Information & Instructions

Similar documents
BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

11Beamage-3. CMOS Beam Profiling Cameras

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

USER MANUAL. 11Beamage-3 USB 3.0 Beam Profiling Camera

BeamPro 3.0 Series User Manual Revision WARRANTY

Beamage User Manual Revision 10 0

BEAM PROFILING CAMERAS

DataRay Software. Feature Highlights. Beam Profiling Camera Based WinCamDTM Series. Software Aperture/ISO measurements

3.4 Introduction to Scanning-Slit Profilers

Coherent Laser Measurement and Control Beam Diagnostics

3.4 Introduction to Scanning-Slit Profilers

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Mach 5 100,000 PPS Energy Meter Operating Instructions

Technical Benefits of the

Swept-Field User Guide

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

LSM 710 Confocal Microscope Standard Operation Protocol

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc.

Beam Analysis NanoScan 2. Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement. Capabilities.

LSM 780 Confocal Microscope Standard Operation Protocol

NanoScan 2s Standard Version Scanning Slit Beam Profiler For High Accuracy Dimensional Measurement

Reference and User Manual May, 2015 revision - 3

ThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Hartmann Sensor Manual

Laser Speckle Reducer LSR-3000 Series

Improvement of terahertz imaging with a dynamic subtraction technique

4.5.1 Mirroring Gain/Offset Registers GPIO CMV Snapshot Control... 14

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

White Paper: Modifying Laser Beams No Way Around It, So Here s How

Beam Diagnostics Introduction

Laser Damage Threshold System For Final Optics Testing

The operation manual of spotlight 300 IR microscope

Zeiss 880 Training Notes Zen 2.3

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

Instruction Manual for HyperScan Spectrometer

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Atlantic. Industrial High Power Picosecond Lasers. features

Gentec Electro-Optics, Inc

Microscopy from Carl Zeiss

Beamage-M2 User Manual Revision A i WARRANTY

Power. Warranty. 30 <1.5 <3% Near TEM ~4.0 one year. 50 <1.5 <5% Near TEM ~4.0 one year

1.2 BeamTrack Power / Position / Size Sensors

Be aware that there is no universal notation for the various quantities.

Determination of the Focal Width with the Focal Width Script

Gentec Electro-Optics, Inc

IBIL setup operation manual for SynerJY software version

Good things do come in small packages - high sensitivity and image quality

Operating longitudinal mode Several Polarization ratio > 100:1. Power. Warranty. 30 <1.5 <5% Near TEM ~4.0 one year

Technical Datasheet. Model AX50 / AX100 / AX200

Prosilica GT 1930L Megapixel machine vision camera with Sony IMX CMOS sensor. Benefits and features: Options:

Portable Multi-Channel Recorder Model DAS240-BAT

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Gigashot TM FT High Energy DPSS Laser

Zeiss 780 Training Notes

Mach 5 User s Manual Revision 2.2 1

Leica SPEII confocal microscope. Short Manual

Digital Portable Overhead Document Camera LV-1010

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Instructions for the Experiment

Apples to Apples: Which Camera Technologies Work Best for Beam Profiling Applications, Part 3: Beam Aperturing Methods

Leica TCS SP8 Quick Start Guide

WALLY ROTARY ENCODER. USER MANUAL v. 1.0

RENISHAW INVIA RAMAN SPECTROMETER

Compact high-speed cameras with high light sensitivity

SVAN A DESCRIPTION OF GROUND VIBRATION FUNCTION. SVANTEK Sp. z o.o. WARSAW, July 2014 SVANTEK

AgilEye Manual Version 2.0 February 28, 2007

Renishaw InVia Raman microscope

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Tribometrics. Version 2.11

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

USB Line Camera 8M. Coptonix GmbH

Operating Rausch ScanCam within POSM.

3DExplorer Quickstart. Introduction Requirements Getting Started... 4

Software Manual for the Economy LBIC Demo

Miniature collimator for POF fiber: large aperture Model 011-TU2

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

PRODUCT OVERVIEW FOR THE. Corona 350 II FLIR SYSTEMS POLYTECH AB

Guide to Confocal 5. Starting session

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Line beam for fast, accurate measuring of height and width

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

LSM 510 Meta Training Notes

Figure 1 The Raith 150 TWO

Tenor System. 8-Channel Data Logger. User Manual, version 2.0e

Wide-Field TCSPC FLIM with bh SPC-150 N TCSPC System and Photek FGN Detector

Characterization Microscope Nikon LV150

KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017)

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Machine Vision Lyte-MV 2

Leica TCS SP8 Quick Start Guide

A discussion of Laser Beam Profiling and the subject of Accuracy

Introduction. Note. This is about what happens on the streets.

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Transcription:

KEY FEATURES 1. USB 3.0 For the Fastest Transfer Rates Up to 10X faster than regular USB 2.0 connections (also USB 2.0 compatible) 2. High Resolution 4.2 MegaPixels resolution gives accurate profile measurements of very small beams 3. Large Area Sensor 11.3 x 11.3 mm 4. ISO Compliant D4σ Definition of Diameter, Centroid, Ellipticity and Orientation are ISO 11146:2004 and 11146:2005 compliant 5. Intuitive Software Interface Easy to navigate interface, with many displays and control features: 2D, 3D and XY Displays Background Subtraction Function Unique Animate Function Gaussian Fit Semi-Log Graph 6. External Trigger To synchronize the camera with a pulsed laser Beam Tracking Divergence Animate Image Averaging Filters Subtract Background Normalize Trigger

specifications Edmund Optics Beam Profiler Sensor Technology Effective Aperture CMOS 11.3 x 11.3 mm Measurement capability Wavelength Range Camera only 350-1150 nm Pixel Count 4.2 Mega Pixels H x V 2048 x 2048 Pixel Dimension 5.5 x 5.5 μm Minimum Measurable Beam 55 μm Shutter Type Global Frame Rate RMS Noise ADC Level (User Setable) 6.2 fps @ 4.2 MegaPixels (Full Frame) 11.4 fps @ 2.1 MegaPixels (2048 x 1024) 18.6 fps @ 1.1 MegaPixels (2048 x 544) 32 fps @ 0.066 MegaPixels (256 x 256) 1000:1 (60 db) 12 bit (default) / 10 bit (option) Damage thresholds Maximum Average Power 1 W *With ND4 filter Saturation Level (1064 nm) CW: 10 W/cm 2 ; Pulsed: 300 μj/cm 2 Software Displays Display Features Beam Diameter Definitions Buffer Controls Printing and Reports 2D, 3D, XY and Beam Tracking 2D: Print Screen, Reset View, Beam Diameter 3D: Print Screen, Reset View, Top View XY: Save Data, Zoom, Gaussian Fit, Semi-Log, Cursor, FWHM, 1/e 2 Beam Tracking: Save Data, Print Screen, Reset View, Zoom D4σ (ISO compliant) 1/e 2 along crosshairs (13.5%) FWHM along crosshairs (50%) 86% effective diameter (D86) Open File, Save Current Data, Save All Data, Previous/Next Image, Clear Buffer, Animate Full Report in Print Ready Format (2D, 3D, XY, Measures, Parameters) Print Screen in BMP format (2D and 3D) Physical Characteristics Sensor Size 11.3 x 11.3 mm Sensor Area 1.28 cm 2 Dimensions (not including filter) (mm) 61 H x 81.1 W x 19.7 D Weight (head only) 138 g

Capture Controls: Start/Stop, Subtract Background File Controls: Save and Open Data Buffer Controls: View Data Offline Data Computation Software Info 1 2 3 Displays: 3D, 2D, XY Graphs and Beam Tracking Home and Setup Tabs: Set your capture parameters and get the resulting measures 1 2 3 MAIN CONTROLS The upper part of the software includes all the main controls in a ribbon format. These controls are grouped by family: Capture Controls, File Controls, Buffer Controls, M2 Controls and Data Computations. The last includes very useful filters and a normalizing function. DISPLAYS The left-hand side of the software is the display panel. Four displays are available: 3D, 2D, XY (cross-sectional graphs along the crosshairs) and Beam Tracking. The desired display is selected by clicking on the corresponding icon at the bottom of the panel. Print screen controls are available for the 3D, 2D and Beam Tracking displays. They allow the user to save an image of the current view in BMP format. HOME AND SETUP TABS The right-hand side of the software contains the Home, Setup and Data Acquisition tabs. The Home tab allows the user to select the main controls for his measurements (Beam Diameter Definition, Crosshair Center and Orientation) and displays the resulting measurements below. The Setup tab allows the user to set the measurement parameters (Exposure Time, Image Orientation and Averaging, Active Area, etc.) and the Data Acquisition tab allows the user to save measurements or Full Images and measurements, to enter the Sampling Rates and a Total Duration for the Acquisition. More tabs with advanced controls are available when clicking on the Options button in the Computations panel.

1. 3D DISPLAY The 3D display shows the actual shape of the beam. It is possible to easily zoom, pan and rotate the image. The Reset button allows the user to put the data back in its original configuration. This display also features a Print Screen button to save the latest image in BMP format. Print Screen Reset View Top View 2. 2D DISPLAY The 2D display features the crosshairs (set to the major and minor axis or along specified angles) and the measured diameters of the beam. These diameters vary with the chosen definition (4-sigma, FWHM, 1/e2, etc.) and the display can be turned ON or OFF. The Print Screen button allows the user to save a picture of the current screen in BMP format. Select Active Area Print Screen Rest View Diameter 3. XY DISPLAY The XY display plots cross-sectional graphs of the beam along the crosshairs. This display features many useful tools like zoom, cursor, and FWHM and 1/e2 level bars. It is also possible to display the graphs in semi-log format to enhance the details in the low intensity parts of the beam. Save Data Zoom Gaussian Fit Cursor FWHM 1/e2 Semi-Log Graph 4. BEAM TRACKING DISPLAY Mean: -20.427, 7.319 Last: -205.513, 624.418 Azimut: 0.006 x: 1416.259 : 152.890 y: 459.746 The Beam Tracking Display allows the user to visualize the variation of the beam s centroid position on the sensor. This display shows the latest calculated position as well as the previous ones, until the user resets the view. The display also shows the mean position of all computed values and gives information regarding position stability for both X and Y axes. This tool is great to monitor the beam pointing stability over time. 2992 um 0 um -2992 um -5632 um Number of samples : 2000/2000 0 um 5632 um Save Data Print Screen Zoom Pick Origin Point Reset View

FILTERS Filter out the noise in your beam profile by using one of the filter functions. The Edmund Optics Beam Profiler has both smoothing and despeckle filters. The Smoothing filter is a soft noise reduction method whereas the Despeckle filter is a much more aggressive spatial filter that is designed to remove speckles and noisy signals from very poor quality beam profiles. Instead of performing a 3 x 3 pixel smoothing filter with a relative weight of 20% for the central pixel and 10% for the others, the software performs a 9 x 9 pixels simple averaging, with all pixels having the same relative weight (1/81). The filter can be found in the Filters menu of the main controls. ON OFF DIVERGENCE The Divergence of a beam is defined as the increase in beam radius with propagation from the optical aperture. For most applications, a lower-divergence beam is preferable. Using the new Divergence tab in the PC Edmund Optics Beam Profiler application, this parameter can now be computed for both mains axes (X, Y) according to the ISO 11146-1:2005 and 11146-2:2005 standards. A focal lens with a known focal length is required for the measurement of the divergence. Divergent Laser Source Divergence (Θ) Focusing Lens Focal Length (l) CMOS Sensor Actual focus should fall behind camera face ACQUISITION In the Acquisition tab, the user can define a total duration for the acquisition and can specify a name and a path for his saved files. The user can either choose to save measurements only or both measurements and full images. It is possible to save the data shown in the Measure tab in a *TXT file, which includes a header that displays the custom acquisition settings above the data. Each line corresponds to a single frame. This file can be opened in a spreadsheet software such as Microsoft Excel. It is also possible to save the images associated with the measurements from the *.TXT logging file. Each image will be individually saved in a native *.BMG file. For measurements, it is possible to choose a sampling rate for the saved data. Similarly, for the full images, one can manually set a temporal interval at which the software will save the data. With these tools, the user will be able to store only the information that is useful to his work. RELATIVE POSITION In the Relative Position tab, the Setup section allows the user to select the parameter that will be considered as the origin position (0,0). Centroid (center of energy) and Peak (highest measured value) are the options. The User Define option allows the user to manually enter origin position values for both axes. It is also possible to position the origin by simply clicking with the mouse in the display. Once the origin position is determined by the user, the software calculates the difference between the coordinates of this new position and the latest computed one. The results are displayed in the Measures section. It is possible to save the data in the acquisition file if desired.

SUBTRACT BACKGROUND The background subtraction function is a necessary tool to have an accurate measurement and to abide by the ISO 11146-3:2004 standards. By taking 10 images and averaging them pixel by pixel to compute the average background map, contamination of all images can be avoided with the help of environment noise subtraction. SUBTRACT BACKGROUND Give life to your measures with the animate function. With as much as 32 images temporaily saved in the buffer, simply pressing the animation button will create a movie with any display (2D, 3D, and XY). This allows to visualize the beam while working offline and to have a recalculation process if the beam diameter definition or crosshair parameters are changed. MULTIPLE CAMERAS It is possible to use multiple Edmund Optics Beam Profiler cameras on one computer simultaneously. By running multiple PC Edmund Optics Beam Profiler instances and selecting the desired camera for each one, the user will be able to stream multiple cameras simultaneously, thus effectively monitoring all the beams and easily switching from one to another. NORMALIZE The normalize function spreads the intensity over the full range (0% to 100%). This is especially useful with low level signals or to enhance the variations in the beam. OFF ON TRIGGER For the case of pulsed laser sources, the trigger function will be useful to synchronize the system s capture rate with the source s repetition rate, especially when this one is low (<16 Hz). To be achieved, a TTL (0-5 V) or other (1.1-24 V) trigger signal can be connected to the EO Beam Profiler camera via a BNC or SMA plug. IMAGE AVERAGING The image averaging function uses a temporal filter that captures 2, 5 or as much as 10 images of the beam to create a single time averaged image with them. This process will smooth the beam fluctuations that can occur over time when working with unstable laser sources. ACTIVE AREA (ROI) Increase the data transfer rate by reducing the area of the sensor that is scanned. This tool is perfect for small beams that don t need the full sensor area. PIXEL ADDRESSING Increase the data transfer rate by using larger pixels or by reducing the number of pixels. This is great for large beams that don t need the full resolution. Full Resolution Average 2 x 2 Decimate 2 x 2