INSTALLATION INSTRUCTIONS

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions 8115F 8115SF

Installation Instructions

Installation Instructions

Flash Rough-In Valves

CALLAS THERMOSTATIC SHOWER SET

EXIRA SHOWER SET INSTALLATION

ONASSIS SHOWER SET INSTALLATION

Installation Instructions

INSTALLATION GUIDELINES

INSTALLATION INSTRUCTIONS

LATTIMORE SHOWER SET INSTALLATION

INSTALLATION GUIDELINES

Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit

SEBASTIAN TUB FAUCET INSTALLATION

INSTALLATION GUIDELINES

Installation Instructions 3/4 Thermostatic Valve Rough-in & Trim (PL8950)

GP-SD GENIE PROBE SMALL DIAMETER

Installation and Maintenance Instructions

CAELI THERMOSTATIC SHOWER PANEL

Bodyspray INSTALLATION INSTRUCTIONS


Acrylic Claw Foot Tub

MALEKO WALL-MOUNT FAUCET INSTALLATION

WHITE ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH

SHELTON THERMOSTATIC SHOWER PANEL

Caution: Installation and Operation Instructions. Locking Mechanism (if supplied) Set Screws Backed Out. Mounting Orientation

caroma marc newson shower mixer

CW-1401 (WL1212) CB-1401 (BL1212)

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

VICTORIAN WIDESPREAD FAUCET

3-way Transfer Valve Trim

Thermostatic Valve Trim

Low Base 3, 4 and 5-Piece Showers with SnapJoint 3/4/5 LBS SJ

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

INSTALLATION INSTRUCTIONS

MUELLER GAS. DH-5 Drilling Machine. For use on 1 1 /2 & 2 Line Stopper Fittings. Reliable Connections. General Information 2

45 CUTTING HEAD TILE SAW-BLADE ALIGNMENT PROCEDURE

Floor-Mounted Tubfiller

Volume Control Valve Trim

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.

ROTUNDA WALL-MOUNT FAUCET INSTALLATION

Traditional Wall Mounted Potfiller

MPA-9000 Universal Ceiling Projector Mount Kit

INSTALLATION INSTRUCTIONS FOR WALL TUB SETS, TWO HANDLE SHOWER SETS AND WALL LAVATORY SET VALVES NUMBERED: RC & RC

STEINBERGER TRANSTREM (TYPE 2) TECHNICAL DOCUMENT

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

1. Fasten press to bench or work surface using the mounting holes provided (Item 3).

General Array Layout Sketch

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

WILLIS WIDESPREAD FAUCET

ASSEMBLY GUIDE. Mia Narrow Bookcase

INSTALLATION INSTRUCTIONS KK-K9-C12-K CHEVY IMPALA

Wall-Mounted Basin Set

WILLIS WALL-MOUNT FAUCET INSTALLATION

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set

installation instructions

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

T : F : Revised June 2013

Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8

Volume Control Valve Trim

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

New Product Release: October 2014 Boone Racks

EMO. Service Instruction. created by Frank Weithöner. Table of contents: Special Tools Assembling Mixing Chamber

Frameless Fixed Panel Slider QCI5279

STEWARD ECO T01-B INSTALLATION INSTRUCTIONS L URINAL (REAR INLET) K-4986T-ER( ) , 2010 Copyright Kohler China Ltd.

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #

Frameless Fixed Panel Slider

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

SINCE 1922 P UBLICATION N O

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

Important Loading Information. Tools Required. Meridian Lateral Files Instructions

BALANTINE WALL-MOUNT FAUCET INSTALLATION

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series

installation instructions WC Frame 1180mm with Dual Flush Cistern

caroma marc newson wall basin mixer

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Installing Brackets to Minimize Distortion in Your SMART Board 685ix Interactive Whiteboard System s Projected Image

ICU TRACKLESS SLIDING DOOR

T A P N T W I S T INSTALLATION GUIDE

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS

Privacy Wall Glass Selections - Polished Edge Slider Door

Installation Instructions

935 RODA VINESSE NEED INSTALLATION HELP? DOUBLE ROLLERS FRAMELESS DOOR INSTALLATION INSTRUCTIONS QCI XX/XX/XXXX. Call BASCO ( )

Installation Instructions for Converting Hinging on Roll-In Refrigerators

This instruction manual is an in-depth look and explanation of how to assemble and install the Murphy Bed properly and efficiently.

P a r k c o n s o l e s i n k a s s e m b l y i n s t r u c t i o n s

IMPORTANT WARNINGS AND CAUTIONS!

Assembly Instructions for Model: VMPR1

PRODUCT GUIDE Aluminum Patio Doors (JPG004)

Operation Manual Panel Mounting Gas Pressure Regulators

Transcription:

Flash Shower Valve Rough With Screwdriver Stops Thank you for selecting American-Standard... the benchmark of fine quality for over 0 years. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. INSTALLATION INSTRUCTIONS RECOMMENDED TOOLS Phillips Screwdriver Flat Blade Screwdriver Tubing Cutter Adjustable Wrench Channel Locks Plumbers' Putty or Caulking ROUGHING-IN DIMENSIONS n To assure proper positioning in relation to wall, note roughing-in dimensions. mm 68 mm (6-5/8") FINISHED WALL 7/8" TO " ( TO 50 mm) OR /" NPT OR /" NPT CPVC /" NPT 50 mm (5-7/8") 89 mm (-/") /" STUB OUT /" STUB OUT 0 mm (-/") PLASTER GUARD 0 mm (") -/" MAX. (69 mm) -/" MIN. (5 mm) OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65'' AND 78'' 6 mm 66 mm (6-/") (ASTM F807-) (ASTM F960) 6 mm (ASTM F807-) (ASTM F960) 66 mm (6-/") TOP OF TUB RIM BOTTOM OF TUB " (0 mm) /" NPT NOTE: TO AVOID SHOWER RISE OR OTHER RELATED ISSUES, DO NOT USE PEX CONNECTIONS ON ANY OF THE. Product names listed herein are trademarks of AS America, Inc. AS America, Inc. 08 - -

STANDARD WALL INSTALLATION n See Roughing-in diagram before starting. n Remove the PLASTER GUARD (8) for proper installation. n Mount VALVE BODY to cross brace (" X ") with-in wall. Use wood screws to secure VALVE BODY to brace. n Connect HOT and COLD water supplies per connection method of selected valve. n Connect RISER PIPE () to VALVE BODY () top outlet marked UP. n Connect TUB FILLER PIPE () to bottom outlet. n Cap off shower pipe () and tub filler pipe (5). n With TEST CAP (7) in place and BONNET NUT (6) installed securely, turn on water supplies and check for leaks. n Remove cap to flush the water through shower pipe. n Remove cap 5 to flush the water through tub filler pipe. n Install PLASTER GUARD (8) back onto the valve. Only remove PLASTER GUARD (8) when ready to install trim Kit. n Finished wall should allow for a " diameter opening (Use PLASTER GUARD for guidance) n Screw driver stops are primarly used to shut water off. To shut HOT or COLD water using a flat head screw driver, turn the head of the screw vertically. And to turn the water back on, turn the screw horizontally. NOTE: Cross flow can occur, if hot and cold pressures are not equal during testing. For this situation purchase FLUSH PLUG (M95) separately. See section for test procedures. : After valve installation, inspect the VALVE BODY for any debris. It can damage Pressure Balance Valve cartridge. NOTE: For back to back installation, follow steps mentioned above. Reversal of Hot/Cold water supplies is accomplished by rotating cartridge (supplied with trim) 80 during installation. SIDE VIEW CROSS BRACE -/" (00 mm) 7/8" TO " ( mm to 50 mm) 6 COLD WOOD SCREWS HOT 7 x Cross Brace " (0 mm) SCREW DRIVER 8 -/" MAX. (69 mm) -/" MIN. (5 mm) NOTE: TO AVOID SHOWER RISE OR OTHER RELATED ISSUES, DO NOT USE PEX CONNECTIONS ON ANY OF THE. 5 - -

THIN WALL INSTALL n See Roughing-in diagram before starting. n Finished wall should allow for a -/" diameter opening (Use PLASTER GUARD for guidance). n Remove PLASTER GUARD (8), rotate 90 counter clockwise and install the two screws. (Thin wall text should be on top) n Use SELF-CENTERING HOLE GUIDES (9) as a guide for thin wall install. n LOCKING SCREW (0) keeps valve in place when installing. Completely Thread LOCKING SCREW (0) onto PLASTER GUARD (8). n During the installation, make sure to position the Locking feature screw as shown in Figure A below. Once the valve is positioned on the Thin Wall, turn counterclockwise as shown in Figure B to secure VALVE BODY () in place. n Connect HOT and COLD water supplies per connection method of selected valve. n Connect RISER PIPE () to VALVE BODY () top outlet marked UP. n Connect TUB FILLER PIPE () to bottom outlet. n Cap off shower pipe () and tub filler pipe (5). n With TEST CAP (7) in place and BONNET NUT (6) installed securely, turn on water supplies and check for leaks. n Remove cap to flush the water through shower pipe. n Remove cap 5 to flush the water through tub filler pipe. n Screw driver stops are primarly used to shut water off. To shut HOT or COLD water using a flat head screw driver, turn the head of the screw vertically. And to turn the water back on, turn the screw horizontally. NOTE: Cross flow can occur, if hot and cold pressures are not equal. For this situation purchase FLUSH PLUG (M95) separately. See section for test procedures. : After valve installation, inspect the VALVE BODY for any debris. It can damage Pressure Balance Valve cartridge. NOTE: For back to back installation, follow steps mentioned above. Reversal of Hot/Cold water supplies is accomplished by rotating cartridge (supplied with trim) 80 during installation. SIDE VIEW Fig. A 9 8 0 Hex Wrench mm 0 COLD -/" 7 Fig. B HOT 6 0 5 UNLOCK LOCK - -

TEST PROCEDURES FOR FLUSH PLUG (SOLD SEPARATELY) n Unthread BONNET NUT (). n Remove TEST CAP () and install FLUSH PLUG (). n Rotate FLUSH PLUG () so opening for inlet (HOT or COLD) directs water flow to selected outlet (SHOWER or TUB). n Secure FLUSH PLUG () by tightening BONNET NUT (). n Check for leaks and flush lines. n Repeat steps above to Test/Flush atlernate flow paths. n Upon completion, unthread BONNET NUT (). Remove FLUSH PLUG (), replace with TEST CAP (), and tighten BONNET NUT (). SERVICING n To replace SCREW DRIVER STOP (), unthread it counterclockwise using the hex wrench. n Replace the unit with a new SCREW DRIVER STOP (). - -

Flash Shower Valve Rough With Screwdriver Stops MODEL NUMBERS M9705-0070A FIXATION RING KIT 0505-0070A /" SWEAT PLUG M9705-0070A LOCKING CAM SCREW KIT M9705-0070A SCREWDRIVER PURCHASED SEPARATELY M9705-0070A FIXATION RING KIT M9705-0070A LOCKING CAM SCREW KIT M9705-0070A SCREWDRIVER M95805-0070A DEEP ROUGH-IN KIT HOT LINE FOR HELP For toll-free information and answers to your questions, call: (800) -90 Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 0:00 a.m. to :00 p.m. EST IN CANADA -800-87-069 (TORONTO -905-06-09) Weekdays 8:00 a.m. to 7:00 p.m. EST IN MEXICO 0-800-89-00 Product names listed herein are trademarks of AS America, Inc. AS America, Inc. 08 M95-0070A FLUSH PLUG - 5 -