Reference No.: WTS14S0513592E Page 2 of 44 1 Test Summary EMISSION Test Item Mains Terminal Disturbance Voltage, 150kHz to 30MHz Telecommunication ports interference voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz Test Standard Class / Severity Result EN 62040-2: 2006 Clause 6.4. Pass EN 62040-2: 2006 Clause 6.4. N/A EN 62040-2: 2006 Clause 6.5 Pass Harmonic Current EN 61000-3-2: 2006+A1: 2009+A2: 2009 Class A Pass Voltage Fluctuation and Flicker EN 61000-3-3:2013 Clause 5 Pass IMMUNITY (EN 62040-2: 2006) Test Item Test Method Class / Severity Electrostatic Discharge(ESD) EN 61000-4-2:2009 Radiation Immunity (80MHz to 1GHz) EN 61000-4-3:2006+ A1:2008 +A2:2010 4 kv Contact 8 kv Air 10V/m, 80%, 1kHz, Amp. Mod. Performance Criteria B A Result Pass Pass Electrical Fast Transients (EFT) AC input and output power ports EN 61000-4-4:2012 1kV/5 khz B Pass Electrical Fast Transients (EFT) DC power port, Signal and control ports EN 61000-4-4:2012 1kV/5 khz Capacitive clamp B N/A Surge for AC input and output power ports EN 61000-4-5:2006 1kV D.M. 2kV C.M. B Pass Surge for Signal and control ports Injected Currents, 0.15MHz to 80MHz EN 61000-4-5:2006 1kV B N/A EN 61000-4-6:2009 3Vr.m.s.(emf), 80%, 1kHz Amp. Mod. A Pass Remark: Pass Test item meets the requirement Fail Test item does not meet the requirement N/A Test case does not apply to the test object A.M Amplitude Modulation Differential Mode Common Mode * U T is the nominal supply voltage
Reference No.: WTS14S0513592E Page 3 of 44 2 Contents Page COVER PAGE 1 1 TEST SUMMARY... 2 2 CONTENTS... 3 3 GENERAL INFORMATION... 4 3.1 GENERAL DESCRIPTION OF E.U.T.... 4 3.2 DETAILS OF E.U.T.... 4 3.3 STANDARDS APPLICABLE FOR TESTING... 4 3.4 TEST FACILITY... 5 3.5 SUBCONTRACTED... 5 3.6 ABNORMALITIES FROM STANDARD CONDITIONS... 5 4 EQUIPMENT USED DURING TEST... 6 4.1 EQUIPMENT LIST... 6 4.2 MEASUREMENT UNCERTAINTY... 8 5 EMISSION TEST RESULTS... 9 5.1 MAINS INPUT TERMINALS DISTURBANCE VOLTAGE, 150KHZ TO 30MHZ... 9 5.2 RADIATION EMISSION, 30MHZ TO 1000MHZ... 12 5.3 HARMONICS CURRENT... 15 5.4 VOLTAGE FLUCTUATION AND FLICKER... 22 6 IMMUNITY TEST RESULTS... 24 6.1 PERFORMANCE CRITERIA... 24 6.2 ELECTROSTATIC DISCHARGE (ESD)... 25 6.3 RADIO-FREQUENCY ELECTROMAGNETIC FIELDS, 80MHZ TO 1GHZ... 27 6.4 ELECTRICAL FAST TRANSIENTS (EFT)... 29 6.5 SURGE... 31 6.6 INJECTED CURRENTS IMMUNITY, 0.15MHZ TO 80MHZ... 33 7 PHOTOGRAPHS TEST SETUP... 35 7.1 PHOTOGRAPH MAINS INPUT TERMINAL DISTURBANCE VOLTAGE TEST SETUP... 35 7.2 PHOTOGRAPH RADIATION EMISSION TEST SETUP... 35 7.3 PHOTOGRAPH HARMONIC CURRENT AND FLICKER TEST SETUP... 36 7.4 PHOTOGRAPH ESD IMMUNITY TEST SETUP... 36 7.5 PHOTOGRAPH RADIO-FREQUENCY ELECTROMAGNETIC FIELDS TEST SETUP... 37 7.6 PHOTOGRAPH EFT & SURGE IMMUNITY TEST SETUP... 37 7.7 PHOTOGRAPH INJECTED CURRENTS IMMUNITY TEST SETUP... 38 8 PHOTOGRAPHS CONSTRUCTIONAL DETAILS... 39 8.1 EUT APPEARANCE VIEW... 39 8.2 EUT OPEN VIEW... 40
Reference No.: WTS14S0513592E Page 5 of 44 3.4 Test Facility The test facility has a test site registered with the following organizations: IC Registration No.: 7760A-1 has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration 7760A-1, July 12, 2012. FCC Registration No.: 880581 has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 880581, May 26, 2011. 3.5 Subcontracted Whether parts of tests for the product have been subcontracted to other labs: Yes No If Yes, list the related test items and lab information: Test Lab: Lab address: Test items: N/A N/A N/A 3.6 Abnormalities from Standard Conditions None.
Reference No.: WTS14S0513592E Page 6 of 44 4 Equipment Used during Test 4.1 Equipment List Equipment Name EMC Analyzer Trilog Broadban d Antenne 30-3000 MHz Broad-ban d Horn Antenna 1-18 GHz Broadban d Preamplifi er 0.5-18 GHz 10m Coaxial Cable with N-male Connector s usable up to 18GHz, 10m 50 Ohm Coaxial Cable with N-plug,indi vidual length,usa ble up to 3(5)GHz, Connector Positionin g Controller Color Monitor Test Receiver Manufacturer Model Agilent/ E7405A SCHWARZB ECK MESS-ELEK TROM/ VULB9163 SCHWARZB ECK MESS-ELEK TROM/ VULB9163 SCHWARZB ECK MESS-ELEK TROM/ BBV 9718 SCHWARZB ECK MESS-ELEK TROM/ AK 9515 H Equipm ent No MY4511 4943 336 667 9718-14 8 - Interna l No W2008 001 W2008 002 W2008 003 W2008 004 - - Specification 9k-26.5GHz 30-3000 MHz 1-18GHz 0.5-18GHz Cal. Date 09 09 09 09 09 SCHWARZB ECK MESS-ELEK TROM/ AK 9513 09 Due Date 10 10 10 10 10 10 C&C LAB/ CC-C-IF N/A N/A SUNSPO/ N/A N/A SP-14C ROHDE&SC 101155 W2005 HWARZ/ 9k-3GHz 001 09 10 ESPI EMI Beijingkehua KH3931 9k-1GHz Receiver n 09 10 Two-Line ROHDE&SC 100115 W2005 V-Network HWARZ/ 50Ω/50μΗ 002 09 10 ENV216 V-LISN SCHWARZB NSLK 8128-2 9k-30MHz Cert. No Wws200 81596 Wws200 80942 Wws200 80941 Uncertainty ±1dB ±1dB f<10 GHz: ±1dB 10GHz<f< 18 GHz:±1.5dB ±1.2dB - ±1dB ±10%
Reference No.: WTS14S0513592E Page 7 of 44 Equipment Name Absorbing Clamp 10m 50 Ohm Coaxial Cable with N-plug, individual length,usa ble up to 3(5)GHz, Connector s Digital Power Analyzer Power Source Electrostat ic Discharge Simulator RF Generator CDN M-Type EM-Clamp Attenuator 6dB All Modules Generator Manufacturer Model ECK MESS-ELEK TRONIK ROHDE&SC HWARZ/ MDS-21 SCHWARZB ECK MESS-ELEK TROM/ AK 9514 Em Test AG/Switzerla nd/ DPA 500 Em Test AG/Switzerla nd/ ACS 500 Em Test AG/Switzerla nd/dito TESEQ GmbH/ NSG4070 TESEQ GmbH/ CDN M016 TESEQ GmbH/ KEMZ 801 TESEQ GmbH/ ATN6050 SCHAFFNER /6150 Equipm Interna Cal. Due Specification ent No l No Date Date 8128 59 09 10 100205 W2005 003 V07451 03095 V07451 03096 V07451 03094 25781 25112 25453 25365 34579 W2008 012 W2008 013 W2008 005 W2008 008 W2008 009 W2008 010 W2008 006 impandance50 Ω Loss: 17 db Fraq-range: 9K-1GHz RF voltage:-60 dbm-+10dbm Voltage correct factor 9.5 db Freq_range:0.1 5-1000 MHz voltage:200v-4.4kv Pulse current:100a-2. 09 09 Power:2000VA Vol-range:0-30 0V Freq_range:10-80Hz Vol-range:0-30 0V Power_freq:10-80Hz Contact discharge:500v -10KV Air diacharge:500 V-16.5KV 09 09 09 09 Power_freq distinguish0. 1Hz RFeletricity distinguish 0.1B 150K-80MHz :±1dB 80-230MHz:- 2-+3dB 0.3-400 MHz:±4dB Other freq:±5db 09 09 09 10 10 10 10 10 10 10 10 10 Cert. No Wws200 80943 Wwd200 81185 Wwc200 82400 Wws200 81890 Wwc200 82396 Wwc200 82397 Wws200 81597 Wwc200 82401 Uncertainty ±1dB Voltage distinguish:0. 025% Power_freq distinguish:0. 02Hz 7.5A current will be changed in V m =1.5V voltage: ±10% Pulse current:±10
Reference No.: WTS14S0513592E Page 8 of 44 Equipment Name Capacitive Coupling Clamp Signal and Data Line Coupling Network AC Power Supply Exposure Level Tester ELT-400 Magnetic Field Probe 100cm 2 Active Loop Antenna Charger 10kHz-30 MHz Manufacturer Model SCHAFFNER / CDN 8014 SCHAFFNER / CDN 117 TONGYUN/ DTDGC-4 Narda Safety TEST Solutions/230 4/03 Narda Safety TEST Solutions/230 0/90.10 Beijing Dazhi / ZN30900A Equipm ent No 25311 25627 M-0155 M-1070 Interna l No W2008 011 w2008 022 w2008 021 Specification Cal. Due Date Date Cert. No Uncertainty 2KA % 1.2/50μS Test freq range:1-400khz Test freq range:1-400khz - - 10kHz-30MHz 09 09 09 09 09 10 10 10 10 10 Wwc200 82398 Wwc200 82399 Wws200 80944 Wwd200 81191 - - - Test uncertainly: 1-120kHz:±1.8 3%, 120 khz-400 khz:±4.06% Test uncertainly: 1Hz-10Hz: ±16.2%, 10Hz -120kHz:±2. 2%, 120 khz-400 khz:±4.7% ±1dB 4.2 Measurement Uncertainty Test Item Frequency Range Uncertainty Note Conduction disturbance 150kHz~30MHz 3.64dB (1) Radiation 30MHz~1000MHz 5.03dB (1) (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.
Reference No.: WTS14S0513592E Page 9 of 44 5 Emission Test Results 5.1 Mains Input Terminals Disturbance Voltage, 150kHz to 30MHz Test Requirement... : EN 62040-2 Test Method... : EN 62040-2 Test Result... : Pass Frequency Range... : 150kHz to 30MHz Class/Severity... : Category C1 / Table 1 of EN 62040-2 5.1.1 E.U.T. Operation Operating Environment: Temperature... : 24.0 C Humidity... : 52.6%RH Atmospheric Pressure... : 101.2kPa EUT Operation: Power Input Voltage... : AC 230V/50Hz Operating Mode... : Charging mode 5.1.2 Block Diagram of Test Setup The Mains Input Terminals Disturbance Voltage tests were performed in accordance with the EN 62040-2. 0.4m EUT Receiver PC System 0.8m 0.8m LISN 5.1.3 Measurement Data : 50 Terminator The maximized peak emissions from the EUT was scanned and measured for both the Live and Neutral Lines. Quasi-peak & average measurements were performed if peak emissions were within 6dB of the average limit line.
Reference No.: WTS14S0513592E Page 10 of 44 5.1.4 Mains Terminals Disturbance Voltage Test Data Live Line:
Reference No.: WTS14S0513592E Page 11 of 44 Neutral Line:
Reference No.: WTS14S0513592E Page 12 of 44 5.2 Radiation Emission, 30MHz to 1000MHz Test Requirement... : EN 62040-2 Test Method... : EN 62040-2 Test Result... : Frequency Range... : Pass 30MHz to 1000MHz Class/Severity... : Category C1/ Table 3 of EN 62040-2 5.2.1 E.U.T. Operation Operating Environment: Temperature... : 23 C Humidity... : 52.5%RH Atmospheric Pressure... : 101kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : Charging mode and Discharging mode Remark... : The worst case is Discharging mode and the data are listed in next pages. 5.2.2 Block Diagram of Test Setup The Radiation emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the setup accordance with the EN 62040-2. Semi-anechoic 3m Chamber Antenna Elevation Varies From 1 to 4 m Turn Table From 0 to 360 3m EUT 0.8m Turn Table PC System Spectrum Analyzer AMP Combining Network 5.2.3 Measurement Data The maximised peak emissions from the EUT was scanned and measured for both the Antenna Vertical Polarization and Antenna Horizontal Polarization. Quasi-peak measurements were performed if peak emissions were within 6dB of the Quasi-peak limit line.
Reference No.: WTS14S0513592E Page 13 of 44 5.2.4 Radiation Emission test data, 30MHz to 1000MHz Antenna polarization: Vertical
Reference No.: WTS14S0513592E Page 14 of 44 Antenna polarization: Horizontal
Reference No.: WTS14S0513592E Page 15 of 44 5.3 Harmonics Current Test Requirement... : EN 61000-3-2 Test Method... : EN 61000-4-7 Test Result... : Pass Class/Severity... : Remark... : 5.3.1 E.U.T. Operation Operating Environment: Temperature... : Humidity... : Atmospheric Pressure... : Class A This testing item only apply for AC Power input. 23 C 50.4%RH 101kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : Charging mode 5.3.2 Block Diagram of Setup The Harmonics Current test was performed in accordance with the EN 61000-3-7. EUT AC Mains Power Analyzer AC Source 0.8m
Reference No.: WTS14S0513592E Page 16 of 44 5.3.3 Harmonic Current Test Data Standard used: EN/IEC 61000-3-2 Ed.3 Short cyclic Equipment class A <= 150% of the limit Observation time: 150s Windows width: 10 periods - (EN/IEC 61000-4-7 Edition 2002) E. U. T. Result Harmonic(s) > 200%: Order (n): None Harmonic(s) with average > 90%: Order (n): None Harmonic(s) between 150% and 200% during more than 10% of the test time or max. 10min: Order (n): None Power Source Result First dataset out of limit: DS (time): Harmonic(s) out of limit: Order (n): None None
Reference No.: WTS14S0513592E Page 17 of 44 Average harmonic current results Hn Ieff [A] Ieff [%] Limit [A] Result 1 5.126 100.000 2 3.675E-3 0.072 972.00E-3 PASS 3 273.015E-3 5.326 2.07 PASS 4 3.445E-3 0.067 387.00E-3 PASS 5 184.574E-3 3.601 1.03 PASS 6 1.897E-3 0.037 270.00E-3 PASS 7 160.854E-3 3.138 693.00E-3 PASS 8 1.543E-3 0.030 207.00E-3 PASS 9 111.755E-3 2.180 360.00E-3 PASS 10 1.871E-3 0.037 165.60E-3 PASS 11 73.919E-3 1.442 297.00E-3 PASS 12 1.244E-3 0.024 138.00E-3 PASS 13 39.198E-3 0.765 189.00E-3 PASS 14 1.136E-3 0.022 118.29E-3 PASS 15 14.037E-3 0.274 135.00E-3 PASS 16 792.052E-6 0.015 103.50E-3 PASS 17 7.483E-3 0.146 119.11E-3 PASS 18 1.036E-3 0.020 92.00E-3 PASS 19 13.722E-3 0.268 106.58E-3 PASS 20 699.108E-6 0.014 82.80E-3 PASS 21 11.801E-3 0.230 96.43E-3 PASS 22 1.038E-3 0.020 75.28E-3 PASS 23 9.416E-3 0.184 88.05E-3 PASS 24 755.938E-6 0.015 68.99E-3 PASS 25 1.906E-3 0.037 81.00E-3 PASS 26 808.937E-6 0.016 63.69E-3 PASS 27 1.916E-3 0.037 75.00E-3 PASS 28 715.259E-6 0.014 59.14E-3 PASS 29 5.781E-3 0.113 69.83E-3 PASS 30 708.791E-6 0.014 55.20E-3 PASS 31 4.041E-3 0.079 65.32E-3 PASS 32 736.351E-6 0.014 51.75E-3 PASS 33 3.282E-3 0.064 61.36E-3 PASS 34 684.080E-6 0.013 48.71E-3 PASS 35 1.425E-3 0.028 57.86E-3 PASS 36 708.139E-6 0.014 46.00E-3 PASS 37 1.232E-3 0.024 54.73E-3 PASS 38 696.737E-6 0.014 43.58E-3 PASS 39 2.677E-3 0.052 51.92E-3 PASS 40 859.833E-6 0.017 41.40E-3 PASS
Reference No.: WTS14S0513592E Page 18 of 44 Maximum harmonic current results Hn Ieff [A] Ieff [%] Limit [A] Result 1 5.132 100.000 2 4.002E-3 0.078 2.16 PASS 3 282.695E-3 5.508 4.60 PASS 4 3.660E-3 0.071 860.00E-3 PASS 5 191.180E-3 3.725 2.28 PASS 6 2.059E-3 0.040 600.00E-3 PASS 7 165.836E-3 3.231 1.54 PASS 8 1.781E-3 0.035 460.00E-3 PASS 9 114.332E-3 2.228 800.00E-3 PASS 10 1.980E-3 0.039 368.00E-3 PASS 11 74.713E-3 1.456 660.00E-3 PASS 12 1.366E-3 0.027 306.66E-3 PASS 13 39.766E-3 0.775 420.00E-3 PASS 14 1.249E-3 0.024 262.86E-3 PASS 15 14.462E-3 0.282 300.00E-3 PASS 16 874.932E-6 0.017 230.00E-3 PASS 17 8.707E-3 0.170 264.70E-3 PASS 18 1.178E-3 0.023 204.44E-3 PASS 19 14.860E-3 0.290 236.84E-3 PASS 20 798.537E-6 0.016 184.00E-3 PASS 21 12.039E-3 0.235 214.28E-3 PASS 22 1.145E-3 0.022 167.28E-3 PASS 23 9.752E-3 0.190 195.66E-3 PASS 24 919.989E-6 0.018 153.32E-3 PASS 25 2.267E-3 0.044 180.00E-3 PASS 26 981.957E-6 0.019 141.54E-3 PASS 27 2.694E-3 0.052 166.66E-3 PASS 28 809.971E-6 0.016 131.42E-3 PASS 29 6.168E-3 0.120 155.18E-3 PASS 30 802.762E-6 0.016 122.66E-3 PASS 31 4.323E-3 0.084 145.16E-3 PASS 32 830.673E-6 0.016 115.00E-3 PASS 33 3.508E-3 0.068 136.36E-3 PASS 34 770.275E-6 0.015 108.24E-3 PASS 35 1.610E-3 0.031 128.58E-3 PASS 36 843.283E-6 0.016 102.22E-3 PASS 37 1.595E-3 0.031 121.62E-3 PASS 38 867.785E-6 0.017 96.84E-3 PASS 39 3.087E-3 0.060 115.38E-3 PASS 40 978.014E-6 0.019 92.00E-3 PASS
Reference No.: WTS14S0513592E Page 19 of 44 Maximum harmonic voltage results Hn Ueff [V] Ueff [%] Limit [%] Result 1 230.08 100.033 2 81.79E-3 0.036 0.2 PASS 3 88.42E-3 0.038 0.9 PASS 4 16.15E-3 0.007 0.2 PASS 5 77.46E-3 0.034 0.4 PASS 6 11.37E-3 0.005 0.2 PASS 7 94.07E-3 0.041 0.3 PASS 8 16.47E-3 0.007 0.2 PASS 9 71.98E-3 0.031 0.2 PASS 10 16.10E-3 0.007 0.2 PASS 11 87.65E-3 0.038 0.1 PASS 12 16.53E-3 0.007 0.1 PASS 13 66.74E-3 0.029 0.1 PASS 14 10.77E-3 0.005 0.1 PASS 15 29.83E-3 0.013 0.1 PASS 16 7.48E-3 0.003 0.1 PASS 17 97.41E-3 0.042 0.1 PASS 18 10.67E-3 0.005 0.1 PASS 19 72.10E-3 0.031 0.1 PASS 20 12.10E-3 0.005 0.1 PASS 21 44.57E-3 0.019 0.1 PASS 22 10.35E-3 0.004 0.1 PASS 23 87.36E-3 0.038 0.1 PASS 24 8.99E-3 0.004 0.1 PASS 25 68.53E-3 0.030 0.1 PASS 26 7.88E-3 0.003 0.1 PASS 27 38.88E-3 0.017 0.1 PASS 28 8.88E-3 0.004 0.1 PASS 29 82.32E-3 0.036 0.1 PASS 30 8.12E-3 0.004 0.1 PASS 31 62.67E-3 0.027 0.1 PASS 32 10.30E-3 0.004 0.1 PASS 33 43.73E-3 0.019 0.1 PASS 34 8.70E-3 0.004 0.1 PASS 35 73.96E-3 0.032 0.1 PASS 36 8.77E-3 0.004 0.1 PASS 37 49.17E-3 0.021 0.1 PASS 38 9.78E-3 0.004 0.1 PASS 39 42.61E-3 0.019 0.1 PASS 40 7.43E-3 0.003 0.1 PASS
Reference No.: WTS14S0513592E Page 20 of 44
Reference No.: WTS14S0513592E Page 21 of 44
Reference No.: WTS14S0513592E Page 22 of 44 5.4 Voltage Fluctuation and Flicker Test Requirement... : EN 61000-3-3 Test Method... : EN 61000-4-15 Test Result... : Remark... : Pass This testing item only apply for AC Power input. 5.4.1 E.U.T. Operation Operating Environment: Temperature... : 21.5 C Humidity... : 52.1%RH Barometric Pressure... : 101.2kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : Charging mode 5.4.2 Block Diagram of Test Setup The Voltage Fluctuation and Flicker test was performed in accordance with the EN 61000-4-15. EUT AC Mains Power Analyzer AC Source 0.8m
Reference No.: WTS14S0513592E Page 23 of 44 5.4.3 Voltage Fluctuation and Flicker Test Data Standard used: Observation time: EN/IEC 61000-3-3 Flicker 10 min (1 Flicker measurement) Test Result PASS Maximum Flicker results EUT values Limit Result Pst 0.501 1.00 PASS Plt 0.503 0.65 PASS dc [%] 2.244 3.30 PASS dmax [%] 2.347 4.00 PASS dt [s] 0.000 0.50 PASS
Reference No.: WTS14S0513592E Page 24 of 44 6 Immunity Test Results 6.1 Performance Criteria Performance criterion A: The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Performance criterion B: The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level (or permissible loss of performance) specified by the manufacturer, when the apparatus is used as intended. During the test, degradation of performance is allowed, however, no change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Performance criterion C: Temporary loss of function is allowed, provided the function itselfrecoverable or can be restored by the operation of the controls, or by any operation specified in the instructions for use. For further details, please refer to EN 62040-2 category C1.
Reference No.: WTS14S0513592E Page 25 of 44 6.2 Electrostatic Discharge (ESD) Test Requirement... : EN 62040-2 Test Method... : EN 61000-4-2 Test Result... : Pass Discharge Impedance... : 330 / 150pF Discharge Voltage... : Air Discharge: ±8kV Contact Discharge: ±4kV HCP & VCP: ±4kV Polarity... : Positive & Negative Number of Discharge... : Minimum 10 times at each test point Discharge Mode... : Single Discharge Discharge Period... : 1 second minimum 6.2.1 E.U.T. Operation Operating Environment: Temperature... : Humidity... : Atmospheric Pressure... : 24 C 52%RH 101.2kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : charging mode and discharging mode 6.2.2 Block Diagram of Setup The ESD test was performed in accordance with the EN 61000-4-2. >1.0m 0.1m Vertical Coupling Plane ESD Generator insulating support Wall EUT 470k ohm 470k ohm Horizontal Coupling Plane 0.8m 470k ohm 470k ohm
Reference No.: WTS14S0513592E Page 26 of 44 6.2.3 Direct Discharge Test Results Observations: Test points: 1. All Exposed Surface & Seams; 2. All metallic part Applied Voltage (kv) Remark: Direct Discharge Performance Criterion Test Results Test Point Contact Discharge Air Discharge ±8 B 1 N/A Pass* ±4 B 2 Pass* N/A * During the test no deviation was detected to the selected operation mode(s) 6.2.4 Indirect Discharge Test Results Observations: Test points: 1. All sides. Applied Voltage (kv) Indirect Discharge Performance Criterion Test Results Test Point Horizontal Coupling Vertical Coupling ±4 B 1 Pass* Pass* Remark: * During the test no deviation was detected to the selected operation mode(s)
Reference No.: WTS14S0513592E Page 27 of 44 6.3 Radio-frequency electromagnetic fields, 80MHz to 1GHz Test Requirement... : EN 62040-2 Test Method... : EN 61000-4-3 Test Result... : Pass Frequency Range... : 80MHz to 1GHz Test level... : 3V/m Modulation... : 80%, 1kHz Amplitude Modulation. Face of EUT... : Front, Back, Left, Right Antenna polarisation... : Horizontal & Vertical 6.3.1 E.U.T. Operation Operating Environment: Temperature... : 24 C Humidity... : 52% RH Barometric Pressure... : 101.2kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : charging mode and discharging mode 6.3.2 Block Diagram of Setup The Radio-frequency electromagnetic fields Immunity test was performed in accordance with the EN 61000-4-3. Anechoic Chamber 3m Gestockte Breitband ( S tacked ) Log.-per.Antenna EUT Camera 0.8m Absorbers 1.5m Signal Generator RF- Amplifier
Reference No.: WTS14S0513592E Page 28 of 44 6.3.3 Test Results Frequency 80 to 1000MHz 80 to 1000MHz Face of EUT Antenna polarisation Test Level Step Size Dwell Time Performance Criterion Result Front, Back, Left, Right Horizontal 3V/m 1% 1s A Pass* Front, Back, Left, Right Vertical 3V/m 1% 1s A Pass* Remark: * During the test no deviation was detected to the selected operation mode(s)
Reference No.: WTS14S0513592E Page 29 of 44 6.4 Electrical Fast Transients (EFT) Test Requirement... : EN 62040-2 Test Method... : EN 61000-4-4 Test Result... : Pass Polarity... : Positive & Negative Repetition Frequency... : 5kHz Burst Duration... : 300ms Test Duration... : 2 minutes per level & polarity 6.4.1 E.U.T. Operation Operating Environment: Temperature... : Humidity... : Atmospheric Pressure... : 23 C 50.3%RH 101kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : charging mode 6.4.2 Block Diagram of Setup The Electrical Fast Transients Immunity test was performed in accordance with the EN 61000-4-4. For AC input power ports: >0.5m Wall 0.1m wood table EUT AC Mains Test Generator For DC power port, AC output power ports, Signal and control ports: >0.5m Wall 0.1m wood table EUT Test AC Mains Clamp Generator
Reference No.: WTS14S0513592E Page 30 of 44 6.4.3 Test Results Test Port Test Level(kV) Performance Criterion Result Line-Neutral-PE (AC Input port) Line-Neutral-PE (AC Output port) 1.0 B PASS * 1.0 B PASS * DC power port 1.0 B N/A * Signal and control port 1.0 B N/A * Remark: * During the test no deviation was detected to the selected operation mode(s)
Reference No.: WTS14S0513592E Page 31 of 44 6.5 Surge Test Requirement... : EN 62040-2 Test Method... : EN 61000-4-5 Test Result... : Pass Interval... : 60s between each surge No. of surges... : 5 positive at 90, 5 negative at 270. 6.5.1 E.U.T. Operation Operating Environment: Temperature... : Humidity... : Atmospheric Pressure... : 24 C 52%RH 101.2kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : charging mode 6.5.2 Block Diagram of Setup The Surge Immunity test was performed in accordance with the EN 61000-4-5. AC input power ports: >0.5m Wall 0.1m wood table EUT AC Mains Test Generator AC output power ports: >0.5m Wall 0.1m wood table EUT AC Mains Clamp Test Generator
Reference No.: WTS14S0513592E Page 32 of 44 6.5.3 Test Results AC Input port: Test Port Applied Voltage (kv) Performance criterion Result Between Live And Neutral: 1 B PASS * Between Live And Earth: 2 B PASS * Between Neutral And Earth: 2 B PASS * Signal and control port 1 B N/A * AC Output port: Test Port Applied Voltage (kv) Performance criterion Result Between Live And Neutral: 1 B PASS * Between Live And Earth: 2 B PASS * Between Neutral And Earth: 2 B PASS * Signal and control port 1 B N/A * Remark: * During the test no deviation was detected to the selected operation mode(s)
Reference No.: WTS14S0513592E Page 33 of 44 6.6 Injected Currents Immunity, 0.15MHz to 80MHz Test Requirement... : EN 62040-2 Test Method... : EN 61000-4-6 Test Result... : Pass Frequency Range... : 0.15MHz to 80MHz Modulation... : 80%, 1kHz Amplitude Modulation. 6.6.1 E.U.T. Operation Operating Environment: Temperature... : Humidity... : Atmospheric Pressure... : 24 C 52%RH 101.2kPa EUT Operation: Input Voltage... : AC 230V/50Hz Operating Mode... : charging mode 6.6.2 Block Diagram of Setup The Injected Currents Immunity test was performed in accordance with the IEC 61000-4-6. AC input power ports: 0.1m< L <0.3m 0.1m Wood Table EUT CDN AC Mains Attenuator 6dB Signal Generator Power Amplifier AC output power, Signal and control ports: 0.1m wood table EUT Attenuator 6dB Clamp Signal Generator Power Amplifier
Reference No.: WTS14S0513592E Page 34 of 44 6.6.3 Test Results Frequency Line Test Level Modulation Step Size Dwell Time Performance Criterion Result 150kHz to 80MHz 3 Wire AC Input Supply Cables 3Vr.m.s. 80%, 1kHz Amp. Mod. 1% 1s A PASS * 150kHz to 80MHz 3 Wire AC Output Supply Cables 3Vr.m.s. 80%, 1kHz Amp. Mod. 1% 1s A PASS * 150kHz to 80MHz Signal or control ports 3Vr.m.s. 80%, 1kHz Amp. Mod. 1% 1s A N/A * Remark: * During the test no deviation was detected to the selected operation mode(s)
Reference No.: WTS14S0513592E Page 35 of 44 7 Photographs Test Setup 7.1 Photograph Mains Input Terminal Disturbance Voltage Test Setup 7.2 Photograph Radiation Emission Test Setup
Reference No.: WTS14S0513592E Page 36 of 44 7.3 Photograph Harmonic Current and Flicker Test Setup 7.4 Photograph ESD Immunity Test Setup
Reference No.: WTS14S0513592E Page 37 of 44 7.5 Photograph Radio-frequency electromagnetic fields Test Setup 7.6 Photograph EFT & Surge Immunity Test Setup
Reference No.: WTS14S0513592E Page 38 of 44 7.7 Photograph Injected Currents Immunity Test Setup
Reference No.: WTS14S0513592E Page 39 of 44 8 Photographs Constructional Details 8.1 EUT Appearance View
Reference No.: WTS14S0513592E Page 40 of 44 8.2 EUT Open View
Reference No.: WTS14S0513592E Page 41 of 44
Reference No.: WTS14S0513592E Page 42 of 44
Reference No.: WTS14S0513592E Page 43 of 44
Reference No.: WTS14S0513592E Page 44 of 44 ======End of Report======