Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

Similar documents
DEPARTMENT OF INFORMATION ENGINEERING. Test No. 1. Introduction to Scope Measurements. 1. Correction. Term Correction. Term...

Test No. 2. Advanced Scope Measurements. History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 2

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 3 The Oscilloscope

Oscilloscope Measurements

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Pre-Lab. Introduction

EK307 Passive Filters and Steady State Frequency Response

Oscilloscope and Function Generators

B. Equipment. Advanced Lab

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Department of Electrical and Computer Engineering. Laboratory Experiment 1. Function Generator and Oscilloscope

DEPARTMENT OF ELECTRICAL ENGINEERING. Date: Assistant A2: PSpice 2 PC Pool

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

EENG-201 Experiment # 4: Function Generator, Oscilloscope

2 AC and RMS. To pass this lab you must solve tasks 1-2. Tasks 3 and 4 are included in the grading of the course.

ENG 100 Lab #2 Passive First-Order Filter Circuits

Laboratory Exercise 6 THE OSCILLOSCOPE

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

DIGITAL STORAGE OSCILLOSCOPES

Laboratory 3 (drawn from lab text by Alciatore)

Notes on Experiment #1

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

Sonoma State University Department of Engineering Science Spring 2017

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

FYSP1110/K1 (FYSP110/K1) USE OF AN OSCILLOSCOPE

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation

CHAPTER 6. Motor Driver

Oscilloscope. 1 Introduction

Introduction to basic laboratory instruments

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

PHY152 Experiment 4: Oscillations in the RC-Circuits (Measurements with an oscilloscope)

THE CATHODE RAY OSCILLOSCOPE

Faculty of Engineering, Thammasat University

EK307 Active Filters and Steady State Frequency Response

Power Supply Rejection Ratio Measurement

Lab 2: Capacitors. Integrator and Differentiator Circuits

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

Experiment 9 The Oscilloscope and Function Generator

Lab 0: Introduction to basic laboratory instruments. Revised by Dan Hoang & Tai-Chang Chen 03/30/2009

ENGR 210 Lab 6 Use of the Function Generator & Oscilloscope

Experiment 8 Frequency Response

Experiment 5 The Oscilloscope

Introduction to basic laboratory instruments

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

1. Hand Calculations (in a manner suitable for submission) For the circuit in Fig. 1 with f = 7.2 khz and a source vin () t 1.

EE EXPERIMENT 8 CAPACITOR CURRENT-VOLTAGE RELATIONSHIP INTRODUCTION

Week 7: Design a Logarithmic Voltmeter. A variation on Experiment 19 Validation by 8pm on October 14

Elizabethtown College Department of Physics and Engineering PHY104. Lab # 9- Oscilloscope and RC Circuit

Sirindhorn International Institute of Technology Thammasat University at Rangsit

EE ELECTRICAL ENGINEERING AND INSTRUMENTATION

EE 241 Experiment #7: NETWORK THEOREMS, LINEARITY, AND THE RESPONSE OF 1 ST ORDER RC CIRCUITS 1

Introduction to Basic Laboratory Instruments

Combinational logic: Breadboard adders

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

INTRODUCTION TO ENGINEERING AND LABORATORY EXPERIENCE Spring, 2015

Waveform Generators and Oscilloscopes. Lab 6

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

LAB 1: Familiarity with Laboratory Equipment (_/10)

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

Spectrum analyzer for frequency bands of 8-12, and MHz

Experiment 1: Instrument Familiarization (8/28/06)

EXPERIMENT 2 DIGITAL STORAGE OSCILLOSCOPE

Laboratory 4. Bandwidth, Filters, and Diodes

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

Experiment 1: Instrument Familiarization

Physics 323. Experiment # 1 - Oscilloscope and Breadboard

Lab 2: Linear and Nonlinear Circuit Elements and Networks

Lab E5: Filters and Complex Impedance

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment:

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

DEPARTMENT OF ELECTRICAL ENGINEERING LAB WORK EE301 ELECTRONIC CIRCUITS

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

2 : AC signals, the signal generator and the Oscilloscope

Fig. 1. NI Elvis System

3.2 Measuring Frequency Response Of Low-Pass Filter :

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

LAB INSTRUMENTATION. RC CIRCUITS.

Transmit filter designs for ADSL modems

ME 365 EXPERIMENT 7 SIGNAL CONDITIONING AND LOADING

Electronics I. laboratory measurement guide

Low_Pass_Filter_1st_Order -- Overview

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

H represents the value of the transfer function (frequency response) at

ECE 480: SENIOR DESIGN LABORATORY

2 Oscilloscope Familiarization

LAB 7: THE OSCILLOSCOPE

Filters And Waveform Shaping

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

SAMPLE: EXPERIMENT 2 Series RLC Circuit / Bode Plot

PHYS 3322 Modern Laboratory Methods I AC R, RC, and RL Circuits

electrical noise and interference, environmental changes, instrument resolution, or uncertainties in the measurement process itself.

ECE 2201 PRELAB 6 BJT COMMON EMITTER (CE) AMPLIFIER

Transcription:

University of Applied Sciences Hamburg Group No : DEPARTMENT OF INFORMATION ENGINEERING Laboratory for Instrumentation and Measurement L: in charge of the report Test No. Date: Assistant A2: Professor: Assistant A3: Report History Introduction to Scope Measurements Date Remarks received Report checked result o.k. n.g.. Correction Term... Date Remarks. Correction received checked result o.k. n.g. 2. Correction Term... Last chance!! Date Remarks 2. Correction received checked result o.k. n.g. not passed back to L... Final decision: o.k. not passed Prof.... EEL2Lab - - Lehmann 07.04.207

Important no wiring before the presentation of a correct circuit diagram including all instruments maintain a log-book to document your experimental work Objectives Basic knowledge of the principles and operating of an oscilloscope Correct measuring of periodic signals: period, frequency, amplitude Bode plots for RC filters Non-sinusoidal signals (triangle and square wave) Preparation Note: This homework is to be prepared prior to the lab session and to be presented at the beginning of the lab session.. Determine the effective value, the mean value, and the rectified value of a sine wave, a square wave and a triangle wave with a peak-to peak-value of U PP = 6.0 V and no DC offset and put these values into a table. 2. Calculate the voltage ratio F(f) = U c /U 0 of a low pass filter with R = 2.2 kω and a capacitance C = 47 nf in the frequency-range from 00 Hz to 0 khz and plot a Bode-plot of F(f). Determine the cutoff frequency f c. 3. Read this information carefully: Last EE lecture Operating a Scope Appendix : Digital Storage Oscilloscope Appendix 2: Subsystems in a scope Appendix 3: Time base and triggering Remember: Use grid paper in the lab to make plots, circuit diagrams and calculations. Use logarithmic paper for Bode plots. Make a plot of the wiring diagram including all necessary instruments and a list of all important items in use. EEL2Lab - 2 - Lehmann 07.04.207

Experiment : Voltage Measurement Measurement setup SG : Signal generator VM: Digital voltmeter (8S) DSO: Digital storage oscilloscope Signal generator setup: Frequency f 0 = 800 Hz, Voltage u pp = 6.0 V (peak to peak) DSO setup: Triggering on channel : DC, +0V SG VM CH DSO Experiment : Time measurement and adjustment of frequencies with a scope a) Generate a sinusoidal signal with a peak to peak voltage u PP and the frequency f 0 given above and display this signal on the oscilloscope. b) Check the voltage with a digital voltmeter (VM type 8S) and adjust the settings of the signal generator so that the voltmeter displays the effective value U 0 = 2.2 V. Experiment 2: Non-sinusoidal signals a) Generate a sine wave, triangle wave and square wave with a peak to peak voltage given above. Display these signals and take a screen shot. b) Measure the RMS and mean values of all signals with the digital voltmeter and the Measure function of the scope and compare the results of the scope, the voltmeter and your pre-calculation. c) Set the function generator to square wave, 6 Vpp with a DC offset of 3V such that the signal changes between 0V and 6V. Measure the True RMS, RMS and mean value and compare them to the theoretical value. EEL2Lab - 3 - Lehmann 07.04.207

Experiment 3: 2-channel-mode and RC low-pass filter SG u VM R S C u c CH CH2 DSO R = 2.2 kω, C = 47 nf f 0 = 500 Hz (f 0 f c ) 3. Filter response of sine wave a) Closing the switch S activates the low-pass filter. Display each channel separately first and then both simultaneously by the scope. (Attention: select DC-coupling in the channel menu.) Assure that the zero-line of both signals is in the centre of the screen. b) Set the frequency to f 0 and measure the time delay between both signals [CH: u(t)=3.0 V sin(ωt), CH2: u c (t) ] using the menus Cursor and the menu Measure. Calculate the phase angle for the given frequency and compare the results with the theoretical value of the pre-calculated Bode plot. c) Determine the peak-to-peak voltage u c and the phase angle between u and u c for the following frequencies: f = f 0 /5, f 0 /2, 2f 0, 5f 0. Make a Bode plot of u c (f) in db and ϕ (f) on half-logarithmic paper. Determine the cutoff frequency graphically and compare it with the pre-calculated theoretical value f c. 3.2 Filter response of triangle and square wave Generate a triangle wave and a square wave with u pp = 6.0 V and f =.0 khz. Make a screen shot of both the original signal u(t) and the filtered signal u c (t). Try to explain why the wave form of the signal output is different from the signal input. EEL2Lab - 4 - Lehmann 07.04.207

Appendix 304B y-channel settings. sensitivity V/div 2. select channels cursor. select trace Digital Storage Oscilloscope Tektronix TDS time base. sensitivity 2 menu trigger menu AC/DC coupling etc EEL2Lab - 5 - Lehmann 07.04.207

Appendix 2: Subsystems in a scope Input Coupling Input Attenuator Pre- Amplifier Main- Amplifier CRT Input Coupling Y- amplifier Y-Plates Vertical deflection system Almost all amplifiers used in scopes are calibrated in terms of sensitivity rather than gain. The actual attenuation or amplification is not important. For special purposes and to give the scope more flexibility in the display of certain types of input signals an input coupling selector is provided for each channel: Input coupling in a scope D C Inp u t co u plin g sw itc h A C G N D R E In the DC-position (which is the most common one), the input signal goes straight to the vertical amplifier. In the AC-position, a capacitor C blocks all dc and very-low-frequency signal components of the signal into the vertical amplifier. If for example an input signal consists of a DC component. U DC, super-imposed onto an ac signal u ac : u(t) = U DC + U AC and only the AC component is of interest, then the AC-position is selected. Warning! The blocked DC signals are not the only ones blocked. The input impedance [R E = MΩ] forms a high pass filter with the capacitor C. The cut-off frequency is approx. 2-0 Hz depending on the value of C. EEL2Lab - 6 - Lehmann 07.04.207

The GND-position of the input coupling switch grounds the internal circuitry of the amplifier. This is used to position the beam on the screen without having to remove the scope lead. Other subsystems in a scope: ) Dual trace features It is often advantageous to be able to display two or more signals simultaneously on the screen. This can be accomplished by electronic switching of the input signals to produce separates traces. There are two possible modes: the ALTERNATE mode, and the CHOPPED mode. Circuit to be tested Probe head Probe tip Coaxial cable To scope input terminals A and B 2) Oscilloscope probes Oscilloscope probes should perform the simple task of sensing signals at their source and transferring them to the input of a scope without loading or disturbing the circuit under test. The simplest types of probes could be simply lengths of wire. However, this type of probe is usually unsuitable because they pick up unwanted noise which is transferred to the scope input. A common probe is a passive voltage probe with no attenuation which consists of a co-axial cable. This type is capable of transmitting high frequency signals without distortion and external interference. Basically oscilloscope measure voltages between the scopes input and ground and thus they can load the circuits to which they are connected. The typical input impedance of a scope is R E =.0 MΩ. EEL2Lab - 7 - Lehmann 07.04.207

Appendix 3: Time-base and Triggering system 5 4 3 Saw-tooth-signal in an CRO The most common use of the scope is to display a signal against time (Y-t mode). Voltage at the X-plate 2 0 - -2-3 -4-5 0 5 0 5 20 25 30 35 time t To generate this type of display, a ramp voltage that causes a linear deflection of the beam must be applied to the X-plates. Additionally this voltage has to be repetitively applied to the horizontal plates and it must be synchronised with the periodic signal being displayed, such that a steady image appears on the screen. This is the function of the time-base circuit which produces a sweep waveform (saw-tooth) starting at t o. In practice, the left edge of the screen corresponds to a negative voltage U smin and the right edge of the screen corresponds to a maximum saw-tooth of U smax, so that the middle line of the display corresponds to a sweep level of zero Volts. EEL2Lab - 8 - Lehmann 07.04.207

EEL No WS 07/08 Triggering level U LEV and slope in a DSO signal uy(t), * trigger level Ulev 3 2 0 - -2 <----------Trigger-Level Ulev *-----------> <---------Trigger-pulses----------------> The TIME/DIV control on the front panel of the scope determines how much time it takes for the sweep waveform to move the spot one division. During the short time required for the spot to be returned from the right edge of the screen to the starting position, the beam has to be shut off (retrace blanking). This is achieved by additional circuitry manipulating the beam intensity. -3 0 0.2 0.4 0.6 0.8.2.4.6.8 2 time-base To achieve a stable display for the sweeped waveform it is necessary to start at the same point of the signal waveform. This is achieved by the triggering signal. Each time a triggering signal meets a pre-selected SLOPE or a voltage LEVEL (U LEV ) condition, the pulse generator emits a pulse to start the sweep generator. The point on the triggering signal at which the pulse generator emits a pulse is controlled by the Trigger Slope and Trigger Level switches on the scope. The trigger slope switch allows to choose whether the slope of the triggering signal should be positive or negative when the pulse generator emits a pulse. Similarly the trigger level switch determines the value (sign and magnitude) of the triggering voltage at which a pulse is generated. When a sweep is triggered an LED is lit on the front panel. For different applications different trigger couplings are requested. EEL2Lab - 9 - Lehmann 07.04.207