WAF S 12 W - N S DR Series Name Input Output Output Input Remote Control Load Share Assembly Voltage Quantity Voltage Range Option Option Option

Similar documents
WAF300_ EH-0817 PART NUMBER STRUCTURE 24:24 28:28 48:48

FED30-48 S 05 - N HC Series Name Input Output Output Remote Control Assembly Option Voltage Quantity Voltage Option PART NUMBER STRUCTURE

FED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly Option Voltage Quantity Voltage Range Option

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Full Load

QAE100W SERIES QUARTER-BRICK DC-DC CONVERTER

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

MI2000ERW. Series. Miniature 1 x 1 20W, Ultra-Wide 2:1 Input DC/DC Con vert ers. Key Features:


MXD40Multi_ EH-0218 PART NUMBER STRUCTURE. Vo3 (Triple only) 9: 24V. y: refer to Suffix yy. P-DUKE Technology Co., Ltd.

PXD10-Single Output DC/DC Converter

C B. Models. Models 2MOPP

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

Notes: Note1: Max. capacitive load is tested at nominal input voltage and full load. Single or Dual

ESB Series Embedded EMC Filter Up to 40W converter

PXD30-xxWS-xx-Single Output DC/DC Converters

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

9 to 36 Vdc and 18 to 75 Vdc input, 3.3 to 15 Vdc Single Output, 40W. Features

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Note1: Measured at nominal input voltage and full load Note2: Measured at minimum input voltage and constant resistive load

PM24S/DR24S series 60W Single Output DC/DC Converter

STB Series 2:1 & 4:1 Vin range / up to 60W 1/16 Brick

CV SERIES. 1.8 to 45 Watts VDC, VDC, 10-30VDC Input Ranges Adjustable Output Voltage Non-Isolated DC/DC Converters

VOF XX - XXX - X

MLSR100 Series. High Efficiency, 1.0A Surface Mount, POL Switching Regulators. Key Features:

PM24S/PM24D series 30W Single/Dual Output DC/DC Converter

Series AM50E-NZ 50 Watt DC-DC Converter

Ripple & Max. capacitive Output Current

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

Switching Regulator. LMT78_1.0R Series Wide input, non-isolated & regulated, single output, SMD package

Load (2) Single or Dual

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

MI2500RU. Series. Compact, 1 x 1 Inch 25W, 4:1 Input Range DC/DC Con vert ers. Key Features: Electrical Specifications

Load (2) Single or Dual

VMS-300A - XX - XXX - X

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Pinning (3) 4:1 Input Single or Dual. Notes: Note3: /X2 is without ON/OFF CTRL and without Output Voltage Trimming

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

RPP20-W. Features ICE Technology* POWERLINE+ 20 Watt 4:1 Single & Dual Output. DC/DC-Converter with 3 year Warranty

DN03S/D Series DC/DC CONVERTER 2-3W, DIP-Package

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

500 ma DC-DC Step Down Converter P78G-Series

High power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options

General. Environmental. EMC & Safety

DC/DC Converter VRA_YMD-6WR3 & VRB_YMD-6WR3 Series

Features. Regulated Converters. RS6 6 Watt. SIP8 Single and Dual Output. DC/DC Converter. Description. Selection Guide

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

15 W DC/DC CONVERTERS. SERIES DESCRIPTION Page. PC15WR 2:1 Input Range 2 2 x 1 Metal Can Package 2kv Isolation

For more information, please visit the product page. output. output current max (A)

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Features. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter

Efficiency (typ.) (Range) Load VDC VDC ma ma(typ.) ma(typ.) μf % MCWI05-12S

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

RPP30. Features ICE Technology* POWERLINE+ 30 Watt 2:1 Single & Dual Output. DC/DC-Converter with 3 year Warranty

DC/DC Converter URB_J(M)D/T-15W Series

MTC Series 15 W AC/DC Switching Power Supply Module Medical

25 Watt QMZ Single and Dual Series

CB Patent Protection RoHS

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

ISOLATED DC-DC CONVERTER EC4SBW SERIES APPLICATION NOTE

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

DC/DC Converter URA_ZP-6WR3 & URB_ZP-6WR3 Series

Electrical Specifications

LB115S 115W Single Output

DC/DC Converter URA_YMD-10WR3 & URB_YMD-10WR3 Series

DC/DC Converter K78xx-500R2 Series

FCW SERIES 15W WIDE INPUT RANGE

Note1: Max. capacitive load is tested at nominal input and constant resistive load. RI3- _/_ Isolation (2) Single

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

Electrical Specifications

DC/DC Converter K78_T-500R3 Series


Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Features. Switching Regulator. 0.5 Amp SIP3 Single Output R R DC/DC Converter

CB Patent Protection RoHS

Packaging. nom. Output Voltage

Series AMSRL1-78JZ Up to 12 Watt DC-DC Switching Regulator

For more information, please visit the product page. input voltage 1 range. output voltage

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

6S8W_3RP Series 6W - Dual/Single Output - Wide Input - Isolated & Regulated DC-DC Converter

(typ.) (Range) Parameter Model Min. Typ. Max. Unit

DC/DC Converter URB_YMD-15WR3 Series

S24SP series 60W Single Output DC/DC Converter

DC/DC Converter VRB_YMD-20WR3 Series

Transcription:

Railway Automation Datacom IPC Industry Measurement Telecom Charger Automobile Boat Medical PV PART NUMBER STRUCTURE WAF300-48 S 12 W - N S DR Series Name Input Output Output Input Remote Control Load Share Assembly Voltage Quantity Voltage Range Option Option Option () () 48:18~75 S:Single 12:12 4:1 :Positive logic, : None : Wall mounted 110:43~160 15:15 N:Negative logic S: Load Share DR: Din rail type 24:24 28:28 48:48 www.pduke.com 2018.08.03 Page 1

TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25 unless otherwise noted Model Number Input Range Output Voltage Output Current @Full Load Input Current @ No Load Efficiency A ma % WAF300-48S12W 18 ~ 75 12 25 30 89 WAF300-48S15W 18 ~ 75 15 20 30 90 WAF300-48S24W 18 ~ 75 24 12.5 30 92 WAF300-48S28W 18 ~ 75 28 10.8 30 91 WAF300-48S48W 18 ~ 75 48 6.3 30 92 WAF300-110S12W 43 ~ 160 12 25 20 89 WAF300-110S15W 43 ~ 160 15 20 20 90 WAF300-110S24W 43 ~ 160 24 12.5 20 91 WAF300-110S28W 43 ~ 160 28 10.8 20 91 WAF300-110S48W 43 ~ 160 48 6.3 20 92 INPUT SPECIFICATIONS Operating input voltage range 48Vin(nom) 18 48 75 43 110 160 Start up voltage 48Vin(nom) 18 43 Shutdown voltage 48Vin(nom) 15.6 16.2 16.8 33.0 34.5 36.0 Start up time Constant resistive load Power up Remote ON/OFF 140 ms Input surge voltage 1 second, max. 48Vin(nom) 100 185 Input filter Common choke + Pi type Remote ON/OFF Referred to Vin Positive logic (Standard) DC-DC ON DC-DC OFF Open or 3 ~ 12 Short or 0 ~ 1.2 Negative logic (Option) DC-DC ON DC-DC OFF Short or 0 ~ 1.2 Open or 3 ~ 12 Input current of Ctrl -0.5 1 ma Remote off input current 4.0 ma www.pduke.com 2018.08.03 Page 2

OUTPUT SPECIFICATIONS Rated Output Power Normal Vout and Iout 300 W Voltage accuracy -1 +1 % Line regulation Low Line to High Line at Full Load -0.2 +0.2 % Load regulation No Load to Full Load -0.5 +0.5 % Voltage adjustability Maximum output deviation is inclusive of remote sense -20 +20 % Remote sense % of Vout(nom) 10 % If remote sense is not being used, Sense terminals should be connected to corresponding polarity Vout terminals. Ripple and noise Measured by 20MHz bandwidth 12Vout, 15Vout 24Vout, 28Vout 48Vout Temperature coefficient -0.02 +0.02 %/ Transient response recovery time 25% load step change 250 μs Over voltage protection % of Vout(nom); Latch mode 125 140 % Over load protection % of Iout rated; C.C. mode * C.C. Mode is Constant Current Mode and test by nominal input. 105 115 % Short circuit protection C.C. mode, automatics recovery Load Share accuracy Full Load *Connect the LS (Terminal 11) from each converter. The converter can parallel to increase output current. It has internal load share function in this converter. (This function only for suffix -S part.) -10 +10 % 100 200 300 125 250 350 mvp-p GENERAL SPECIFICATIONS Isolation voltage 1 minute Input to Output 3000 Input (Output) to Case 1500 VAC Isolation resistance 500 1 GΩ Isolation capacitance 14000 pf Switching frequency 48 input 203 225 248 110 input 180 200 220 khz Safety approvals IEC/ UL/ EN60950-1 IEC /UL/ EN62368-1 UL508 UL:E193009 CB:UL(Demko) Standard approvals EN50155 EN45545-2 Case material Aluminum Potting material Silicone (UL94 V-0) Weight 900g (31.74oz.) MTBF MIL-HDBK-217F, Full load 1.490x 10 5 hrs ENVIRONMENTAL SPECIFICATIONS Operating case temperature -40 +100 Maximum case temperature +100 Over temperature protection +105 Storage temperature range -40 +105 Thermal impedance Mounted on the iron base-plate 1.1 /W * The iron base-plate dimension is 19 X 5.25 X 0.063 (The height is EIA standard 3U). Thermal shock MIL-STD-810F Shock EN61373, MIL-STD-810F Vibration EN61373, MIL-STD-810F Relative humidity 5% to 95% RH www.pduke.com 2018.08.03 Page 3

EMC SPECIFICATIONS Parameter Conditions Level EMI EN55011, EN55032 Without external component Radiation Class A Conduction ESD EN61000-4-2 Air ± 8kV and Contact ± 6kV Perf. Criteria A Radiated immunity EN61000-4-3 20V/m Perf. Criteria A Fast transient EN61000-4-4 ± 2kV Perf. Criteria A Surge EN61000-4-5 EN55024 ±1kV and EN50155 ±2kV Perf. Criteria A Conducted immunity EN61000-4-6 10Vr.m.s Perf. Criteria A Power frequency magnetic field EN61000-4-8 100A/m continuous; 1000A/m 1 second Perf. Criteria A CAUTION: This power module is not internally fused. An input line fuse must always be used. CHARACTERISTIC CURVE WAF300-48S W Derating Curve WAF300-48S W Derating Curve With 3U Iron Base-Plate WAF300-110S W Derating Curve WAF300-110S W Derating Curve With 3U Iron Base-Plate WAF300-48S12W Efficiency vs. Output Load WAF300-48S12W Efficiency vs. Input Voltage FUSE CONSIDERATION This power module is not internally fused. An input line fuse must always be used. This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of sophisticated power architecture. To maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The input line fuse suggest as below: Model Fuse Rating (A) Fuse Type WAF300-48S W 25 Fast-Acting WAF300-110S W 12 Fast-Acting The table based on the information provided in this data sheet on inrush energy and maximum DC input current at low Vin. www.pduke.com 2018.08.03 Page 4

MECHANICAL DRAWING WALL MOUNTED TYPE TERMINAL CONNECTION Terminal Define Recommend Matching Wire 1, 2 +Vin 12-16 AWG 3, 4 -Vin 12-16 AWG 5 Ctrl 12-28AWG 6, 7 + Vout 12-16 AWG 8, 9 - Vout 12-16 AWG 10 + Sense 20-28 AWG 11 LS (option) 20-28 AWG 12 - Sense 20-28 AWG * The current rating of the terminal block is 15 amps/pole. * Using 2 poles at the same time when operating is recommended if the total current are more than 15 amps or choose optional 2-way splitter. (Please refer to the diagram below) * Input voltage vs. Input terminal, refer to the table below. Output power Input voltage Input terminal 300W; Full load 23V 1 pole <23V 2 poles 400W; C.C. mode 32V 1 pole <32V 2 poles 1. All dimensions in inch [mm] 2. Tolerance : x.xx±0.02 [x.x±0.5] x.xxx±0.010 [x.xx±0.25] 3. The screw locked torque: MAX 14kgf-cm/1.37N.m DIN RAIL TYPE www.pduke.com 2018.08.03 Page 5

2-WAY SPLITTER (OPTIONAL ACCESSORY) The 2-way splitter can be used for transforming a thick wire into 2 thin wires to the terminal block. The 2-way splitter P/N:5J-C0045-F. 2-WAY SPLITTER Mechanical Drawing Connection Configuration THERMAL CONSIDERATIONS The power module operates in a variety of thermal environments. However, sufficient cooling should be provided to help ensure reliable operation of the unit. Heat is removed by conduction, convection, and radiation to the surrounding Environment. Proper cooling can be verified by measuring the point as the figure below. The temperature at this location should not exceed Maximum case temperature. When Operating, adequate cooling must be provided to maintain the test point temperature at or below Maximum case temperature. You can limit this Temperature to a lower value for extremely high reliability. Tel Fax Email Web Add +886-4-2359-0668 +886-4-2359-1337 sale@pduke.com www.pduke.com No. 36, 22 nd Rd., Taichung Industrial Park, Taichung, Taiwan, R.O.C. 2018.08.03 Page 6