Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Similar documents
Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Safety Monitoring Relays

SPST-NO SPDT DPST-NO DPDT

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

CSM_G7S-_-E_DS_E_7_1

SPST-NO SPDT DPST-NO DPDT

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Safety Relay Unit. OFF-delay time

Model Number Structure

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

OMRON MK-I / -S RELAY

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Classification Enclosure rating Contact form Contact material

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

Relays with Forcibly Guided Contacts G7SA

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

General-purpose Relay

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

General-purpose Relay

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Surface-mounting Relay

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

3. Contact Form A: SPST-NO

Details on the New G2RS

Model Number Structure

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Ratings Ratings SPST-NO SPDT DPST-NO DPDT

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

PCB Footprint Max.Load Coil Voltage Non-Latching part number Single-coil latching part number Standard ground terminal (1GHz)

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

General-purpose Relay

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

MY-GS CSM_MY-GS_DS_E_2_1

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

A W - A 2A R - 24D - 1

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

Technical Information General Purpose Relays. Glossary. Maximum switching power [W(VA)] Switching current (A) Switching voltage (V) Contact Symbols

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Class Sealing Fully sealed Contact configuration Rated coil voltage Model Basic Type SPDT 4.5 VDC G6Y-1 5 VDC 9 VDC 12 VDC 24 VDC

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Slim compact safety relay

Features. Insulation system F 835-1A-F-C 835-1A-F-S L-1A-C 835L-1A-S F 835L-1A-F-C 835L-1A-F-S NL-1A-C 835NL-1A-S

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Solid-state Twin Timer

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

High-precision Optical Switch

G2RV-SL Slim I/O Relay will be discontinued February 2019

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

PCB relay for DC voltage, polarized, monostable or bistable

Compliant with European standards 1a/1c 6A Slim power relays

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

G8HN-J. Specifications. Contact Data. Automotive PCB Relay based on Micro ISO. Features

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

SLIM COMPACT SAFETY RELAY

onlinecomponents.com

Features. UL Insulation. Sealed type washable 1A (SPNO) H H-1A-C 845H-1A-V 845H-1A-S. system approval Flux tight Sealed type

Compact Relay Family with Forcibly Guided Contacts

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

NPN PNP NPN PNP NPN PNP

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

Solid-state Timer H3DS

Transcription:

Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery, machine tools, and other production machinery. Four-pole and six-pole Relays are available. The Relay s terminal arrangement simplifies PWB pattern design. Reinforced insulation between inputs and outputs. Reinforced insulation between some poles. RCX VDE UL, CSA approval. CE marking. Note: Be sure to refer to the Precautions on page 223. Ordering Information Safety Relays Type Sealing Poles Contacts Rated Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC -3A1B DPST-NO, DPST-NC -2A2B 6 poles 5PST-NO, SPST-NC -5A1B 4PST-NO, DPST-NC -4A2B 3PST-NO, 3PST-NC -3A3B Safety Relay Sockets Type LED indicator Poles Rated Model Track-mounting Track mounting and screw mounting possible No 4 poles --- P7SA-10F 6 poles P7SA-14F Yes 4 poles 24 VDC P7SA-10F-ND 6 poles P7SA-14F-ND Back-mounting PCB terminals No 4 poles --- P7SA-10P 6 poles P7SA-14P Model Number Legend -@A@B 1 2 1. NO Contact Poles 2: DPST-NO 3: 3PST-NO 4: 4PST-NO 5: 5PST-NO 2. NC Contact Poles 1: SPST-NC 2: DPST-NC 3: 3PST-NC 218

Specifications Ratings Coil Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of 15%. 2. Performance characteristics are based on a coil temperature of 23 C. 3. The value given for the maximum is for s applied instantaneously to the Relay coil (at an ambient temperature of 23 C) and not continuously. Contacts Characteristics Safety Relay Sockets Note: Rated 24 VDC 4 poles: 15 ma 6 poles: 20.8 ma 1. If the P7SA-1@F is used between 55 and 85 C, reduce the continuous current (from 6A) by 0.1 A for every degree. 2. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. 3. When using the P7SA-1@F-ND at 24 VDC, use at an ambient operating temperature from 25 to 55 C. Safety Relays Rated current Coil resistance Must-operate 4 poles: 1,600 W 6 poles: 1,152 W Load Resistive load (cos f =1) Rated load 6 A at 250 VAC, 6 A at 30 VDC Rated carry current 6 A Max. switching 250 VAC, 125 VDC Max. switching current 6 A Max. switching capacity (reference value) 1,500 VA, 180 W Must-release Max. Power consumption 75% max. (V) 10% min. (V) 110% (V) 4 poles: Approx. 360 mw 6 poles: Approx. 500 mw Model Continuous current Dielectric strength Insulation resistance P7SA-14@ 6 A (see note 1) 2,500 VAC for 1 min. between poles 100 MW min. (see note 2) Contact resistance Operating time (see note 2) Response time (see note 2) Release time (see note 2) Maximum operating Mechanical frequency Rated load Insulation resistance 100 mw max. (The contact resistance was measured with 1 A at 5 VDC using the -drop method.) 20 ms max. 10 ms max. (The response time is the time it takes for the normally open contacts to open after the coil is turned OFF.) 20 ms max. 36,000 operations/hr 1,800 operations/hr 100 MW min. (at 500 VDC) (The insulation resistance was measured with a 500-VDC megger at the same places that the dielectric strength was measured.) Dielectric strength (see notes 3, 4) Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min (2,500 VAC between poles 3 4 in 4-pole Relays or poles 3 5, 4 6, and 5 6 in 6-pole Relays.) Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction: 1,000 m/s 2 Malfunction: 100 m/s 2 Endurance Mechanical: 10,000,000 operations min. (at approx. 36,000 operations/hr) Electrical: 100,000 operations min. (at the rated load and approx. 1,800 operations/hr) Failure rate (reference value) (see note 5) 5 VDC, 1 ma Ambient temperature (see note 6) Operating: 40 C to 85 C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight 4 poles: Approx. 22 g 6 poles: Approx. 25 g Approved standards EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14 Note: 1. The values listed above are initial values. 219

2. These times were measured at the rated and an ambient temperature of 23 C. Contact bounce time is not included. 3. Pole 3 refers to terminals 31 32 or 33 34, pole 4 refers to terminals 43 44, pole 5 refers to terminals 53 54, and pole 6 refers to terminals 63 64. 4. When using a P7SA Socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min. 5. Failure rate (reference value) is for a switching frequency of 300 operations/min. 6. When operating at a temperature between 70 C and 85 C, reduce the rated carry current (6 A at 70 C or less) by 0.1 A for each degree above 70 C. Dimensions Note: All units are in millimeters unless otherwise indicated. The diagrams are drawn in perspective. Safety Relays -3A1B -2A2B 40 max. 13 max. Terminal Arrangement/ Internal Connection Diagram -3A1B Printed Circuit Board Design Diagram Ten, 1.4 dia. 24 max. 1 3.5-2A2B Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals 11-12 and 21-22 are normally closed. -5A1B -4A2B -3A3B Terminal Arrangement/ Internal Connection Diagram -5A1B Printed Circuit Board Design Diagram 50 max. 13 max. Fourteen, 1.4 dia. 24 max. -4A2B 1 3.5-3A3B Note: Terminals 23-24, 33-34, 53-54, and 63-64 are normally open. Terminals 11-12, 21-22, and 31-32 are normally closed. 220

Safety Relay Sockets Track-mounting Socket P7SA-10F, P7SA-10F-ND Terminal Installation/Internal Connection Diagram -3A1B -2A2B 72 max. LED indicator 22.5 max. Ten, M3 6 max. Mounting Hole Placement Diagram Two, 4 dia. or M3.5 * This display circuit is available only for "-ND" models. Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals 11-12 and 21-22 are normally closed. 4 dia. Note: The socket is shown with the finger cover removed. 6 Note: Only the -ND Sockets have LED indicators. Track-mounting Socket P7SA-14F, P7SA-14F-ND Terminal Arrangement/Internal Connection Diagram -5A1B -4A2B -3A3B 30 max. Fourteen, M3 6 max. 72 max. LED indicator Mounting Hole Placement Diagram Two, 4 dia. or M3.5 * This display circuit is available only for "-ND" models. Note: Terminals 23-24, 33-34, 43-44, 53-54, and 63-64 are normally open. Terminals 11-12, 21-22, and 31-32 are normally closed. 4 dia. Note: The socket is shown with the finger cover removed. Note: Only the -ND Sockets have LED indicators. 6 221

P7SA-10P Back-mounting Socket (for PCB) 50 max. 15 max. Terminal Arrangement/Internal Connection Diagram Mounting Hole Placement -3A1B 41.5 max. Three, 3.2 dia. (for M3 tapping screws) -2A2B Ten, 1.1 dia. Three, 2.6 dia. (for M3 tapping screws) Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals 11-12 and 21-22 are normally closed. P7SA-14P Back-mounting Socket (for PCB) 60 max. Terminal Arrangement/Internal Connection Diagram Mounting Hole Placement 15 max. -5A1B 41.5 max. Fourteen, 1.1 dia. Three, 3.2 dia. (for M3 tapping screws) -4A2B Three, 2.6 dia. (for M3 tapping screws) -3A3B Note: Terminals 23-24, 33-34, 43-44, 53-54, and 63-64 are normally open. Terminals 11-12, 21-22, and 31-32 are normally closed. 222

Precautions Safety Relays A Safety Relay is a Relay with which a safety circuit can be configured. Wiring Use one of the following wires to connect to the P7SA-10F/10F- ND/14F/14F-ND. Stranded wire:0.75 to 1.5 mm 2 Solid wire:1.0 to 1.5 mm 2 Tighten each screw of the P7SA-10F/10F-ND/14F/14F-ND to a torque of 0.98 N m securely. Wire the terminals correctly with no mistakes in coil polarity, otherwise the will not operate. Cleaning The is not of enclosed construction. Therefore, do not wash the with water or detergent. Forcibly Guided Contacts (from EN50205) If an NO contact becomes welded, all NC contacts will maintain a minimum distance of mm when the coil is not energized. Likewise if an NC contact becomes welded, all NO contacts will maintain a minimum distance of mm when the coil is energized. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J120-E1-01B 223