Exercises on overhead power lines (and underground cables)

Similar documents
Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

In Class Examples (ICE)

Lab 1. Objectives. Single Line Diagram. Methodology. Observations. Jon Jawnsy Yu 26 October 2009

EE 740 Transmission Lines

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

EE 340 Transmission Lines. Spring 2012

EE 340 Transmission Lines

Transmission Line Models Part 1

6.014 Lecture 14: Microwave Communications and Radar

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian institute of Technology, Kharagpur

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

BE Semester- VI (Electrical Engineering) Question Bank (E 605 ELECTRICAL POWER SYSTEM - II) Y - Y transformer : 300 MVA, 33Y / 220Y kv, X = 15 %

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

EC6503 Transmission Lines and WaveguidesV Semester Question Bank

EC TRANSMISSION LINES AND WAVEGUIDES TRANSMISSION LINES AND WAVEGUIDES

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

TRANSMISSION LINE 1. Instructed by: Miss. R T Gunasekara

EL 403 MODEL TEST PAPER - 1 POWER SYSTEMS. Time: Three Hours Maximum Marks: 100

Transmission Lines. Ranga Rodrigo. January 13, Antennas and Propagation: Transmission Lines 1/46

SAMPLE EXAM PROBLEM PROTECTION (6 OF 80 PROBLEMS)

The power transformer

Fatima Michael college of Engineering and Technology

R10. III B.Tech. II Semester Supplementary Examinations, January POWER SYSTEM ANALYSIS (Electrical and Electronics Engineering) Time: 3 Hours

Extended Transmission Line Loadability Curve by Including Voltage Stability Constrains

PROTECTION APPLICATION HANDBOOK

Voltage Source Converter Modelling

Transmission Lines. Ranga Rodrigo. January 27, Antennas and Propagation: Transmission Lines 1/72

EE 741. Primary & Secondary Distribution Systems

EC Transmission Lines And Waveguides

AC Power Instructor Notes

Chapter 10: Compensation of Power Transmission Systems

Transmission Line Transient Overvoltages (Travelling Waves on Power Systems)

Harmonic resonances due to transmission-system cables

Dynamic Model Of 400 Kv Line With Distance Relay. Director Research, The MRPC Company, Hyderabad, India 2

PAPER-II (Subjective)

Class XII Chapter 7 Alternating Current Physics

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Power Quality enhancement of a distribution line with DSTATCOM

Pulse Transmission and Cable Properties ================================

Frequency Domain Analysis of Capacitor Transient Overvoltages

Incorporation of Self-Commutating CSC Transmission in Power System Load-Flow

Distance Protection of Cross-Bonded Transmission Cable-Systems

Grounding Resistance

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

THE ELECTRICAL CHARACTERISTICS OF LONG

University of Pennsylvania Department of Electrical and Systems Engineering ESE319

Var Control. Adding a transformer and transformer voltage regulation. engineers loadflow program. The control system engineers loadflow.

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Using the LC-Lumped Element Model for Transmission Line Experiments

Three-phase short-circuit current (Isc) calculation at any point within a LV installation using impedance method

UNIVERSITY OF SWAZILAND MAIN EXAMINATION, DECEMBER 2016

PHYSICS - CLUTCH CH 29: ALTERNATING CURRENT.

Analysis of a 405 km transmission line with series compensation

LARGE-SCALE WIND POWER INTEGRATION, VOLTAGE STABILITY LIMITS AND MODAL ANALYSIS

Chapter 31 Alternating Current

ETAP PowerStation. Electrical Transient Analyzer Program. ETAP PowerStation. Short Circuit Analysis. ANSI Standard 3-Phase Fault Currents

University of KwaZulu-Natal

The Use of Radio Spectrum. Welcome to. Where is radio used? Compare: Basic Wireless Communication Technique ETIF05. Göran Jönsson

Voltage Sag Index Calculation Using an Electromagnetic Transients Program

Impedance analysis of harmonic resonance in HVDC connected Wind Power Plants

Electromagnetic Oscillations and Currents. March 23, 2014 Chapter 30 1

Aspects of Network Harmonic Impedance Modelling in High Voltage Distribution Networks

1 Introduction General Background The New Computer Environment Transmission System Developments Theoretical Models and Computer Programs

Lecture 4. Maximum Transfer of Power. The Purpose of Matching. Lecture 4 RF Amplifier Design. Johan Wernehag Electrical and Information Technology

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

RLC Frequency Response

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Some aspects regarding harmonic s distortions propagation in large medium voltage distribution system

Case Study 1. Power System Planning and Design: Power Plant, Transmission Lines, and Substations

ELECTRICAL POWER TRANSMISSION TRAINER

Estimation of the Short Circuit Ratio and the Optimal Controller Gains Selection of a VSC System

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Lecturer: Dr. J B E AL-ATRASH No. of Pages: 4

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

AC reactive circuit calculations

3-phase short-circuit current (Isc) at any point within a LV installation

Physics 115. Inductors, Capacitors, and RLC circuits. General Physics II. Session 34

VELAMMAL ENGINEERING COLLEGE, CHENNAI-66 DEPARTMENT OF ELECTRONICS AND COMMUNICATION ENGINEERING

Power Quality Requirements for Connection to the Transmission System

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

2382 IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 50, NO. 4, JULY/AUGUST 2014

MV Network Operation Issues and Elimination of Phase Voltage Unbalance

Beskrivelse av simuleringsmodell ==> Description of simulation model

Errors Due to Shared Leadwires in Parallel Strain Gage Circuits

Power Quality Improvement in Distribution System Using D-STATCOM

What is Corona Effect in Power System and Why it Occurs?

Lecture 5: RC Filters. Series Resonance and Quality Factor. Matching. Soldering.

Figure 1: Closed Loop System

ELECTRICAL POWER ENGINEERING

Look over Chapter 31 sections 1-4, 6, 8, 9, 10, 11 Examples 1-8. Look over Chapter 21 sections Examples PHYS 2212 PHYS 1112

Short-Circuit Analysis IEC Standard Operation Technology, Inc. Workshop Notes: Short-Circuit IEC

Improvement of Power System Distribution Quality Due to Using Dc-Converter Loads and Electric Arc Furnaces. H.A. Khalik, M. A. Aziz, and E. Farouk.

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Introduction to RF Measurement and Nonideal Components The Vector Network Analyzer UCSB - ECE145A/ECE218A Winter 2007

Dynamic Performance Evaluation of an HVDC Link following Inverter Side Disturbances

Design and Simulation of Passive Filter

Passive Component Analysis. OMICRON Lab Webinar Nov. 2015

Damping of Sub-synchronous Resonance and Power Swing using TCSC and Series capacitor

Power System Studies

Transcription:

Exercises on overhead power lines (and underground cables) 1 From the laws of Electromagnetism it can be shown that l c = 1 v 2 where v is the speed of propagation of electromagnetic waves in the environment that surrounds the conductors. Determine the expression of lc from those of l and c (which were derived under some approximations) and compare it to the above exact value. 2 Show that placing the shunt admittance g + jωc to the left of the series impedance r + jωl instead of the right, as in slide 18 of Part 2, yields (luckily!) the same equations d V /dx = zī, dī /dx = y V. 3 What happens if a transmission line of length λ/4 ( quarter-wave line) is connected to a network and left open at the other extremity? The line is assumed lossless, for simplicity. 4 Compute the natural power of : a 380-kV line characterized by: x = 0.3Ω/km, b = 3µS/km. Compare it to the thermal limit: 1350 or 1420 MVA; a 150-kV cable characterized by: x = 0.17Ω/km, b = 60µS/km. Compare it to the thermal limit: lower than 300 MVA. 5 Derive the expressions of the active and reactive power flows in a lossless line of arbitrary length as a function of the voltage magnitudes and phase angles at the terminal buses. 1 / 5

Exercise 6 A transmission corridor is planned to transmit 1000 MW between two 50-Hz networks, over a distance of 600 km, at a nominal voltage of 400 kv. The line is considered lossless, for simplicity, with the per-phase parameters ωl = 0.32 Ω/km and ωc = 3.2 µs/km. The networks are assumed to hold the voltages of the terminal buses at 400 kv 1. 1 Show that the maximum power that can be transferred in a single circuit is lower than 1000 MW. 2 Show that the transfer is possible with a double-circuit line. Compute the voltage at the mid-point of each circuit for a power transfer of respectively 1000 and 0 MW. 3 The double-circuit configuration is not secure since the 1000 MW cannot be transferred if one of the circuits is tripped. Consider the alternative configuration shown below. What is the maximum power transfer if one (of the four half-)line(s) is tripped? 1 2 3 network A P 300 km 300 km network B 1 to me more realistic, the Thévenin reactance of each network should be considered; it is ignored to keep the computations simple 2 / 5

4 To operate with a higher security margin, a compensator is connected to the middle bus 2 to hold the voltage of the latter at 400 kv. The compensator produces or consumes reactive power but no active power (losses are neglected). What is the maximum power transfer with all lines in service and when one of them is tripped? 5 Which reactive power must the compensator be able to produce and consume to hold its terminal voltage at 400 kv for all power transfers between 0 and 1000 MW? 3 / 5

Exercise 7 Consider the two cables with the following characteristics: ω c U nom (kv) S nom (MVA) r (Ω/km) ω l (Ω/km) (µs/km) 2 150 200 0.07 0.17 25 36 20 0.11 0.13 50 Assume that each cable is connected under its nominal voltage at one end, and left open at the other end. Determine how the current entering the cable and the voltage at the open end evolve with the length d of the cable. Perform the computation: using the complete pi-equivalent of the cable, and treating the cable as a shunt capacitor only. The results are shown in the figures hereafter. They illustrate the difficulty of using AC cables over long distances. 4 / 5

150-kV cable: RMS value of current entering the cable and RMS voltage at the open end 36-kV cable: RMS value of current entering the cable and RMS voltage at the open end 5 / 5