Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Similar documents
Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

DDM350 Pen-Type Digital Multimeter User s Manual

DCM730. Digital Clamp Meter User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Dawson DSM150. Digital Light Meter User s Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

NOTE: Fully read and understand this manual before using this Digital Multimeter.

MS2109A AC/DC Clamp Meter. User Manual. Contents

AC/DC CLAMP METER USER S MANUAL

MS8223A. CAT.IIi 600 V

User Manual. All rights reserved. Specifications are subject to change without notice.

User Manual Digital Multimeter. model no.: MSR-U1000

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DIGITAL MULTIMETER AUTORANGING

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

User Manual. All rights reserved. Specifications are subject to change without notice.

True RMS Digital Multimeter Model:

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

CONTENTS MS2033A. 1.Introduction Safety Information...01

User Manual Digital Multimeter

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

MODEL: D03128 CLAMP METER

Digital Clamp Meter Model: &

200Amp AC Clamp Meter + NCV Model MA250

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Pen Multimeter. Model

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Digital Multimeter, Pen Type

312, 316, 318. Clamp Meter. Users Manual

User Guide. Digital AC/DC Clamp Meter Model 38394

UT207A/208A/209A Operating Manual. Table of Contents

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

User s Guide. Digital AC/DC Clamp Meter Model 38394

AMM-1022 Digital Multimeter USER`S MANUAL

Table of Contents GDM-356. Page

1.General instructions Specifications Description...7

DIGITAL MULTIMETER INSTRUCTION MANUAL

Autoranging Multimeter Extech EX503

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

KMD-S04 Multímetro de bolsillo

AM-540 AM-550. AM-540-EUR AM-550-EUR Digital Multimeter. Users Manual. Advanced HVAC Multimeter. Industrial Multimeter

AC750 DIGITAL CLAMP METER

User s Guide. 400A AC/DC Clamp Meter. Model MA220

ProfiScale MULTI Multimeter

Multifunction Digital

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

User Manual Digital Clamp Multimeter. model no.: MSR-C600

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

DIGITAL CLAMP METER Use s Manual

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

OPERATOR S INSTRUCTION MANUAL

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

Model : OPERATING MANUAL Table of Contents (1)

Table of Contents Title Page

Handheld Digital Multimeter PRO-50A

770E DIGITAL MULTIMETER OPERATOR S MANUAL

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

OPERATING INSTRUCTIONS

DVM1190 DIGITAL MULTIMETER

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

15B & 17B. Users Manual. Multimeters

DMM8900 SERIES USERS MANUAL

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

400Amp True RMS AC/DC Clamp Meter Model EX613

VC835 DIGTAL MULTIMETER Operation Manual

Handheld Digital Multimeter

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Pen Multimeter. Model

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

MS2030 CAT III 600 V A V AUTO RS232

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Model UT10A: OPERATING MANUAL Table of Contents (1)

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Sales: Technical: Fax:

User s Guide. Model MA A AC Mini Clamp-on Meter

Analog Technologies. Multimeter 15B and17b

Model DIGITAL MULTIMETER

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Handheld Digital Multimeter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

USER'S MANUAL DMR-6700

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Instruction Manual IDM 66RT Digital Multimeter

OPERATING INSTRUCTIONS

netzerotools.com 374/375/376 Users Manual Clamp Meter

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

Title Page Overview Unpacking Inspection Safety Information

AX-C Introduction. 2. Safety Information

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

Transcription:

Dawson DDM230C True RMS Multimeter with Bar Graph Display User s Manual

Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 4 Certification... 8 INTRODUCTION... 8 Overview... 8 Components and Buttons... 9 Components... 9 Buttons and Symbols... 10 LCD Display... 11 USING THE METER... 12 Display Hold... 12 Switch between Modes... 12 Relative Measurement... 13 Max/Min Measurement... 13 1

Switch between Functions... 14 Backlight... 14 Auto Off... 14 NCV (Non-Contact Voltage Detector)... 14 DC and AC Voltage Measurement... 15 Resistance... 16 Continuity... 16 Diode... 16 Capacitance... 17 Frequency and Duty Ratio... 17 Current... 17 SPECIFICATIONS... 18 General Specifications... 18 Technical Specifications... 19 MAINTENANCE AND REPAIR... 26 Battery Replacement... 26 Test Leads Replacement... 27 CONTACT DAWSON... 27 FEATURES... Back Page 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY This instrument from Dawson Tools Inc. will be free from defects in workmanship and material for three years from the date of original purchase. This warranty does not cover defects resulting from damage caused by the user such as drops, neglect, misuse, unauthorized alteration, usage outside of specified conditions, contamination, or improper repair/maintenance. To receive service on the instrument if it becomes necessary during the warranty period, contact your nearest Dawson authorized service center at (800) 898-6991 or visit www.dawsontools.com to obtain a return authorization (within the US only). A return authorization is necessary before returning any instrument to Dawson; no service will be provided without a return authorization. The user is responsible for properly packing the unit and charges such as shipping, freight and insurance charges. The extent of Dawson's liability is limited solely to the repair/replacement of the instrument. The above warranty in its entirety is inclusive and no other warranties, written or oral, are expressed or implied. Out of the Box Check the Meter and accessories thoroughly before using the Meter. Contact your local distributor if the Meter or any components are damaged or malfunction. 3

Accessories Test Leads 1 pair 9V 6F22 Battery 1pc User s Manual Safety Information WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, PRODUCT DAMAGE OR PERSONAL INJURY, PLEASE FOLLOW THE SAFETY INSTRUCTIONS DESCRIBED IN THE USER MANUAL. READ THE USER MANUALS BEFORE USING THE METER. WARNING TO ENSURE SAFE OPERATION AND LIFE OF THE METER, DO NOT PLACE THE METER IN ANY ENVIRONMENT WITH HIGH PRESSURE, HIGH TEMPERATURE, DUST, EXPLOSIVE GAS OR VAPOR. 4

5 Avoid shaking, dropping or any kind of impacts when using or transporting the Meter. To avoid electric shock or personal injury, repairs or servicing not covered in this manual should be performed only by qualified personnel. Avoid direct exposure to sunlight to ensure extended life of the Meter. Do not place Meter in a strong magnetic field; this may cause false readings. Use only the batteries indicated in the Technical Spec. Avoid exposing batteries to humidity. Replace batteries as soon as the low battery indicator appears. Please keep the original packing for future shipping purposes (ex. Calibration) After opening the box, check for any damage during delivery. Check the terminals every time before operating the Meter. Do not operate the Meter if the terminals are damaged or one or more functions are not working properly.

Check the test leads before operation. Leads must be in good condition; check if leads are well covered by insulator, and if wires are not exposed. Use the original test leads included in the package for best performance and safety. If necessary, use the compatible leads with same specifications of the originals. Safety Symbols on the Meter Important safety information, please refers to the user manual Earth ground Indicates compliance with requirements for double insulation Important Safety Information Never use the Meter to measure voltages that might exceed 600V DC/AC above earth ground. In Manual Mode, if the circuit value is unknown, start the Meter at the maximum range and then adjust accordingly. 6

Always be careful when working with voltages above 60V DC or 30V AC RMS. Keep fingers behind the probe barriers while measuring. Never connect the Meter leads across a voltage source while the rotary switch is in the resistance, diode or continuity mode. Doing so can damage the Meter. Inspect test leads and probes for cracks, breaks or crazes on the insulation before using the Meter. Remove the leads from the circuit first before switching between functions. Do not power on the circuit when measuring resistance, capacitance or diodes. Do not measure the capacitance before the capacitors are discharged. Do not operate the Meter near explosive gas, vapor or under dust. Stop the operation if the Meter or test leads appeared damaged or do not function properly. Unless the battery cover and the Meter case are firmly closed, do not use the Meter. 7

Repair or maintenance should be implemented by trained personnel. Certification CAT IV: This meter has meet IEC1010-1 standard with an overvoltage category (600V CAT IV) and pollution degree 2. The Meter is compiled to EMC requirements. Introduction Overview Dawson DDM230C is a portable, hand-held yet professional meter that features True RMS measurement display, AC/DC current, AC/DC voltage, Frequency, Capacitance, Resistance, Continuity, Duty Ratio, and Diode Testing. This Meter is easy to use even with one hand, suitable for professional users or amateurs, and ideal for school or home use. 8

Components and Buttons Components 1. NCV LED Indicator 2. LCD Display 3. Buttons 4. Function Rotary Switch 5. Input 6. Voltage Sensing Area. 9

Buttons and Symbols HOLD button: to hold the reading. FUNC button: to switch between functions. RANGE button: to set the range for manual or auto measurement. REL button: for relative measurement. Hz/% button: to switch between Frequency and Duty Ratio. MAX/MIN button: to switch between Maximum and Minimum measurement. Symbols: OFF: power off. : Input terminal for Resistance, Capacitance, Voltage, Frequency, Diodes and Continuity. μa, ma: μa and ma input. 10A : 600mA to 10A current input COM: Common Input Terminals. : Backlight light ON/OFF. 10

LCD Display 11 AC DC AUTO MAX MIN REL H Alternating Current Direct Current, Diode, Continuity Auto Mode Maximum Measurement Displayed Minimum Measurement Displayed Relative Measurement Mode Auto Power Off Battery Low Display Hold

% Percentage(Duty Ratio) mv, V A nf,μf, mf MilliVolt, Volt(Voltage) Amp(Current) Nanofarads, Microfarads, Millifarads Ω, kω, MΩ Ohms, Kilohms, Megaohms Hz, khz, MHz NCV Hertz, Kilohertz, Megahertz Non-Contact Voltage USB Mode Using the Meter Display Hold During measurement, press HOLD button to hold the current reading on the display. Press HOLD again to unlock the reading. Switch between Modes When using the rotary switch to switch between current, voltage, capacitance and frequency mode, the default range type is Auto. Press RANGE button to enter Manual mode. Each press increases the 12

measuring range and will return to minimum range after maximum has been reached. Hold RANGE for 1 second to switch back to Auto mode. If the Meter in in Max/Min mode. Press RANGE to return to Normal mode. Note: Manual mode is not allowed in frequency measurement. Relative Measurement Press REL button to enter Relative Measurement Mode. Reading = (current measurement measurement when REL is pressed) Max/Min Measurement To Find Max/Min of the measurement, in any mode, press MAX/MIN to enter Maximum measurement and press again to enter Minimum measurement. Holding the button will go back to normal measurement and the Max/Min readings will be recorded. 13

Switch between Functions During Voltage or Current measuring, press FUNC button to switch between AC and DC measurements. When measuring Resistance, Diode or Continuity, press FUNC will switch between these modes. Backlight Press to turn on/off the display backlight. Auto Off If the Meter is not in use for 30 minutes, the Meter turns off automatically to conserve power. Press any button to turn the Meter back on. To disable Auto Off, hold FUNC button when turning on the Meter. NCV (Non-Contact Voltage Detector) Turn the rotary switch to NCV mode, move the top of the Meter close to target. The Voltage sensing indicator will flash and buzz if the Meter senses a voltage greater then 110V AC. 14

WARNING EVEN THOUGH THERE IS NO INDICATION, VOLTAGE MAY STILL EXIST. THE MEASUREMENT MAY BE AFFECTED BY THE DESIGN OF THE OUTLET, TYPE OF INSULATION AND OTHER EXTERNAL FACTORS. NOTE: The voltage sensing indicator may turn on when a voltage is fed to the Meter. Other external interference (ex. Flashlight, motor) may trigger the NCV sensor. DC and AC Voltage Measurement Turn the rotary switch to Mode, connect the black lead to COM and the red lead to V input. Use the two leads to test the target. Measurement is shown on the display. In DC mode, the Meter also displays the polarity of red lead side input. Press FUNC button to switch between DC and AC voltage measuring. 15

NOTE : 660mV range is only accessible in Manual Mode. Resistance Turn the rotary switch to. Connect the black lead to input COM and the red lead to. Use both leads to test the target resistance and read the measurement from the display. Continuity Press FUNC during resistance measurement to switch to continuity test. Connect the black lead to input COM and the red lead to. Use both leads to test the target resistance; the Meter will buzz if the resistance is less than 50 ohms. Diode Press FUNC during continuity test to switch to diode test. Connect the black lead to input COM and the red lead to. Connect red lead to anode (+) and black to cathode (-); the Meter shows forward biased voltage. 16

Capacitance Turn the rotary switch to.connect the black lead to COM and the red lead to. Use both leads to test the target capacitor and read off the capacitance from the meter. Frequency and Duty Ratio Turn the rotary switch to Hz%. Connect the black lead to COM and the red lead to Hz. Use both leads to test the target and read off both values from the Meter. Press Hz% to switch between frequency and duty ratio (%). Current Disconnect the target circuit from power source and discharge the circuit. Turn the rotary switch to appropriate mode (µa, ma or A). Connect the black lead to COM and the red lead to µa ma if the target current is less than 600mA; connect to 10A if the target current is between 600mA to 10A. Break the circuit and connect the leads across the broken circuit (Red to higher voltage, black to the lower). Power the circuit and read the measurement from the display. If the Meter displays OL (overload) switch the rotary switch to a higher range. 17

Specifications General Specifications Full time surge protection. Maximum Voltage range between target and ground: 600V DC or AC. Maximum working height: 2000m. Maximum display number: 6599. Auto Polarity Indication, - indicates negative. Overload Indication: 0L or -0L. Sampling Time: 0.4 seconds. 1 second on current measurement. Units Display: Display functions and units. Auto Power Off: 30 minutes Input Power: 9V DC Battery Type: 6F22 Low Battery Indication: LCD display Working Environment Temp: 32 F~104 F (0 C~40 C) Storage Temperature: 14 F ~122 F (-10 C~50 C) Size: 7 x 3.4 x 2 in (180 86 52mm) Weight: 8.8oz ~(250g) exclude battery 18

Technical Specifications Environmental Temperature: 74 9 F, relative humidity: <75% Features of True RMS For non-sinusoidal signal measurement, the Meter provides more accurate measurement than the traditional averaging method. If in AC current mode, the Meter may display a random reading between 1 and 50 when the input is not active. This will not affect the accuracy of measurement. True RMS requires a minimum input level, AC current or voltage should be 2%~100% of the maximum level. DC Voltage 19 Range Resolution Accuracy 660mV 0.1mV ( 0.8% + 3 Counts ) 6.6V 0.001V 66V 0.01V 600V 0.1V ( 0.5% + 5 Counts ) Input Resistance : 10M Overload Protection: In 660mV Range : 250V DC/AC. In 6.6V to 600V Range : 600V DC/AC

Maximum Input Voltage : 600V DC AC Voltage Range Resolution Accuracy 660mV 0.1mV ( 1.5% + 5 Counts ) 6.6V 0.001V 66V 0.01V ( 1.2% + 5 Counts ) 600V 0.1V ( 1.5% + 5 Counts ) Input Resistance : 10M Overload Protection: In 660mV Range : 250V DC/AC. In 6.6V to 600V Range : 600V DC/AC Maximum Input Voltage : 600V AC (RMS) Frequency : 50~60 Hz Measurement: True RMS 20

Resistance Range Resolution Accuracy 660 0.1 6.6k 0.001k 66k 0.01k ( 0.8% + 5 Counts) 660k 0.1k 6.6M 0.001Mk 66M 0.1M ( 1.5% + 5 Counts ) Open Circuit Voltage : ~0.4V Overload Protection : 250V DC/AC (RMS) Diode Resolution 0.001V Forward Biased Current : ~1mA Function Displays approx. forward biased voltage Reversed Biased Voltage : ~3.3V Overload Protection : 250V DC/AC (RMS) 21

Capacitance Range Resolution Accuracy 6.6nF 0.001nF ( 4% + 5 Counts ) 66nF 0.01nF 660nF 0.1nF 6.6 F 0.01 F ( 5% + 3 Counts ) 66 F 0.01 F 660 F 0.1 F 6.6mF 0.001mF ( 4% + 5 Counts ) 66mF 0.01mF Overload Protection : 250V DC/AC (RMS) Continuity 22 Resolution 0. 1 Function The Meter buzz when the target resistance is smaller then 30 Open Circuit Voltage : ~1.2V Overload Protection : 250V DC/AC (RMS)

Frequency Through V or Current Mode Range Resolution Accuracy 66Hz 660Hz 6.6kHz 10kHz 0.01Hz 0.1Hz 0.001kHz 0.01kHz Range : 10Hz ~ 10kHz ( 1.5% + 5 Counts ) Input Voltage : 0.2V AC (Input voltage should increase along with the frequency) Through Hz Mode 23 Range Resolution Accuracy 66Hz 660Hz 6.6kHz 66kHz 660kHz 6.6MHz 66MHz 0.01Hz 0.1Hz 0.001kHz 0.01kHz 0.1kHz 1kHz 10kHz Input Voltage : 3V peak to peak AC Overload Protection : 250V DC/AC (RMS) ( 1.5% + 5 Counts )

Duty Ratio Range Resolution Accuracy 10-95% 0.1% 2.0% Open Circuit Voltage : 1.2V Overload Protection : 250V DC/AC (RMS) DC Current Range Resolution Accuracy 660 A 6600 A 66mA 660mA 0.1 A 1 A 10 A 100 A ( 1.0% + 5 Counts ) 10A 10mA ( 2.0 % + 5 Counts ) Overload Protection: In A and ma range, Fuse: FF600mA/1000V. In A Mode: Fuse: FF10A/500V. When the target current is larger than 5A, do not continue the measurement for more than 10 seconds. Pause for 1 minute after measuring. 24

AC Current Range Resolution Accuracy 660 A 6600 A 66mA 660mA 0.1 A 1 A 10 A 100 A ( 1.5% + 5 Counts ) 10A 10mA ( 3.0% + 5 Counts ) Overload Protection: In A and ma range, Fuse: FF600mA/1000V. In A Mode: Fuse: FF10A/500V. When the target current is larger than 5A, do not continue the measurement for more than 10 sec. Pause for 1 minute after the measuring. Frequency : 50~60 Hz Measurement: True RMS 25

Maintenance and Repair Battery Replacement WARNING TO AVOID ELECTRICAL SHOCK, PRODUCT DAMAGE OR PERSONAL INJURY, REMOVE TEST LEADS BEFORE OPENNING BATTERY COVER. Replace batteries when the battery indicator is on. Remove the battery cover and replace a new battery. 26

Test Leads Replacement WARNING REPLACE TEST LEADS WITH IDENTICAL OR COMPATIBLE LEADS. LEAD SPEC:1000V 10A. Replace new leads if the current leads worn. Contact Dawson Dawson Tools, Inc. 1142 S. Diamond Bar Blvd., #858 Diamond Bar, CA 91765 Phone: (310) 728-6220 www.dawsontools.com Do not recycle 27

(Back Page) Features LCD Display Auto Ranging Relative Measurement Non-Contact Voltage Detector True RMS Diode Test Continuity Buzzer MAX/MIN Display Data Hold Auto Power Off Low Battery Back Light 28