T E S T - R E P O R T. No for. FHS 20/21 Typ 2 ASK 315 MHz. Remote Control Transmitter

Similar documents
T E S T - R E P O R T. Test Report No (Edition 1) for RF340-R. Inductive Tag Reader

T E S T - R E P O R T. Test Report No (Edition 1) for RF380R. Tag Reader

FCC CERTIFICATION TEST REPORT

TRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503

FCC PART TEST REPORT. Weccan Industrial Limited

TRANSMITTER MODEL: KAS-2030M

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

EMI T E S T R E P O R T

RF test report AU01+W02

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

Version TEST REPORT NO. DATE DESCRIPTION

121 FCCTR_ TEST REPORT MAGNETI MARELLI S.P.A.

FCC Report for Parts ,

Description of Test Facility

EMI -- T E S T R E P O R T

TEST REPORT SZEM CR

Test Report. ASSA ABLOY Hospitality AS Anolitveien 1-3, 1400 Ski, Norway. ASSA ABLOY Hospitality AS Anolitveien 1-3, 1400 Ski, Norway

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

EMC Test Report. Tested by: Jeremy O. Pickens, Senior EMC Engineer. Reviewed by: David Schramm, EMC/RF/SAR/HAC Manager

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

STC Test Report. Date : Page 1 of 13 No. : HM161169

EMI -- T E S T R E P O R T

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

F2 Labs Peters Road Middlefield, Ohio United States of America

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

CENTRE OF TESTING SERVICE INTERNATIONAL

Test Report. FCC Part 15, Subpart C, Section Industry Canada RSS-210, Issue 7

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

EMI T E S T R E P O R T

FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

FCC AND IC CERTIFICATION TEST REPORT

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

UL Japan, Inc. Head Office EMC Lab Asama-cho, Ise-shi, Mie-ken JAPAN Telephone : Facsimile :

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Test. Report. Manufacturer. Model No. FCC ID. Technology. and. 1. This. 3. This. pp John Newell. as UL. Date of Issue: 28 May 2013.

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

RF test report AU02+W01

G0M TFC95IMR2-V01. Eurofins Product Service GmbH Reichenwalde Germany

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

SILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With

EMI T E S T R E P O R T

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

Registered office Linköping

EUROFINS PRODUCT SERVICE GMBH. FCC RULES PARTS IC RADIO STANDARDS RSS-210 Issue 7 FCC ID: UOU68981AA630D-01 IC: 1884E

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

Test Report. Bluetooth Transceiver in UPCS Base Station. Panasonic Corporation of North America

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

Test report no. : Item tested : LCU Type of equipment : RFID Transceiver Module FCC ID : Y7V-LCU6333

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

Registered office Linköping

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

A Test Lab Techno Corp. Report Number:1410FR27

FCC PART & IC RSS GHz FHSS TEST REPORT

Pass* * In the configuration tested, the EUT complied with the standards specified above.

9. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY

RF test report AU01+Z04

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Test Report. Report Number: F113050E1. Applicant: deister electronic GmbH. Manufacturer: deister electronic GmbH. Equipment under Test (EUT):

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

FCC Rules and Regulations / Intentional Radiators. Operational in the MHz, MHz, MHz, and

TEST REPORT FROM RFI GLOBAL SERVICES LTD

EMI -- T E S T R E P O R T

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

Test Report Version. Test Report No. Date Description. DRTFCC Sep. 12, 2014 Initial issue

Compliance Engineering Ireland Ltd

Certification Test Report

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

FCC Part 22H & 24E Measurement and Test Report

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

TEST REPORT. Report No.: HK (R1) Spin Master Toys Far East Ltd. Application For Certification (Original Grant) (FCC ID: PQN44438TX2G4)

TEST REPORT. Issued for: ShenZhen MYGT Co.,LTD D3 Tongfuyu Industrial Area Community of Shajing Town, Baoan, Shenzhen, China.

TRANSMITTER Model: TX24

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Application for Grant of Equipment Authorization of the SMK Electronics Corp. RC04 RF Remote Control

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. RF ID Reader MODEL NUMBER: A-405 FCC ID: WFQITCS-A-405 IC: 10717A-ITCSA405

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

TEST REPORT N B Page 2

Test report no. : Item tested : DoseAware Base station

Certification Test Report

Test Report. Prepared for: Technologic Systems, Inc. Model: TS Description: Embedded Computer Board. Serial Number: N/A. FCC Part 15B Class A

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

Jul. 16, Jun. 04, Shenzhen. Tel:(86-755)

FCC Radio Test Report. Orpak Systems Ltd.

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

CETECOM ICT Services GmbH

Glen Westwell, Wireless Technologist

HID GLOBAL CORPORATION

FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: -

Transcription:

EMV-Prüfzentrum EMI/EMC-Testcenter Straubing, 8 May 3 T E S T - R E P O R T No. 553-3221 for Remote Control Transmitter Test Specification: FCC Code of Federal Regulations, Part 15 Subpart C, Section 15.231 Note: The test data of this report relate only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. FCC-ID: Test Report No. 553-3221 Page 1 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Table of Contents 1. Administrative Data...3 2. Identification of Test Laboratory...4 3. Operation Mode of EUT...5 4. Configuration...6 5. Measuring Methods...7 5.1. Field Strength of Emissions, Prescans in a fully-anechoic Room...7 5.2. Radiated Emission Measurement at Open Area Test Site...9 6. Photographs Taken During Testing... 7. List of Measurements...13 8. Referenced Regulations...18 Charts taken during testing...19 FCC-ID: Test Report No. 553-3221 Page 2 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 1. Administrative Data Test item (EUT) Type designation Serial number(s): 1 Type of equipment: Remote Control Transmitter Parts/accessories: FCC-ID: Technical data Frequency range Operational frequency Type of modulation Pulse frequency Pulse width Antenna Power supply (full address) N/A 315 MHz KA1D N/A N/A Integrated 3 V Lithium Battery ELDAT GmbH Gesellschaft für Elektronik und Daten Im Gewerbepark 14 15711 Zeesen Contract identification: --- Contact person: Manufacturer: Andreas Eidam Application details Receipt of EUT: 8 April 3 Date of test: April 3 Note: Responsible for testing: Responsible for test report: Martin Steindl Martin Steindl FCC-ID: Test Report No. 553-3221 Page 3 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 2. Identification of Test Laboratory DETAILS OF THE TEST LABORATORY COMPANY NAME: Senton GmbH EMI/EMC Test Center ADDRESS: Aeussere Fruehlingsstrasse 45 D-94315 Straubing Germany LABORATORY ACCREDITATION: DAR-Registration No. TTI-P-G 62/94-1 FCC TEST SITE LISTING INDUSTRY CANADA TEST SITE REGISTRATION NAME FOR CONTACT PURPOSES: IC 35 Mr. Johann Roidt TELEPHONE: (+49) ()9421 5522- FAX: (+49) ()9421 5522-99 PERSONNEL INVOLVED IN THIS TEST REPORT LABORATORY MANAGER: Mr. Johann Roidt RESPONSIBLE FOR TESTING: RESPONSIBLE FOR TEST REPORT: Mr. Martin Steindl Mr. Martin Steindl SUMMARY OF TEST RESULTS The tested sample complies with the requirements set forth in the FCC Code of Federal Regulations Part 15, Subpart C, Section 15.231 FCC-ID: Test Report No. 553-3221 Page 4 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 3. Operation Mode of EUT While one button is pressed, the transmitter continuously sends the corresponding datagram. When the button is released, the transmitter stops working instantly. FCC-ID: Test Report No. 553-3221 Page 5 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 4. Configuration Configuration of the EUT Not applicable Cables connected to the EUT Not applicable Peripheral devices connected to the EUT Not applicable FCC-ID: Test Report No. 553-3221 Page 6 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 5. Measuring Methods 5.1. Field Strength of Emissions, Prescans in a fully-anechoic room (3 MHz 1 GHz) Rules and Specifications: Sections 15.9 & 15.231 Guide: ANSI C63.4 1997 Measurement Procedure: Radiated emissions are measured over the frequency range from 3 MHz to 1 GHz. Measurements were made in both the horizontal and vertical planes of polarization in a fully anechoic room using a spectrum analyzer with the detector function set to peak and resolution bandwidth set to khz. All tests were performed at a test-distance of 3 meters. Hand-held or body-worn devices are rotated through three orthogonal axes to determine which attitude and configuration produces the highest emission relative to the limit and therefore shall be used for final testing. Spectrum Analyzer EUT 3 m test distance Test instruments used: Fully anechoic chamber No. Type Model Serial Number Manufacturer 1 Spectrum Analyzer FSP 3 63 Rohde & Schwarz 113 Preamplifier CPA9231A 3393 Schaffner 141 Biconical antenna HK 116 82978/6 Rohde & Schwarz 143 Log. periodic antenna 3147 9112-54 EMCO 3 Fully anechoic room No. 2 1452 Albatross Projects FCC-ID: Test Report No. 553-3221 Page 7 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 5.2. Fieldstrength of Emissions, Measurement at Open Area Test Site (3 MHz 1 GHz) Rules and Specifications: Sections 15.9 & 15.231 Guide: ANSI C63.4 1997 Measurement Procedure: Measurement Procedure: For final testing an open-area test-side was used. Radiated emissions are measured over the frequency range from 3 MHz to 1 GHz. Measurements were made in both the horizontal and vertical planes of polarisation at a open area test side using a spectrum analyser with the detector function set to CISPR. All test were performed at a test distance of 3 meters. During the tests the EUT is rotated all around, and the receivingantenna is rased and lowered from 1m to 4m to find the maximum levels of emissions. The cables and equipment were placed and moved within the range of position likely to find their maximum emissions. EUT 3 m test distance Spectrum Analyzer Test instruments used: No. Type Model Serial Number Manufacturer 1 EMI Receiver ESVP 881414/9 Rohde & Schwarz 141 Biconical antenna HK 116 82978/6 Rohde & Schwarz 143 Log. periodic antenna 3147 9112-54 EMCO 3 Open Field Test Site No. 1 N/A Senton FCC-ID: Test Report No. 553-3221 Page 8 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 5.3. Fieldstrength of Emissions above 1 GHz Rules and Specifications: Sections 15.9 & 15.9 Guide: ANSI C63.4 1997 Measurement Procedure: Radiated emissions are measured in the frequency range 1 GHz to the th harmoic of the maximum frequency of the EUT. Resolution and video bandwidth of the spectrum analyzer are set to 1 MHz. Hand-held or body-worn devices are rotated through three orthogonal axes to determine which attitude and configuration produces the highest emission relative to the limit and therefore shall be used for final testing. Additional measurements are performed at critical frequencies with reduced span. EUT is rotated all around and receiving antenna is raised and lowered to find the maximum levels of emission. The cables and equipment are placed and moved within the range of position likely to find their maximum emissions. All tests are performed in a fully-anechoic chamber with a test-distance of 3 meters. If required preamplifiers are used for the whole frequency range. Special care is taken to avoid overload in transmit mode (using appropriate attenuators and filters if necessary). Spectrum Analyzer EUT 3 m test distance Test instruments used: Fully anechoic No. Type Model Serial Number Manufacturer 1 Spectrum Analyzer FSP 3 63 Rohde & Schwarz 143 Log. periodic antenna 3147 9112-54 EMCO 145 Horn antenna 3115 958-4553 EMCO 146 Horn antenna set 316-3/-9 9112-3 EMCO 114 Preamplifier 1-8 GHz AFS3-8- 847743 Miteq 32-LN 115 Preamplifier 8-18 GHz ACO/18-353 32641 CTT FCC-ID: Test Report No. 553-3221 Page 9 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 6. Photographs Taken During Testing FCC-ID: Test Report No. 553-3221 Page of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Test setup for radiated emission measurement (fully anechoic room) FCC-ID: Test Report No. 553-3221 Page 11 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Test setup for radiated emission measurement (open-area test-side) FCC-ID: Test Report No. 553-3221 Page 12 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 7. List of Measurements FCC Part 15 Section(s): Test Page(s) Result 15.5 Restricted Bands --- Pass 15.231 (a) (1) Periodic operation --- Pass 15.231 (b) 15.231 (b) 15.231 (c) Duty cycle correction Field strength of emissions Bandwidth of emissions 14-15 16 Pass 17 Pass FCC-ID: Test Report No. 553-3221 Page 13 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Duty Cycle Correction Rules and Specifications: Guide: ANSI C63.4 ANSI C63.4 4.2 15.231 (b) (2) Limits on the Field Strength of Emissions When average detector function limits are specified for a pulse modulated transmitter, the average level of emissions may be found by measuring the peak levels of the emissions and correcting them with the duty cycle according to ANSI C64.4, section I4 () 13,7ms + 8 1.4ms DutyCycleCorrection 85 ms [ db] = log = 13. db Ref 27 dbmv Att db RBW 1 MHz VBW 3 MHz SWT ms Marker 1 [T1 ] -27.76 dbmv 85.84 ms Delta 1 [T1 ] -1.49 db -62.3 ms A 1 PK * VIEW TRG TRG -3.4 dbmv - - PRN 1 1-3 -4-5 -6-7 Center 315 MHz ms/ Comment A: ELD3237 - Duty Cycle Date: 9.MAY.3 14:16: FCC-ID: Test Report No. 553-3221 Page 14 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Ref 27 dbmv Att db 1 RBW 1 MHz VBW 3 MHz SWT ms 1 Delta 1 [T1 ] -.6 db 1.46 ms Marker 1 [T1 ] 15.86 dbmv 4.4 ms * A 1 PK * CLRWR TRG TRG -3.4 dbmv - - PRN -3-4 -5-6 -7 Center 315 MHz 1 ms/ Comment A: ELD3237 - Duty Cycle Date: 9.MAY.3 14:19:3 Ref 27 dbmv Att db RBW 1 MHz VBW 3 MHz SWT ms Marker 1 [T1 ] 15.89 dbmv 8. ms Delta 1 [T1 ] -.9 db 1 1 7. µs * A 1 PK * CLRWR TRG TRG -3.4 dbmv - - PRN -3-4 -5-6 -7 Center 315 MHz 1 ms/ Comment A: ELD3237 - Duty Cycle Date: 9.MAY.3 14:19:4 FCC-ID: Test Report No. 553-3221 Page 15 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Field strength of emissions Rules and Specifications: Guide: ANSI C63.4 Limit: 15.231 Radiated Emission Limits In addition to the provisions of Section 15.5, the field strength of emissions from intentional radiators operated under Section 15.231 shall not exceed the following: Frequency of Emission (MHz) 4.66 4.7 7 13 13-174 174-26 26 47 above 47 Field Strength (microvolts/meter) 225 125 125 to 375 ** 375 375 to 125 ** 125 ** linear interpolation Test Site: Distance: Open Area Test Site (< 1 GHz), Fully anechoic chamber (> 1 GHz) 3 Meter Frequency (MHz) Detector Antenna Polarization Analyzer Reading (dbµv) Antenna Correction (db/m) Duty Cycle Correction (db) Field Strength (dbµv/m) Limit (dbµv/m) Margin (db) 315. PK Hor 64.2 15.8-13.85 66.15 75.62-9.5 63. PK Ver 25.9 23. -13.85 35.25 55.62 -.4 26. PK Ver 14.61 31.45-13.85 32.21 55.62-23.4 2524. PK Ver 15.39 32.25-13.85 33.79 55.62-21.8 2836. PK Hor 11.95 33.61-13.85 31.71 55.62-23.9 *** = All emissions showed more than db margin to the limit A negative value for Margin indicates, that the limit is kept. Sample calculation of erp values: Field Strength (dbµv/m) = Analyzer Reading (dbµv) + Antenna Correction (db/m) + Duty Cycle Correction (db) Test Results: Pass FCC-ID: Test Report No. 553-3221 Page 16 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Bandwidth of Emission Rules and Specifications: 15.231 ( c ) Bandwidth of Emissions Guide: ANSI C63.4 Limit: The bandwidth of the emission shall be no wider than.25% of the center frequency for devices operating above 7 MHz and below 9 MHz. For devices operating above 9 MHz, the emission shall be no wider than.5% of the center frequency. Bandwidth is determined at the points db from the modulated carrier Ref - dbm Att db * RBW 3 Hz * VBW khz SWT 1.15 s Marker 1 [T1 ] -36.99 dbm 315.5 MHz 1 PK VIEW - -3-4 1 Marker 2 [T1 ] -56.99 dbm 315.38 MHz Marker 3 [T1 ] -59.13 dbm 315.8 MHz A -5 2 3-6 PRN -7-8 -9 - -1-1 Center 315.48 MHz khz/ Span khz Comment A: ELD3237 - Bandwidth of emission Date: 9.MAY.3 15:11:32 Bandwidth of emission at db points is 4.2 khz. Limit is 787.5 khz Test Results: Pass FCC-ID: Test Report No. 553-3221 Page 17 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter 8. Referenced Regulations All tests were performed with reference to the following regulations and standards: FCC Part 2 Code of Federal Regulations Part 2 Frequency allocationand radio treaty matters; General rules and regulations FCC Part 15 Subpart A FCC Part 15 Subpart B FCC Part 15 Subpart C FCC Part 74 Subpart H ANSI C63.4 Code of Regulations Part 15 (Radio Frequency Devices), Subpart A (General) of the Federal Communication Commission (FCC) Code of Regulations Part 15 (Radio Frequency Devices), Subpart B (Unintentional Radiators) of the Federal Communication Commission (FCC) Code of Regulations Part 15 (Radio Frequency Devices), Subpart C (Intentional Radiators) of the Federal Communication Commission (FCC) Code of Regulations Part 15 (Radio Frequency Devices), Subpart H (Low Power Auxiliary Stations) of the Federal Communication Commission (FCC) American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz - 4 GHz RSS-2 Radio Standards Specification RSS-2 Issue 2 for Low Power Licence-Exempt Radiocommuniction Devices of Industry Canada October 1, 1999 May 3, 2 May 3, 2 May 3, 2 October, 1997 October, 1992 February 24, 1996 FCC-ID: Test Report No. 553-3221 Page 18 of 19 Pages

EMV-Prüfzentrum EMI/EMC-Testcenter Charts taken during testing FCC-ID: Test Report No. 553-3221 Page 19 of 19 Pages

Restricted bands requirement acc. FCC 15 Part C Model: FHS /21 Typ2 ASK 315 MHz Serial No.: test sample Mode: - DC 3 V lithium battery supply - - sending pulsed Ref.Level 115.4 dbµv/m ATT db Ref. Offset 18.4 db db/div. 1 2 3 Start 314. MHz Stop 336. MHz RBW 219 khz VBW 3 khz SWP ms Multi Marker List No. 1 315.2222 MHz 82.14 dbµv/m No. 2 322. MHz 54.43 dbµv/m No. 3 335.4 MHz 56.11 dbµv/m Tested by: M. Steindl Date: 4/25/3 Project-No.: 553-3221 Page of pages Senton GmbH / EMI/EMC Test Center / Aeussere Fruehlingstrasse 45 / 94315 Straubing / Tel. +49 9421 552

Radiated Emission Test 3 MHz - MHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating z-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: HK 116 (A-156) 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 3 MHz - MHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating y-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: HK 116 (A-156) 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test MHz - 1 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating y-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3147 (A-9) 7 65 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test MHz - 1 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating y-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3147 (A-9) 85 8 7 6 5 4 3 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 1 GHz - 4 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating y-axis) - sending pulsed - with WHKS-SS high pass filter Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3115 8 75 7 65 6 55 5 45 4 35 3 25 15 5 3 4 MHz Result: Limit kept Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 1 GHz - 4 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating y-axis) - sending pulsed - with WHKS-SS high pass filter Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3115 8 75 7 65 6 55 5 45 4 35 3 25 15 5 3 4 MHz Result: Limit kept Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 3 MHz - MHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating y-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: HK 116 (A-156) 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 3 MHz - MHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating z-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: HK 116 (A-156) 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test MHz - 1 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating z-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3147 (A-9) 85 8 7 6 5 4 3 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test MHz - 1 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating z-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3147 (A-9) 7 65 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 1 GHz - 4 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating z-axis) - sending pulsed - with WHKS-SS high pass filter Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3115 8 75 7 65 6 55 5 45 4 35 3 25 15 5 3 4 MHz Result: Limit kept Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 1 GHz - 4 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating z-axis) - sending pulsed - with WHKS-SS high pass filter Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3115 8 75 7 65 6 55 5 45 4 35 3 25 15 5 3 4 MHz Result: Limit kept Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 3 MHz - MHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating x-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: HK 116 (A-156) 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 3 MHz - MHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating x-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: HK 116 (A-156) 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test MHz - 1 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating x-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3147 (A-9) 7 65 6 55 5 45 4 35 3 25 15 5 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test MHz - 1 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating x-axis) - sending pulsed Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: Selected by hand dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3147 (A-9) 85 8 7 6 5 4 3 3 4 5 6 7 8 9 MHz Result: Prescan Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 1 GHz - 4 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Horizontal Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating x-axis) - sending pulsed - with WHKS-SS high pass filter Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3115 8 75 7 65 6 55 5 45 4 35 3 25 15 5 3 4 MHz Result: Limit kept Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99

Radiated Emission Test 1 GHz - 4 GHz acc. to FCC Part 15 (Fully Anechoic Chamber) Model: Serial no.: test sample 1 Test site: Fully anechoic room, cabin no. 2 Tested on: Test distance 3 metres Vertical Polarization Comment: - DC 3 V lithium battery supply - EUT mouted in test fixture (rotating x-axis) - sending pulsed - with WHKS-SS high pass filter Date of test: 4/24/3 Test performed: automatically Operator: M. Steindl File name: default.emi Detector: Peak List of values: db Margin 5 Subranges dbµv/m Limit1: FCC Part 15 Transducer: EMCO 3115 8 75 7 65 6 55 5 45 4 35 3 25 15 5 3 4 MHz Result: Limit kept Project file: 553-3221 Page of Pages Senton GmbH / Aeussere Fruehlingstrasse 45 / D-94315 Straubing / Germany / Tel. +49 ()9421 5522- / Fax +49 ()9421 5522-99