Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

Similar documents
Capacitive level meters DLM 35 INSTRUCTION MANUAL. průmyslová elektronika

Ultrasonic level meters ULM 53. instruction manual. průmyslová elektronika

Ult r a s o n i c le v e l me t e r s ULM 55

Ultrasonic level meters ULM 53

ULTRASONIC LEVEL METERS ULM 53

Ultrasonic level meters ULM 70

ULTRASONIC LEVEL METERS ULM 70

Capacitive level meters DLM 35

ULTRASONIC LEVEL METERS LU 55 INSTRUCTION MANUAL

Ult r a s o n i c le v e l me t e r s ULM 70

MSLU Ultrasonic Level Meters

Capacitive level meters CLM 36 INSTRUCTIONS MANUAL. průmyslová elektronika

MULTIFUNCTION GRAPHICAL UNIT MGU 800

Capacitive level meters CLM 36

USER S MANUAL. Rail-mounted temperature transmitter ATL

INSTRUCTION MANUAL Capacitive level sensors DLS 35

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OPTIFLUX 5000 Technical Datasheet

High-quality pressure transmitter For general industrial applications Model S-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Pressure transmitter For general industrial applications Model A-10

OPTIFLUX 5000 Technical Datasheet

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

WATERFLUX 3000 Quick Start

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

BROADBAND LINEAR AMPLIFIER Model P150

FMG90 Series Electromagnetic Flow Meter

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

WATERFLUX 3000 Quick Start

2-wire level transmitter

Magnetic Inductive Flow Sensor induq

Flow Measurement SITRANS F US Inline

INSTALLATION MANUAL GIOTTO SCREEN

LF Conductivity Measuring Probe

FMG70B Series Magnetic Inductive Flow Sensor

Wind Transmitter - compact

Wind Transmitter compact xx

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Pressure transmitter for general industrial applications Model A-10

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

OPTIFLUX 1000 Technical Datasheet

Ultrasonic Level Meter SLU

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Thermocouple - Transducer

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

PPS MFS series - Installation Guide. Power Protector Stabilizer V 3.8 1

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

Submersible pressure sensor For oils and fuels Model LF-1

Pressure transmitter for general industrial applications Model A-10

KRF EMC Filters Installation, Operation and Maintenance Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

CONTENTS MS2033A. 1.Introduction Safety Information...01

Technical Manual TRANSDUCER AMPLIFIER TYPE S7TW. Doc. Ref CD1210W

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Resistance thermometer Model TR30, compact design

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

BROADBAND LINEAR AMPLIFIER Model F1020 (models F10A and F20A combined)

Pressure transmitter For general industrial applications Model A-10

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Dialog with the medium.» BEDIA Capacitive Level Sensors for industrial applications

BML-S1F_-A/Q _-M _-_0-KA Magnetic Linear Encoder System. User's Guide. Magnetic Linear Encoder System BML-S1F_-A/Q _-M _-_0-KA

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Liquid level monitors and controls

Model: &

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

SEPARATOR P20G TYPE USER S MANUAL

U5300 Industrial Pressure Transducer

Operating instructions Electronic level sensor LK / / 2008

M5800 Pressure Transducer with Rotatable Display

QL55 Series Luminescence Sensor

OMNI-DIRECTIONAL WIDEBAND ANTENNA MODEL EM GHz - 18 GHz

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

ED701 General Industry Pressure Transmitter

30XR-A Professional Digital Multimeter Users Manual

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Submersible pressure sensor For water and wastewater Model LW-1

Industrial Pressure Transducers

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

AT Current Instrument Transformer Instructions for installation, use and maintenance

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

Nano SPY Ref : 11816C

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

U5700 Submersible Liquid Level Pressure Transducer

MS2030 CAT III 600 V A V AUTO RS232

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Manual. MOVITRAC LTE-B/LTP-B Accessories Braking Resistors, Filters, Chokes, Shielding * _0515*

External brake resistor AX2090-BW5x

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Transcription:

průmyslová elektronika INSTRUCTIONS MANUAL Capacitive level meters CLM 40 Before level meters usage please read instructions in this service manual and keep it for further use. Service manual is for all types of level meters series CLM-40. Producer reserves the right to make changes without any previous announcement.

Table of contents 1. Measuring principle...3 2. Areas of application...3 3. Variants of sensors...4 4. Dimensional drawings...4 5. Installation and putting into operation...4 6. Installation...5 7. Electrical connection...5 8. Setting...6 9. Use, manipulation and maintenance...7 10. Order code...7 11. Correct specification examples...7 12. Accessories...8 13. Safety, protections and compatibility...8 14. Marking of labels...8 15. Specification...9

Used symbols To ensure maximum safety of control processes, we have defined the following safety instructions and information. Each instruction is labeled with the appropriate pictogram. Alert, warning, danger This symbol informs you about particularly important instructions for installation and operation of equipment or dangerous situations that may occur during the installation and operation. Not observing these instructions may cause disturbance, damage or destruction of equipment or may cause injury Information This symbol indicates particularly important characteristics of the device. Note This symbol indicates helpful additional information. all types Valid for: In the border are the types CLM, for which is intended the chapter. Safety All operations described in this instruction manual have to be carried out only by trained personnel or an accredited person. Warranty and post warranty service must be exclusively carried out by the manufacturer. Improper use, installation or set-up of the level meter can result in crashes in the application (overfilling of the tank or damage of system components). The manufacturer is not responsible for improper use, losses of work caused by either direct or indirect damage, and for expenses incurred during installation or use of the level meter. 1. Measuring principle Capacitive level meter CLM is intended for continuous measurement of the level of fuel (diesel). It consists of a measuring electrode and the electronics housing to which is firmly attached the cable. The electronic part converts the capacity to the current or voltage signal. For accurate measurements independent on the tank shape is the rod electrode placed inside the reference tube. Setting is done by touching the magnetic pen.the level meter has no neither mechanical moving parts and so its installation is very simple. The production of its electrodes is possible in any length in the range from 100 to 1000 mm, so that the level meter can go through entire height of the tank. Mounting of the tank level meter is done by using 5-hole flange (SAE). 2. Areas of application Accurate level measurement in diesel tanks of trucks, construction and agricultural machinery, locomotives etc. After consultation with the manufacturer can be used for measuring and other non-conductive liquids (eg.: biodiesel, oil, etc.). CLMs are resistant to any changes in the atmosphere above the surface (vacuum, pressure, vapours, dust). 3 CLM 40 Dinel, s.r.o.

3. Variants of sensors CLM 40N 40 Uncoated rod electrode and reference tube, setting is done by touching the magnetic pen for the measured medium, possibility of shortening electrodes to the desired length. Electrode length from 0.1 m to 1 m. 4. Dimensional drawings CLM 40N 40 40 55 9 4 28 EMPTY M 36 68 5x 6 53,5 5 E 22 5. Installation and putting into operation Please follow next 3 steps: Installation Electrical connection Setting Dinel, s.r.o. CLM 40 4

6. Installation Mounting of the tank level meter is done by using 5-hole flange (SAE). Distance from the wall may be arbitrary and distance from the bottom is recommended min. 10 mm. Under the flange of the level, it is necessary to put in the rubber gasket resistant to petroleum products (see. Accessories). The level meter can be also used for similar applications in stationary tanks, containers, etc. 7. Electrical connection The level meter is designed to be connected to supply unit or to controller through two or threewire cable with. Connection diagram and inner view of the connector as shown in picture. Always disconnect the power supply before connecting the level meter! You can use car battery (24 V) or power supply (9... 30 V DC). Fig.1: Scheme of electrical connection Electrical connection can only be made when de-energized! The voltage source should be preferably realized as a stabilized power supply unit with safe voltage from 18 to 36 V DC, which can be a part of the evaluation or display device. In case of strong ambient electromagnetic interference, paralleling of conductors with power distribution, or for the distribution to distance over 30 m, we recommend using shielded cable. 5 CLM 40 Dinel, s.r.o.

8. Setting The device shall be set up by applying the magnetic pen onto sensitive spots. Basic mode Setting of lower limit 4 ma 1. Drain the tank to the lower measured level. 2. Set the level meter output to the value of 4 ma by applying the magnetic pen to the sensitive spot " EMPTY" for at least 2 s. Hold the magnetic pen on the sensitive spot for at least additional 3 s to confirm the set value and store it in the internal memory of the level meter. 3. Any other setting is possible 2 s after the magnetic pen is removed from the sensitive spot. Setting of upper limit 20 ma 1. Fill the tank up to the upper measured level. 2. Set the level meter output to the value of 20 ma by applying the magnetic pen to the sensitive spot "FULL" for at least 2 s. Hold the magnetic pen on the sensitive spot for at least additional 3 s to confirm the set value and store it in the internal memory of the level meter. 3. Any other setting is possible 2 s after the magnetic pen is removed from the sensitive spot. Inverse mode In the inverse mode, set the lower limit of 4 ma when the tank is filled up to the upper measured surface level and the upper limit of 20 ma when the tank is drained to the lower measured surface level. Dinel, s.r.o. CLM 40 6

9. Use, manipulation and maintenance The level meter does not require any personnel for its operation. Follow-up displaying device is used to inform the technological entity operating personnel on the measured substance level height during the operation. MAINTAINCE OF LEVEL METER Maintenance of this equipment consists in verification of integrity of the level meter and of the supply cable. Depending on the character of the substance measured, we recommend to verify at least once per year the clarity of the ultrasound transducer emitting field and to clean it, respectively. In case any visible defects are discovered, the manufacturer or reseller of this equipment must be contacted immediately. It is forbidden to perform any modifications or interventions into the CLM 40 level meter without manufacturer's approval. Potential repairs must be carried out by the manufacturer or by a manufacturer authorized service organization only. Installation, commissioning, operation and maintenance of the CLM 40 level meter has to be carried out in accordance with this instruction manual; the provisions of regulations in force regarding the installation of electrical equipment have to be adhered to. 10. Order code CLM 40N 40 E cable cable length in m electrode length in m Connection method: V plastic cable gland with spiral (+ cable length) H plastic cable gland for protective hose (+ cable length) Type of output: I current (4... 20 ma) Process connection: F5 flange with 5 holes G thread G1" 11. Correct specification examples CLM 40N 40 F5 I V E1000 (N) performance to normal area; (40) rod electrode with reference tube; (F) flange with 5 holes; (I) current output (4... 20 ma); (V) cable gland; (E1000) length of electrode 1000 mm CLM 40N 40 G I H E800 (N) performance to normal area; (40) rod electrode with reference tube; (G) thread G1"; (I) current output (4... 20 ma); (H) cable gland for protective hose; (E800) length of electrode 800 mm 7 CLM 40 Dinel, s.r.o.

12. Accessories Optional for extra charge Extra cable (over the standard length 2 m) Rubber seal CLM-40 5 otv NBR ( for flange with 5 holes) 13. Safety, protections and compatibility Level meter CLM 40 is equipped with protection against electric shock on electrode, reverse polarity, output current overload, short circuit and short time over voltages. Electromagnetic compatibility is provided by conformity with standards: EN 55022/B, EN 61326-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6. 14. Marking of labels Level meters label data CLM 40N 40 I-_: www.dinel.cz Made in Czech Republic CLM-40N-40-F5-I-V E 300 Cable: 1 m Ser. No.: 150001 U=9... 30 V I = 4... 20 ma t a = -40... +85 C ATEST 8 SD 3482 IP68 Symbol of producer: logo Dinel web address: www.dinel.cz Country of origin: Made in Czech Republic Type of level meter: CLM-40N-40-_-I-_, include length of electrode: E v mm Length of cable: Cable 1 m Serial number: Ser. No.: - (from the left: production year, serial production number) Supply voltage: U = 9 30 V DC Output current range: I = 4 20 ma Ambient temperature range: t a = -40... +85 C Protection class: IP 68 Compliance mark: Electro-waste take-back system mark: Dinel, s.r.o. CLM 40 8

15. Specification Technical specification Supply voltage Current output 9... 30 V DC 4... 20 ma Load resistance R (U - 9) / 0,02 [Ω; V] Nonlinearity max. 1 % Temperature error Voltage error for current and voltage output Internal resistance / Electric strength (Electrode Housing) Coupling capacity / Electric strength (Housing Supply leads) Coupling capacity / Electric strength (Electrode Supply leads) Protection class max. 0,05% / K max. 0,3 μa/v 1 MΩ / 200 V AC 91 nf / 500 V AC 47 nf / 500 V AC IP68 Ambient temperature range - 40... +85 C Cable PU 2x1 mm 2 Process connection Cable gland Weight (exclude electrode) CLM 40N 40 F5 I _ CLM 40N 40 G I _ CLM 40N 40 _ I V CLM 40N 40 _ I H Flange with 5 holes Thread G1" cable gland with spiral relief cable gland for protective hose Approx. 0,3 kg Material performance Sensor part Standard material Housing stainless st. W. Nr. 1.4301 (AISI 304) Cable gland PA Cable insulation PUR Electrode stainless st. W. Nr. 1.4301 (AISI 304) Reference tube stainless st. W. Nr. 1.4301 (AISI 304) Process flange stainless st. W. Nr. 1.4301 (AISI 304) Insulating bushing PA + GF30 9 CLM 40 Dinel, s.r.o.

Dinel, s.r.o. CLM 40 10

industrial electronics Dinel, s.r.o. U Tescomy 249 760 01 Zlín Czech Republic Tel.: +420 577 002 003 Fax: +420 577 002 007 E-mail: sale@dinel.cz www.dinel.cz The lastest version of this instruction manual can be found at www.dinel.cz Version: 10/2015