AN ADVANCED HUMAN-MACHINE INTERFACE

CMP for More Than Moore

PL112 PL140 PICMA Bender

Challenges to Improving the Accuracy of High Frequency (120MHz) Test Systems

Flexible force sensors for e-textiles

Novel Approach to Make Low Cost, High Density PZT Phased Array and Its Application in Structural Health Monitoring

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

Abstract. 1 Introduction. 1.2 Concept. 1.1 Problematic. 1.3 Modelling

PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER

Electronic supplementary material

o Semiconductor Diode Symbol: The cathode contains the N-type material and the anode contains the P-type material.

Analysis of Electrical Noise in Piezoelectric Sensors

Application Note. Piezo Amplifier. Piezoelectric Amplifier Connection. accelinstruments.com

PvdF Piezoelectric Film Based Force Measuring System

Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements

Introduction to Microeletromechanical Systems (MEMS) Lecture 12 Topics. MEMS Overview

LABORATORY 5 v3 OPERATIONAL AMPLIFIER

STUDY OF VIBRATION MODAL ESTIMATION FOR COMPOSITE BEAM WITH PZT THIN FILM SENSOR SYSTEM

SGM8908 Capless 3Vrms Line Driver with Adjustable Gain

Driving Strain-Gauge Bridge Sensors with Signal- Conditioning ICs

Module 1: Overview of Vibration Control. Lecture 3: Active Vibration Control. The Lecture Contains: Different strategies for vibration control

Integration of Piezoceramic Modules into Die Castings Procedure and Functionalities

AN-1106 Custom Instrumentation Amplifier Design Author: Craig Cary Date: January 16, 2017

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Operational Amplifier BME 360 Lecture Notes Ying Sun

A New Lamb-Wave Based NDT System for Detection and Identification of Defects in Composites

A Review of MEMS Based Piezoelectric Energy Harvester for Low Frequency Applications

Measuring Myoelectric Potential Patterns Based on Two-Dimensional Signal Transmission Technology

Photops. Photodiode-Amplifier Hybrids

Keywords: piezoelectric, micro gyroscope, reference vibration, finite element

Significance of a low noise preamplifier and filter stage for under water imaging applications

Chapter 13: Comparators

EE 210 Lab Exercise #5: OP-AMPS I

OPERATIONAL AMPLIFIERS and FEEDBACK

MEMS Optical Scanner "ECO SCAN" Application Notes. Ver.0

INTRODUCTION: Basic operating principle of a MOSFET:

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers

Analog Circuits Part 3 Operational Amplifiers

Electronic Metronome. Using a 555 Timer

CIRCULAR PHASED ARRAY PROBES FOR INSPECTION OF SUPERPHOENIX STEAM GENERATOR TUBES

Zero-Bias Resonant Sensor with an Oxide-Nitride Layer as Charge Trap

RT A, Low Input Voltage, Ultra-Low Dropout LDO Regulator with Enable. Features. General Description. Applications. Ordering Information

Antennas and Propagation for Body-Centric Wireless Communications

EXAM Amplifiers and Instrumentation (EE1C31)

Homework Assignment 03

Concepts to be Reviewed

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

FLUTTER CONTROL OF WIND TUNNEL MODEL USING A SINGLE ELEMENT OF PIEZO-CERAMIC ACTUATOR

Tactile Interfaces: Technologies, Applications and Challenges

Piezoelectric Generator for Powering Remote Sensing Networks

Experiment 1: Amplifier Characterization Spring 2019

Switch-less Dual-frequency Reconfigurable CMOS Oscillator using One Single Piezoelectric AlN MEMS Resonator with Co-existing S0 and S1 Lamb-wave Modes

Modeling and Simulation of Powertrains for Electric and Hybrid Vehicles

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

Infrared Communications Lab

SMASIS PLANAR RF ANTENNA RECONFIGURATION WITH NI-TI SHAPE MEMORY ALLOYS

Cir cuit s 212 Lab. Lab #7 Filter Design. Introductions:

A BIOMIMETIC SENSING SKIN: CHARACTERIZATION OF PIEZORESISTIVE FABRIC-BASED ELASTOMERIC SENSORS

Introduction to LIVM Accelerometers

Journal of Advanced Mechanical Design, Systems, and Manufacturing

Lecture 14 Interface Electronics (Part 2) ECE 5900/6900 Fundamentals of Sensor Design

AS Benson Liu 2016/12/28 Ryan Liu 2016/12/28 Welson Tan 2016/12/28. 1 of 5. Product Name

Coupled inductors on silicon for PwrSoC in the frame of PowerSwipe project

Homework Assignment 07

Ultrasonic sensors in subsea oil & gas production current use and opportunities

ISSCC 2006 / SESSION 16 / MEMS AND SENSORS / 16.1

MEMS in ECE at CMU. Gary K. Fedder

Application Note: Precision Displacement Test Stand Rev A

Modal Analysis of Microcantilever using Vibration Speaker

Varactor Loaded Transmission Lines for Linear Applications

Chapter 9: Operational Amplifiers

New fabrication and packaging technologies for CMOS pixel sensors: closing gap between hybrid and monolithic

Advanced Measurements

IN-CHIP DEVICE-LAYER THERMAL ISOLATION OF MEMS RESONATOR FOR LOWER POWER BUDGET

PDu150CL Ultra low Noise 150V Piezo Driver with Strain Gauge Feedback

PACKAGING OF STRUCTURAL HEALTH MONITORING COMPONENTS

Introduction to Analog Interfacing. ECE/CS 5780/6780: Embedded System Design. Various Op Amps. Ideal Op Amps

Lab 2: Optical Theremin Team 2 Flyback By Brian Pugh, Andrew Baker, and Michael Betts

RF(Radio Frequency) MEMS (Micro Electro Mechanical

Characterization of Silicon-based Ultrasonic Nozzles

Chapter 3 THE DIFFERENTIATOR AND INTEGRATOR Name: Date

GSM BASED PATIENT MONITORING SYSTEM

Technical Information

CHARACTERIZATION OF OP-AMP

Lesson number one. Operational Amplifier Basics

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

SELECTION OF MATERIALS AND SENSORS FOR HEALTH MONITORING OF COMPOSITE STRUCTURES

A high temperature 100 mv/g triaxial accelerometer. Endevco technical paper 329

Aluminum Nitride Reconfigurable RF-MEMS Front-Ends

Magnetic and Electromagnetic Microsystems. 4. Example: magnetic read/write head

2007-Novel structures of a MEMS-based pressure sensor

AERO2705 Space Engineering 1 Week 7 The University of Sydney

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015

UNIT-VI FIELD EFFECT TRANSISTOR. 1. Explain about the Field Effect Transistor and also mention types of FET s.

LTS(3-terminal type self-oscillation formula) series TSP(2-terminal type separate excitation oscillation formula) series

E84 Lab 6: Design of a transimpedance photodiode amplifier

Lab 4. Crystal Oscillator

Transcription:

Wearable PZT sensors for distributed soft contact sensing (Design and Signal Conditioning Manual) Harshal Sonar, Prof. Jamie Paik Reconfigurable Robotics Lab, EPFL Contact: harshal.sonar@epfl.ch February, 23, 2016 Introduction For any soft wearable device the information about the surrounding environment and interactions is an important performance aspect. A sensor design becomes challenging when the target component has a non-uniform, agile, high resolution, and soft surface. Recent developments in wearable sensor technology have made it possible to embed piezoelectric element (PZT) based sensors, conductive fabrics, electro-active polymers and other families of stretchable and flexible sensors into soft silicone. We have developed PZT based sensors for wearable applications owing to their low cost, high sensitivity, high customization and low hysteresis properties. Multiple PZT sensors can be distributed over the actuation surface to provide multiple points for sensing. Piezoelectric ceramics are known to be highly sensitive to normal forces applied and can be embedded into silicone substrates [1]. Our sensors can have multiple pixels of PZT elements discretely distributed over a surface area in the form of grid. The PZT sensing elements are connected using flexible circuit tracks manufactured by laser cutting the copper-plated kapton (polyamide) material. The construction is then embedded inside silicone material for additional support and electrical insulation. The novelty in our design includes customizability, high density, parallel information gathering and the possibility of active feedback control using sensed information [2]. The presented prototype's mechanical and functional capacities are promising for applications in biomedical systems where soft, wearable and high precision sensors are needed these sensors and their applications are highly desired in human-robot interaction, biomedical robotics and biomimetic robotics in order to provide effective sensory feedback. The sensor applications can also be extended further wherever the similar performance is necessary. System Overview 1. Sensor Design : Sensor fabrication begins with selection of pixel-dimensions and density required for the specific application. We selected 2 x 2mm 2 size PZT element for the prototype sensor design [2]. This PZT element is then sandwiched between two copper-kapton electrodes for connections. Sensors can be of different sizes and can be oriented in the form of matrix over a distributed area. Figure 2 shows a 8x2 matrix distribution and a 3 sensor circular perimeter distribution of PZT sensors for two different applications. Also, the novel manufacturing procedure enables placement of two electrodes on top of each other which helps to reduce the area required for electronic tracks 1

and further improves the sensor density for distributed sensing. (E) Figure 1. Sensor manufacturing process of the PZT sensor prototype with 2 x 2mm 2 PZT elements with laser engraving(a), adhesive application(b), sensor placement(c), and sensor schematic (D). Silicone integrated 8x2 PZT sensor matrix demonstrating flexibility and distribution capabilities (E). 2. Electronics and Signal Conditioning: PZT material converts applied mechanical stress (σ) into proportional electrical charge (q). The Charge generated is very small and susceptible to external electrical loading. Therefore, a high input impedance charge amplifier is used to amplify the sensor signal and convert it into voltage proportional to the applied stress. The electrical equivalent circuit for PZT sensor is as shown in Figure 3A where charge(q=k σ) generated by mechanical stress across the piezo capacitor give rise to excitation voltage. This excitation voltage(v) is amplified and low pass filtered using the charge amplifier. For our sensor the sensitivity is around 0.25V/N [2]. The transfer function for piezo circuit can be easily deducted as: VVVV (s) σ(s) = kkk (1 + ττ) (1) Where, τ = RRRR. 2

Figure 2 : Electrical equivalent circuit of PZT sensor (A) and Charge amplifier using OpAmp (B) Also, the transfer function for charge amplifier is given as: VVVV (s) VVV(s) = RR R1(1 + RRRRR) + 1 = G (1 + τ2s) + 1 (2) Where, G= DC gain and τ2 = RRRR. Now, from equations (1) and (2) overall transfer function of PZT sensor can be written as: VVVV(S) σ(s) = KK (1 + ττ) G + 1 (3) (1 + τ2s) 3. Reading Data: As seen from Equation (3) the overall transfer function for PZT sensor with amplification stage acts as an active band-pass filter with tunable gain G and time constants τ and τ 2. For example, we practically obtained C p =1F, k=0.25 V/N, R p >>R bias =10MΩ. Now, with R 1 = 10k, R f =39k and C f = 47ηF, The overall transfer function performs like a band pass filter with lower cutoff frequency of 15 Hz, upper cutoff frequency of 86Hz and overall dc gain of 1.2. These values can be tuned depending upon the application requirement. However, it is important to note that once sensor is integrated inside soft silicone the transfer function is also modulated by the thickness of the silicone layer discussed in detail in [1]. 3

Figure 3: Printed Circuit Board Schematic for PZT sensor interfacing The charge amplifier circuit is implemented using TLV2774 [3], a high slew rate quad OpAmp IC, as shown in Figure 3. This circuit is driven using dual power supply ranging from 2.5V - 5.5V. A single PCB can simultaneously interface 4 PZT sensors as depicted in Figure 4. Where, Sense+/- is sensor input and Out+/- is corresponding amplifier output. Signal generated by PZT sensor is low pass filtered to remove high frequency noise. We recorded sample response for the PZT sensor in two cases as shown in Figure 4. Figure 4: PZT sensor response as recorded using charge amplifier circuit for finger tapping and removal (A) and continuous step input using SPA-skin [2] at 10 Hz (B) 4

References : [1] Acer, Merve, et al. "Development and characterization of silicone embedded distributed piezoelectric sensors for contact detection." Smart Materials and Structures 24.7 (2015) : 075030. [2] Sonar, Harshal Arun, and Jamie Paik. "Soft pneumatic actuator skin with piezoelectric sensors for vibrotactile feedback." Frontiers in Robotics and AI 2 (2015) : 38. [3] Datasheet TLV2774 Online: http://www.ti.com/lit/gpn/tlv2774 5