Q-SERIES Power. BAQ-UP (QRED) Redundancy Switch with Backup Amplifier INSTALLATION & OPERATION MANUAL.

Similar documents
Q-SERIES. Amplifiers. QPAIR Redundancy Switch Amplifier System. Installation & Operation Manual

MNRS Redundant RF Detector/Switch Module

D3.1/CCAP Compliant HFC. Enhance. C-Cor HECE1G 1GHz Line Extender (with AGC) INSTALLATION & OPERATION MANUAL.

Q-SERIES. Optical. QFQR 200A-04 Series Return Path Optical Receiver. Installation & Operation Manual

SignalOn Series. RF Passive Modules INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

D3.1 / CCAP Compliant

Ultra-Dense RF & Optical Active Modules Combiners

SMACSM Frequency Agile Pilot Carrier Redundancy Source

CCAP Compliant. Discontinued

RF Signal Management. RF Signal Management. Active & Passive Products* Passives: Actives:

D3.1 / CCAP Compliant. 1.2 GHz. Make-Before-Break (MBB) Splitter/Combiner Module Specifications

SignalOn Series. Passive Modules Splitter/Combiner Modules. Features. Specifications Make-Before-Break (MBB) Splitter/ Combiner Module. 1.

HFC. Enhance. QFHPN High Power Optical Node with AGC Installation & Operation Guide

D3.1 / CCAP Compliant. 1.2 GHz. SignalOn Series. Forward Path Amplifier Products. Installation & Operation Manual

Chromadigm CHS/CHQ Transmitter

Status Monitoring And Control Solutions. (HMS Compliant, SNMP Based) SMAC SM PCR Pilot Carrier Redundancy Platform. Installation & Operation Manual

SignalOn Series WHITE PAPER. Impact of CCAP on RF Management Isolation. Pat. #s U.S. 6,842,348; 7,043,236; Cdn. 2,404,840; 2,404,844

SignalOn Series. RF Signal Management. Active & Passive Products* Passives: Actives:

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

INSTALLATION MANUAL. CTA-30RK-550 Rack Mount Distribution Amplifier

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

ChromaFlex. ChromaFlex DMT24, DMT34 & DMT44 Multi-Wavelength DWDM Direct Modulated Transmitter Module HARDWARE INTERFACE MANUAL.


GainMaker Node SMC Status Monitor Transponder Installation Instructions

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Prisma II Optical Receivers

GPSS216 Quick Start Guide

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

MODEL AF200A: FM, FM/SCA RECEIVER/MONITOR OPERATION MANUAL

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

DIGICELL ANYNET NETWORK ACCESS MODULE

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

Chromadigm-IR CIR - Integrated RFoG Transmitter

Transponder for GainMaker Optoelectronic Node

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Flexible Receiver. Installation Notes. Product Part No (304MHz)

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

Instructions for programming and use Starline Roldeck - floorpanel control RD-2001

EX Multi-Point Process Switch KING-GAGE ma Process Control. Single-Channel Analog. Start-Up/Operation Instructions.

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

I-HUB Chassis. Hardware Interface Manual

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY

Instruction Manual Model M Switch, DPDT, Manual Select

2006 MFJ ENTERPRISES, INC.

G3L Multi-Carrier Power Amplifier Installation and Service Manual

Model 1791 VHF Radio User's Manual

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Model 7000 Low Noise Differential Preamplifier

Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015

RTC. Redundant Transmitter Controller FM RTC. Redundant Transmitter Controller. User's Manual

BC145 SIGNAL ISOLATOR BOARD

igeacom User Guide V2.0

and GHz. ECE Radiometer. Technical Description and User Manual

Operation and Service Manual. 350 MHz Preamplifier SIM914. Stanford Research Systems

Compact Nodes and 90071

B031 DUAL PILOT TONE DETECTOR

80-MHz Balanced Photoreceivers Model 18X7

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

APPLICATION NOTE LZY-1 ULTRA-LINEAR RF AMPLIFIER. 20 MHz MHz 25 WATTS MIN., 1 db COMPRESSION (50 WATTS TYP., MAX. OUTPUT)

Spectrian 2304 MHz SSPA. Garry C. Hess, K3SIW June 11, 2004

AC3000 INTELLIGENT BROADBAND AMPLIFIER

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD

750 MHz Magnamax series

Continuous Wave Laser Average Power Controller ADN2830

Agilent Technologies 355C, D, E, F VHF Attenuators. Operating and Service Manual

Advanced Test Equipment Rentals ATEC (2832)

Downstream signal path (values with diplex filters) Upstream signal path (values with diplex filters)

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Parameter Symbol Units MIN MAX. RF Input power (CW) Pin dbm +20. DC Current A 1.6

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual

SUPPLIER PHONE FAX WEBSITE TDK Maxim Integrated Products 1

3 T856/857 Initial Tuning & Adjustment

SAPLING WIRELESS SYSTEM

INSTALLATION & OPERATING INSTRUCTIONS

Output Voltage : 0.3 to 25 kv Output Current : 0.1 to 20 ma

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

WARNING! IMPORTANT NOTICE

Full protection IN - OUT

PowerMonitor III. Digital Power and SWR meter for HF bands

Central Electronics Model 600L Linear Amplifier

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Compact Node Optoelectronics

80-MHz Balanced Photoreceivers Model 18X7

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

Ambient Level Controller

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

Ness MCR Multi-Channel Radio Receiver

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

IntelliTuner Automatic Antenna Tuner

Transcription:

D INUE T N O S DI Q-SERIES Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier INSTALLATION & OPERATION MANUAL www.atxnetworks.com www.atxnetworks.com

Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice. SignalOn Series, MAXNET, HF Enhance, PI Filters, Q-Series & FiberLinx are registered trademarks of ATX in the United States and/or other countries. SMA SM is a service mark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-atx product and company names in this manual are the property of their respective companies.

TABLE OF ONTENTS Page 1. DESRIPTION OF INTERFAES... 1-1 2. DESRIPTION OF OPERATION... 2-1 2.1. Functional Schematic... 2-2 3. SET-UP PROEDURE... 3-1 4. SPEIFIATIONS... 4-1 5. SERVIE & SUPPORT... 5-1 5.1. ontact ATX Networks... 5-1 5.2. Warranty Information... 5-1 Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier Installation & Operation Manual i

This page left intentionally blank. ii Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifi er Installation & Operation Manual

HAPTER 1: DESRIPTION OF INTERFAES DESRIPTION OF INTERFAES 1. Description of Interfaces BAQ-UP Front View The BAQ-UP system (the system) has three compartments: the amplifi er compartment, the power supply compartment, and the RF switch compartment. Power Supply ompartment: (Located in the center portion of the chassis) a) Rear: 24 VA Input 24 VD Input b) Front: Green LED: 24V power on Description: Both the 24 VA and the 24 VD can be connected at the same time to their designated terminal strips. A diode OR circuit is located internally to select the source with the highest voltage. This allows you to provide redundant power to this device by simultaneously connecting the 110 VA / 24 VA supplied transformer to the A terminals when you also have connected a 24 VD source to the D terminals. The green LED on the front indicates proper power supply operation. RF Amplifier ompartment: (Right side of chassis facing back) a) Rear: Input (located immediately to the right of the A/D terminal block) Output (located at the extreme right of the chassis) b) Front: (with cover removed): Input Test Point Output Test Point Gain ontrol Slope ontrol Input Pad (used to optimize the input to the amplifi er) Description: This is referred to as the secondary amplifi er because your existing amplifi er is referred to as the primary amplifi er. This internal amplifi er has a low-noise front-end and is comparable in signal quality to any primary amplifi er. RF Switch ompartment: (Left side of chassis facing back) a) Rear: Main Signal Input (located immediately left of A/D terminal block) Output to Primary Amp Output to Secondary Amp Input from Primary Amp Input from Secondary Amp Main Output (on extreme left side facing back of chassis) Description: If you are connecting this amp/switch as a redundant amp for your existing amplifi er, then move the input from your existing amplifi er to the main signal input connector for this device. onnect a cable from the Out to Primary connector to the input of your existing amplifi er. Move the output of your existing amplifi er to the In from Primary connector. onnect a cable from Out to Secondary to the secondary amplifi er input located immediately to the right of the 24 VD / 24 VA terminal connectors. onnect another cable from In from Secondary to the secondary amplifi er output located to the extreme right of the chassis as you are facing the rear of the chassis. Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifi er Installation & Operation Manual 1-1

HAPTER 1: DESRIPTION OF INTERFAES Alarms: Alarm 1 (form ) for the primary amp Alarm 2 (form ) for the secondary amp Switch: Remote control switch contacts Description: The form contacts may be used to switch any warning device that can provide a notification in case either amplifier has failed. The remote switch contacts may be used to force a switch from the primary to the secondary amplifier. b) Front: (with cover removed): Green LED: 5V power on Yellow LED (warning): On: using reference levels stored in EEPROM Flashing (1/sec): Needs to set reference levels Flashing (3/sec): Switched to the secondary amplifier by the remote control switch Red LED (alarm): On: Primary amp failure Flashing (1/sec): Secondary amp failure Flashing (3/sec): Input signal low/primary amp and secondary amp failure RF Detectors: Primary Amp RF Level Detector: D level proportional to the primary amp RF output level Secondary Amp RF Level Detector: D level proportional to the secondary amp RF output level Test Points: Primary Amp D Level Secondary Amp D Level Switches: ontroller Reset: Restarts the microcontroller program Set Ref Levels: Stores the levels as references and start monitoring the amps 1-2 Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier Installation & Operation Manual

HAPTER 2: DESRIPTION OF OPERATION DESRIPTION OF OPERATION 2. Description of Operation RF output levels of both the primary and the secondary amplifiers are sampled and this sample is converted to a voltage value. At initial power on, the system is switched to run on the primary amp. The yellow LED will flash slowly indicating the reference levels need to be set. By pressing the Set Reference Levels switch, the microcontroller samples the output values of both the primary amp and the secondary amp and stores the values as references. These values will be used to compare with the sampled output values of both amplifiers to confirm proper levels. At any time during the operation, one can always press the ontroller Reset switch to reset the microcontroller program and store the new sampled values. The remote control switch is activated by closing the remote control contacts. Activation (closing the contacts) effects a switch to the secondary amplifier. Removing the contact closure will cause a switch back to the primary amplifier. When the system is switched to the secondary amp, the yellow LED will flash quickly to warn the user. The remote control switch can change the system back and forth from the primary amp to the secondary amp by opening/closing the remote control contacts. The system detects the remote control switch periodically to check its state. If a change in status is detected on the remote control switch, the system will set to the primary or secondary amp according to the state of the contact closure. During normal operation, if both outputs are within 3 db (factory programmable) of the reference values, no action will be taken. If the primary amp is down 3 db or more and the secondary amp is not, the system considers the primary amp failed and will switch to the secondary amp, set Alarm 1, and set the red LED on. The system needs to be reset (by the controller reset push buttom on the front of the unit) at this point to get back to normal operation (after correcting the levels of the primary amplifier). If both outputs are down 3 db or more, the system considers the input is low and will set the red LED flashing quickly and set the alarms. The system needs to be reset at this point to get back to normal operation (after correcting the input levels). If the system is running on the primary amp and the secondary amp level is down 3 db or more, the system considers the secondary amp failed and will set Alarm 2 and set the red LED flashing slowly. The system should be reset at this point to get back to normal operation (after making corrections to the secondary amp). If the primary amp has failed and the microcontroller has switched to the secondary amp, the microcontroller can not perform any additional switches because the detectors are unable to sample any signal when the secondary amplifier is activated. The system needs to be reset at this point to get back to normal operation (after correcting the primary amplifier signal level). The remote control switch is non-functional in this situation since a switch can not be forced to a failed primary amplifier. The total power within the bandwidth from the primary amplifier coming into the RF switch compartment should not exceed 50 dbmv per channel. If only a portion of the TV channels is used, the maximum signal level per channel could be higher than 50 dbmv and the minimum signal level should be higher than 20 dbmv. The recommended primary amplifier output level is between 20 dbmv and 50 dbmv with all the TV channels loaded within the passband. The secondary amplifier operates 20 db lower than the primary amplifier during normal operation. The system also stores the reference levels to the EEPROM on the microcontroller. When a power outage occurs, the system can retrieve the reference levels from the EEPROM after the power comes back on. After power on, the system waits for three minutes for the user to press the Set Reference Levels switch and will retrieve the levels from EEPROM if the switch is not pressed. The system will also warn the user with a steady yellow LED light when it s using the retrieved reference levels. The user can press ontroller Reset switch and then press the Set Reference Levels switch to overwrite the retrieved levels. Please notice that when the user first gets the system, there are reference levels stored into the EEPROM while the system was tested in the factory. During normal operation, Alarm 1 and Alarm 2 are energized (i.e. the Normally Open contact is connected to the ommon contact). This configuration ensures that the user be alerted when power goes down. Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier Installation & Operation Manual 2-1

HAPTER 2: DESRIPTION OF OPERATION 2.1 Functional Schematic PRIMARY (MAIN) AMP SEONDARY (BAKUP) REEIVER PRIMARY (MAIN) REEIVER SIGNAL IN OUT TO PRIMARY IN FROM PRIMARY OUT TO PRIMARY IN FROM PRIMARY INPUT N NO DETETOR INPUT N NO DETETOR NO N NO N NO N DETETOR OUTPUT SIGNAL OUT NO N NO N NO N DETETOR OUTPUT SIGNAL OUT OUT TO SEONDARY JUMPER IN FROM SEONDARY OUT TO SEONDARY IN FROM SEONDARY SEONDARY (BAKUP) AMP This wiring configuration is for a hub site with a primary input and a backup input. In addition to the wiring method, the microprocessor is programmed at ATX to switch to the secondary input when the primary input falls below the threshhold level. When the primary level is restored within normal range, the QRED will switch back to the primary input immediately. This is an advantage in unmanned hub sites in that no level resetting is required after a primary path failure. This wiring configuration is for a headend site with an amplifier that needs backup protection. This typically is used in the signal path where an amplifier failure is not acceptable. The QRED switch is programmed to switch to the secondary amplifier when the cumulative RF output of the primary amplifier falls below a programmed level, usually a 3 db drop. This output is measured within a frequency range from 120-220 MHz. The microprocessor controlled switch can be programmed to switch within the end users specifications for timing and RF levels. Once a switch is made to the secondary amplifier, the signal path continues through the secondary amplifier until a technician restores the primary amplifier signal levels and resets the switch manually. 2-2 Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier Installation & Operation Manual

HAPTER 3: SET-UP PROEDURE SET-UP PROEDURE 3. Set-up Procedure 1. Remove the cover. 2. onnect input signal to the Input of the RF switch compartment. 3. onnect the Output to Secondary Amp of the RF switch compartment to the Input of the amplifier compartment. 4. onnect the Output of the amplifier compartment to the Input from Secondary Amp of the RF switch compartment. 5. onnect the Output to Primary Amp of the RF switch compartment to the Input of an external amplifier. 6. onnect the Output of the external amplifier to the Input from Primary Amp of the RF switch compartment. 7. onnect signal strength meter to the Output of the RF switch compartment. 8. Adjust the external amplifier to get the desired level. 9. onnect 24 VD or 24 VA to the appropriate input of the power supply compartment. 10. Push the Set Ref. Levels switch. 11. onnect the + and - contact of the remote switch with a jumper to force the microcontroller switch to the secondary amplifier. 12. Adjust the gain and slope control in the amplifier compartment to get desired signal level. 13. Remove the jumper from the remote switch. 14. Remove the signal strength meter from the Output of the RF switch compartment. 15. onnect the Output of the RF switch compartment to the desired output cable. 16. Use a voltmeter to measure the D voltage on the Secondary Amp D Level test point. Adjust the variable attenuator on the secondary amp level detector to get the voltage to a nominal 2.5V if possible. (For lower RF levels, the detected D voltage may not reach 2.5 VD. This is normal). 17. Use the voltmeter to measure the D voltage on the Primary Amp D Level test point. Adjust the variable attenuator on the primary amp level detector to get the voltage close to the voltage on the Secondary Amp D Level test point. 18. Put the cover back on. 19. Press ontroller Reset. 20. Press Set Ref Levels. SET UP PROEDURE IS OMPLETE Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier Installation & Operation Manual 3-1

HAPTER 3: SET-UP PROEDURE This page left intentionally blank. 3-2 Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifi er Installation & Operation Manual

HAPTER 4: SPEIFIATIONS SPEIFIATIONS 4. Specifications Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier Installation & Operation Manual 4-1

HAPTER 4: SPEIFIATIONS This page left intentionally blank. 4-2 Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifi er Installation & Operation Manual

HAPTER 5: SERVIE & SUPPORT SERVIE & SUPPORT 5. Service & Support 5.1 ontact ATX Networks Please contact ATX Technical Support for assistance with any ATX products. Please contact ATX ustomer Service to obtain a valid RMA number for any ATX products that require service and are in or out-of-warranty before returning a failed module to the factory. RF Products (MAXNET, SignalOn, HF Enhance, PI Filters, Q-Series, SN, SMA, FiberLinx) TEHNIAL SUPPORT Tel: (905) 428-6068 press *3 then press 2 Toll Free: (800) 565-7488 press *3 then press 2 (USA & anada only) Email: rfsupport@atxnetworks.com USTOMER SERVIE ATX Networks 1-501 lements Road West Ajax, ON L1S 7H4 anada Tel: (905) 428-6068 press *1 Toll Free: (800) 565-7488 press *1 (USA & anada only) Fax: (905) 427-1964 Toll Free Fax: (866) 427-1964 (USA & anada only) Email: support@atxnetworks.com Web: www.atxnetworks.com 5.2 Warranty Information All of ATX Networks products have a 1-year warranty that covers manufacturer s defects or failures. Q-Series Power BAQ-UP (QRED) Redundancy Switch with Backup Amplifier Installation & Operation Manual 5-1

ISO 9001:15 REGISTERED 2018 ATX Networks Printed in anada Information in this document is subject to change without notice. Rev. 07/18 (ANW0849) ATX Networks 1-501 lements Road West, Ajax, ON L1S 7H4 anada Tel: 905.428.6068 Toll Free: 800.565.7488 support@atxnetworks.com www.atxnetworks.com