Flash Shower Valve Rough With Screwdriver Stops Thank you for selecting American-Standard... the benchmark of fine quality for over 0 years. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. INSTALLATION INSTRUCTIONS RECOMMENDED TOOLS Phillips Screwdriver Flat Blade Screwdriver Tubing Cutter Adjustable Wrench Channel Locks Plumbers' Putty or Caulking ROUGHING-IN DIMENSIONS n To assure proper positioning in relation to wall, note roughing-in dimensions. mm 68 mm (6-5/8") FINISHED WALL 7/8" TO " ( TO 50 mm) OR /" NPT OR /" NPT CPVC /" NPT 50 mm (5-7/8") 89 mm (-/") /" STUB OUT /" STUB OUT 0 mm (-/") PLASTER GUARD 0 mm (") -/" MAX. (69 mm) -/" MIN. (5 mm) OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65'' AND 78'' 6 mm 66 mm (6-/") (ASTM F807-) (ASTM F960) 6 mm (ASTM F807-) (ASTM F960) 66 mm (6-/") TOP OF TUB RIM BOTTOM OF TUB " (0 mm) /" NPT NOTE: TO AVOID SHOWER RISE OR OTHER RELATED ISSUES, DO NOT USE PEX CONNECTIONS ON ANY OF THE. Product names listed herein are trademarks of AS America, Inc. AS America, Inc. 08 - -
STANDARD WALL INSTALLATION n See Roughing-in diagram before starting. n Remove the PLASTER GUARD (8) for proper installation. n Mount VALVE BODY to cross brace (" X ") with-in wall. Use wood screws to secure VALVE BODY to brace. n Connect HOT and COLD water supplies per connection method of selected valve. n Connect RISER PIPE () to VALVE BODY () top outlet marked UP. n Connect TUB FILLER PIPE () to bottom outlet. n Cap off shower pipe () and tub filler pipe (5). n With TEST CAP (7) in place and BONNET NUT (6) installed securely, turn on water supplies and check for leaks. n Remove cap to flush the water through shower pipe. n Remove cap 5 to flush the water through tub filler pipe. n Install PLASTER GUARD (8) back onto the valve. Only remove PLASTER GUARD (8) when ready to install trim Kit. n Finished wall should allow for a " diameter opening (Use PLASTER GUARD for guidance) n Screw driver stops are primarly used to shut water off. To shut HOT or COLD water using a flat head screw driver, turn the head of the screw vertically. And to turn the water back on, turn the screw horizontally. NOTE: Cross flow can occur, if hot and cold pressures are not equal during testing. For this situation purchase FLUSH PLUG (M95) separately. See section for test procedures. : After valve installation, inspect the VALVE BODY for any debris. It can damage Pressure Balance Valve cartridge. NOTE: For back to back installation, follow steps mentioned above. Reversal of Hot/Cold water supplies is accomplished by rotating cartridge (supplied with trim) 80 during installation. SIDE VIEW CROSS BRACE -/" (00 mm) 7/8" TO " ( mm to 50 mm) 6 COLD WOOD SCREWS HOT 7 x Cross Brace " (0 mm) SCREW DRIVER 8 -/" MAX. (69 mm) -/" MIN. (5 mm) NOTE: TO AVOID SHOWER RISE OR OTHER RELATED ISSUES, DO NOT USE PEX CONNECTIONS ON ANY OF THE. 5 - -
THIN WALL INSTALL n See Roughing-in diagram before starting. n Finished wall should allow for a -/" diameter opening (Use PLASTER GUARD for guidance). n Remove PLASTER GUARD (8), rotate 90 counter clockwise and install the two screws. (Thin wall text should be on top) n Use SELF-CENTERING HOLE GUIDES (9) as a guide for thin wall install. n LOCKING SCREW (0) keeps valve in place when installing. Completely Thread LOCKING SCREW (0) onto PLASTER GUARD (8). n During the installation, make sure to position the Locking feature screw as shown in Figure A below. Once the valve is positioned on the Thin Wall, turn counterclockwise as shown in Figure B to secure VALVE BODY () in place. n Connect HOT and COLD water supplies per connection method of selected valve. n Connect RISER PIPE () to VALVE BODY () top outlet marked UP. n Connect TUB FILLER PIPE () to bottom outlet. n Cap off shower pipe () and tub filler pipe (5). n With TEST CAP (7) in place and BONNET NUT (6) installed securely, turn on water supplies and check for leaks. n Remove cap to flush the water through shower pipe. n Remove cap 5 to flush the water through tub filler pipe. n Screw driver stops are primarly used to shut water off. To shut HOT or COLD water using a flat head screw driver, turn the head of the screw vertically. And to turn the water back on, turn the screw horizontally. NOTE: Cross flow can occur, if hot and cold pressures are not equal. For this situation purchase FLUSH PLUG (M95) separately. See section for test procedures. : After valve installation, inspect the VALVE BODY for any debris. It can damage Pressure Balance Valve cartridge. NOTE: For back to back installation, follow steps mentioned above. Reversal of Hot/Cold water supplies is accomplished by rotating cartridge (supplied with trim) 80 during installation. SIDE VIEW Fig. A 9 8 0 Hex Wrench mm 0 COLD -/" 7 Fig. B HOT 6 0 5 UNLOCK LOCK - -
TEST PROCEDURES FOR FLUSH PLUG (SOLD SEPARATELY) n Unthread BONNET NUT (). n Remove TEST CAP () and install FLUSH PLUG (). n Rotate FLUSH PLUG () so opening for inlet (HOT or COLD) directs water flow to selected outlet (SHOWER or TUB). n Secure FLUSH PLUG () by tightening BONNET NUT (). n Check for leaks and flush lines. n Repeat steps above to Test/Flush atlernate flow paths. n Upon completion, unthread BONNET NUT (). Remove FLUSH PLUG (), replace with TEST CAP (), and tighten BONNET NUT (). SERVICING n To replace SCREW DRIVER STOP (), unthread it counterclockwise using the hex wrench. n Replace the unit with a new SCREW DRIVER STOP (). - -
Flash Shower Valve Rough With Screwdriver Stops MODEL NUMBERS M9705-0070A FIXATION RING KIT 0505-0070A /" SWEAT PLUG M9705-0070A LOCKING CAM SCREW KIT M9705-0070A SCREWDRIVER PURCHASED SEPARATELY M9705-0070A FIXATION RING KIT M9705-0070A LOCKING CAM SCREW KIT M9705-0070A SCREWDRIVER M95805-0070A DEEP ROUGH-IN KIT HOT LINE FOR HELP For toll-free information and answers to your questions, call: (800) -90 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 0:00 a.m. to :00 p.m. EST IN CANADA -800-87-069 (TORONTO -905-06-09) Weekdays 8:00 a.m. to 7:00 p.m. EST IN MEXICO 0-800-89-00 Product names listed herein are trademarks of AS America, Inc. AS America, Inc. 08 M95-0070A FLUSH PLUG - 5 -