A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

Similar documents
BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

Spectroradiometer characterisations for traceable solar radiation measurements

TRACEABLE SOLAR RADIATION MEASUREMENTS

BTS2048-VL-CP-ILED-B-IS-1.0-HL

The PMOD/WRC Precision Spectroradiometer PSR

Development of 2 Total Spectral Radiant Flux Standards at NIST

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

Program for UV Intercomparison 2014 in Davos:

We bring quality to light. MAS 40 Mini-Array Spectrometer

New automated laser facility for detector calibrations

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

Improving the Collection Efficiency of Raman Scattering

Maya2000 Pro Spectrometer

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

We bring quality to light. Spectro 320 Scanning Spectrometer

Broadbandradiometer specbos 1211

JETI Specbos Instruments

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

Section 1: SPECTRAL PRODUCTS

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

RAMSES. A modular multispectral radiometer for light measurements in the UV and VIS

Developement of the method for realization of spectral irradiance scale featuring system of

CIE 220:2016 Characterization and Calibration Method of UV Radiometers

Spectroradiometer specbos 1201

Fully Portable Spectrophotometer for Transmission Measurement

TriVista. Universal Raman Solution

SPECTRAL IRRADIANCE DATA

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Measuring optical filters

Optical In-line Control of Web Coating Processes

ROTATING SHADOWBAND SPECTRORADIOMETER MODEL RSS-1024/UVRSS-1024 BULLETIN RSS/UVRSS-1024

Experimental Analysis of Luminescence in Printed Materials

Miniature Spectrometer Technical specifications

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

LED Tester BTS256-LED

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Calibration of a High Dynamic Range, Low Light Level Visible Source

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

Company synopsis. MSU series

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

The FTNIR Myths... Misinformation or Truth

Instrumental and Methodological Developments in UV Research

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Miniaturized Spectroradiometer

Microscope-Spectrometer

Modern UV-curing technology

Influence of the light spectral distribution used in the radiometers calibration

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Observational Astronomy

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Application Note (A11)

The Physikalisch Meteorologisches Observatorium Davos, World Radiation Center (PMOD/WRC) Julian Gröbner

LEDMET Report: Simulation and correction of stray light in spectrometers

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Broadband detectors Mario Blumthaler

CU-LASP Test Facilities! and Instrument Calibration Capabilities"

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

UV-Index Photodiodes Data Sheets

Basic Components of Spectroscopic. Instrumentation

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

Ozone Absorption Cross Sections Laboratory Measurements

We bring quality to light. CAS 120 CCD Array Spectrometer

Spectral responsivity uncertainty of silicon photodiodes due to calibration spectral bandwidth

The Issues of Measurement of Optical Hazard Using Photometers EMRP JRP ENG05 Metrology for Solid State Lighting

A Laser-Driven Light Source (LDLS) as a portable spectral irradiance calibration source in the UV range and other radiometric applications.

Photometry for Traffic Engineers...

Content of this Catalog. General information about the sglux TOCONs. Selection guide p. 2. Product details of all TOCONs p. 5. Useful accessories p.

SpectraPro 2150 Monochromators and Spectrographs

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM

UV-Index Photodiodes Data Sheets

specification display & lighting hera spectrometer

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

GLOSSARY OF TERMS. Terminology Used for Ultraviolet (UV) Curing Process Design and Measurement

SPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Components of Optical Instruments 1

White Paper on SWIR Camera Test The New Swux Unit Austin Richards, FLIR Chris Durell, Joe Jablonski, Labsphere Martin Hübner, Hensoldt.

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

Photometry for Traffic Engineers...

Measuring the Light Output (Power) of UVC LEDs. Biofouling Control Using UVC LEDs

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

RGB Laser Meter TM6102, RGB Laser Luminance Meter TM6103, Optical Power Meter TM6104

Comparison of Quantum Sensors with Different Spectral Sensitivities

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

2008 Stray Light Correction Work

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Transcription:

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range Mike Clark Gigahertz-Optik GmbH m.clark@gigahertz-optik.de

Array spectroradiometers Array spectrometers used extensively in spectroscopy and optical radiation applications Fast measurements Solid state Cost effective Flexibility 2

Array spectroradiometers entrance optics Spectroradiometer - instrument for measuring radiometric quantities in narrow wavelength intervals over a given spectral region. (CIE definition) Entrance optic determines what radiometric quantity can be measured e.g. :- Calibration standard Entrance optic Spectrometer Cosine diffuser Spectral irradiance W/(m² nm) Integrating sphere Spectral radiant flux W/nm F.O.V. optic Spectral radiant intensity W/(sr nm) 3

Array spectroradiometers - calibration 30W D2 1000W FEL Tungsten halogen and deuterium lamps commonly used but both have their limitations Calibration source needs to be suitable for required radiometric quantity and entrance optic 4

What is Stray light? Stray light is signal that is detected during a spectroradiometer measurement in addition to the real signal. Measured Real 200nm 250nm 300nm 350nm 400nm 450nm 500nm Spectral irradiance mw m -2 nm -1 550nm 10 2 10 1 10 0 10-1 10-2 10-3 10-4 The amount of stray light in a measurement strongly depends on the light source and the spectrometer itself. 5

Stray light causes Possible causes of internal stray light: Scatter from the diffraction grating Reflections and scatter from 0 th order Higher orders of diffraction Double diffraction Scatter from imperfect mirrors Inter-reflections between optical components Diffuse reflections within housing Optically over-filling entrance aperture Fluorescence Array detector 6

Out of Range stray light Each pixel in an array detector is sensitive to all wavelengths in the detector s range Back-thinned CCDs can offer good efficiency in UV 200-400nm Conventional detector technologies (Si-based) have high responsivity well beyond UV Results in Out of Range stray light 7

Significance of stray light for UV measurements Biological action spectra have wide dynamic ranges Common sources e.g. sunlight (*) relatively high proportion of visible + NIR radiation 10 1 0,1 0,01 0,001 Actinic UV Erythema NMSC Vit-D 0,0001 (*) Note very sharp rising edge 0,00001 200 250 300 350 400 Calibration factors inversely proportional to responsivity Therefore, stray light component increasingly significant in deep UV 8

Double monochromators Double monochromators often specified as reference instruments B.1.1 Double monochromator: Recommended instrument The measurement of a source for the purpose of hazard classification requires accuracy during calibration and testing. The detector s broad spectral response and high spectral resolution required to provide accurate weighting leads to stringent requirements for out-of-band stray light rejection... The ratio of out-of-band energy to pass-band energy at 270 nm for tungsten or tungsten-halogen calibration lamps should be smaller than 10-4. The double monochromator is the only instrument that provides the needed selectivity, and it is recommended for hazard measurements involving UV and visible radiation. It is recognized that monochromator systems introduce limitations in convenience and speed. Use of a single monochromator in the UV or visible spectrum should be used only if comparable results to that from a double monochromator can be obtained.. Two monochromators in series, first acts as a pre-filter. Limited stray light enters second monochromator. Mechanical scanning. Single element detectors only (e.g. PMT) No array detector meaningful at exit of double. 9

Stray light suppression in array spectroradiometers Good optical design e.g. use of optical simulation raytracing software. Diffraction grating e.g. holographic grating cf. ruled grating Optical component selection e.g. mirror surface quality Instrument housing design e.g. materials used, size, shape 10

Mathematical corrections Tuneable lasers (OPOs) enable spectrometers to be characterized at any wavelength. 430nm Line Spread Functions (LSF) form a signal distribution function (SDF) characterization matrix of the spectrometer. Wavelength OPO /nm 200nm 200nm Detector signal /nm 430nm LSF matrix representation LSF of spectroradiometer measured using an OPO The SDF data and the measurement data from the light source under test enable the use of mathematical correction methods according to (Zong et al., 2006) or (Nevas et al., 2012). Zong Y, Brown S W, Johnson B C, Lykke K R and Ohno Y 2006 Simple spectral stray light correction method for array spectroradiometers Appl. Opt. 45 1111-9 Nevas S, Wübbeler G, Sperling A, Elster C and Teuber A 2012 Simultaneous correction of bandpass and stray-light effects in array spectroradiometer data Metrologia 49 S43 11

Stray light matrix correction Possible to reduce stray light by between 1 and 2 orders of magnitude Mathematical stray light correction applied to a white LED measurement Mathematical correction must be performed for every measurement An OPO is required in order to perform the measurements precisely Spectroradiometer must be stable (time and temperature) for SDF matrix to work Small wavelength shift is very significant w.r.t. stray light matrix 12

Limitations of mathematical corrections Optimum stray light suppression requires the LSFs to be measured over the entire spectral sensitivity range of the detector Holographic grating 1800g/mm 230nm blaze Back-thinned CCD UV optimised grating (e.g. 200 nm to 400 nm) only permits a minor part of the stray light to be corrected Stray light beyond 400 nm (Out of Range, OoR) cannot be corrected with this method! 13

Use of filters Long-pass filter Schott GG435 Bandpass filters Schott UG Use of long-pass filter (e.g. Schott GG435) determines OoR stray light during calibration. But subsequent measurements likely to have different stray light Interference bandpass filters Bandpass filters can significantly reduce potential for stray light akin to first half of a double monochromator Perfect bandpass filters not available (e.g. out of band transmission, narrow and low passband transmission) 14

BTS2048-UV-S stray light corrected spectroradiometer 1. Optical radiation 2. Cosine diffuser 3. Filter wheel (*) 4. BiTec sensor 5. Electrical connectors 6. Microprocessor for data processing and communication BTS2048-UV-S (*) BTS technology Integral photodiode (SiC) + CCD spectrometer https://www.gigahertz-optik.de/en-us/serviceand-support/knowledge-base/bts-technology/ A miniaturized filter wheel holds a set of up to 6 different optical bandpass and longpass filters. Optimized stray light-reduced spectra result from the smart combination of submeasurements. Integration time 2 μs - 60 s Spectral range (190-430) nm Optical bandwidth 0.8 nm Pixel resolution ~0.13 nm/pixel Number of pixels 2048 Chip Back-thinned CCD chip, 1stage cooled ADC 16bit (25 ns instruction cycle time) Dynamic range >9 Magnitudes Peak wavelength ± 0.05 nm Band-pass correction mathematical online Linearity completely linearized chip >99.6% 15

PTB characterization of BTS2048-UV-S Device characterization undertaken by PTB e.g. wavelength accuracy, radiometric accuracy, linearity, stray light rejection, bandpass function, etc. Bandpass function around centroid λ c for different wavelengths with bandwidth (FWHM, dashed lines) indicated. 16

BTS2048-UV-S-WP Solar irradiance measurements Measurement of solar radiation in UV-B is particularly challenging conventionally the domain of double monochromators Ozone Hole was first announced in a paper by British Antarctic Survey s Joe Farman, Brian Gardiner and Jonathan Shanklin, which appeared in the journal Nature in May 1985. Instrument specification requirements developed in 1990 s. Therefore, a good quality test! Comparison of a solar measurement with BTS2048-UV-S-WP and a double monochromator illustrates the high dynamic range of the stray light corrected array spectroradiometer 17

TOC inter-comparison Izaña Total Ozone Measurements Inter-comparison at Izaña Tenerife, Sep 12th 30th, 2016 Izaña Atmospheric Research Center in conjunction with World Radiation Center (PMOD-WRC) BTS2048-UV-S mounted on a solar tracker Ground-based spectroradiometer measurements of direct solar UV irradiance can be used to determine the Total Ozone Column (TOC) by applying the Beer-Lambert law in conjunction with the known absorption characteristics of ozone over the 290-350nm wavelength range. Suitable modelling is required to minimise the influences of other atmospheric attenuators [1]. [1] Vaskuri, A., Kärhä, P., Egli, L., Gröbner, J., and Ikonen, E.: Monte Carlo method for determining uncertainty of total ozone derived from direct solar irradiance spectra: Application to Izaña results, Atmos. Meas. Tech. Discuss., https://doi.org/10.5194/amt-2017-403 18

TOC inter-comparison measurement results The measured spectra and integral values showed good agreement to the results of the double monochromator based QASUME (*) reference system. The performance (stray light suppression, absolute radiometric precision and wavelength precision) was proven by calculating the total ozone column from direct solar measurements The results showed deviations of the TOC of less than 1.5 % to other well established instruments. (*) QASUME - transportable reference spectroradiometer for Quality Assurance of Spectral Ultraviolet Measurements in Europe https://doi.org/10.5194/amt-2017-240 19

UV LED measurement Is stray light correction needed for simple routine measurements of UV LEDs? Optical bandwidth difference only 20

UV LED measurement The need for stray light suppression varies depending on application. BTS2048-UV-S BTS2048-UV 21

Proven UV performance - applications Solar measurements excellent stray light suppression, dynamic range and linearity is absolutely essential. Photobiological safety measurements excellent stray light suppression, dynamic range and linearity is absolutely essential e.g. for IEC EN 62471 and 2006/25/EC High power UV measurements i.e. UV curing and disinfection / water treatment - high dynamic range and linearity required as typical calibration sources have comparably low spectral power BTS2048-UV-S with fibre coupling option UV LED measurements excellent reference instrument, highest accuracy, suitable in presence of external stray light (e.g. room light) 22

Conclusion With appropriate stray light suppression techniques, compact array spectroradiometers can match the performance of traditional double monochromators making them suitable for many of the most demanding UV spectroradiometry applications. Their compactness and robustness offers new levels of speed, convenience and flexibility. They are well suited for use as reference grade instruments as well as providing accuracy and reliability for more routine measurements. 23

Thank you for your interest and attention Mike Clark m.clark@gigahertz-optik.de Acknowledgements 24