This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

Similar documents
Motor 1- GENERAL DESCRIPTION

WIRELESS DIMMER FOR HEATING

COD GB / 1.0 RBAND/UMS - RBAND/CSM

PILOT Instructions 1. APPLICATIONS 2. OPERATING INDICATIONS 3. TERMINAL CONNECTIONS + - ON 3 OFF 10 OFF OFF 18/07/18

TCO6RX / TCO6TX. Transceiver system for mechanical safety and 8,2K resistive edges. Bidirectional communication

Istructions. Central control board for electromechanical gearmotors HERCULES 24V

T.CO.O - R.CO.O Double

ELECTRONIC PANEL MC15

RADIOBAND V3 Programming & Installation Manual

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.

ERONE CH RECEIVER

TO.GO 2VA TO.GO 4VA TO.GO 2AS TO.GO 2A TO.GO 2AK TO.GO 4AK TO.GO 2QV TO.GO 4QV TO.GO 4ASE PROGRAMMING GUIDE

VELA-RX MOTORE 220V 500W

R PROFLAME Instruction Book Collection

Operating Instructions

RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL

Supply 12Vdc nominal (9 Vdc minimum, 14,5Vdc maximum ) Max Current Drain. from a , V Carrier Frequency

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

AKR-1. Digital Keyless Entry System With Built-in Wireless Receiver. Installation and Programming Instructions

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

K580M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN

INDEX 1 - PRODUCT FEATURES

Digital Electronic Thermostat With RF

ENCODING PHOTOCELLS MF6

Wireless multizone receiver RDE-MZ6

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

IRRIGATION 810-3R RECEIVER GUIDE

MRW 50, MRW 100, MRW 200. External Protection Barrier. Quick Installation Guide

Instructions for programming and use Starline Roldeck - floorpanel control RD-2001

CROSS Chassis from 160 A to 450 A

K125M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN

D705M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

DECORATOR COMFORT CONTROL (DCC)

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

Robus 600/1000. Programmable functions using the Oview programmer. STF ROBUS Rev00 Firmware: RF02

CAME QP- V4.4 SPECIFICATION STANDARDS CABLE PLAN CABLE TYPES Z SERIES AUDIOCODE CONTROL SET FOR DOUBLE LEAF GATES

HL 675 Data / Impulse Transmitter set User Manual

OVEN INDUSTRIES, INC. Model 5C7-362

B-Tronic EasyControl EC5401B

90 ReStart AUTOMATIC RECLOSING DEVICES

Built-in receiver module

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

HORNET Remote Control Systems

Radio Control Installation and Operating Instructions System 4

U S E R S M A N U A L

Universal radio receiver

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

PRO Professional Radio Control Series Applications

ELSEMA. GLR2701 Single Channel 27MHz Gigalink Receiver with Timer Controlled Relay Output

CONTENTS XV300K GB r doc XV300K 2/13

True RMS Digital Multimeter Model:

Modular Radio Telemetry System

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

SABRETrap Control. Description

Technical description of the fuel tank sensor "Escort TD-500"

Wireless Control Systems

USER S MANUAL. This manual must be considered an integral part of the projector. The user must read this manual before using the projector

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

200 RTH OFF ON IN OUT ALARM RESET

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

With Audible Detect Signal

LIGHT- INDUSTRIAL SLIDING GATE OPERATORS

ALPHA - ALPHA BOM INSTALLATION AND USER'S MANUAL GB CONTROL PANEL

Block Programmable Receiver 800/1600 Users SEL2641R433-K8/K8P/K16P

DUCATI Control box. DUCATI Kontrol large DUCATI Kontrol small 10. PREDISPOSITIONS

S449 DIGITAL QUARTZ SUPERHETERODYNE RADIO CONTROLS WITH ROLLING CODES TXQ449400

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

Modular Radio Telemetry System

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

LT3000 ULTRASONIC LEVEL TRANSMITTER

INSTALLATION & OPERATION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

User Manual of MOBILUS C-SWP external module.

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

User Guide for Pager RX900-LED

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

VIPER Remote Control Systems

Digital Clamp Meter Model: &

DS1 Radio command digital selector

FMR ELSEMA 2-Channel 151MHz Receiver - FMR15102

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

P700-WLS ioprox Receiver

58Khz ACOUSTO MAGNETIC SYSTEMS WIRING HANDBOOK

Wireless Programmer for Wireless Sensor System

Quik Bridge Loop Receiver Installation Instructions

FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

CX-A6 Amplifier Installation & User Guide V8.0

MINI-SA2. User Manual. Technical Characteristics. Mounting. Version 1.1 MINI-SA2

Transcription:

1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter channel memorization by means of internal push button or via radio. Possibility to connect wired with auto-test control before every closing movement. Possibility to connect a 240 V courtesy lamp with variable time from 1 min. to 12 hours (default 1min.) Plastic housing for external use equipped with clamps. Possibility of centralized controls for simultaneous control of several appliances. Possibility to connect external mechanical controls with dynamic push button function and blockage push button. 2- CONNECTIONS TELECO AUTOMATION SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 www.telecoautomation.com This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights Zone 240V Safety zone, isolated low voltage Ground Power supply 240V Motor Courtesy lamp Réflex photocell TD TB Mains Earth Motor Earth L N Mains Neutral Mains Live Open Com Motor Close Description of the connections: 1 Input ground general power supply 2 Input ground motor 3 Input general power supply 240 V phase 4 Input general power supply 240 V neutral 5 Opening output relay motor contact 6 Output 240 V neutral by means of fuse (common motor) 7 Closing output relay motor contact 10-11 Output LC 240 V 300 W max. for courtesy lamp (only for the version with courtesy light) 12 Positive output 12/15Vdc 80mA for photocells 13 Safety common contact 14 Negative output for photocells (autotest) + 12V Com neg tx FTC FTC Com TD 15 FTC input (NC normally closed) TB Com 19 Push buttons common for TD 20 Dynamic push-button input (NO normally open) 21 Stop push-button TB (NC normally closed) 22 Push buttons common for TB 24 Antenna ground 25 Antenna pole (wire 8.5cm) Code Number: Series Model number Draft Date TVLink RS868 TVPRP868F08E T574.01 25/11/13 1

Warning: The installed safety device must ensure the safety of the door according to EN13241-1 (EN12453, EN12445) If TB stop NC contact is not used it must be jumpered. If the FTC input NC is not used it must be jumpered to 14 terminal Connections with reflex Connections with photocells TB com nc - + 12/15 Vdc REFLEX 8,2Kohm resistance 14 15 if the FTC input are not used put a bridge between 14 and 15 terminals 14 15 if the FTC input are not used put a bridge between 14 and 15 terminals 3- Technical specifications Reception frequency 868.3 MHz Sensibility (finely tuned signal) 1 uv Power supply 240 V Operating temperature range -20 +50 C Maximum power at the motor: Voltage 250 V Maximum power 400 W Maximum commutable power at output courtesy lamp 240 V 300 W Antenna The correct installation and connection of the antenna is fundamental in order to obtain a good action ray for the installation. Connect the provided 8.5 cm piece of wire to the antenna pole connection on the device. As an alternative (and for better results) use a tuned antenna connected to the receiver via coaxial cable RG58 (impedance 50ohm) with a maximum length of 15 metres (mod. ANT868) 2

After the reset, the control unit carries out only opening commands until the door is fully opened. After the complete opening, the functioning of the commands is standard. 4- Dip-switch function ON 1 2 ON 1 2 Dip1: OFF The closing movement is in dead man mode, during the opening it is automatic (even if the automatic reclosing is excluded) ON The opening and closing movement is automatic. Dip2: ON 1 2 ON 1 2 ON Activation of automatic reclosing ** OFF Deactivation of automatic reclosing **The automatic reclosing is activated only if the door is fully open to the limit switch. After passing the photocell the door closes (after 3 sec.). 3

5.0- To memorize the transmitters from the receiver Transmitters The transmitters are encoded in the factory and each transmitter has its own unique code. Caution! If you keep a channel button pressed down for more than 30 seconds the transmitter will automatically turn off. The receiver is compatible with all transmitters of the TVLink range: TVTXV, TVTXP, TVTXE, TVTXC, TVTXI, TVTXK, TVTXQ, TVTXL, TVTXS. The transmitter code can be inserted (memorized) or deleted directly in the receiver or via radio from the transmitter. This last possibility allows to insert new transmitters into an existing installation, without acting directly on the receiver. This may be carried out easily by the end user without the help of the installer, and guaranteeing the total secrecy of the code. - The codes transmission type is Rolling- code. The code is changed for every transmission through the use of an algorithm that only the receiver is able to recognize and therefore to decide if the transmitted code corresponds to the original code. - In the receiver the user code is memorized under Eeprom, which maintains the code information even when faced with blackouts (max. 42 code-memorizations). It is adjustable to delete the whole memory before each installation. Errors during the memorizing If the code is not memorized it could be due to the following conditions: -The code already exists in memory -The memory is full (max. 42 codes). In this case the Buzzer will make 3 beeps both during the memorization phase both after the reset of the receiver. Transmitter le behaviour according to battery status: Battery OK LOW Battery CHANGE the Battery 5.1- Possibility to memorize the transmitter in three ways: 1 - Mode 1: Single channels with dynamic function, open, stop, close 2 - Mode 2: Control from two channels ch1 with ch2, ch3 with ch4 and ch5 with ch6 and ch7. Ch1, ch3, ch5 for opening controls, ch2, ch4 and ch7 for closing controls, ch6 stop. 3- Mode 3: the memorised channel operates on the courtesy light in on/off mode. 5.1.1- Mode 1: single push-button The memorization of the channels is carried out in single mode for each channel; the memorised channel will activate the controls in dynamic mode open, stop, close. open, stop, close Press and hold the push button P1, the buzzer B1 will make 1 beep and sound continuously. Transmit the channel which is to be memorized, the buzzer B1 will sound intermittently.... Beeeeeep 4

5.1.2- Mode 2: The memorization of the channels is done in pairs: channel 1 with channel 2 (or vice versa) and channel 3 with channel 4 (and vice versa) and channels 5-6-7. open close Press twice and hold the push button P1 down, the buzzer B1 will make two beeps and sound continuously. press 2 times and hold Transmit one of the channel which is to be memorized, the buzzer B1 will sound intermittently.... Beeeeeep 5.1.3- Mode 3 The memorization of the channels is carried out in single mode for each channel; the memorised channel will turn on and turn off the courtesy light in dynamic mode. On/Off light Press three times and hold the push button P1 down, the buzzer B1 will make three beeps and sound continuously. Transmit the channel which is to be memorized, the buzzer B1 will sound intermittently. press 3 times and hold... Beeeeeep 5

5.2.1- To cancel a code from the receiver: the deletion in single mode or in pairs is done as in the memorization mode 1, 2 and 3: Press 4 times and hold the pushbutton P1 down, the buzzer B1 will emit an intermittent slowly sound. Transmit the code which is to be cancelled, once the channel is cancelled the buzzer B1 will sound continuously. press 4 times and hold............... Beeeeeep 5.2.2- To cancel all memorized codes: Press 5 times and hold the push-button P1 down for at least 10 s (during this period the buzzer B1 will sound intermittently and quickly) until the buzzer B1 will sound continuously. At the end release the push-button. press 5 times and hold 10 sec............. Beeeeeep 5.2.3- To cancel via radio a code by means of a transmitter already set in the memory: Press the internal push button at regular intervals for three times within 5 s, the buzzer B1 will emit an intermittent slowly sound. Transmit the code which is to be cancelled within 5 s. Once the channel has been cancelled the buzzer will stop sounding. press for three times Beeeeep.............. Beeeeeep 6

5.3- How to insert a transmitter via radio without accessing the receiver when the memory is empty (first installation), in this mode the channels function of the transmitter will be in mode 2. The transmitter to be inserted will become the master transmitter for inserting other transmitters. Press the internal push-button of the transmitter, the receiver will be activated for the memorization and the buzzer will sound continuously for 5 s. Transmit the channel which is to be memorized within 5 s. Once the channel is memorized the buzzer will sound intermittently. press once Beeeeeep... Warning: when the memory is empty do not give power to more than one receiver at the same time, because the above mentioned procedure activates all receivers. 5.4- Memorization of channels from the transmitter (additional transmitters) The type of memorization of the channels (single or in pairs) depends on how the channel, which is used in point 2, has been memorized. 1- Press the button of the transmitter, the buzzer will sound continuously. 2- Press within 5 seconds a channel which is already present in the memory of the receiver, the buzzer will interrupt the sound for 1 sec, and then carry on for 5 seconds. 3- Transmit the channel to be memorized. Once memorized the buzzer will sound intermittently, release the push button. press once memorized transmitter memorized transmitter new transmitter Beeeeeep 1 sec. Beeeeeep... 7

6.0- Time settings 6.1- Procedure for the courtesy light time setting (from 1min max 12h) This procedure can be done within 30 seconds after the reset. Sum 1min to the set time. 1- Press for 5 sec. the release and re-press within 5 sec. the push button of the push button of the transmitter 5 transmitter; the buzzer will times, the buzzer will sound 1 beep sound 1 beep, at each pressure and at the end it will sound 3 beeps (if after 5 sec. the push button will not be pressed the buzzer will sound 4 beeps and exit from the procedure). On press and hold for 5 sec. press 5 times 5 sec. wait 5 sec. 240V Beeep 1 2 3 4 5 1 2 3 2- Press the push button of the transmitter, the buzzer will sound one beep and the courtesy light turns on, the time to be memorised starts. 3- After the desired time press again the push button of the transmitter in order to exit and memorise the courtesy light time, the light turns off. press once start time count press once Stop and memorize the time 8

6.2- Procedure for the automatic re-closing time setting (from 5s max 90s) (default 5sec.) This procedure can be done within 30 seconds after the reset. Sum 5s to the set time. 1- Press for 5 sec. the push release and re-press within 5 sec. the button of the transmitter; push button of the transmitter 8 times, the buzzer will sound 1 beep, the buzzer will sound 1 beep at each pressure and at the end it will sound 2 beeps (if after 5 sec. the push button will not be pressed the buzzer will sound 4 beeps and exit from the procedure). On press and hold for 5 sec. press 8 times 240V Beeep 5 sec. wait 5 sec. 1 2 3 4 5 6 7 8 1 2 2- Press the push button of the transmitter, the buzzer will sound one beep, the time to be memorised starts. 3- After the desired time press again the push button of the transmitter in order to exit and memorise the re-closing time. The buzzer will sound one beep. press once start time count press once Stop and memorize the time 9

7.0- Courtesy light operation mode as the ambient light or alarm This procedure can be done within 30 seconds after the reset. 1- Press for 5 sec. the push release and re-press within 5 sec. the button of the transmitter; push button of the transmitter 3 the buzzer will sound 1 beep, times, the buzzer will sound 1 beep at each pressure and at the end it will On press and hold for 5 sec. press 3 times sound: 3 beeps to indicate ambient light mode and 5 beeps to indicate alarm function. 240V Beeep 5 sec. wait 5 sec. 1 2 3 3 s: ambient light 5 s: alarm function 7.1- Courtesy light function as alarm It is possible to use the output of the courtesy light, to interface the control unit to an alarm system, memorizing a radio alarm transmitter (code: TVSSH or TVTCTM) with mode 3 memorization and activating the courtesy light as alarm function (see 7.1 ). If the control unit receives an alarm signal from the radio alarm transmitter, the courtesy light output is activated for 1 minute. Warning: the courtesy light output provides 240Vac. The interface of the alarm system must be arranged according to the specifications of the installed alarm system. Alarm interface Alarm system 10

8.0- Acoustic signals emitted by the control unit... 1 beep: reset 2 beeps: motor is not connected 3 beeps: error on FTC input (FTC is activated) 5 beeps: error on safeties test (safeties test failed) 8 beeps: Limit switch error It is possible to close the door also with a not working CSP or with a negative safety test (forced closing), by pressing and holding down the closing push button; after 5 s the control unit closes in dead man mode. TB Led and FTC Led: ON: TB and FTC input alarm not activated, the inputs work normally. OFF: input alarm activated, security alarmed OK The LED switches off every time that the autotest is done. 9.0- Safety inputs function -TB: Normally closed input, stop-push-button stops the movement in each condition. (It is not possible the forced closing) - Traditional photocell input (inputs 12-13-14-15); if not used jumper the inputs 14-15 (it only works in closure). WARNING: all the devices invert the movement for 2 sec. If the safety is broken it is possible to close the door with a maintained closing command; press the command for >5sec.; after this time the movement is in dead man mode. WARNING The above mentioned product must be installed only by qualified technical personnel in compliance with the standards of automatic openings. All connections must be rated for a single-phase power supply of 240V. For the disconnection from the power line, use an allpole switch with contact with an opening of at least 3,5mm. Only suitable materials for the connections must be used to guarantee insulation that complies with current standards on the subject of electrical safety. The programmer carries out movement controls; all the necessary safety devices are to be seen separately. Incorrect wiring will cause incorrect functioning impairing the safety purpose for which the product has been designed so that people injuries could occur; failure to follow instructions can cause personal injury and/or property damage. The correct working of the product must be checked once a year. Keep the 240V wires from the low voltage safety wires separately. The earth-wires must be fixed by means of an additional fastening nearby the terminals; this fastening has to be done by qualified technical personnel during the installation phase. The appliance has been tested with a power supply wire type H05VV-F; the power supply wires for outdoor use have not to be lighter than the ordinary wires type H05RN-F. The safety devices have to be in conformity with EN12978. The installation of the control unit has to be done by fixing the box vertically with the clamps downwards. The programmer is in conformity with the RAEE and RoHS directive. The earth wire must be longer than the other wires because it must be the last to break off if the cable clamps are slack. Remember that there are specific standards that must be complied with both as regarding the safety of the electrical systems and as regarding the remote control of tubular motors for roller blind. In the view of a constant development of their products, the manufacturer reserves the right for changing technical data and features without prior notice. 11

EXPLOSION VIEW DISASSEMBLY BOX DIMENSIONS ASSEMBLY 205 mm 85 mm 145 mm 290 mm 85 mm 145 mm www.telecoautomation.com 12