SKN3022 PROCESS INSTRUMENTATION CHAPTER III INSTRUMENTATION CHARACTERISTICS

Similar documents
Measurement system applications. Measurement System

Introduction to Measurement Systems

Chapter 1 Introduction

Sensor Terminology. 1/5

Performance Characteristics

MAE334 - Introduction to Instrumentation and Computers. Final Exam. December 11, 2006

PHYS 1402 General Physics II Experiment 5: Ohm s Law

Proportional-Integral Controller Performance

Table of Contents...2. About the Tutorial...6. Audience...6. Prerequisites...6. Copyright & Disclaimer EMI INTRODUCTION Voltmeter...

Question Bank SENSORS AND INSTRUMENTATION [EE-305/405]

Sensing and Sensors: Fundamental Concepts

LM134/LM234/LM334 3-Terminal Adjustable Current Sources

BEHAVIOR OF PURE TORQUE AND TORQUE WITH CROSS FORCE MEASUREMENT OF TORQUE TRANSDUCER

Industrial Instrumentation

1. A transducer converts

Digital Panel Meter Glossary

Electronics II. Calibration and Curve Fitting

Sensors. Chapter 3. Storey: Electrical & Electronic Systems Pearson Education Limited 2004 OHT 3.1

WEIGHING SYSTEM CALIBRATION USING A LOAD CELL SIMULATOR

DRG-SC Series Signal Conditioners

Scope of Capabilities

The AD620 Instrumentation Amplifier and the Strain Gauge Building the Electronic Scale

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

PHYSICS Part 2. Outline

LESSON 2: ELECTRONIC CONTROL

ELG4139: Converters Analog to Digital Converters (ADCs) Digital to Analog Converters (DACs)

ANALOG TO DIGITAL CONVERTER ANALOG INPUT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Control Theory. This course will examine the control functions found in HVAC systems and explain the different applications where they are applied.

TRANSMITTER CALIBRATION

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

CHAPTER ELEVEN - Interfacing With the Analog World


SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE) UNIT I

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Advanced Methodology for Precisely Simulating RTD Sensor Types

A-level Physics. PHY6T/Q14 Final Marking Guidelines. 2450/2455 June 2014 PMT. Version/Stage: 1.0 Final Marking Guidelines

Chapter 6. BJT Amplifiers

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

1 Diodes. 1.1 Diode Models Ideal Diode. ELEN 236 Diodes

MECE 3320 Measurements & Instrumentation. Data Acquisition

MEASUREMENT AND INSTRUMENTATION QUESTION BANK UNIT I INTRODUCTION. Part A

Introduction. ELCT903, Sensor Technology Electronics and Electrical Engineering Department 1. Dr.-Eng. Hisham El-Sherif

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Instructors. Web Site. Textbook. Grading Policy. Lecture. Lab. Examinations MAE 334 INTRODUCTION TO COMPUTERS AND INSTRUMENTATION

H3A Magnetic Field Transducer

Glossary of VCO terms

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION

Bachelor of Engineering Technology in Control and Automation Systems. Bachelor of Engineering Technology in Electrical Energy Systems

OHM S LAW. Ohm s Law The relationship between potential difference (V) across a resistor of resistance (R) and the current (I) passing through it is

Precision, Low Power, Micropower Dual Operational Amplifier OP290

DC Bias. Graphical Analysis. Script

ni.com Sensor Measurement Fundamentals Series

Applications of the LM392 Comparator Op Amp IC

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en

SENSOR AND MEASUREMENT EXPERIMENTS

ELG3336: Converters Analog to Digital Converters (ADCs) Digital to Analog Converters (DACs)

Section 9 Glossary, Unit Conversions & Kulite Reports

Diode as a Temperature Sensor

LOVAG GENERAL INSTRUCTION G2 MEASUREMENT UNCERTAINTY. This instruction of a general nature and does not relate to specific standards.

UNIVERSITY OF JORDAN Mechatronics Engineering Department Measurements & Control Lab Experiment no.1 DC Servo Motor

Piecewise Linear Circuits

EEE3410 Microcontroller Applications Department of Electrical Engineering. Lecture 10. Analogue Interfacing. Vocational Training Council, Hong Kong.

Certificate of Accreditation

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

110 to 330 Ω/ Ω 20 mω 330 to 1.1 kω/0.001 Ω 20 mω. 110 to 330 kω/0.1 Ω 12.8 Ω. 33 to 110 kω/0.1 Ω 4.1 Ω

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

Receiver Controller and Transmitter

Strain gauge measurements of rotating parts with telemetry

Voltage-to-Frequency and Frequency-to-Voltage Converter ADVFC32

OSCILLOSCOPES, MULTIMETERS, & STRAIN GAGES

To Calibrate or Not to Calibrate a fieldbus transmitter? Dale Perry Pressure Marketing Manager Rosemount

Downloaded from Downloaded from

ECEN 325 Lab 5: Operational Amplifiers Part III

Homework Assignment 06

Dimensional Up to 25 mm/ mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm

2 Oscilloscope Familiarization

BASIC ELECTRONICS PROF. T.S. NATARAJAN DEPT OF PHYSICS IIT MADRAS

Analogue to Digital Conversion

MP A Fixed Frequency White LED Driver

Graphing Techniques. Figure 1. c 2011 Advanced Instructional Systems, Inc. and the University of North Carolina 1

Lab assignment: Strain gauge

Module 1, Lesson 2 Introduction to electricity. Student. 45 minutes

A R T A - A P P L I C A T I O N N O T E

Community College of Allegheny County Unit 7 Page #1. Analog to Digital

Fast and Accurate Measurement of Linear Transducer Parameters

Homework Assignment 07

Analogue to Digital Conversion

Assessing Measurement System Variation

Precision in Practice Achieving the best results with precision Digital Multimeter measurements

1 INTRODUCTION ORDER CODE / INFORMATION

Response time reduction of the ZXCT1009 Current Monitor

University of Tennessee at. Chattanooga

Rayat Shikshan Sanstha s Karmaveer Bhaurao Patil Polytechnic, Satara. Sub: Electrical Engineering Assignment No: 1

SIGNAL CONDITIONING FOR CRYOGENIC THERMOMETRY IN THE LHC

PROPORTIONAL VERSUS NONPROPORTIONAL RELATIONSHIPS NOTES

Equivalent Circuit Determination of Quartz Crystals

Applications of the LM392 Comparator Op Amp IC

Battery Impedance Measurement

Transcription:

SKN3022 PROCESS INSTRUMENTATION CHAPTER III INSTRUMENTATION CHARACTERISTICS Dr Saharudin Haron Hanizam Sulaiman

INSTRUMENTATION CHARACTERISTICS Shows the performance of instruments to be used. Divided into two categories: static and dynamic characteristics. Static characteristics refer to the comparison between steady output and ideal output when the input is constant. Dynamic characteristics refer to the comparison between instrument output and ideal output when the input changes.

1. ACCURACY n Accuracy is the ability of an instrument to show the exact reading. n Always related to the extent of the wrong reading/non accuracy. n Normally shown in percentage of error which of the full scale reading percentage.

Example : A pressure gauge with a range between 0-1 bar with an accuracy of ± 5% fs (full-scale) has a maximum error of: 5 x 1 bar = ± 0.05 bar 100 Notes: It is essential to choose an equipment which has a suitable operating range.

Example : A pressure gauge with a range between 0-10 bar is found to have an error of ± 0.15 bar when calibrated by the manufacturer. Calculate : a. The error percentage of the gauge. b. The error percentage when the reading obtained is 2.0 bar.

Answer : a. Error Percentage = ± 0.15 bar x 100 = ± 1.5% 10.0 bar b. Error Percentage = ± 0.15 bar x 100 = ± 7.5 % 2.0 bar The gauge is not suitable for use for low range reading. Alternative : use gauge with a suitable range.

Example : Two pressure gauges (pressure gauge A and B) have a full scale accuracy of ± 5%. Sensor A has a range of 0-1 bar and Sensor B 0-10 bar. Which gauge is more suitable to be used if the reading is 0.9 bar? Answer : Sensor A : Equipment accuracy (in bar) = ± 5 x 1 bar = ± 0.05 100 Equipment accuracy @ 0.9 bar ( in %) = ± 0.05 bar x 100 = ± 5.6% 0.9 bar

Sensor B : Equipment accuracy (in bar) = ± 5 x 10 bar = ± 0.5 bar 100 Equipment accuracy Conclusion : @ 0.9 bar ( in %) = ± 0.5 bar x 100 = ± 55% 0.9 bar Sensor A is more suitable to use at a reading of 0.9 bar because the error percentage (± 5.6%) is smaller compared to the percentage error of Sensor B (± 55%).

Solution Example : A temperature sensor has a span of 20-250 C. A measurement results in a value of 55 C for the temperature. Specify the error if the accuracy is (a) ±0.5% FS, (b)±0.75% span, and (c)±0.8% of reading. What is the possible temperature in each case. (a) Error = (±0.005)(250 C) = ±1.25 C. Thus, the actual temperature is in the range of 53.75 to 56.25 C. (b) Error = (±0.0075)(250-20) C = ±1.725 C. Thus, the actual temperature is in the range of 53.275 to 56.725 C. (c) Error = (±0.008)(55 C)= ±0.44 C. Thus, the temperature is in the range of 54.56 to 55.44 C.

2. PRECISION An equipment which is precise is not necessarily accurate. Defined as the capability of an instrument to show the same reading when used each time (reproducibility of the instrument).

Example : X : result Centre circle : true value XXX XXX XXX XXXX XXX Low accuracy, high precision X X X High accuracy, high precision x x Comparison of accuracy and precision Low accuracy, low precision

3. TOLERANCE Closely related to accuracy of an equipment where the accuracy of an equipment is sometimes referred to in the form of tolerance limit. Defined as the maximum error expected in an instrument. Explains the maximum deviation of an output component at a certain value.

4. RANGE OF SPAN Defined as the range of reading between minimum value and maximum value for the measurement of an instrument. Has a positive value e.g..: The range of span of an instrument which has a reading range of 100 C to 100 C is 200 C.

5. BIAS Constant error which occurs during the measurement of an instrument. This error is usually rectified or corrected through calibration. Example : A weighing scale always gives a bias reading. This equipment always gives a reading of 1 kg even without any load applied. Therefore, if A with a weight of 70 kg weighs himself, the given reading would be 71 kg. This would indicate that there is a constant bias of 1 kg to be corrected.

6. LINEARITY Maximum deviation from linear relation between input and output. The output of an instrument has to be linearly proportionate to the measured quantity. Normally shown in the form of full scale percentage (% fs). The graph shows the output reading of an instrument when a few input readings are entered. Linearity = maximum deviation from the reading of x and the straight line.

Linearity Output Readings Measured Quantity

7. SENSITIVITY Defined as the ratio of change in output towards the change in input in steady state. Sensitivity (K) = Δθο Δθi Δθο : change in output; Δθi : change in input Example 1: The resistance value of a Platinum Resistance Thermometer changes when the temperature increases. Therefore, the unit of sensitivity for this equipment is Ohm/ C.

Example 2: Pressure sensor A with a value of 2 bar caused a deviation of 10 degrees. Therefore, the sensitivity of the equipment is 5 degrees/bar. Sensitivity of the whole system is (k) = k 1 x k 2 x k 3 x.. x k n θ i k 1 k 2 k 3 θ o

Example: Consider a measuring system consisting of a transducer, amplifier and a recorder, with sensitivity for each equipment given below: Transducer sensitivity 0.2 mv/ C Amplifier gain 2.0 V/mV Recorder sensitivity 5.0 mm/v Therefore, Sensitivity of the whole system: (k) = k 1 x k 2 x k 3 k = 0.2 mv x 2.0 V x 5.0 mm k = 2.0 mm/ C C mv V

Example : The output of a platinum resistance thermometer (RTD) is as follows: Calculate the sensitivity of the equipment. Answer : Input( C) Output(Ohm) 0 0 100 200 200 400 300 600 400 800 Draw an input versus output graph. From that graph, the sensitivity is the slope of the graph. K = ΔR graph slope = (400-200) Ohm = 2 Ohm/ C ΔT (200-100) C

8. DEAD SPACE / DEAD BAND Output Reading - + Measured Variables Dead Space Defined as the range of input reading when there is no change in output (unresponsive system).

9. RESOLUTION The smallest change in input reading that can be traced accurately. Given in the form % of full scale (% fs). Available in digital instrumentation.

Example: A force sensor measures a range of 0 to 150N with a resolution of 0.1% FS. Find the smallest change in force that can be measured. Solution: Because the resolution is 0.1% FS, we have a resolution of (0.001)(150N) = 0.15N, which is the smallest measurable change in force.

10. THRESHOLD When the reading of an input is increased from zero, the input reading will reach a certain value before change occurs in the output. The minimum limit of the input reading is threshold.

DYNAMIC CHARACTERISTICS Explains the behaviour system of instruments system when the input signal is changed. Depends on a few standard input signals such as step input, ramp input and sine-wave input.

DYNAMIC CHARACTERISTICS Step Input Sudden change in input signal from steady state. The output signal for this kind of input is known as transient response. Input Time

DYNAMIC CHARACTERISTICS Ramp Input The signal changes linearly. The output signal for ramp input is ramp response. Input Time

DYNAMIC CHARACTERISTICS Sine-wave Input The signal is harmonic. The output signal is frequency response. Input Time

EXAMPLE OF DYNAMIC CHARACTERISTICS Response from a 2 nd order instrument: Output 100% 90% 10% tr Time

EXAMPLE OF DYNAMIC CHARACTERISTICS Response from a 2 nd order instrument: 1. Rise Time ( tr ) Time taken for the output to rise from 10% to 90 % of the steady state value. 2. Settling time (ts) Time taken for output to reach a steady state value.

Problems 1. A sensor resistance changes linearly from 100 to 180Ω as temperature changes from 20 to 120 C. Find a linear equation relating resistance and temperature. 2. Suppose the temperature range 20 to 120 C is linearly converted to the standard current range of 4 to 20 ma. What current will result from 66 C? What temperature does 6.5 ma represent?.