E2T0 DVP

Similar documents
E2P0 DVP

INSTRUCTION SHEET. Eaton Logic Controller ELCM TC Temperature Modules. [Applicable Temperature modules] ELCM-TC04ANNN MTN1

LX3V-8ITC User manual

VersaPoint I/O Module

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation

Series Valve Temperature Controller. Instruction Sheet

XC series PLC expansion module User Manual

Series Temperature Controller Instruction Sheet

Fuzzy Temperature Controllers E5AF

High Resolution Thermocouple Module Product Specifications and Installation Data

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

Series Temperature Controller Instruction Sheet

This Errata Sheet contains corrections or changes made after the publication of this manual.

LYPLC Ex1n4AD Ex1n4TC

GE Fanuc IC695ALG600. Rx3i PacSystem

CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV

GE Fanuc IC695ALG312. Rx3i PacSystem

Thermocouple / Millivolt Input Module HE800THM000 / HE800THM100 HE820THM000 / HE820THM100* * HE820 denotes plastic case.

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

Isolated RTD Modules Product Specifications and Installation Data

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

PACSystems* RX3i IC695ALG600-DD

Data Acquisition Modules/ Distributed IO Modules

F4-08RTD 8-Channel RTD Input

Modicon Momentum automation platform 0

The SCB-68 is a shielded board with 68 screw terminals for easy connection to National Instruments 68-pin products.

PACSystems* RX3i IC695ALG600

Process displays For standard signals, temperature, resistance measurement

Temperature Transmitters - Head Mounted

P1-04THM Analog Input

Analog Modules AS-i IP20

VersaPoint I/O Module

F4 04DAS 1 4-Channel Isolated 4 20mA Output

IB ST (ZF) 24 PT 100 4/4

TxBlock-USB Transmitter

High Performance Process & Temperature Controllers

FC Series Signal Conditioners

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

MODEL: R30US4. Remote I/O R30 Series

FM 355 CONTROLLER MODULE

Excellent low-cost Process & Temperature Controllers

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

Z170REG-1. Universal converter module with galvanic insulation between 2 analog outputs

Analogue temperature controllers

MV110-8AS. Analog input module 8 channel. User guide

UniStream Uni-I/O Modules

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

XC-E6TCA-P Temperature control module User s manual


Temperature Transmitters - DIN Rail Mounted

Ultrasonic Displacement Sensor E4DA

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

This Datasheet is for the IC693ALG220. Analog Voltage Input - 4 Channel.

Barrel Temperature Control Module

APPENDIX APPENDIX A 1

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MV110-8A. Analog input module 8 channel. User guide

PFXLM4B01 D * * (1) (2) (3) (4)

VB - 4AD 4 Channels Analog Input Module

F4 08DA 2 8-Channel Analog Voltage Output

Uni-Mux XQL Multi-Channel Data Acquisition Module

Vibration 10 Times in X,Y,Z IEC In Case of Continuous Vibration

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Chapter 18 FBs-6AD Analog Input Module

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

BNC/TC-2095 RACK-MOUNT ADAPTER

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

INSTALLATION MANUAL. SENECA s.r.l. Via Germania, Z.I. CAMIN PADOVA ITALY Tel Fax

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Fuzzy Temperature Controllers E5EF

Temperature Controllers E5 J

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

Models UT350/UT320 Digital Indicating Controllers

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

Z170REG. Universal converter module with galvanic insulation between 2 analog outputs

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

PSI Temperature Scanners

TBX-68S Isothermal Terminal Block

MELSEC-L Temperature Control Module User's Manual -L60TCTT4 -L60TCTT4BW -L60TCRT4 -L60TCRT4BW

10-CH Digital Thermometer Module

SCXI 8-Channel Isolated Analog Input Modules

Efficiency higher than 85% Power Factor >95% Case TC* Protec on

F4 16DA 2 16-Channel Analog Voltage Output

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

PACSystems* RX3i. Isolated RTD Input Module, 8 Channels, IC695ALG508-CA. Module Features. GFK-2501C November 2012

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

Allen-Bradley. User Manual. Barrel Temperature Control Module (Cat. No BTM) AB Parts

USB-2404-UI Specifications

Safety Precautions. Copyright / Trademarks

Transcription:

29-5-26 5116868-E2T DVP-11363-1

ENGLISH Thank you for choosing Delta s DVP series PLC. DVP4TC-E2 measurement module receives 4 points of external thermocouple sensors (J-type, K-type, R-type, S-type, T-type, E-type, N-type, 8mV) and convert them into 16-bit digital signals. Users can select s in Celsius (resolution:.1 C) or Fahrenheit (resolution:.1 F). In addition, you can access the data in the module by applying FROM/TO instructions or read the average value of channels directly by using MOV instruction (Please refer to allocation of special registers D99 ~ D9999). This instruction sheet provides only information on the electrical specification, general functions, installation and wiring. For detailed program design and applicable instructions, please refer to DVP-ES2 Operation Manual: s. For details of the optional peripheral, please refer to the instruction sheet enclosed in it. This is an OPEN TYPE I/O module and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for operating the enclosure) in case danger and damage on the device may occur. DO NOT connect the AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all the wiring again before switching on the power. Make sure the ground terminal is correctly grounded in order to prevent electromagnetic interference. Product Profile & Dimension Removable I/O terminal Model Name Power / A->D / Error indicators I/O module connection port 4TC-E2 4AI-TC Mounting slot (35mm) I/O module clip I/O module connection port I/O terminal No. Direct mounting hole [ Figure 1 ] 9 98 16 11 62 7 78 61.5 [ Figure 2 ] Unit: mm - 1 -

External Wiring Thermocouple + Voltage -8mV~8mV Terminal of power module - Grounding (1 Shielded cable *1 Shielded cable *1 *2 System grounding or less) CH1 CH4-2 - I1+ I1 - I4+ I4-24V V Cold-Junction Compensation DC/ DC Converter Note 1: Wiring for analog should adopt the connection cable or shielding cable of thermocouple sensor J-type, K-type, R-type, S-type, T-type, E-type and N-type and should be separated from other power cable or wirings that may cause interference. Note 2: Connect the terminal on both power module and DVP4TC-E2 to the system grounding point then ground the point or connect it to the cover of power distribution cabinet. I/O Terminal Layout I1+ I1- I2+ I2- I3+ I3- I4+ I4- DVP4TC-E2 (4AI) 24V V Electrical Specifications DVP4TC-E2 Power supply voltage 24VDC (2.4VDC ~ 28.8VDC) (-15% ~ +2%) Max. rated power consumption Connector Operation/storage Vibration/shock immunity Series connection to DVP-PLC MPU 1.2W, supplied by external power source MUX 5V AG European standard removable terminal block (Pin pitch: 5mm) Operation: C~55 C (temp.), 5~95% (humidity), Pollution degree2 Storage: -25 C~7 C (temp.), 5~95% (humidity) International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) The modules are numbered from to 7 automatically by their distance from MPU. No. is the closest to MPU and No.7 is the furthest. Maximum 8 modules are allowed to connect to MPU and will not occupy any digital I/O points. Functions Specifications DVP4TC-E2 Celsius ( C) Fahrenheit ( F) Analog channel 4 channels Digital data format Response time Overall accuracy Applicable sensor type 2 s complement of 16 bits 2ms / each channel Voltage ±.3% when in full scale (25 C, 77 F) ±.6% when in full scale within the range of ~ 55 C, 32 ~ 131 F J-type, K-type, R-type, S-type, T-type, E-type, N-type thermocouple; ±8mV voltage

DVP4TC-E2 Celsius ( C) Fahrenheit ( F) Range of Range of digital conversion J-type: -1 C ~1,15 C K-type: -1 C ~ 1,35 C R-type: C ~ 1,75 C S-type: C ~ 1,75 C T-type: -15 C ~ 39 C E-type: -15 C ~ 98 C N-type: -15 C ~ 1,28 C J-type: K-1, ~ K11,5 K- type: K-1, ~ K13,5 R-type: K- ~ K17,5 S-type: K ~ K17,5 T-type: K-1,5 ~ K3,9 E-type: K-1,5 ~ K9,8 N-type: K-1,5 ~ K12,8 J-type: -148 F ~ 2,12 F K-type: -148 F ~ 2,462 F R-type: 32 F ~ 3,182 F S-type: 32 F ~ 3,182 F T-type: -238 F ~734 F E-type: -238 F ~ 1,796 F N-type: -238 F ~2,336 F J-type: K-1,48 ~ K21,2 K-type: K-1,48 ~ K24,62 R-type: K32 ~ K31,82 S-type: K32 ~ K31,82 T-type: K-2,38 ~ K7,34 E-type: K-2,38 ~ K17,96 N-type: K-2,38 ~ K23,36 Resolution 16 bits (.1 C) 16bits (.1 F) Average function Voltage ±8mV ±8, 16 bits (.1mV) Supported. Available for setting up sampling range in CR#8 ~ CR#11. Range: K1 ~ K1. Self-diagnosis Isolation Upper and lower bound detection in all channels Optical coupler isolation between digital circuits and analog circuits. Isolation between analog channels. 5VDC between digital circuits and Ground 5VDC between analog circuits and Ground 5VDC between analog circuits and digital circuits 5VDC between 24VDC and Ground 12VAC between analog channels Control Register CR# Attrib. Register content Description # O R Model name Set up by the system: DVP4TC-E2 model code = H 83 #1 O R Firmware version Display the current firmware version in hex. #2 O R/W CH1 Input mode setting #3 O R/W CH2 Input mode setting #4 O R/W CH3 Input mode setting #5 O R/W CH4 Input mode setting #7 O R/W Temperature unit setting #8 O R/W CH1 sampling range #9 O R/W CH2 sampling range #1 O R/W CH3 sampling range #11 O R/W CH4 sampling range #12 X R #13 X R Average measured at CH1 Average measured at CH2-3 - Input mode: Default = H. Take CH1 for example: Mode (H ): J-type (-1 C ~1,15 C) Mode 1 (H 1): K-type (-1 C ~ 1,35 C) Mode 2 (H 2): R-type ( C ~ 1,75 C) Mode 3 (H 3): S-type ( C ~ 1,75 C) Mode 4 (H 4): T-type (-15 C ~ 39 C) Mode 5 (H 5): E-type (-15 C ~ 98 C) Mode 6 (H 6): N-type (-15 C ~ 1,28 C) Mode 7 (H 7): -8mV~+8mV Mode -1(H FFFF): Close Select the unit (Celsius C / Fahrenheit F). Default = H( C) Set sampling range at CH1 ~ CH4 Range = K1 ~ K1 Default = K1 Average measured at CH1 ~ Ch2 Temperature unit: set in CR#7

CR# Attrib. Register content Description #14 X R #15 X R #2 X R #21 X R #22 X R #23 X R Average measured at CH3 Average measured at CH4 Present measured at CH1 Present measured at CH2 Present measured at CH3 Present measured at CH4 #28 O R/W Adjusted Offset value of CH1 #29 O R/W Adjusted Offset value of CH2 #3 O R/W Adjusted Offset value of CH3 #31 O R/W Adjusted Offset value of CH4 Average measured at CH3 ~ Ch4 Temperature unit: set in CR#7 Present measured at CH1 ~ CH4 Temperature unit: set in CR#7 Set the adjusted Offset value of Ch1 ~ Ch4. Default = K Range: K-4 ~ K4 Temperature unit: set in CR#7 Definition of Offset at Ch1 ~ Ch4 in DVP4TC-E2: Deviation digital value from the target value. #4 O R/W #41 X R/W #42 X R/W #43 X R Error status #1 O R/W Function: Set value changing prohibited Function: Save all the set values Function: Return to default setting Function: Enable / Disable limit detection #11 X R/W Upper and lower bound status #12 O R/W Set value of CH1 upper bound #13 O R/W Set value of CH2 upper bound #14 O R/W Set value of CH3 upper bound #15 O R/W Set value of CH4 upper bound #18 O R/W Set value of CH1 lower bound #19 O R/W Set value of CH2 lower bound #11 O R/W Set value of CH3 lower bound #111 O R/W Set value of CH4 lower bound CR#43: Error status value. See the table below: Prohibit set value changing in CH1 ~ CH4 Save all the set values, Default =H Set all values to default setting, Default = H Register for storing all error status. See the table of error status for more information. Enable / Disable the upper and lower bound detection function. Default= H. Display the upper and lower bound value, Default =H Set value of CH1~CH4 upper bound. Default = K32. Set value of CH1~CH4 lower bound. Default = K-32. Description bit K1 (H 1) Power supply error bit6 K64 (H 4) CH4 Conversion error bit1 K2 (H 2) Hardware error bit9 K512(H 2) Mode setting error bit2 K4 (H 4) Upper / lower bound error bit1 K124(H 4) bit3 K8 (H 8) CH1 Conversion error bit11 K248(H 8) bit4 K16 (H 1) CH2 Conversion error bit12 K496(H 1) bit5 K32 (H 2) CH3 Conversion error bit13 K8192(H 2) Sampling range error Upper / lower bound setting error Set value changing prohibited Communication breakdown on next module - 4 -

Description Note: Each error status is determined by the corresponding bit (b ~ b13) and there may be more than 2 errors occurring at the same time. = normal; 1 = error PID Control Registers CR# CH1 CH2 CH3 CH4 #12 #14 #16 #18 O R/W Save Register content Description Set value Please set the value according to proper range of each sensor type. Default = K #121 #141 #161 #181 O R/W Sampling time (s) Range: K1 ~ K3 (s). Default = K2 #122 #142 #162 #182 O R/W K P Proportional control constant. Default = K121 #123 #143 #163 #183 O R/W K I Integral constant. Default = K2,98 #124 #144 #164 #184 O R/W K D Derivative constant. Default = K-29 #125 #145 #165 #185 O R/W Upper limit of I value Upper limit of I value. Default = K #126 #146 #166 #186 O R/W Lower limit of I value Lower limit of I value. Default = K #127 #147 #167 #187 X R I value Current accumulated offset value #128 #148 #168 #188 O R/W Heating/cooling : Heater, 1: Cooler. Default = K #129 #149 #169 #189 O R/W Upper limit of output Upper limit of output. Default = K32, #13 #15 #17 #19 O R/W Lower limit of output Lower limit of output. Default = K #131 #151 #171 #191 X R Output percentage Output percentage (Unit:.1%) #132 #152 #172 #192 X R Output width (ms) Width of control output. Unit: ms #133 #153 #173 #193 X R Output cycle (ms) Cycle of control output. Unit: ms #134 #154 #174 #194 X R Output volume Output volume #135 #155 #175 #195 X R/W PID_RUN/STOP : STOP, 1: RUN. Default = K #136 #156 #176 #196 X R/W Auto-tuning : Disabled, 1: Auto-tuning. Default = K Symbols: O: When CR#41 is set to H 5678, the set value of CR will be saved. X: set value will not be saved. R: able to read data by using FROM instruction. W: able to write data by using TO instruction. Explanation on Special Registers D99~D9999 When DVP-ES2 MPU is connected with modules, registers D99~D9999 will be reserved for storing values from modules. You can apply MOV instruction to operate values in D99~D9999. When DVP-ES2 MPU is connected with DVP4TC-E2, the configuration of special registers is as below: # #1 #2 #3 #4 #5 #6 #7 Description D132 D1321 D1322 D1323 D1324 D1325 D1326 D1327 Model Code D99 D991 D992 D993 D994 D995 D996 D997 D991 D9911 D9921 D9931 D9941 D9951 D9961 D9971 D992 D9912 D9922 D9932 D9942 D9952 D9962 D9972 D993 D9913 D9923 D9933 D9943 D9953 D9963 D9973 CH1 average CH2 average CH3 average CH4 average - 5 -

Note 1: D99 ~ D9999 are average values of CH1 ~ CH4 and the sampling range is K1 ~ K1. When the sampling range is set to K1, the values displayed in D99~D9999 are current values. You can use: 1. ES_AIO Configuration Function of WPLSoft or 2. FROM/TO instructions (CR#8 ~ CR#11) to set the sampling range as K1. Adjust TC Conversion Curve Users can adjust the conversion curves according to the actual needs by changing the Offset value (CR#28 ~ CR#31). Offset in DVP4TC-E2: Deviation digital value from the target value. Equation for measured Mode ~ Mode6:.1 X ( ) Y Offset. 1( ) Y=, X= Equation for voltage Mode7:.1mV = 8mV/8 X (mv ) Y Offset. 1(m V ) Mode : J-type thermocouple +11,5 (+21,2) Y=, X=Voltage Mode 1: K-type thermocouple +13,5 (+24,62) -1 C (-148 F) -1 C (-148 F) +1,15 C (+2,12 F) -1,(-1,48) +1,35 C (+2,462 F) -1,(-1,48) Mode 2: R-type thermocouple Mode 3: S-type thermocouple +17,5 (+31,82) Mode 4: T-type thermocouple +3,9 (+7,34) C (-32 F) -15 C (-238 F) (-32) +1,75 C (+3,182 F) +39 C (+734 F) -1,5(-2,38) Mode 5: E-type thermocouple +9,8 (+17,96) Mode 6: N-type thermocouple +12,8 (+23,36) -15 C (-238 F) -15 C (-238 F) impedance +98 C (+1,796 F) -1,5(-2,38) +1,28 C (+2,336 F) -1,5(-2,38) - 6 -

Mode of CR#2~ CR#5-1 C ~ 115 C (-1~115) -148 F ~ 212 F (-148~212) Mode 1 of CR#2~ CR#5-1 C ~ 135 C (-1~135) -148 F ~ 2462 F (-148~2462) Mode 2, 3 of CR#2~ CR#5 C ~ 175 C (~175) 32 F ~ 3182 F (32~3182) Mode 4 of CR#2~ CR#5-15 C ~ 39 C (-15~39) -238 F ~ 734 F (-238~734) Mode 5 of CR#2~ CR#5-15 C ~ 98 C (-15~98) -238 F ~ 1796 F (-238~1796) Mode 6 of CR#2~ CR#5-15 C ~ 128 C (-15~128) -238 F ~ 2336 F (-238~2336) Offset (CR#34 ~ CR#37) Deviation digital value corresponds to C/ F Mode 7: +8, Digital output -8mV +8mV Voltage -8, Mode 7 of CR#2~ CR#5-8mV ~ +8mV (-8~8) Offset (CR#34 ~ CR#37) Deviation digital value corresponds to mv - 7 -