INSTALLATION & OPERATION MANUAL

Similar documents
INSTALLATION & OPERATION MANUAL

SC-FI Series Frequency to Current Signal Conditioner

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

DRG-SC Series Signal Conditioners

Tel: (949) Fax: (949) IAA100 Product Manual

Installation, Operation and Maintenance Manual

FC-33, DC SELECTABLE SIGNAL CONDITIONER

MODEL AT-10 ANALOG TRANSMITTER

CAH CARD. user leaflet. 1 of 15. Copyright Issue 12.1 January 2015

WS12EX Position Sensor with Analog output Dust explosion-proof

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

WATT TRANSDUCER. Instruction Manual

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

OPERATION MANUAL LDM-1000

LAUREL ELECTRONICS, INC.

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ISOLATED 4-20 ma TRANSMITTERS

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc

Installation, Operation and Maintenance Manual

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

CURRENT/FREQUENCY CONVERTER S 104

Exercise 2: FM Detection With a PLL

This Datasheet is for the IC693ALG391. Analog Current Output - 2 Channel.

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

INSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter

PHYS Contemporary Physics Laboratory Laboratory Exercise: LAB 01 Resistivity, Root-mean-square Voltage, Potentiometer (updated 1/25/2017)

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

TMP-100 Turbine Meter Pulse Divider Circuit

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

AMX Series. Precision AC Test Power Single and Three Phase Linear AC Power Sources. Parallelable to 30 kva. T h e P o w e r o f E x p e r t i s e

GP-UF/A. Smith Meter Universal F/A Converter. Specifications. Features. Applications. Specifications

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

Installation and Operating Manual

WORLD S SMALLEST BARGRAPH METER LOOP OR AC/DC POWERED > 30 INPUT SIGNAL CONDITIONERS

AC Current Transducers

DC Current Transducers

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

EE 2274 DIODE OR GATE & CLIPPING CIRCUIT

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

User s Guide FLSC-45/45B. Paddlewheel Signal Conditioner. Shop online at omega.com

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

Variable Gm Calibration Procedure

The Harvard Research Carrier Signal Conditioner User s Manual

DP2000 ORDERING GUIDE To Order MODEL NO.

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

EXAMPLE. Use this jack for the red test lead when measuring. current from 0 to 200mA. Figure P-1

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

HAU Series Controllers

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

FIBER OPTIC DISPLACEMENT SENSORS. with Analog Output

Process Calibrator. TechChek 820

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

JTM-97a CALIBRATION PROCEDURE

CAV444 C/V transmitter IC with adjustable output voltage for capacitive input signals

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

LVC Low Voltage Conditioner. User Manual

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

Precision Frequency To Voltage Converter Card

500mA Laser Diode Controller

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

Detcon Model FP Transmitter Test Fixture Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1

ARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS

ELECTRICAL TRANSDUCER. CE-T Series

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

4-20 MA CURRENT LOOP SIMULATOR USING A PT100 RTD TEMPERATURE TRANSMITTER

D100L Series. 100 Hz to 100 khz Low Noise Fixed Frequency. 4- and 8- Pole Low-Pass Filters

PEOPLE IN CONTROL OF MOTION

Apitech Valve Drive Board

HC-220 PID Controller

Current Loop Interface Module M 2025D

500C Advanced Training Outline

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

SENSOTEC, INC Arlingate Lane Columbus, Ohio Phone (614) Facsimile (614) Toll Free Free (800)

TD-1 Tone Decoder / Trigger Version 1.0

LOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276

Signal Conditioner. Intelligent Frequency Converter. User Manual. SGN-UM EN-01 (November 2013)

Basic operational amplifier circuits In this lab exercise, we look at a variety of op-amp circuits. Note that this is a two-period lab.

EE EXPERIMENT 2 ANALOG AND DIGITAL MULTIMETERS INTRODUCTION. Figure 1: Internal resistance of a non-ideal ammeter.

User Manual Rev. 1811

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

University of North Carolina, Charlotte Department of Electrical and Computer Engineering ECGR 3157 EE Design II Fall 2009

BENNING. CM7 Electrical Tester. Service Information

Assembly Manual for VFO Board 2 August 2018

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

GSV-1H 010/250/2. Highlights

Transcription:

INSTALLATION & OPERATION MANUAL Analog Signal Conditioner Rev. C Page 0

GENERAL DESCRIPTION: The frequency to current/voltage converter is designed to be a general purpose signal conditioner. The signal conditioner may be used as a frequency to currency (F/I), or a frequency to voltage (F/V) converter. The signal conditioner has been factory calibrated to the customer request of conversion methods (F/I or F/V), and to the desired turbine flow meter. This manual may be used for either method of conversion, and is split into two sections, F/I and F/V. When the signal conditioner is used as a F/I converter, it is designed to linearly convert a frequency input signal into an equivalent4 20, or 10 50 ma current output signal. The signal conditioner is to be used with a turbine flow meter equipped with a magnetic pick-up. The frequency input to the signal conditioner is proportional to the rate of flow through the turbine flow meter. The signal conditioner will translate that input signal into a linear current output signal. Example. For a unit set on the 4 20 ma setting: a 4 ma output signal represents no flow, and a 20 ma output signal represents the maximum rated flow of the turbine flow meter. Data transmission in a current form exhibits excellent noise immunity and the capability for long distance transmission. When the signal conditioner is used as a F/V converter, it is designed to linearly convert a frequency input signal into an equivalent 0 5, or 0 20V voltage output signal. The signal conditioner is to be used with a turbine flow meter equipped with a magnetic pick-up. The frequency input to the signal conditioner is proportional to the rate of flow through the turbine flow meter. The signal conditioner will translate that input signal into linear voltage output signal. Example. For a unit set on the 10 Volt setting: a 0 V output signal represents no flow, and a 10 V output signal represents the maximum rated flow of the turbine flow meter. GENERAL SPECIFICATIONS: 1 Supply Voltage: Minimum 11.0 VDC Maximum 38.0 VDC Supply Current: Standard 4.3 ma Input Protection: Frequency Input Range: 2 High Range, max. full scale 12.8 KHz min. full scale 1300 Hz Low Range, max. full scale 1200 Hz min. full scale 115 Hz Input Sensitivity ±22 mv to ±50 V Output Protection: Short to +VDC or Common Continuos Output Setting Time, full scale change to 95% of final value 1.8 sec. Output Ripple and Noise 5 mv peak to peak <2 mv rms.,.05% of FS Linearity 0.2% of full scale Temperature Coefficient, 25 to 40 C 0.13%/C 13 mv/v on 10V range Operating Temperature, Standard -28 to 160 F special -40 to 250 F Zero / Span adjustment Interaction: <1% 1 Typical performance. Unless specified, measurements are made under the following conditions: 25 C, 12 VDC supply, 10 Volt output setting, High Frequency Range, calibrated at 2 KHz full scale. 2 Max. Full scale is defined a 1 turn from extreme end of potentiometer. Further range is available, but linearity is degraded to > 0.5%. Page 1

CURRENT MODE SPECIFICATINS: 3 Wire Output Version: 20 ma Range 50 ma Range minimum Output Current: 0.07 ma 0.19 ma Maximum Output Current, (Full Scale Min. Cal, Zero Cal set to 4 ma and 10 ma) 24.1 ma 61.2 ma Load resistance <(+V 6v)/full scale output =V=12V <300 ohms <120 ohms +V=24V <900 ohms <360 ohms BENCH CALIBRATION FOR CURRENT MODE Bench calibration is not necessary if the unit was factory assembled, or if the module was calibrated, at the factory, for the specific turbine meter. Bench calibration, however, is necessary for field replacement or up grade to an existing unit. Required Equipment: 12 Volt (DC) power supply, digital multi-meter, frequency generator, and a screw driver (.100 flat tip). Jumper Terminal 1 & 3 for current mode. Jumper Selection: three jumper settings need to be determined and set before bench calibration can commence. 1. Frequency Jumper: The frequency jumper is set according to the max. frequency the signal conditioner will encounter. This frequency is equal to the K factor of the meter times the maximum rated flow rate of the turbine meter, in gallons per minute (GPM). If this number is less than 13oo Hz the jumper is set to the low setting. If the number is greater that 1000 Hz, the jumper is set to the high setting (see FIGURE 2.). 2. Range Jumper: The range jumper is set according to the desired conversion method, as follows: (see FIGURE 2). 20 ma if the desired output signal is to be 4 20 ma 50 ma if the desired output signal is to be 10 50 ma 3. Mode Jumper: The mode jumper is set according to the desired conversion method, as follows: (see FIGURE 2). V for frequency to voltage conversion. C for frequency to current conversion. Bench Calibration Procedure: (see FIGURE 2). 1. Connect digital multi-meter positive lead to the power supply positive, and the negative multimeter lead to location #1 on the terminal strip on the signal conditioner. Set the function of the multi-meter to ma DC. 2. Connect the power supply negative lead to location #2 on the terminal strip on the signal conditioner. 3. Connect the frequency generator positive lead to location #4, and the negative lead to location #5 on the terminal strip on the signal conditioner. Adjust the signal amplitude of the frequency generator to 50mV, and the frequency to the maximum desired point (full scale frequency). 4. Adjust the frequency generator amplitude to zero (turn it off), adjust the zero pot, so that the Page 2

digital multi-meter reads 4.00 ma (using the 4 20 ma setting, or 10 ma using the 10 50 ma setting). 5. Turn the power supply, multi-meter, and the frequency generator on adjust the span pot. so that the digital multi-meter reads 20.00 ma (using the 4 2- ma setting, or 50 ma using the 10 50 ma setting). 6. Readjust the frequency generator to the desired maximum frequency, (turn it back on) adjust the span pot. so that the digital multi-meter reads 2.00 ma (using the 4 20 ma setting, 0r 50 ma using the 10-50 ma setting). 7.Repeat steps 4 through 6 until no adjustment to zero or span is required. 8. Record the maximum frequency and current on the data record (Figure 1). 9. Adjust the frequency of the frequency generator to exactly 50% of the maximum frequency, the digital multi-meter should read 12.00 ma ±.06 (30 ma on 10 50 ma setting). 10. Repeat step 9 for 25% and 75% and record data (Figure 1.). the multi-meter should read 8 ma and 16 ma respectively (20 ma and 40 ma on 10 50 ma setting). To check linearity at any point incorporate the following formula: ((F/F max.) Χ 16) = +4 ma for 4-20 ma setting ((F/F max.) Χ 40) = +10 ma for 10 50 ma setting Example: (4 20mA setting) Assume maximum frequency = 2000 Hz (20 ma point) Check for linearity at 750 Hz. ((750/2000) Χ 16) + ma = 10.00 ma. Therefore, the multi-meter should read 10.00 ma at 750Hz input frequency. Figure 1 Model No. Serial No. K Factor Current (4 20) Current (10 50) Frequency (Hz) G.P.M. L.P.M. 4 ma 10 ma 8 ma 20 ma 12 ma 30 ma 16 ma 40 ma 20 ma 50 ma Page 3

VOLTAGE MODE SPECIFICATIONS: 5 Volt Range 10 Volt Range VOUT min. (Freq. input + 0 Hz), at full scale max, freq. cal 5.1 mv 10.5 mv VOUT min. at full scale max. freq. cal 21 mv 43 mv VOUT max. at Vsupply = + 12 Vdc 6.8 V 11.3 V VOUT max. at Vsupply = + 24 Vdc 6.8 V 13.7 V Minimum Load resistance 50 ohm, 1/2W 100 ohm, 1W (OUTPUT CURRENT LIMIT = 100 Ma) Maximum Load resistance Open Open BENCH CALIBRATION FOR VOLTAGE MODE: Bench calibration is not necessary if the unit was factory assembled, or if the module was calibrated, at the factory, for the specific turbine meter. Bench calibration, however, is necessary for field replacement or up grade to an existing unit. Required Equipment: 12 Volt (DC) power supply, digital multi-meter, frequency generator, and screw driver (.100 flat tip). Jumper Selection: Three jumper settings need to be determined and set before bench calibration can commerce. 1. Frequency Jumper: The frequency jumper is set according to the max. frequency the signal conditioner will encounter. The frequency is equal to the K factor of the meter times the maximum rated flow rate of the turbine meter, in gallons per minute (GPM). If this number is less than 1300 Hz the jumper is set to the low setting. If the number is greater that 1300 Hz, the jumper is set to the high setting (see Figure 2). 2.Range Jumper: The range jumper is set according to the desired conversion rang, as follows: (see FIGURE 2). 5 Volt if the desired output signal is to be 0 5 Volt 10 Volt if the desired output signal is to be 0 10 Volt 3. Mode Jumper: The mode jumper is set according to the desired conversion method, as follows (see FIGURE 2). V for frequency to voltage conversion. C for frequency to current conversion. Bench Calibration Procedure: (see FIGURE 2). 1. Connect the digital multi-multi positive lead to terminal strip location #3, and the negative lead to location #2 on the terminal strip on the signal conditioner, and set the function on the multi-meter to DC Volts. 2. Connect power supply positive lead to terminal strip location #1, and the negative lead to terminal strip location #2 located on the signal conditioner. Page 4

3. Connect the frequency generator positive lead to terminal strip located # 4, and the negative lead to terminal strip location # 5. Set the output of the frequency generator to sine wave and the amplitude to zero. 4. Turn on the power supply, multi-meter, and the frequency generator, the digital multi-meter should read 0 Vdc. 5. Adjust the zero potentiometer so that the multi-meter reads.00 V. 6. Adjust the amplitude of the frequency generator to 20 mv and the frequency to the desired maximum point (full scale frequency). 7. Adjust the span potentiometer to 5.00 V, or 10.00 V digital multi-meter indication. 8. Repeat steps #5 7, until no zero or span adjustment are necessary. 9. Record the maximum frequency generator and voltage on the data record (Figure 4). 10. Adjust the frequency of the frequency generator to exactly 50% of the maximum frequency, the digital multi-meter should read 2.50 V (5.00 V on the 0 10 V setting). 11. Repeat step #10 for 25% & 75% and record data (Figure 4). The multi-meter should read 1.25 V & 3.75 V respectively (2.50 V & 7.50 V on the 0 10 V setting). To check linearity at any point incorporate the following formula: F/F max.) Χ full scale output + Volts Example: Assume maximum frequency + 2000 Hz and full scale output voltage = 10.00 V. Check linearity at 750 Hz. (750/2000) Χ 10 = 3.75 V. Therefore, the digital multi-meter should read 3.75 V at 750 Hz input frequency. Figure #4 Model No. Serial No. K Factor Voltage (0-5) Voltage (0-10) Frequency (Hz) G.P.M. L.P.M. 0.00 V 0.00 V 1.25 V 2.50 V 2.50 V 5.00 V 3.75 V 7.50 V 5.00 V 10.00 V Page 5

WIRING INSTRUCTIONS: CURRENT MODE FREQUENCY TO CURRENT (F/I) MODE 4-20mA OUT Terminal description for the magnetic pick-up signal conditioner. Terminal location 1 Loop in (+) 2. Loop in (-) 3 Out 4 Mag Pick-up Signal In (+) 5 Mag Pick-up Signal In (-) Note: A jumper wire has to be placed between terminals 1 & 3. *See diagram at the end of this manual for complete Frequency to Current mode wiring instructions. FREQUENCY TO CURRENT (F/I) MODE 10-50mA OUT Terminal description for the magnetic pick-up signal conditioner. Terminal location 1. Loop in (+) 2. Loop in (-) 3. Out 4. Mag Pick-up Signal In (+) 5. Mag Pick-up Signal In (-) Note: A jumper wire has to be placed between terminals 1 & 3. *See diagram at end of this manual for complete Frequency to Current mode wiring instructions. Page 6

WIRING INSTRUCTIONS VOLTAGE MODE FREQUENCY TO VOLTAGE (F/V) MODE 0-5V OUT Terminal description for the magnetic pick-up signal conditioner. Terminal location 1. DC POWER (+) 2. GROUND 3. Signal out (+V) 4. Mag Pick-up Signal In (+) 5. Mag Pick-up Signal In (-) *See diagram at end of this manual for complete Frequency to voltage mode wiring instructions. FREQUENCY TO VOLTAGE (F/V) MODE 0-10V OUT Terminal description for the magnetic pick-up signal conditioner. Terminal location 1. DC POWER (+) 2. GROUND 3. Signal out (+V) 4. Mag Pick-up Signal In (+) 5. Mag Pick-up Signal In (-) *See diagram at end of this manual for complete Frequency to Voltage mode wiring instructions. Page 7

Page 8