LP PYRA 02. REV jan. 2007

Similar documents
LP PYRA 03. REV jan. 2007

LP UVA 02. REV jan. 2007

LP PYRA 06. REV Jan. 2007

LP UVA Introduction. 2 Working Principle. TEL r.a. FAX

LP PYRA 03. REV jan. 2007

LP PYRHE 16 AV. ACTIVE with 4..20mA CURRENT output ACTIVE with 0..1V or 0..5V o 0..10V VOLTAGE output to be defined at the time of placing the order

LP PYRA Introduction. 2 Working principle

USER S GUIDE. for MIDDLETON SOLAR SECONDARY STANDARD PYRANOMETER WITH INTEGRATING CAVITY DETECTOR

SOLAR MEASUREMENTS

LP SD18. [ GB ] Sunshine duration sensor

Hukseflux. Thermal Sensors USER MANUAL SR11. First class pyranometer. Copyright by Hukseflux manual v

English. Operating manual. Tipping bucket rain gauge HD Keep for future reference. Companies / Brands of GHM

Hukseflux. Thermal Sensors USER MANUAL SR20. Secondary standard pyranometer. Copyright by Hukseflux manual v

Hukseflux. Thermal Sensors USER MANUAL LP02. Second class pyranometer. Copyright by Hukseflux manual v1606

Hukseflux. Thermal Sensors USER MANUAL SRA20. Secondary standard albedometer. Copyright by Hukseflux manual v1705

USER MANUAL SR15-A1. Hukseflux. Thermal Sensors. Analogue first class pyranometer with millivolt output and heater

INSTRUCTION MANUAL UV RADIOMETERS

USER MANUAL SR25. Copyright by Hukseflux manual v

Hukseflux. Thermal Sensors USER MANUAL SR20. Secondary standard pyranometer. Copyright by Hukseflux manual v

USER MANUAL SR05 SERIES, DIGITAL VERSIONS. second class pyranometers with various outputs

Sensor PAR xxx

USER MANUAL SR30. Hukseflux. Thermal Sensors. Next level digital secondary standard pyranometer. compliant with IEC :2017 Class A

USER MANUAL SR20-D2. Digital secondary standard pyranometer with Modbus RTU and 4-20 ma output

SRS-200 Solar Radiation Sensor Installation and Setup Instructions. SRS-200 with optional Leveling Plate and Mounting Bracket. Revision 2.0.

Hukseflux. Thermal Sensors USER MANUAL IR20. Research grade pyrgeometer. Copyright by Hukseflux manual v

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

Hukseflux. Thermal Sensors USER MANUAL IR02. Pyrgeometer with heater. Copyright by Hukseflux manual v1604

ENGLISH Rev /07/2013. LP SD18 Sunshine Duration Sensor. 1 Introduction. 2 Operating Principle

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

SP02 and SP02-L USER S GUIDE

CNR 1. Net radiometer. Instruction Manual

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

USER MANUAL IR02. Pyrgeometer with heater

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

USER'S GUIDE. Vaisala HUMICAP Humidity and Temperature Transmitters HMD70U/Y U303EN11

The Rosemount 848T Wireless Temperature Transmitter

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

INSTRUCTION MANUAL PYRANOMETER

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Transmitter First Class

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by hand or by optional RCU (Remote Control Unit)

AC/DC Current Probes Model MR411 Model MR521

The Standard for over 40 Years

Brightness Transmitter

NR-LITE NET RADIOMETER INSTRUCTION MANUAL

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression

Wind Transmitter First Class Advanced Classified according to IEC ( )

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

SOLAR RADIATION & PHOTONIC SENSORS.

PYRANOMETER. Model SP-212 and SP-215

U S E R S M A N U A L

Wind Transmitter First Class / 141 / / 141 / 161

manual INSTRUCTION MANUAL

Global Water Instrumentation, Inc.

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

87.5 TO MHz BAND II 2 WAY 4.8dBi STACKED DIPOLE ANTENNA

FT01MHNG FT01MVNG. 530 nm DC-1 MBd RedLink Fiber Optic Transmitter Datasheet DESCRIPTION FEATURES APPLICATIONS AVAILABLE OPTIONS

USER MANUAL DR30-D1. Next level digital first class pyrheliometer, with heating and tilt sensor

TECHNICAL SHEET. Outdoor architectural projector RONDO-01 9LED. About the product. RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome

Global Water Instrumentation, Inc.

Red/Far-Red Sensor SKR 110. Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0)

Technical Specification Temperature-Humidity-Pressure Sensor

OWNER S MANUAL PYRANOMETER. Model SP-214

LI-1500 Light Sensor Logger

Room Sensors. for relative humidity and temperature

INSTRUCTION MANUAL (ATEX / IECEx)

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

OPTITEMP TT 20 Technical Datasheet

MANUAL. Electrostatic Field Meter EFM 235 / 255. System Prof. Dr.-Ing. Hans Kleinwächter

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Overview of types. Technical data

Wind Transmitter - with frequency output xx.xxx

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Current clamps for AC current

Wind Direction Transmitter - compact - GMR, analogue output xxx

/11 PV/

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression

OWNER S MANUAL PYRANOMETER. Model SP-214

Wind Transmitter - with analogue output xxx

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

High-precision process calibrator Model CED7000

670K9 SORtrax Level Transmitter

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

Type CP-S, CP-C & CP-A Switch mode

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

AMM-1022 Digital Multimeter USER`S MANUAL

clamps included Single Unit Double Unit

Photosynthetically Active Radiation (PAR) Smart Sensor (Part # S-LIA-M003)

Transcription:

REV. 1.0 10 jan. 2007 Our instruments' quality level is the results of the product continuous development. This can bring about differences between the information written in this manual and the instrument that you have purchased. We cannot entirely exclude errors in the manual, for which we apologize. The data, figures and descriptions contained in this manual cannot be legally asserted. We reserve the right to make changes and corrections without prior notice. - 1 -

1 Introduction The pyranometer measures the irradiance on a plane surface (Watt/ m 2 ). Measured irradiance is the result of the sum of direct solar irradiance and of diffuse irradiance. is a First Class pyranometer in accordance with ISO 9060 standard and with the criteria of the WMO Guide to Meteorological Instruments and Methods of Observation, fifth edition (1983). The pyranometer is produced in three versions: PASSIVE* AC AV ACTIVE, 4..20mA CURRENT output ACTIVE, 0..1** or 0..5 or 0..10 V VOLTAGE output, to be defined at the order. * Using SICRAM Module VP 472 it is possible to connect passive pyranometer to Indicator D09847. ** 0..1 output version can be connected to indicator HD2302.0 using SICRAM Module VP 474. The indicator reads directly in W/m 2. 2 Working Principle pyranometer is based on a thermopile sensor. The thermopile sensitive surface is coated with a black matt paint, which allows the pyranometer not to be selective at different wave lengths. The pyranometer spectral range is determined by the transmittance of the two glass domes type K5. Radiant energy is absorbed by the thermopile black surface, thus creating a difference of temperature between the center of the thermopile (hot junction) and the pyranometer body (cold junction). Thanks to the Seebeck effect, the difference of temperature between hot and cold junction is converted into a Difference of Potential. In order to grant the thermopile a proper thermal insulation from the wind and reduce the sensitivity to thermal irradiance, is equipped with two concentric domes having a diameter of 50mm and 30mm, respectively. The domes protect the thermopile from the dust, which, laying down on the black surface, might change spectral sensitivity. - 2 -

3 Installation and Mounting of the Pyranometer for the Measurement of Global Radiation: Before installing the pyranometer, refill the cartridge containing silica-gel crystals. Silica gel absorbs humidity in the dome chamber and prevents (in particular climatic conditions) internal condensation forming on the internal walls of the domes and measurement alteration. Do not touch the silica gel crystals with your hands while refilling the cartridge. Carry out the following instructions in an environment as drier as possible: 1- Loosen the three screws that fix the white shade disk 2- Unscrew the silica gel cartridge using a coin 3- Remove the cartridge perforated cap 4- Open the sachet containing silica gel (supplied with the pyranometer) 5- Replace the silica gel crystals 6- Close the cartridge with its own cap, paying attention that the sealing O-ring be properly positioned. 7- Screw the cartridge to the pyranometer body using a coin 8- Check that the cartridge is screwed tightly (if not, silica gel life will be reduced) 9- Position the shade disk and screw it with the screws 10- The pyranometer is ready for use Figure N.1 shows the operations necessary to fill the cartridge with the silica gel crystals. Silica-gel cartridge LP SG Sealed sachet of silica Perforated Cap A B LP G Filling Closing the cartidge C Fig. 1 D PYRA 02 pyranometer is to be mounted in an easy-to-reach location in order to clean the dome regularly and carry out maintenance. At the same time, make - 3 -

sure that no buildings, constructions, trees or obstructions exceed the horizontal plane where the pyranometer lies. If this is not possible, select a site where obstructions in the path of the sun from sunrise to sunset do not exceed 5 degrees of elevation. N.B The presence of obstructions on the horizon line affects significantly the measurement of direct irradiance. The pyranometer is to be located far from any kind of obstruction, which might reflect sunlight (or sun shadow) onto the pyranometer itself. In compliance with ISO TR9901 standard and WMO recommendations, when the pyranometer is used without the white shade disk, it is to be positioned so that its connector is pointed to the North Pole, if the instrument is used in the Northern Hemisphere, and to the South Pole, if used in the Southern Hemisphere. In any case, it is better to follow this suggestion even when the shade disk is applied. is provided with a spirit level for carrying out an accurate horizontal leveling. The adjustment is made by means of two leveling screws that allow to adjust the pyranometer inclination. Use the two 6mm-diameter holes and a 65mm interaxial distance to mount the instrument on a plane. Remove the shade disk to access the holes and reposition it after mounting (see fig. 2). In order to make the installation of pyranometer easier Delta Ohm supplies on request a series of fittings as per fig. 3. The operator shall take care that the mast height does not exceed the pyranometer plane to avoid measurement errors caused by any reflection or shadow of the mast itself. To fix the pyranometer to the mounting bracket, remove the shade disk loosening the three screws, fix the pyranometer, and mount the white shade disk again. It is suggested to thermally isolate the pyranometer from its mounting brackets, and to check that the electrical contact with the ground be done properly. - 4 -

D 6 mm Fixing holes 65.0 mm 79.0 mm 165 mm AC AV 50.0 mm Spirit Level 104 mm 103 mm 120 mm HD9906.47 HD9906.46 HD9906.47.2 HD9906.46.2 Fig 2 HD 2003.77 HD 2003.84 HD 2003.85 HD 2003.79 HD 2003.83 HD 2003.77C LP S1 Pyranometer with LP S1 Fig. 3-5 -

4 Electrical Connection and Requirements for Electronic Readout Devices: is produced in 3 versions,, AC and LP PYRA 02 AV. pyranometer is passive and it does not require any power supply. AC, AV are active and need power supply. Required voltage is as follows: 8-30 Vcc for AC and AV with 0..1V and 0..5V autput supply. 14-30 Vcc for AV with 0..10 V output. All version are supplied with a 4 pole connector. The optional cable is terminated with a connector at one end and it is made of PTFE UV-proof. It is provided with 3 wires and a braided wire (shield). Cable colors and connector poles are matched as follow (figure 4): Fig.4 Connector Function Color A Shield ( ) Black B Vout (+) Red C Vout (-) Blue D Housing ( ) White AC Connector Function Color A Shield ( ) Black B Positive (+) Red C Negative (-) Blue D Housing ( ) White AV Connector Function Color A Shield ( ) Black B (+) Vout Red C (-) Vout e (-)Vcc Blue D (+) Vcc White - 6 -

pyranometer is to be connected either to a millivoltmeter or to a data acquisition system. Typically, the pyranometer output signal does not exceed 20 mv. In order to better exploit the pyranometer features, the readout instrument should have a 1μV resolution. Thermopile Case - + Surge Arrestor Blue C Red B White D Shield (Black) A fig. 5 AC is to be connected to a DMM and a power supply as show below (Figure 5).To read the signal, the load resistance must be 500Ω AC +Vcc I out B C Power Supply + - - + DMM Fig. 6 AV is to be connected to a DMM and a power supply as show below (Figure 6). To read the signal, the load resistance must be 100kΩ AV +Vout -Vcc, - Vout + Vcc B C D + DMM - - Power Supply + Fig. 7-7 -

5 Maintenance: In order to grant measurement high accuracy. It is important to keep the outer glass dome clean. Consequently, the more the dome will be kept clean, the more measurements will be accurate. You can wash it using water and standard papers for lens, and if necessary using pure ETHYL alcohol. After using alcohol, clean again the dome with water only. Because of the high rise/fall in temperature between day and night, some condensation might appear on the pyranometer dome. In this case the performed reading is highly over-estimated. To minimize the condensation growth, the pyranometer is provided with a cartridge containing dessicant material: Silica gel. The efficiency of the Silica gel crystals decreases in the course of time while absorbing humidity. Silica gel crystals are active when their color is yellow, while they turn blue as soon as they loose their power. Read instructions at paragraph 3 about how to replace them. Silica gel typical lifetime goes from 2 to 6 months depending on the environment where the pyranometer works. 6 Calibration and Measurements: The pyranometer S sensitivity (or calibration factor) allows to determine global irradiance by measuring a signal in Volts at the thermopile ends. The S factor is measured in μv/(wm -2 ). Once the difference of potential (DDP) has been measured at the ends of the sensor, the E e irradiance is obtained applying the following formula: E e = DDP/S where; E e : is irradiance expressed in W/m 2, DDP: is the difference of potential expressed in μv measured by the multimeter, S: is the calibration factor in μv/(w/m 2) shown on the pyranometer label (and mentioned in the calibration report). AC The pyranometer sensitivity is set so that: 4..20 ma = 0..2000 W/m 2 To obtain irradiance the following procedure is to be applied: -once you know the current ( I out ) absorbed by the instrument and measured with the DMM, following formula must be applied: ( I ma) E e= 125 4 where; E e : Irradiance in W/m 2, I out : current in ma absorbed by the pyranometer out - 8 -

AV The pyranometer sensitivity is set so that according to the version: 0..1 V = 0..2000 W/m 2 0..5 V = 0..2000 W/m 2 0..10 V = 0..2000 W/m 2 To obtain irradiance the following procedure is to be applied: -once you know the instrument output voltage (V out ) measured with the DMM, following formula must be applied: E E E =2000 for the version 0 1 V e V out =400 for the version 0 5 V e V out =200 for the version 0 10 V e V out where; E e : Irradiance in W/m 2, V out : Output voltage (in Volt) measured by the voltmeter Each Pyranometer is factory calibrated it is marked by its own calibration factor. To exploit all Features it is highly recommended that the calibration be checked annually. The instruments and the equipment of Delta Ohm Photometry-Radiometry meteorological laboratory grant the calibration of pyranometers according to the WMO specifications and ensure that measurements are traceable to the international standards. 7 Technical Specifications: itivity: Typival Sensitivity: 10 μv/(w/m 2 ) 4..20 ma (0-2000 W/m 2 ) AC 0..1,5,10V (0-2000 W/m 2 ) AV Impedance: 33 Ω 45 Ω Measuring range: 0-2000 W/m 2 Viewing angle: 2π sr Spectral range: 305 nm 2800 nm (50%) (dome transmission) 335 nm 2200 nm (95%) Operating temperature: -40 C 80 C Dimensions: Figure 1 Weight: 0.90 Kg - 9 -

Technical Specifications According to ISO 9060 1- Response time: <28 sec (95%) 2- Zero Off-set: a) response to a 200W/m 2 thermal radiation: <15 W/m 2 b) response to a 5K/h change in ambient temperature: < ±4 W/m 2 3a- Long-term non-stability: < ±1.5 % (1 year) 3b- Non-linearity: < ±1 % 3c- Cosine response: < ±18 W/m 2 3d- Spectral selectivity: < ±5 % 3e- Temperature response: <4 % 3f- Tilt response: < ±2 % - 10 -

8 Ordering Codes ORDERING CODE ARTICLE AC AV CP AA 1.5 CP AA 1.10 HD 2003.85 HD 2003.79 HD 2003.77 LP SP1 LP S1 First Class Pyranometer according to ISO 9060. Complete with shade disk, desiccant sachet with silica gel crystals, 2 silicagel cartridges, spirit level, 4 pole plug and Calibration Report. First Class Pyranometer according to ISO 9060. Complete with shade disk, desiccant sachet with silica gel crystals, 2 silicagel cartridges, spirit level, 4 pole plug and Calibration Report. 4..20 ma signal Output First Class Pyranometer according to ISO 9060. Complete with shade disk, desiccant sachet with silica gel crystals, 2 silicagel cartridges, spirit level, 4 pole plug and Calibration Report. 0..1V, 0..5V, 0..10V signal output (to be defined when order) 4 pole plug with UV proof cable, L=5m. 4 pole plug with UV proof cable, L=10m. Fixing kit to mount height pyranometer on φ 40mm mast (HD2003.84 + HD2003.85 + HD2003.79) Fixing kit to mount pyranometers on clamping φ 40mm (HD2003.77 + HD2003.79) Clamping for mast φ 40mm UV resistant plastic shade disk (BASF LURAN S777K) Mounting kit for : bracket for attachment to a mast, including fasteners and leveling screws. LP SG Desiccant sachet with silica gel crystals, complete with inner O-ring and cap. LP G Pack of 5 cartridges of silica gel crystals - 11 -

GARANZIA GARANTIE GUARANTEE GARANTIA GUARANTEE CONDITIONS All DELTA OHM instruments have been subjected to strict tests and are guaranteed for 24 months from date of purchase. DELTA OHM will repair or replace free of charge any parts which it considers to be inefficient within the guarantee period. Complete replacement is excluded and no request of damages are recognized. The guarantee does not include accidental breakages due to transport, neglect, incorrect use, incorrect connection to voltage different from the contemplated for the instrument. Furthermore the guarantee is not valid if the instrument has been repaired or tampered by unauthorized third parties. The instrument has to be sent to the retailer without transport charge. For all disputes the competent court is the Court of Padua. This guarantee must be sent together with the instrument to our service centre. N.B.: Guarantee is valid only if coupon has been correctly filled in all details. Instrument type Serial number RENEWALS Date Inspector Date Inspector Date Inspector Date Inspector Date Inspector Date Inspector RoHS 2002/95/EC CE CONFORMITY Safety EN61000-4-2, EN61010-1 LEVEL 3 Electrostatic discharge EN61000-4-2 LEVEL 3 Electric fast transients EN61000-4-4 LEVEL 3 Voltage variations EN61000-4-11 Electromagnetic interference susceptibility IEC1000-4-3 Electromagnetic interference emission EN55020 class B