Technical Documentation

Similar documents
Technical Documentation MOT-114-P

W.E.ST. Elektronik GmbH

W.E.ST. Elektronik GmbH

Technical Documentation PAM-190-P

Proportional amplifier type EV22K5

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Continental Hydraulics Installation Manual CEM-PA-A

Continental Hydraulics Installation Manual CEM-RA-A

RT-5005/5006/5007/5008

Technical Documentation PID-131-U

Electronic amplifier type EV1D

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Technical Documentation POS-323-P

Valve amplifier for proportional pressure valves

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Digital amplifier for proportional valves PEM XD

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Continental Hydraulics Installation Manual CEM-AA-B

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Amplifier / controller electronics

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

IF30. User's manual. Description. Table of contents IF30

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Box chopper amplifier BOE

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Proportional amplifier type EV1M3

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Drive Electronics pq11

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Operating instructions Fail-safe delay timer AZS About this document. Content

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

Coils & Electronic Controls

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

ELECTRONIC REGULATOR FOR OPEN LOOP

Smart Power Relay E I...

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

W.E.ST. Elektronik GmbH

Proportional amplifier type EV1M3

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

DENISON HYDRAULICS Proportional Pressure Control Valves

Analog amplifier RA. RE Edition: Replaces:

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

PU202 Level converter & encoder signal generator without potential separation

Installation and Operating Instructions for Phase Demodulator Type _.2

EY-EM 527: Remote I/O module, ecolink527

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Functional data Factory settings Variable Settings

Drive electronics pq11

RA / /6. Replaces: Table of contents RA /06.98

Torque Sensor Series 3000 and Series 4000

Operating Instruction

Industrial motor controller for brushed DC motors 24 VDC

RMO500 M I C R O O H M M E T E R

Technical data. General specifications. Measurement range min max. 360

Industrial motor controller for brushed DC motors 24 VDC

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical Documentation

Operating Instructions

Electronic regulator for PWM controlled proportional solenoid valves FABER -

Pulse Scaler for DIN Rail Attachment

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Accessories Power Amplifiers

ECM3 EARTH CONTINUITY RELAY

Proportional Directional Control Valves Size 6

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Electronic Circuit Breaker ESS1 for System SVS1

AxCent Servo Drive A25A100

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Copyright 2016 by Brüel & Kjær Vibro GmbH, D Darmstadt

US2, US4, US6 Electronic step controllers

AxCent Servo Drive A50A100

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Installation / Monitoring Technique

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

Analog Servo Drive 20A20

Electronic Air / Fuel Ratio Control System

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

MDC V, 2A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

02/11/2015

DEIF A/S. Insulation monitor. Type SIM-Q

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Hydraulic Valve Interface Products

RT100 Multi-axis Joystick Controller. RunnTech

DENISON HYDRAULICS Multi-Function Proportional Valve Dual Driver ( Encapsulated )

Ref /b VARMECA 10 Variable speed motors and geared motors. Parameter-setting manual

Level Limit Switch nivotester FTL 325 P

MINI-PS AC/24DC/1.3

Transcription:

Technical Documentation PROAM-21 Power amplifier for directional valves Grundlage der Funktionsbeschreibung und zur Prüfung der Module (keine Produktdokumentation). AMCA HYDRAULIC FLUID POWER B.V. P.O.BOX 18, 9790 AA Ten Boer Tel. +31 (0)50 3023577 B.Kuiperweg 33, 9792 PJ Ten Post Fax. +31 (0)50 3021226 The Netherlands email: sales@amca-nl.com homepage: www.amca-nl.com

CONTENTS 1 General Information... 3 1.1 Order number... 3 1.2 Scope of supply... 3 1.3 Accessories... 3 1.4 Symbols used... 4 1.5 Safety instructions... 5 2 Characteristics... 6 2.1 Device description... 7 3 Use and application... 8 3.1 Installation instructions... 8 3.2 Typical system structure... 9 3.3 Method of operation... 9 3.4 Commissioning... 10 4 Technical description... 11 4.1 Input and output signals... 11 4.2 LED definitions... 11 4.3 Circuit diagram... 12 Typical cabling... 13 4.5 Technical data... 14 5 Adjustment... 15 5.1 Elements... 15 5.2 Start-up... 16 6 Appendix... 17 6.1 Failure monitoring... 17 6.2 Troubleshooting... 17 Page 2 of 18

1 General Information 1.1 Order number - for directional valves (max output current: 0,8 A and 1,6 A) 1.2 Scope of supply The scope of supply includes the module plus the terminal blocks which are a part of the housing. The Profibus plug, interface cables and further parts which may be required should be ordered separately. 1.3 Accessories Page 3 of 18

1.4 Symbols used General information 11 Safety-related information Page 4 of 18

1.5 Safety instructions Please read this document and the safety instructions carefully. This document will help to define the product area of application and to put it into operation. Additional documents (WPC-300 for the start-up software) and knowledge of the application should be taken into account or be available. General regulations and laws (depending on the country: e. g. accident prevention and environmental protection) must be complied with. 11 These modules are designed for hydraulic applications in open or closed loop control circuits. Uncontrolled movements can be caused by device defects (in the hydraulic module or the components), application errors and electrical faults. Work on the drive or the electronics must only be carried out whilst the equipment is switched off and not under pressure. This handbook describes the functions and the electrical connections for this electronic assembly. All technical documents which pertain to the system must be complied with when commissioning. 11This device may only be connected and put into operation by trained specialist staff. The instruction manual must be read with care. The installation instructions and the commissioning instructions must be followed. Guarantee and liability claims are invalid if the instructions are not complied with and/or in case of incorrect installation or inappropriate use. 11CAUTION! All electronic modules are manufactured to a high quality. Malfunctions due to the failure of components cannot, however, be excluded. Despite extensive testing the same also applies for the software. If these devices are deployed in safety-relevant applications, suitable external measures must be taken to guarantee the necessary safety. The same applies for faults which affect safety. No liability can be assumed for possible damage. Further instructions The module may only be operated in compliance with the national EMC regulations. It is the user s responsibility to adhere to these regulations. The device is only intended for use in the commercial sector. When not in use the module must be protected from the effects of the weather, contamination and mechanical damage. The module may not be used in an explosive environment. To ensure adequate cooling the ventilation slots must not be covered. The device must be disposed of in accordance with national statutory provisions. Page 5 of 18

2 Characteristics This module is used for the control of proportional valves with one or two solenoids. Various adjustable parameters enable an optimized adaptation to the respective valve. This power amplifier is inexpensive and a space-saving solution. The amplifier is controlled by different voltages or current input signals. The output current is closed loop controlled and therefore independent from the supply voltage and the solenoid resistance. Ramps, MIN and MAX and PWM-frequency are adjustable via potentiometer Typical applications: Control of proportional valves Features Power amplifier for proportional directional valves Internal controlled by a modern microcontroller Compact housing Adjustment via potentiometer MIN-, MAX-, RAMP- and PWM-frequency adjustment via potentiometer Current range (per DIL switch): 0,8 A and 1,6 A Page 6 of 18

2.1 Device description Page 7 of 18

3 Use and application 3.1 Installation instructions This module is designed for installation in a shielded EMC housing (control cabinet). All cables which lead outside must be screened; complete screening is required. It is also a requirement that no strong electro-magnetic interference sources are installed nearby when using our open and closed loop control modules. Typical installation location: 24 V control signal area (close to PLC) The devices must be arranged in the control cabinet so that the power section and the signal section are separate from each other. Experience shows that the installation space close to the PLC (24 V area) is most suitable. All digital and analogue inputs and outputs are fitted with filters and surge protection in the device. The module should be installed and wired in accordance with the documentation bearing in mind EMC principles. If other consumers are operated with the same power supply, a star-connected ground wiring scheme is recommended. The following points must be observed when wiring: The signal cables must be laid separately from power cables. Analogue signal cables must be screened. All other cables must be screened if there are powerful interference sources (frequency converters, power contactors) and cable lengths > 3 m. Inexpensive SMD ferrites can be used with high-frequency radiation. The screening should be connected to PE (PE terminal) as close to the module as possible. The local requirements for screening must be taken into account in all cases. The screening should be connected to at both ends. Equipotential bonding must be provided where there are differences between the connected electrical components. With longer lengths of cable (>10 m) the diameters and screening measures should be checked by specialists (e. g. for possible interference, noise sources and voltage drop). Particular care is required with cables of over 40 m in length the manufacturer should be consulted if necessary. A low-resistance connection between PE and the mounting rail should be provided. Transient interference is transmitted from the module directly to the mounting rail and from there to the local earth. Power should be supplied by a regulated power supply unit (typically a PELV system complying with IEC364-4-4, secure low voltage). The low internal resistance of regulated power supplies gives better interference voltage dissipation, which improves the signal quality of high-resolution sensors in particular. Switched inductances (relays and valve coils) connected to the same power supply must always be provided with appropriate overvoltage protection directly at the coil. Page 8 of 18

3.2 Typical system structure This minimal system consists of the following components: (*1) proportional valve (*2) hydraulic cylinder (*3) power amplifier (*4) interface to PLC with analogue and digital signals 3.3 Method of operation Page 9 of 18

3.4 Commissioning Step Installation Switching on for the first time Pre-parameterization Control signal Switching on the hydraulics Activating ENABLE Optimize controller Task Install the device in accordance with the circuit diagram. Ensure it is wired correctly and that the signals are well shielded. The device must be installed in a metal protective housing (control cabinet or similar). Ensure that no unwanted movement is possible in the drive (e. g. switch off the hydraulics). Connect an ammeter and check the current consumed by the device. If it is higher than specified, there is an error in the cabling. Switch the device off immediately and check the cabling. Now set up the following parameters (with reference to the system design and circuit diagrams): The output current and the typical input function (DIL switches) Check the control signal with a voltmeter. The control signal (the current of the solenoid is within the range of 0... 1, 6 A). In the actual status it should have approximately 0 A. The hydraulics can now be switched on. Since the module is not yet generating a signal the drive should be at a standstill or drift slightly (leave its position at a slow speed). CAUTION! The drive can now leave its position and move to an end position at full speed. Take safety measures to prevent personal injury and damage. The hydraulic axis can be moved over the analogue input value. Now optimize the remaining parameters (MIN function and RAMP time) according to your application and your requirements. Page 10 of 18

4 Technical description 4.1 Input and output signals Connection PIN 7 PIN 8 Connection PIN 9/10 Supply Power supply (see technical data) 0 V (GND) Power supply (ground). Attention, PIN 8 is connected with PIN 11 internal. PIN 11 is used as the GND potential for the command and feedback signals. Analogue signals Command (input) signal (W), range +/-100 % corresponds with +/-10 V or 4 20 ma. PIN 13 Input resistor (500 Ohm) used for 4 20 ma. PIN 13 have to be connected with PIN 9. PIN 11 PIN 12 PIN 1/2 PIN 3/4 Connection PIN 15 PIN 5 0 V (GND) for the signal inputs Reference output voltage (8 V). Current controlled PWM outputs for solenoid A and B. Digital inputs and outputs Enable Input: This digital input signal initializes the application, fault messages are reset. The output and the READY signal will be activated. READY output: ON: No internal or external errors are detected OFF: ENABLE (PIN 15) is deactivated or an error is detected. 4.2 LED definitions LEDs GREEN Description of the LED function Identical to the READY output. OFF: No power supply or ENABLE is not activated ON: System is ready for operation Flashing: Error detected (e.g. valve solenoid or 4 20 ma). Not active when SENS = OFF. YELLOW A/B ON: related solenoid is activated. OFF: solenoid not activated. Page 11 of 18

4.3 Circuit diagram Page 12 of 18

4.4 Typical cabling Joystick PIN 12 8V PIN 10 +In PIN 9 -In PIN 11 GND +/- 10 V (SPS / PLC) or +/- 8 V PIN 10 +In PIN 9 -In PIN 11 GND SWITCH S1 5 4 3 ON OFF ON ON ON OFF SWITCH S1 5 4 3 OFF OFF OFF OFF OFF ON +/- 4V ( 8 V) +/- 5V (10 V) +/- 10 V +/- 8 V 1 5 2 6 3 7 4 8 Magnet B Solenoid B Magnet A Solenoid A 12 V / 24 V 0V Spannungsversorgung Power Supply SWITCH S1 2 1 OFF ON OFF ON 0,8 A 1,6 A PE PE Potentiometer PIN 12 8V PIN 10 +In PIN 9 -In PIN 11 GND SWITCH S1 5 4 3 OFF ON OFF OFF ON ON 0...5... 10 V 0...4... 8 V 9 10 11 0V 12 13 14 15 16 4... 20 ma (SPS / PLC) PIN 10 +In SWITCH S1 5 4 3 Schirm / Screen PIN 9 -In PIN 13 ON OFF OFF ON ON ON 4... 12... 20mA +/- 100% 4... 20mA 0... 100% Analoger Sollwert Analogue command signal Enable Page 13 of 18

4.5 Technical data Power supply Current consumption External fuse Reference voltage Digital inputs Input resistance Digital outputs Analogue inputs (sensor and command signals) Resolution PWM Output current PWM frequency Sample time (pressure control) Sample time (solenoid current control) Adjustments MIN [VDC] 12 30 (incl. ripple) [ma] <100 + solenoid current [A] 3 medium time lag [V]8 ( maximum 10 ma) [V] logic 0: <2 [V] logic 1: >10 [kω] 25 [V] logic 0: <2 [V] logic 1: >12 (50 ma) [V] ±10 / 0 10; 90 kω [ma] 4...20; 390 Ω [%] <0,025 [A] 0,8 or 1,6; short cut protected. [Hz] 70...130 [ms] 1 [ms] 0,167 [%] 0 60 (0 = pre-adjusted) MAX [A] 0,7 1,6 [A] 0,4 0,8 (pre-adjusted) RAMP [s] 0,05 15 (0,05 = pre-adjusted) PWM Frequency [Hz] 70 130 (130 = pre-adjusted) Housing Snap-On Module EN 50022 Polyamide PA 6.6 Combustibility class V0 (UL94) Protection class [IP] 20 Temperature range [ C]-20 60 Storage temperature [ C]-20 70 Humidity [%] <95 (not condensing) Connections 4 x 4pol. screw terminals PE: direct via DIN rail EMC EN 61000-6-2: 8/2002 EN 61000-6-3: 6/2005 Page 14 of 18

5 Adjustment 5.1 Elements 11 Location of the potentiometer Front: P1 = MINA P2 = MINB P3 = MAXA P4 = MAXB Elements inside the module: P5 = PWM frequency P6 = RAMP time Input signal selection DIL S1 S1.3 and S1.4 and S1.5 S1.5=OFF S1.4=OFF S1.3=OFF ±10 V input S1.5=OFF S1.4=OFF S1.3=ON ±8 V input S1.5=OFF S1.4=ON S1.3=OFF 0 5 10 V input (set in factory) S1.5=OFF S1.4=ON S1.3=ON 0 4 8 V input S1.5=ON S1.4=OFF S1.3=OFF 4 12 20 ma for ± 100% S1.5=ON S1.4=OFF S1.3=ON ±4 V input (joystick) S1.5=ON S1.4=ON S1.3=OFF ±5 V input (joystick) S1.5=ON S1.4=ON S1.3=ON 4 20 ma for 0 100% Solenoid current selection: (both switches) S1.1 = OFF, S1.2 = OFF (up to 0,8 A) S1.1 = ON, S1.2 = ON (up to 1,6 A) Page 15 of 18

5.2 Start-up Application with typical proportional valves. Because of the type these valves have relatively great tolerances in comparison to the electronics. The adjustment can vary from valve to valve. MAX: Maximal current adjustment. The presetting is 0,8 A and/or 1,6 A if the DIL switch S2 is ON. Preset an input signal of 100 % for the respective direction of the motion. By turning the MAX-potentiometers anti-clockwise the output current is reducing and the drive becomes slower. This can be carried out separately for the respective direction of the motion. Caution: It is to be guaranteed that the maximum output current does not climb over the rated current of the valve. MIN: Zero- / deadband adjustment. The MINadjustment should be carried out after the MAX-adjustment. The presetting is 0 (fully anti-clockwise). According to valve adjustments of approx. 15 % to 35 % of the rated current are necessary. Preset a small input signal of approx. 3 % to 5 %. You increase the MIN value (rotate clockwise) continuously until the drive moves, from there you reduce the value (anti-clockwise) until the drive came to standstill again. Caution: By changing of the MAXadjustment also the MIN-adjustment changes. MAX B MIN A MIN B MAX A RAMP: The ramp time is preset on approx. 50 ms (smallest value). It is prolonged by turning clockwise up to approx. 15 s. All ramp times are identical. Caution Ramp times and simultaneously short cycle times (cycle time < ramp time) can result in a hardly understandable behaviour because all movements are carried out strongly. PWM frequency: The PWM frequency is adjustable. Preset is 130 Hz (potentiometer fully clockwise). With the adjustment of the frequency (rotate anti clockwise) the valve hysteresis can be reduced clearly. Caution: Too high dither amplitude can lead to an increased attrition. General behaviour: Power ON: After the power on the input signal is checked (4 20 ma) and the system is than activated. When ENABLE is active (ENABLE directly connected with the supply voltage) the current is activated by an internally defined ramp (smooth starting) in order to drive onto the demand value with the pre-set ramp time. ENABLE: With this switching-input the internal signal processing and the final stage are enabled. While activating the input the valve current will be driven the pre-set ramp. During the deactivation the current is disconnected immediately. Page 16 of 18

6 Appendix 6.1 Failure monitoring Following possible error sources are monitored continuously: Source Fault Characteristic Command signal PIN 9/10 4...20 ma Command signal PIN 9/10 LIM function Solenoid A PIN 3/4 Solenoid B PIN 1/2 EEPROM (at switching on) Out of range Out of range Broken wire Data error The power stage is deactivated. The power stage is deactivated. The power stage is deactivated. The power stage is deactivated. The module can be activated by saving new parameters (pressing of the SAVE Button). 6.2 Troubleshooting Initial situation is an operable status of the device and existing communication between the module and the WPC-300 program. Furthermore, the parameterization of the valve control has to be done with the assistance of the valve data sheets. The RC mode in monitor can be used to analyze faults. 11 CAUTION: If using the RC (Remote Control) mode, all safety aspects have to be checked solid. In this mode the module is actuated directly and the machine control has no influence on the module. FAULT ENABLE is active, the module does not respond, and the READY LED is off. ENABLE is active, the READY LED is flashing. CAUSE / SOLUTION Probably the power supply is disconnected or the ENABLE signal is not present. If there is no power supply there is also no communication via our operating program. If the connection to the WPC-300 exists, the power supply is also available. In this case the availability of the ENABLE signal can be checked via the monitor. The flashing READY LED indicates that a fault is detected by the module. The fault could be: No signal at the input, if 4 20 ma signal is chosen, or signal is out of range if the LIM monitoring is activated. A broken cable or incorrect wiring to the solenoids. With the WPC-300 operating program the failure can be localized directly via the monitor. Page 17 of 18

History Datum Kurzzeichen Bemerkung 25.10.2007 - - 14.03.2012 UW Neue Dokumentation für die Version 16.04.2012 UW Fehler in der Dokumentation beseitigt. Page 18 of 18