n Compatible with RoHS EU Directive 2002/95/EC (-Z Versions) n High efficiency: 92.5% typical n Industry standard pinout n Isolation voltage:2250 Vdc

Similar documents
SE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W

n Compatible with RoHS EU Directive /EC n Compatible in Pb- free or SnPb reflow environment n Nonisolated output n High efficiency: 86% typical

QBW025A0B Series Power Modules; DC-DC Converters Vdc Input; 12Vdc Output; 25 A

QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A. RoHS Compliant. Data Sheet April 7, 2006.

QPW050/060 Series Power Modules; DC-DC converters 36-75Vdc Input; 1.2Vdc to 3.3Vdc Output

EQD075 Series (Eighth-Brick)DC-DC Converter Power Modules 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W

Naos Raptor 6A: Non-Isolated DC-DC Power Modules 4.5Vdc 14Vdc input; 0.59Vdc to 6Vdc Output; 6A Output Current

QPW025A0F41/QPW025A0F41-H DC-DC Power Module 36-75Vdc Input; 3.3Vdc Output Voltage; 25A Output Current

NaOS TM NXA025 SIP Non-isolated Power Modules: 10Vdc 14Vdc Input; 0.8Vdc to 5.5Vdc Output; 25A Output Current

Naos Raptor 20A: Non-Isolated Power Modules Vdc input; 0.59Vdc to 6Vdc Output; 20A Output Current

Naos Raptor 60A: Non-Isolated Power Modules Vdc input; 0.6Vdc to 5.0Vdc Output; 60A Output Current

24 Austin Lynx TM : Non-Isolated DC-DC Power Modules 20Vdc 30Vdc input; 5.0 Vdc to 15 Vdc output; 70W Output Power

Austin Minilynx TM 12V SIP Non-isolated Power Modules: Vdc Input; 0.75Vdc to 5.5 Vdc Output; 3A Output Current

ERCW003A6R Power Modules; DC-DC Converters 36 75Vdc Input; 28Vdc Output; 3.6Adc Output ORCA SERIES Features RoHS Compliant Applications Options

NQR010A0X4: Non-Isolated DC-DC Power Modules 4.5Vdc 14Vdc input; 0.59Vdc to 6Vdc Output;10A Output Current

Naos Raptor 10A: Non-Isolated DC-DC Power Modules 4.5Vdc 14Vdc input; 0.59Vdc to 6Vdc Output;10A Output Current

Austin Microlynx TM 12V SIP Non-isolated Power Modules: 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A Output Current

Naos Raptor 6A: Non-Isolated DC-DC Power Modules

Naos Raptor 40A Non-Isolated Power Modules Vdc input; 0.6Vdc to 5.0Vdc Output; 40A Output Current

LC/LW005-Series Power Modules: 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 5 W

JRCW450U Orca* Series; DC-DC Converter Power Modules Vdc Input; 48Vdc Output; 450W Output

12V Austin Lynx TM : SIP Non-Isolated DC-DC Power Modules, Programmable 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current

12V Austin MiniLynx TM : SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 3A Output Current

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Austin MicroLynx TM : SIP Non-Isolated DC-DC Power Modules 3Vdc 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 5A Output Current

LW020 Single-Output-Series Power Modules: 36 Vdc to 75 Vdc Inputs; 20 W

HC006/010 Series Power Modules; dc-dc Converters 18-36Vdc Input; 3.3Vdc & 5Vdc Outputs; 6.6A to 10A Current

SHHD003A0A Hammerhead* Series; DC-DC Converter Power Modules 18-75Vdc Input; 5.0Vdc, 3A, 15W Output

Austin Lynx TM : SIP Non-Isolated DC-DC Power Modules, Programmable 3.0Vdc 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 10A Output Current

JRCW016A0R Orca * Series; DC-DC Converter Power Modules Vdc Input; 28Vdc Output; 16Adc Output

RoHS Compliant. Data Sheet. Features. Applications. Description. April 19, Compliant to RoHS EU Directive 2002/95/EC (- Z versions)

12V Austin SuperLynx TM 16A: SIP Non-Isolated DC-DC Power Module 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current

S24SP series 60W Single Output DC/DC Converter

EQW006 Series, Eighth-Brick Power Modules: DC-DC Converter 36 75Vdc Input; 12Vdc Output; 6A Output Current

TBD. Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W FEATURES OPTIONS APPLICATIONS

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

S24SE/S24DE series 15W Single/Dual Output DC/DC Converter

Delphi Series H48SC3R325, 85W Half Brick Family DC/DC Power Modules: 48V in, 3.3V/25A out

JNW350R Power Modules; DC-DC Converters Vdc Input; 28Vdc Output; 350W Output

Cool Power Technologies

AA SERIES (1 x 1 Package) Up to 10 Watt DC-DC Converter

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power


QSTS015A0S10R0 BARRACUDA* Series; DC-DC Converter Power Modules 45Vdc 65Vdc input; 10Vdc output; 15A Output Current

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

PRODUCT OVERVIEW. APPLICATIONS: Distributed Power Architectures Mobile telecommunication Industrial applications Battery operated equipment

FLTR100V20 Filter Module 75 Vdc Input Maximum, 20 A Maximum

FLTR100V10 Filter Module 75 Vdc Input Maximum, 10 A Maximum

AA SERIES (1 x 1 Package) Up to 30 Watt DC-DC Converter

NQR002A. Data Sheet. Features. Application. Description. Compatible in. 0.6Vdc to 5.5Vdc, via external resistor Tunable Loop response.

BARRACUDA SERIES Features

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

12V Austin SuperLynx TM II: SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current

GE Energy. 6A Austin MicroLynx II TM : 12V SIP Non-Isolated DC-DC Power Module. Data Sheet. RoHS Compliant

OVP 2:1. Wide Range. Protection

12V Austin Lynx TM II: SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current

Delphi Series H48SA, 450W Half Brick Family

(DOSA) VDC, 5.5 A.

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 15V/4A out

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 12V/10A out

(typ.) (Range) Parameter Model Min. Typ. Max. Unit

H80SV12017 * * FEATURES. Delphi Series H80SV, half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12Vout,200W APPLICATIONS

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

PXD30-xxWS-xx-Single Output DC/DC Converters

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

V36SE12005 FEATURES. Delphi Series V36SE, 1/16 th. Brick DC/DC Power Modules: 18~75Vin, up to 60W OPTIONS APPLICATIONS

GE Energy. 6A Austin MicroLynx II TM : SIP Non-Isolated DC-DC Power Module. Data Sheet. RoHS Compliant EZ-SEQUENCE TM

Delphi Series Q48SK, Quarter Brick Family DC/DC Power Modules: 36~75V in, 12V/18A out, 216W

V36SE12004 FEATURES. Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W OPTIONS APPLICATIONS

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, 3.3Vo, 50W

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

Delphi Series S36SA, 25W Family DC/DC Power Modules: 18Vin to 60Vin, 3.3V/8A out

Q54SJ W DC/DC Power Modules FEATURES. Q54SJ12058, 700W Quarter Brick DC/DC Power Modules: 40~60Vin, 12.2V/ 57.4A out OPTIONS APPLICATIONS

AS SERIES (2.00 x 1.6 Package) Up to 20 Watt DC-DC Converter

Delphi Series T48SR, 1/32 Brick Family DC/DC Power Modules: 36~75V in, 5V/5A out, 25W FEATURES OPTIONS APPLICATIONS

Austin MiniLynx TM : SMT Non-Isolated DC-DC Power Modules 2.4Vdc 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 3A Output Current

MIW3000 Series EMI. 5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Delphi Series V48SR, 1/16 th Brick 66W

Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W

Efficiency (typ.) (Range) Max. Load VDC VDC ma ma ma(typ.) ma(typ.) μf % MJWI10-24S033

Naos TM NXA025: SMT Non-Isolated DC-DC Power Module 10Vdc 14Vdc input; 0.8Vdc to 5.5Vdc output; 25A Output Current

IND072 Hornet TM : Non-Isolated DC-DC Voltage Regulator Modules

Delphi Series H48SA, 150W Half Brick Family DC/DC Power Modules: 36~75V in, 48V/3.2A out

Austin Microlynx TM 12V SMT Non-isolated Power Modules: 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A Output Current

Delphi Series E48SP Eighth Brick Family DC/DC Power Modules: 48V in, 12V/20A out

12V Austin MiniLynx TM : SMT Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 3A Output Current

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 5V/20A out

QHHD019A0B Hammerhead* Series; DC-DC Converter Power Modules 18Vdc 75Vdc input; 12Vdc output; 19A Output Current

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

Delphi Series S48SP, 35W 1x1 Brick DC/DC Power Modules: 48V in, 5V/7A out

PXD10-Single Output DC/DC Converter

` FEATURES. Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.0V/50A out OPTIONS APPLICATIONS

APTS/APXS003A0X: Non-Isolated DC-DC Power Modules: 4.5Vdc 14Vdc input; 0.59Vdc to 5.5Vdc output; 3A Output Current

Delphi Series Q36SR, Quarter Brick 204W DC/DC Power Modules: 18V~75Vin,12V, 17Aout

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.8V/40A out

36-75 Vdc DC/DC converter Output up to 30 A/90 W

12V Austin MicroLynx TM 5A: Non-Isolated DC-DC Power Module 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A Output Current

PM24S/DR24S series 60W Single Output DC/DC Converter

Austin MicroLynx TM 5A: Non-Isolated DC-DC Power Module 3.0Vdc 5.8Vdc input; 0.75Vdc to 4.0Vdc output; 5A Output Current

Transcription:

Applications n Enterprise Networks n Distributed power architectures n Voice Over IP n Local Area Networks n Isolated Bus Voltage applications. Options RoHS Compliant n Choice of Remote On/Off option Features n Compatible with RoHS EU Directive 2002/95/EC (-Z Versions) n Compatible in RoHS EU Directive 2002/95/EC with lead solder exemption (non -Z versions) n High efficiency: 92.5% typical n Industry standard Half Brick: 61.0mm x 57.9 mm x 12.7 mm (2.4 in x 2.28 in x 0.43 in) n Industry standard pinout n Isolation voltage:2250 Vdc n Open-frame construction n 2:1 input voltage range n Remote Sense/Remote On/Off n Auto restart after fault shutdown n Constant switching frequency n Output overvoltage and Overcurrent protection n Overtemperature protection n Adjustable output voltage (trim) n Meets the voltage and current requirements for ETSI 300-132-2 and complies with and is approved for Basic Insulation rating per EN60950-1 n UL* 60950 Recognized, CSA C22.2 No. 60950-00 Certified, and VDE 0805 (IEC60950, 3rd edition) Licensed n CE mark meets 73/23/EEC and 93/68/EEC directives n ISO** 9001 certified manufacturing facilities Description The JPW200S52R5-BH Power Module is a dc-dc converter that operates over an input voltage range of 38 Vdc to 75 Vdc and provides a precisely regulated dc output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The module has a maximum power rating of 200 W at a typical full-load efficiency of 92.5%. The open-frame module offers direct cooling of dissipative components for excellent thermal performance. The optional baseplate is offered to provide easy mounting of a heat sink, for high-temperature applications. The standard feature set includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.v. This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the Internation Organization of Standards Document Name:DS03-090 ver. 1.2 PDF Name:jpw200s52r5-bh.pdf

Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliabiltiy. Parameter Device Symbol Min Max Unit Input Voltage:Continuous All VI 75 Vdc Operating Ambient Temperature All TA 40 85 C (See Thermal Considerations section) Storage Temperature All Tstg 55 125 C I/O Isolation Voltage 2250 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Symbol Min Typ Max Unit Operating Input Voltage VIN 38 52 75 Vdc Under Voltage Lock-out turn on turn off Maximum Input Current (VI = 0 V to 75 V; IO = IO, max) VITON VITOFF CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 10 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer s data for further information. 36.5 34.6 37.9 36 Vdc Vdc 7.0 Adc Inrush Transient I 2 t 2 A 2 s Input Current @ No Output Load Iin, no load 140 ma (VI = 52 Vdc; Io = 0A; TA = 25 C; on/off pin enabled Input Reflected Ripple Current, peak-peak 5 map-p (5 Hz to 20 MHz, 12 µh source impedance See Test configuration section) Input Ripple Rejection (120 Hz)@Vin=52V 34 db Lineage Power 2

Electrical Specifications (continued) Output Specifications Output Voltage Set Point (VI = 52 V; IO = IO, max; TA= 25 C) Parameter Symbol Min Typ Max Unit Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life. See Figure 11.) Output Regulation: Line (VI = 38 V to 75 V) Load (IO = IO, min to IO, max) Temperature (TA = 40 C to +85 C) VO, set 51.19 52.5 53.55 Vdc VO 50.90 54.08 Vdc 0.01 0.05 100 0.2 0.4 300 %VO %VO mv Output Ripple and Noise Voltage (See Figure 10.): RMS Peak-to-peak (5 Hz to 20 MHz) External Load Capacitance (ESR < 150 mohm) 200 1000 µf Output Current IO 0 3.81 A 115 345 mvrms mvp-p Output Current-limit Inception IO, cli 4.0 5.5 A (VO = 90% of VO, nom) Output Short-circuit Current (VO = 250 mv) 170 %IO, max Efficiency h 92.5 % (VI = 52 V; IO = IO, max; TA = 25 C) Switching Frequency All 300 khz Dynamic Response (DIO/Dt = 1 A/µs, VI = 52 V, TA = 25 C; tested with a 200 µf aluminum and a 1.0 µf ceramic capacitor across the load): Load Change from IO = 50% to 75% of IO, max: Peak Deviation Settling Time (VO < 10% of peak deviation) Load Change from IO = 50% to 25% of IO, max: Peak Deviation Settling Time (VO < 10% of peak deviation) Isolation Specifications 165 2 165 2 200 4 200 4 mv ms mv ms Parameter Min Typ Max Unit Isolation Capacitance 6000 pf Isolation Resistance 10 MΩ General Specifications Parameter Min Typ Max Unit Calculated MTBF (IO = 80% of IO, max TA = 40 C,standard half brick 1,260,000 Hours 0.75 inch heatsink) Weight 71(2.5) g (oz.) Lineage Power 3

Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Symbol Min Typ Max Unit Remote On/Off Signal Interface (VI = 38 V to 75 V; open collector or equivalent compatible; signal referenced to VI( ) terminal; see Figure 12 and Feature Descriptions.): JPW200S52R51-BH Preferred Logic: Logic LowModule On Logic HighModule Off JPW200S52R5-BH Optional Logic: Logic LowModule Off Logic HighModule On Logic Low: At Ion/off = 1.0 ma At Von/off = 0.0 V Logic High: At Ion/off = 0.0 µa Leakage Current Turn-On Delay and Rise Times (IO=IO, max) Von/off Ion/off Von/off Ion/off 0 0.3 1.0 5V 50 V ma V µa Tdelay = Time until VO = 10% of VO,set from either application of Vin with Remote On/Off set to On or operation of Remote On/Off from Off to On with Vin already applied for at least one second. Trise = time for VO to rise from 10% of VO,set to 90% of VO,set. Tdelay, on/off Trise, on/off Tdelay, Vin Trise, Vin 12 25 25 25 ms ms ms ms Output Voltage Adjustment (See Feature Descriptions.): Output Voltage Remote-sense Range Output Voltage Set-point Adjustment Range (trim) Note: Ensure that the combination of remote sense and trim do not exceed 56.5 V on the output. 95 0.5 104 V %VO, nom Output Overvoltage Protection VO, clamp 56.5 58.5 V Overtemperature Protection (shutdown) TC 100 C Lineage Power 4

Characteristic Curves The following figures provide typical characteristics curves for the power module at room temperature (TA = 25 C).The figures are identical for both on/off configurations. Io = 3.8A Io = 1.9A Io = 0.1A Figure 1. Input Voltage and Current Characteristics. Figure 3. Typical Converter Efficiency vs. Ouput Current. 60 50 40 30 20 OUTPUT VOLTAGE, Vo (V) (100 mv/div) 10 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 TIME, t (2.00 µs/div) Figure 2. Typical Output Characteristics. Note: Tested with a 200 µf aluminum and a 1.0 µf ceramic capacitor across the load Figure 4. Typical Output Ripple at Io=Io,max. OUTPUT CURRENT, Io (A) OUTPUT VOLTAGE, Vo (V) (100 mv/div) OUTPUT CURRENT, Io (A) (1 A/div) TIME, t TIME, t (1 ms/div) Note: R1 = Ref1 curve; 5A/div; 500mS/div : Trace 1: Zoom detail of current pulse : 5A/div; 20 ms/div;vin = 52Vdc; Cout = 200uF Note: Tested with a 200 µf aluminum and a 1.0 µf ceramic capacitor across the load Figure 5. Typical Transient Response to Step Change Figure 2a. Typical Current limit Hic-cup Characteristics. in Load from 25% to 50% to 25% of Full Load at VI = 52V. Lineage Power 5

Characteristic Curves The following figures provide typical characteristics curves for the power module at room temperature (TA = 25 C) Note: Tested with a 200 µf aluminum and a 1.0 µf ceramic capacitor across the load. Figure 6. TIME, t (1 ms/div) Typical Transient Response to Step Change in Load from 50% to 75% to 50% of Full Load at VI = 52V. Note: Tested with a 200 µf aluminum and a 1.0 µf ceramic capacitor across the load. Figure 8. Typical Start-Up from Vin(IO = IO, max). OUTPUT VOLTAGE, Vo (V) (10 V/div) REMOTE ON/OFF VOLTAGE, Von/off (V) OUTPUT VOLTAGE, Vo (V) (100 mv/div) OUTPUT VOLTAGE, Vo (V) (10 V/div) OUTPUT CURRENT, Io (A) (1 A/div) INPUT VOLTAGE, Vo (V) (20 V/div) TIME, t (10 ms/div) TIME, t (10 ms/div) Note: Tested with a 200 µf aluminum and a 1.0 µf ceramic capacitor across the load. Figure 7. Typical Start-Up from Remote On/Off at Io=Io,max. Lineage Power 6

Test Configurations Design Considerations BATTERY TO OSCILLOSCOPE LTEST 12 μh CS 220 μf ESR < 0.1 Ω @ 20 C, 100 khz CURRENT PROBE 100 μf ESR < 0.7 Ω @ 100 khz VI(+) VI( ) Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. For the test configuration in 9, a 100 µf electrolytic capacitor (ESR < 0.7 W at 100 khz) mounted close to the power module helps ensure stability of the unit. For other highly inductive source impedances, consult the factory for further application guidelines. Note: Measure input reflected-ripple current with a simulated source inductance (LTEST) of 12 µh. Capacitor CS offsets possible battery impedance. Measure current as shown above. Figure 9. VO(+) VO( ) Input Reflected-Ripple Test Setup. Note: The use of a 200 µf aluminum capacitor is needed for stability. Use a 1.0 µf ceramic capacitor on the output. Scope measurement should be made using a BNC socket. Position the load between 51 mm and 76 mm (2 in. and 3 in.) from the module. Figure 10. Peak-to-Peak Output Noise Measurement Test Setup. SUPPLY Note:All measurements are taken at the module terminals. When socketing, place Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance. Figure 11. II CONTACT RESISTANCE COPPER STRIP 1.0 μf SENSE(+) VI(+) VO(+) VI( ) VO( ) SENSE( ) RESISTIVE 200 μf SCOPE LOAD CONTACT AND DISTRIBUTION LOSSES [ V O (+) V O (-)]I O η = ---------------------------------------------- 100 % [ V I (+) V I (-)]I I Output Voltage and Efficiency Measurement. IO LOAD Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950, CSA C22.2 No. 60950-00, and EN 60950 (VDE 0805):2001-12. These converters have been evaluated to the spacing requirements for Basic Insulation per the above safety standards. For Basic Insulation models, 2250 Vdc is applied from Vi to Vo to 100% of outgoing production. For end products connected to 48V dc, or 60Vdc nominal DC MAINS (i.e. central office dc battery plant), no further fault testing is required. *Note: -60V dc nominal battery plants are not available in the U.S. or Canada. For all input voltages, other than DC MAINS, where the input voltage is less than 60V dc, if the input meets all of the requirements for SELV, then: n The output may be considered SELV. Output voltages will remain within SELV limits even with internally-generated non-selv voltages. Single component failure and fault tests were performed in the power converters. n One pole of the input and one pole of the output are to be grounded, or both circuits are to be kept floating, to maintain the output voltage to ground voltage within ELV or SELV limits. For all input sources, other than DC MAINS, where the input voltage is between 60 and 75V dc (Classified as TNV-2 in Europe), the following must be meet, if the converter s output is to be evaluated for SELV: n The input source is to be provided with reinforced insulation from any hazardous voltage, including the ac mains. n One Vi pin and one Vo pin are to be reliably earthed, or both the input and output pins are to be kept floating. Another SELV reliability test is conducted on the whole system, as required by the safety agencies, on the combination of supply source and the subject module to verify that under a single fault, hazardous voltages do not appear at the module s output. The power module has ELV (extra-low voltage) outputs when all inputs are ELV. All flammable materials used in the manufacturing of these Lineage Power 7

modules are rated 94V-0. The input to these units is to be provided with a maximum 10 A fast-acting (or time-delay) fuse in the unearthed lead. Feature Descriptions Overcurrent Protection To provide protection in an overcurrent fault condition, the module is equipped with internal current-limiting circuitry and can endure current limiting for an unlimited duration. Upon current limit inception threshold, the module enters a hiccup mode of operation, whereby it shutdown and automatically attempts to restart. While the overcurrent fault condition persist, the module will remain in the hic-cup mode until the overcurrent fault is cleared. See Figure 2a. Remote On/Off Two remote on/off options are available. Positive logic remote on/off turns the module on during a logic-high voltage on the ON/OFF pin, and off during a logic low. Negative logic remote on/off turns the module off during a logic high and on during a logic low. Negative logic (code suffix 1 ) is the factory-preferred configuration. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal (Von/off) and the VI( ) terminal. The switch can be an open collector or equivalent (see Figure 12). A logic low is Von/off = 0 V to 0.3 V. The maximum Ion/off during a logic low is 1 ma. The switch should maintain a logic-low voltage while sinking 1 ma. During a logic high, the maximum Von/off generated by the power module is 5 V. The maximum allowable leakage current of the switch at Von/off = 5 V is 50 µa. If not using the remote on/off feature, do one of the following: n n. For negative logic, short ON/OFF pin to VI( ). For positive logic, leave ON/OFF pin open. Ion/off + Von/off ON/OFF VI(+) VI( ) SENSE(+) VO(+) VO( ) SENSE( ) Figure 12. Remote On/Off Implementation. LOAD Remote Sense Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections. The voltage between the remote-sense pins and the output terminals must not exceed the output voltage sense range given in the Feature Specifications table, i.e.: [VO(+) VO( )] [SENSE(+) SENSE( )] = 0.5 V The voltage between the VO(+) and VO( ) terminals must not exceed 56.5 V. This limit includes any increase in voltage due to remote-sense compensation and output voltage setpoint adjustment (trim). See Figure 13. If not using the remote-sense feature to regulate the output at the point of load, then connect SENSE(+) to VO(+) and SENSE( ) to VO( ) at the module. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. SUPPLY II CONTACT RESISTANCE VI(+) VI( ) SENSE(+) SENSE( ) VO(+) VO( ) Figure 13. Effective Circuit Configuration for Single-Module Remote-Sense Operation Output Voltage. Output Overvoltage Protection The output overvoltage clamp consists of control circuitry, independent of the primary regulation loop, that monitors the voltage on the output terminals. The over voltage clamp circuit has a higher voltage set point than the primary loop (see Feature Specifications table). This provides a redundant voltage control that reduces the risk of output overvoltage. If the output voltage exceeds the overvoltage threshold, the module enters a hic-cup mode of operation, whereby it shutdown and automatically attempts to restart. While the fault condition exists, the module will remain in the hic-cup mode until the overvoltage fault is cleared. IO LOAD CONTACT AND DISTRIBUTION LOSSES Lineage Power 8

Feature Descriptions (Continued) Overtemperature Protection This module features an overtemperature protection circuit to safeguard against thermal damage. The protection circuit will shutdown the module when the maximum case temperature is exceeded. The module will restart automatically when the case temperature falls below shutdown threshold. Output Voltage Set-Point Adjustment (Trim) Output voltage trim allows the user to increase or decrease the output voltage set point of a module. This is accomplished by connecting an external resistor between the TRIM pin and either the SENSE(+) or SENSE( ) pins. The trim resistor should be positioned close to the module. If not using the trim feature, leave the TRIM pin open. With an external resistor between the TRIM and SENSE( ) pins (Radj-down), the output voltage set point (VO, adj) decreases (see Figure 14). The following equation determines the required external-resistor value to obtain a percentage output voltage change of Δ%. Radj-down 100 = --------- 2 kω Δ% With an external resistor connected between the TRIM and SENSE(+) pins (Radj-up), the output voltage set point (VO, adj) increases (see Figure 15). Note: Do not exceed 56.5 V between the VO(+) and VO( ) terminals. The following equation determines the required externalresistor value to obtain a percentage output voltage change of ý%. VO( 100 + Δ% ) ( 100 + 2Δ% ) Radj-up = ------------------------------------- --------------------------------- kω 1.225Δ% Δ% This limit includes any increase in voltage due to remotesense compensation and output voltage set-point adjustment (trim). See Figure 13. Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum increase is the larger of either the remote sense or the trim. The amount of power delivered by the module is defined as the voltage at the output terminals multiplied by the output current. When using remote sense and trim, the output voltage of the module can be increased, which at the same output current would increase the power output of the module. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. VI(+) ON/OFF CASE VI( ) VO(+) SENSE(+) TRIM SENSE( ) VO( ) Radj-up RLOAD Figure 15. Circuit Configuration to Increase Output Voltage. The voltage between the VO(+) and VO( ) terminals must not exceed the minimum output voltage clamp value as indicated in the Feature Specifications table. VI(+) VO(+) ON/OFF SENSE(+) CASE VI( ) TRIM SENSE( ) Radj-down RLOAD VO( ) Figure 14. Circuit Configuration to Decrease Output Voltage. Lineage Power 9

Thermal Considerations The power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation of the unit. Heat-dissipating components inside the unit are thermally coupled to the base plate. Heat is removed by conduction, convection, and radiation to the surrounding environment. Proper cooling can be verified by measuring the base plate temperature. Peak temperature (TC) occurs at the position indicated in Figure 16. Example What is the minimum airflow necessary for the JPW200S52R5-BH operating at VI = 52 V, an output current of 3.5 A, and a maximum ambient temperature of 40 C? Solution Given: VI = 52 V IO = 3.5 A TA = 40 C Determine airflow (v) (Use Figure 17.): v = 1.0 m (200 ft/min) 6.35 (0.25) MEASURE CASE TEMPERATURE HERE 3.5 VI(+) VO(+) 3.0 ON/OFF + SEN TRIM 2.5 2.0 1.5 1.0 CASE SEN 33.02 0.5 (1.30) VI( ) VO( ) 0.0 20 30 40 50 60 70 80 90 Note:Top view, pin locations are for reference only. O U T P U T CURRENT, I O (A ) 5.0 4.5 4.0 LOCAL AMBIENT TEMPERATURE, T A ( C) Figure 17. Derating Curve for JPW200S52R5-BH (Vo = 52.5V) with base plate; Vin = 52V. Figure 16. Case Temperature Measurement Location. The temperature at this location should not exceed 100 C. The output power of the module should not exceed the rated power for the module as listed in the Ordering Information table. Although the maximum case temperature of the power modules is 100 C, you can limit this temperature to a lower value for extremely high reliability. Heat Transfer Without Heat Sinks EMC Considerations For assistance with designing for EMC compliance, please refer to the FLTR100V10 data sheet (FDS01-043EPS). Layout Considerations Copper paths must not be routed beneath the power module mounting inserts. For additional layout guidelines, refer to the FLTR100V10 data sheet (DS98-152EPS). Increasing airflow over the module enhances the heat transfer via convection. Figure 17 shows the maximum output current that can be delivered by the module without exceeding the maximum case temperature versus local ambient temperature (TA) for natural convection through 3 m/s (600 ft./min.). Note that the natural convection condition was measured at 0.05 m/s to 0.1 m/s (10 ft./min. to 20 ft./min.); however, systems in which these power modules may be used typically generate natural convection airflow rates of 0.3 m/s (60 ft./ min.) due to other heat dissipating components in the system. The use of Figure 17 is shown in the following example. Lineage Power 10

Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3 C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210 C. For Pb solder, the recommended pot temperature is 260 C, while the Pb-free solder pot is 270 C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Tyco Electronics Power System representative for more details. Post Solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note (AP01-056EPS). Lineage Power 11

Outline Diagram Dimensions are in millimeters and (inches) Tolerences: x.x mm 0.5 mm (x.xx in. 0.02 in.) x.xx mm 0.25 mm (x.xxx in. 0.010 in.) 3.2 (.125) X 45 57.4 (2.26) 10.80 (.425) 55.6 (2.19) 43.18 (1.700) V I (-) 2.06 (.081) 2 PLCS V O (-) 50.80 (2.000) 43.18 (1.700) 4.3 TYP (.17) 33.02 (1.300) 17.78 (.700) CASE ON/ OFF SEN (-) 33.02 (1.300) TRIM 25.40 (1.000) SEN (+) 17.78 (.700) 60.5 (2.38) 7.62 (.300) V I (+) V O (+) 7.62 (.300) 4.8 (.19) 4.6 (.18).00 (.000) 1.02 (.040) 7 PLCS 48.26 (1.900) 52.8 (2.08).00 (.000).76 MIN (.03) *Bottom Side label includes Lineage Power name, product designation, and data code.. Lineage Power 12

Recommended Hole Pattern Component side footprint. Dimensions are in millimeters and (inches). 57.9 (2.28) MAX 48.3 (1.90) 48.26 VI (+) (1.900) VO (+) 35.56 (1.400) ON/OFF +SEN 35.56 (1.400) 50.8 (2.00) 25.40 (1.000) 10.16 (0.400) CASE VI ( ) TRIM SEN VO ( ) 10.16 (0.400) 25.40 (1.000) 17.78 (0.700) 61.0 (2.40) MAX MODULE OUTLINE MOUNTING INSERTS Lineage Power 13

Ordering Information For assistance in ordering, please contact your Lineage Power Account Manager or Field Application Engineer for pricing and availability. Input Voltage Output Voltage Output Current Remote On/Off Logic Connector Type Device Code Comcodes 48V 52.5V 200W Negative Through hole JPW200S52R51-BH 108982851 48V 52.5V 200W Negative Through hole JPW200S52R51-BHZ CC109121456 Optional features can be ordered using the suffixes shown in table below. The suffixes follow the last letter of the device code and are placed in descending order. For example, the device codes for a JPW200S52R5-BH module with the following options are shown below: Negative Logic remote on/off JPW200S52R51-BH Option Suffix Negative Logic remote on/off 1 Base plate version for Heat Sink attachment H Pin Length: 3.68 mm ± 0.25 mm 6 (0.145 in. ± 0.010 in) RoHS compliant Z Asia-Pacific Headquarters Tel: +65 6 41 6 4283 Europe, Middle-East and Africa Headquarters Tyco Electronics (UK) Ltd Europe, Tel: M+44 iddle-east (0) 1344 469 and 300, Afric Fax: a +44 He adquarters (0) 1344 469 301 World Wide Headquarters Tel: +49 89 6089 286 Central America-Latin America Headquarters Lineage Power Corporation World Wide Headquarters Tyco Electronics Power Systems 3000 Skyline Drive, Mesquite, TX 75149, USA Tyco Electronics Power Systems, Inc. Tel: +54 11 4316 2866, Fax: +54 11 4312 9508 +1-800-526-7819 India Headquarters (Outside 3000 Skyline U.S.A.: Drive, +1- Mesquite, 97 2-2 84 TX -2626) 75149, USA Tel: +91 Asia-Pacific 8 0 28411633 Headquarters +1-800-526-7819 FAX: +1-888-315-5182 www.line agepower.com Tyco Electronics Singapore Pte Ltd (Outside U.S.A.: +1-972-284-2626, FAX: +1-972-284-2900) e-m www.power.tycoelectronics.com ail: techsupport1@lineagepower.com Tel: +65 482 0311, Fax: 65 480 9299 e-mail: techsupport1@tycoelectronics.com Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or Tyco application. Electronics No Corporation rights under reserves any patent the right accompany to make changes the sale to of the any product(s) such product(s) or information information. contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved. 2001 Tyco Electronics Power Systems, Inc. (Mesquite, Texas) All International Rights Reserved. Printed in U.S.A. Document No:DS03-090 ver. 1.2 PDF Name:jpw200s52r5-bh.pdf