Contactors and Contactor Assemblies

Similar documents
Controls Contactors and Contactor Assemblies Special Applications

Output of three-phase motors at 50 Hz and 400 V

For non-electrical quantities

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Technical features table for miniature circuit-breakers SH 200 Series

Characteristics 5 TeSys k contactors and reversing contactors

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Type: DILEM 10 G(24VDC) Article No.:

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Electronic timer CT-SDD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Thermistor motor protection relays

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

CONTACTORS FOR CAPACITOR SWITCHING

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Pluggable interface relays CR-P Pcb relays

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

NS..S contactor relays - with spring terminals AC operated

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Electronic timer CT-TGD.22

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

PKZ 2 Manual Motor Protectors Technical Data

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-SDS.22

Description Basic devices with positive operation contacts

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Thermistor motor protection relays

Protection and safety SQZ3 phase and sequence relay

Electronic timer CT-SDE

Subject to changes 11/2003 Page 1/7

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Solid-State Soft Starters

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

3 - Protection components Circuit-breakers

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Capacitor Switching Contactors

Control module CP-A CM

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Protection components

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Electronic timers CT-S range Selection and ordering details

Type: DILM40(RDC24) Article No.:

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Data sheet Functional Electronics PRO-M. Power supplies for space-saving use in automation technology

XT IEC Power Control Miniature Controls

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Solid State Relay, 1-phase

Protection components

Controls Solid-State Switching Devices

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PFE and CM-PFE.2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

E-STOP relays, safety gate monitors

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

IMPULSE SWITCH, REMOTE SWITCH

48 Series - Relay interface modules A. Features

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Three-phase monitoring relay CM-PFS

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Three-phase monitoring relay

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Moeller Electric Corporation

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Datasheet - PROTECT-IE-02

Transcription:

s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation and forward inclination up to 22.5 : coil voltage tolerance 5... 1.1 U s Upright mounting position: Special design required. Positions 13... 16 of the Order No. must be changed to -10. dditional charge. DC operation Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e Rated insulation voltage U i (pollution degree 3) V 1000 Rated impulse withstand voltage U imp kv 6 Safe isolation between coil and main contacts (acc. to DIN VDE 0106 Part 101 and 1 [draft 2/89]) Permissible ambient temperature in operation when stored V 690 25... +60 55... +80 Degree of protection acc. to IEC 60 947-1 and DIN 40 050 IP 20 (terminal compartment IP 00), coil system IP 40 Shock resistance Rectangular pulse C and DC operation g/ 6.8/5 and 4/10 Sine pulse C and DC operation g/ 10.6/5 and 6.2/10 Conductor cross-sections See page 2/143 Short-circuit protection of contactors without overload relays Fuse links, utilization category gl/gg NH, 3N of coord. "1" 2 ) 250 Fuse links, utilization category gr SITOR, 3NE of coord. "2" 2 ) 250 uxiliary circuit Fuse links, utilization category gl/gg (weld-free protection at I k 1 k) 10 DIZED 5SB, NEOZED 5SE or miniature circuit-breaker with C-characteristic (I k < 400 ) 10 Control circuit Coil voltage tolerance C/DC... 1.1 U s Power consumption of the coils (with coil in cold state and 1.0 U s ) Standard design For US and Canada Hz 50 50/60 50 60 270 0.68 22 0.27 DC operation = W 15 Operating times at... 1.1 U 1 s ) Break-time = + arcing time time 17... 90 10... 25 DC operation time 90... 230 14... 20 rcing time 10... 15 Operating times at 1.0 U s 1 ) DC operation time time 18... 30 11... 23 100... 120 16... 20 298 /274 0.7 / 0.62 27 / 20 0.29/ 0.31 270 0.68 22 0.27 300 0.52 21 0.29 1) The s of the NO contacts and the times of the NC contacts increase if the contactor coils are protected against voltage peaks: varistor +2 to 5, diode assemblies 2 to 6 times. 2/128 2) ccording to excerpt from IEC 60 947-4-1 (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated.

s for Special pplications Technical data Load ratings with C C-1 utilization category, switching resistive load Rated operational currents I e Ratings of three-phase loads = 5 (at 60 ) at 40 up to 690 V at 60 up to 690 V at 1000 V at 230 V 400 V 500 V 690 V 1000 V Minimum conductor cross-section with I e load at 40 at 60 C-2 and C-3 utilization categories With an electrical endurance of 1.3 million operating S3 3RT14 46 140 60 50 86 107 148 98 mm 2 50 mm 2 50 Rated operational current I e up to 690 V 44 Ratings of slipring or squirrel-cage motors at 50 Hz and 60 Hz (at 60) at 230 V 400 V 500 V 690 V 12.7 22 29.9 38.2 Power loss per conducting path at I e /C-1 W 12.5 Load ratings with DC DC-1 utilization category, switching resistive load L/R 1 ) Number of conducting paths when connected in series 1 2 3 Rated operational currents I e (at 60 ) up to 24 V 60 V 110 V 80 12 220 V 440 V 600 V DC-3 and DC-5 utilization categories, shunt and series motors Number of conducting paths when connected in series 1 2 3 Rated operational currents I e (at 60 ) up to 24 V 60 V 110 V 220 V 440 V 600 V 2.5 0.48 6 3 1.25 0.35 0.15 0.1 13 2.4 1.3 1.75 0.42 0.27 Operating frequency Operating frequency z in operating per hour DC operation s without overload relays No-load operating frequency 1/h 5000 1000 Rated operation Dependence of the operating frequency z on the operational current I and the operational voltage U : for C-1 for C-3 1/h 1/h 650 1000 650 1000 6 3.4 4 0.45 z = z I --- e I 400V ---------- U 1.5 1/h 2/129

s for Special pplications 2/

s for Special pplications Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. S6 3RT14 56 Mechanical endurance Electrical endurance C-1 utilization category at I e Oper. Oper. 10 million Rated insulation voltage U i (pollution degree 3) V 1000 Rated impulse withstand voltage U imp kv 8 Safe isolation between coil, auxiliary contacts and main contacts (acc. to DIN VDE 0106 Part 101 and 1 [draft 2/89]) Permissible ambient temperature in operation when stored V 690 0.5 million 25... +60/+55 with S-Interface 55... +80 Degree of protection acc. to IEC 60 947-1 and DIN 40 050 IP 00/open type, coil system IP 20 Shock resistance Rectangular pulse g/ 8.5/5 and 4.2/10 Sine pulse g/ 13.4/5 and 6.5/10 Conductor cross-sections See page 2/132 Electromagnetic compatibility (EMC) See page 2/14 Short-circuit protection Fuse links, utilization category gl/gg, NH, 3N of coordination "1" 355 Fuse links, utilization category gr, SITOR, 3NE of coordination "2" 350 uxiliary circuit Fuse links, utilization category gl/gg 10 (weld-free protection at I k 1 k) DIZED 5SB, NEOZED 5SE or miniature circuit-breaker with C-characteristic (I k < 400 ) Control circuit Coil voltage tolerance C/DC (UC) U s min... 1.1 U s max Power consumption of solenoid mechanism Conventional op. mechanism Solid-state op. mechanism (with coil in cold state and rated range U s min... U s max ) U s min U s max U s min U s max DC operation PLC control input (EN 61 131-2/ 2) DC 24 V/ 30 m Operating times Conventional op. mechanism Solid-state op. mechanism (Break-time = + arcing time) Operation via 1/2 PLC input at U s min... 1.1 U s max time at U s min... U s max time W W 250 4.8 300 4.3 20... 95 40... 60 25... 50 40... 60 300 5.8 360 5.2 190 3.5 0.5 250 2.3 95... 135 80... 90 100... 120 80... 90 280 4.4 0.4 320 2.8 35... 75 80... 90 40... 60 80... 90 rcing time 10... 15 10... 15 10... 15 Load ratings with C C-1 utilization category, switching resistive load Rated operational currents I e Ratings of three-phase loads = 5 (at 60 ) at 40 up to 690 V at 60 up to 690 V at 1000 V at 230 V 400 V 500 V 690 V 1000 V Minimum conductor cross-section with I e load at 40 at 60 275 250 100 95 165 205 285 165 mm 2 2 70 mm 2 120 Power loss per conducting path at I e /C-1 W 20 2/131

s for Special pplications 2/132

s for Special pplications Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. S10 3RT14 66 S12 3RT14 76 Mechanical endurance Electrical endurance C-1 utilization category at I e Oper. Oper. 10 million Rated insulation voltage U i (pollution degree 3) V 1000 Rated impulse withstand voltage U imp kv 8 Safe isolation between coil, auxiliary contacts and main contacts (acc. to DIN VDE 0106 Part 101 and 1 [draft 2/89]) Permissible ambient temperature in operation when stored V 690 0.5 million 25... +60/+55 with S-Interface 55... +80 Degree of protection acc. to IEC 60 947-1 and DIN 40 050 IP 00/open type, coil system IP 20 Shock resistance Rectangular pulse g/ 8.5/5 and 4.2/10 Sine pulse g/ 13.4/5 and 6.5/10 Conductor cross-sections See page 2/135 Electromagnetic compatibility (EMC) See page 2/14 Short-circuit protection Fuse links, utilization category gl/gg, NH, 3N of coordination "1" 500 800 Fuse links, utilization category gr, SITOR, 3NE of coordination "2" 500 710 uxiliary circuit Fuse links, utilization category gl/gg (weld-free protection at I k 1 k) DIZED 5SB, NEOZED 5SE or miniature circuit-breaker with C-characteristic (I k < 400 ) 10 Control circuit S10 3RT14 66 Coil voltage tolerance C/DC (UC) U s min... 1.1 U s max Power consumption of solenoid mechanism Conventional op. mechanism Solid-state op. mechanism (with coil in cold state and rated range U s min... U s max ) U s min U s max U s min U s max DC operation PLC control input (EN 61 131-2/ 2) DC 24 V/ 30 m Operating times Conventional op. mechanism Solid-state op. mechanism (Break-time = + arcing time) Operation via 1/2 PLC input at U s min... 1.1 U s max time at U s min... U s max time W W 490 5.6 540 6.1 30... 95 40... 80 35... 50 50... 80 590 6.7 650 7.4 400 4 0.5 440 3.2 105... 145 80... 200 110... 80... 100 530 5 0.4 580 3.8 45... 80 80... 100 50... 65 80... 100 rcing time 10... 15 10... 15 10... 15 2/133

s for Special pplications 2/134

s for Special pplications 2/135