Installation- and user handbook. Pulse-out module

Similar documents
Mains operated UNILOG 300

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

IB6 Series Solid-State Isolation Relay

Installation guide 877 FDI Field Display & Interface

CEC VIBRATION TRANSMITTER

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Installation guide 971 SmartRadar LTi

Technical Description. DCF77 Receiver-Module 4460

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

33609/J Limiter/Compressor

Installation, Operation and Maintenance Manual

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

dmx2pwm 9 channel dimmer setup manual

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SET Installation and Operating Instructions. Level switch for two sensors

PU202 Level converter & encoder signal generator without potential separation

BC145 SIGNAL ISOLATOR BOARD

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Preliminary. MM7100 High-Voltage SPST Digital-Micro-Switch. Product Overview PRELIMINARY DATA SHEET, SEE PAGE 11 FOR DETAILS

Installation guide 873 SmartRadar Control Unit & Antenna Unit

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

731A seismic accelerometer and P31 power unit/amplifier Operating guide

OPTITEMP TT 20 Technical Datasheet

RADIOBAND V3 Programming & Installation Manual

MFJ ENTERPRISES, INC.

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Model: 3283N 3283N. Demand Control Module (Interface with Utility Pulse Meter) FEATURES: APPLICATIONS:

07/2015. Instruction Manual

MANUAL. Electrostatic Field Meter EFM 235 / 255. System Prof. Dr.-Ing. Hans Kleinwächter

P331-2 set ESD generator (IEC )

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Copyright 2014 by Minarik Drives

HO118 Binning Interface User Manual * * Version 02. User Manual. Test & Measurement

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

With Audible Detect Signal

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

M-Bus Master MultiPort 250L Installation and User Guide

BROADBAND LINEAR AMPLIFIER Model P150

5000 series Signal Isolation

Cross-Connect Interface

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Inductive Loop Detector

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Agilent AEDA-3300 Series Ultra Miniature, High Resolution Incremental Kit Encoders Data Sheet

F4-04DA-1 4-Channel Analog Current Output

WALTx-2 Instruction Manual Weatherproof Volume Control

Application Note (Revision NEW) Original Instructions. EMI Control in Electronic Governing Systems

1-830 SERIES DISPLACEMENT TRANSMITTER

MODEL: M2DYS SEN TRONIC AG

Service Information System

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

RMO500 M I C R O O H M M E T E R

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Model MHz Arbitrary Waveform / Function Generator

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

USER S MANUAL. C41 VARIABLE SPEED CONTROL Rev. 2 User manual Rev. 1

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

DIGITAL DIRECTION SENSING MOTION DETECTOR MANUAL

MANUAL. Electrostatic Field Meter EFM 120. System Prof. Dr.-Ing. Hans Kleinwächter

RS-485 HUB GT for Profibus, Sinec L2, Bitbus, etc. Article No S-485-HUBGT-230-xx-x. Operation and Installation Manual

RIO1S. Relay / Input / Output Transformer-Balanced Module. Features

VOLTAGE DETECTING SYSTEMS

Fiber Laser Terminal Operating Manual

Voltage Transient Emission Test

V1.3. TBLC08 50mH AC-LISN TBLC08

for authorized workshops

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

PG Interface Card "OPC-E2-PG"

OVA-50 Optical Variable Attenuator User s Manual

AN4876 Application note

Fibo-Box V3 with optocoupler board

Model 416A Gate and Delay Generator Operating and Service Manual

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

LED LINE FIX LUGA 2016

Specification for Lightning Sensor

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

Safety Information (Attach ed at the upper cover of t his product) Safety Warning (Attached on the output fiber isolato r & collimator) Figure 1 Laser

200B Clipper Module User Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

GPS Evaluation Kit EVA1084-A

Model EMIT3 Emitter Installation & Operation(REV 00) ATTENTION

Transcription:

Installation- and user handbook

All rights reserved. Copyright 2015 Wigersma & Sikkema B.V., NL-6980 AC Doesburg All the figures and descriptions in this installation, operating and maintenance manual have been compiled only after careful checking. Despite this, however, the possibility of errors cannot be completely eliminated. Therefore, no guarantee can be given for completeness or for the content. Also, the manual cannot be taken as giving assurance with regard to product characteristics. Furthermore, characteristics are also described that are only available as options. The right is reserved to make changes in the course of technical development. We would be very grateful for suggestions for improvement and notification of any errors, etc. With regard to extended product liability the data and material characteristics given should only be taken as guide values and must always be individually checked and corrected where applicable. This particularly applies where safety aspects must be taken into account. Further support can be obtained from the branch or representative responsible for your area. The address is printed on the back of this manual or simply enquire at Wigersma & Sikkema B.V. Passing this manual to third parties and its duplication, in full or in part, are only allowed with written permission from Wigersma & Sikkema B.V. The guarantee becomes invalid if the product described here is not handled properly, repaired or modified by unauthorized persons or if replacement parts are used which are not genuine parts from Wigersma & Sikkema B.V. Preface This handbook provides important information. Read this handbook carefully. In this handbook various notes and warnings are marked with symbols. Read them carefully and take any measures necessary. The symbols used have the following meanings: NOTE Suggestions and advice to make it easier to complete tasks. ATTENTION A note that draws the user s attention to possible problems. WARNING If the action is not correctly completed, data or settings can be lost. ESD A note that draws the user s attention to measures that must be taken e.g. for electrostatic discharge. DDNN102GHGB /07-2015/Rev. 3 1

Table of Contents Preface... 1 1 Introduction... 2 2 Installation... 3 2.1 Placing the module... 3 2.2 Connection with external devices... 3 3 Settings and indicators... 4 4 Maintenance... 6 5 Technical specification... 6 1 Introduction The pulse-out module is constructed with 4 configurable and galvanically isolated pulse outputs constructed with a solid state relay. A solid state relay does not experience contact bounce and has in principle an unlimited operational lifetime. The pulse outputs can switch both direct current and alternating current. All 4 outputs are also galvanically isolated from each other. With jumper settings the pulse outputs can be coupled to two external pulse contacts or the two internal pulse outputs of UNILOG 300. It is also possible to arrange several pulse outputs parallel so that the same pulse can be sent galvanically isolated to multiple systems. All signals are provided with indicators so that the function and configuration can be easily and rapidly checked. Order number NN2671. <125 V AC or DC <100 ma Jumper field Pulse output 1 OUT 1 Jumper set OUT 1 to INT 1 INT 1 Pulse output 2 Pulse output 3 Pulse output 4 OUT 2 EXT 1 Jumper set OUT 3 to OUT 2 OUT 3 INT 2 Jumper set OUT 2 to off OUT 4 EXT 2 Figure 1. Schematic representation of functions for the pulse-out module. DDNN102GHGB /07-2015/Rev. 3 2

2 Installation 2.1 Placing the module ESD Electrostatic discharges (ESD) can cause damage to internal electrical components if you do not take preventative measures. ESD is caused by static electricity and the damage caused is usually permanent. WARNING Inside the device in which the pulse-out module is to be placed there are parts that are connected with the main power supply. Disconnect the mains power supply temporarily during any work. See the user handbook for the device in which the pulse-out module is to be placed. Depending on the device in which the pulse-out module shall be place, the pulse-out module must be installed as follows: All models UNILOG 300 with mains supply of type N33, N34 or N35 (see type plate left exterior): there are 1 or 2 open connections on the first PCB. Place the pulse-out module on an open connection. ISC230B (see type plate left exterior): there are 3 connections. Other modules may be present. Place the pulse-out module on an open connection. 2.2 Connection with external devices The wiring for connecting with external devices is fed through a free cable gland from the UNILOG 300 or ISC230B and connected to one or more screw connectors to the outputs OUT 1 to OUT 4 of the pulse-out module. There are no specific demands for the wiring except that it is suitable for a watertight led trough by the cable gland. The possible polarity of the connection with the external devices does not need to be taken into account. Maximum values of the signal of the external devices: - 125 V direct or alternating current - 100 ma. DDNN102GHGB /07-2015/Rev. 3 3

3 Settings and indicators Figure 2. Jumpers and led indicators 1. Screw terminals of the 4 pulse outputs OUT 1 to and including OUT 4 2. Led indicators for the function of the 4 pulse outputs OUT 1 to and including OUT 4 3. Jumper field for coupling a pulse output to an internal or external pulse signal 4. Led indicators for the function of an internal or external pulse signal Calibrating the jumpers The pulse outputs on the pulse-out module are coupled by means of jumper settings to an internal or external pulse signal: - When the pulse-out module is placed in an ISC230B: o The two external pulse signals that are connected to the pulse inputs IN1 and IN2 of the ISC230B (screw terminals 3 to 6). A pulse signal at input IN1 shall emit an EXT1 pulse signal and a pulse signal at input IN2 shall emit an EXT2 pulse signal. This is easy to follow through, for example, shorting the IN1 screw terminal of the ISC230B with a wire will light up the led indicator EXT1. The same applies for the IN2 input and the EXT2 led indicator. - When the pulse-out module is placed in a UNILOG 300: o The two external pulse signals that are connected to the pulse inputs IN1 and IN2 of the UNILOG 300 (screw terminals 3 to 6). A pulse signal at input IN1 shall emit an EXT1 pulse signal and a pulse signal at input IN2 shall emit an EXT2 pulse signal. This is easy to follow through, for example, shorting the IN1 screw terminal of the UNILOG 300 with a wire will light up the led indicator EXT1. The same applies for the IN2 input and the EXT2 led indicator. o The two internal pulse outputs of the UNILOG 300. A pulse signal from pulse output 1 of UNILOG 300 shall emit an INT1 pulse signal and a pulse signal from pulse output 2 of UNILOG 300 shall emit an INT2. This is clearly visible by means of the led indicators INT1 and INT2. DDNN102GHGB /07-2015/Rev. 3 4

Consequently the pulse signals INT1, EXT1, INT2 and EXT2 can be coupled with a jumper to the corresponding pulse outputs OUT1, OUT2, OUT3 and OUT4: - With a jumper in top position no coupling is present, the pulse output is disabled; see below for example in which all pulse outputs are disabled. This is the standard factory setting. - With a jumper in in the lowest position the pulse output is coupled and active, see for example the illustration below whereby the pulse output OUT2 is enabled and with the pulse signal EXT1 and the pulse output OUT4 is enabled with the pulse signal EXT2. The functioning of the jumper setting is easy to check; when indicator EXT1 lights up also led indicator OUT2 lights up. - If multiple pulse outputs are needed for the same pulse signal, then a horizontally placed jumper in the top position can forward the pulse signal through to a second pulse output. See for example below whereby an extra connection is made for the pulse signal EXT1 also using the pulse output OUT1 DDNN102GHGB /07-2015/Rev. 3 5

4 Maintenance The pulse-out module does not need maintenance. For maintenance of the devices in which the module is placed refer to the user manual of the devices in question. 5 Technical specification Pulse outputs 4, optical solid state output, independent galvanically isolated Max contact signal 125 V AC and 100 ma eff On resistance < 30 Ω EMC Protection 400 W transient suppression Max. output frequency 100 Hz DC 50 % Operating temperature - 25 C to + 55 C DDNN102GHGB /07-2015/Rev. 3 6

Wigersma & Sikkema B.V. Postbox 109 6980 AC Doesburg Leigraafseweg 4 6983 BP Doesburg TEL: +31 (0) 313 47 19 98 FAX: +31 (0) 313 47 32 90 info@wigersma-sikkema.com www.wigersma-sikkema.com DDNN102GHGB/07-2015/Rev. 3