ISOLATED AC/DC POWER SUPPLY

Similar documents
ANALOG SCALING MODULE

PHASE CUT SIGNAL DRIVERS

SIGNAL INTERFACE MODULE

CAP6637A AC-DC Open Loop Converter

DCIM SIGNAL CONVERTERS

PROGRAMED ANALOG CONTROL MODULE

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

MODEL AT-10 ANALOG TRANSMITTER

Installation and Operating Manual

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

Operation and Maintenance Manual

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

INSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Electro Controls. Input-Output Modules WattsIndustries.co.uk

UNIVERSAL INPUT TO PULSE CONVERTER MODULE

Installation, Operation and Maintenance Instructions

SPECIFICATION, CONTROLS AND ACCESSORIES

Switching Power Supply Type SPP1 60W Enclosed type

WATT TRANSDUCER. Instruction Manual

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

DPS Series 5W, 10W, 18W AC/DC DIN Rail Power Supplies

4-20mA, 0-10V and general process measuring bargraph displays

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

SPECIFICATION, CONTROLS AND ACCESSORIES

MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

AMC mA Positioner

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

10. High Boost HAM. Maxi, Mini, Micro Design Guide Rev 4.9 vicorpower.com

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

DB Motorized Impeller

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

1 INTRODUCTION ORDER CODE / INFORMATION

DB Motorized Impeller

Differential pressure sensors

DB Motorized Impeller

PART # mA Positioner

DO NOT USE UNIT POWER

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

B850 Boiler House Energy Monitor

Meriam Model M ma Loop Calibrator Operating Instructions

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Multimeter Definition

ELKOR MOC1 TRANSDUCER SET - MANUAL

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

10000W Single Output Power Supply. Features. Applications. Description. Model Encoding RST

MODEL 421 Over/Under Motor Load Monitor

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

269 Troubleshooting Guide 11/4/98 1

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

S11 Adjustable Speed Drive Engineering Specification

600W Single Output Switching Power Supply HLG-600H-xx0ADM series IP65 IP67. File Name:HLG-600H-SPEC

Remote Site Monitoring

LINEAR LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

HLG-600H series IP65 IP W Single Output Switching Power Supply. File Name:HLG-600H-SPEC

VariTrans P D1 TRMS

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

UNIVERSAL INPUT RESISTANCE OUTPUT

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

CURRENT/FREQUENCY CONVERTER S 104

Technical data sheet 1671 Power amplifier Art. no 19611

Measurement Board Product Number:

Sealed Interface Control: EC20300

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

ADVR-16. Hybrid Universal Analog Digital Voltage Regulator Operation Manual. Self Excited 16 Amp Analog / Digital Voltage Regulator

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

Non-Spring Return EconoDrive Proportional Actuator

PSU12SA Power Supply Unit for Active Amplification System

Precision Frequency To Voltage Converter Card

VF-nC1 Adjustable Speed Drive Engineering Specification

Note The module converts unipolar and bipolar input signals

Installation guide 971 SmartRadar LTi

TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher

SINEAX / EURAX 2I1 Passive DC signal isolator

perfection by simplicity Catalogue

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

TI25 - Pre-Instructional Survey

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

Power Supplies 3. SDN-C Compact DIN Rail Series

FREQUENCY-CONVERTER MFR 600A

AUDIO SIGNAL CONVERTER

Dimensions in inches (mm) .268 (6.81).255 (6.48) .390 (9.91).379 (9.63) .045 (1.14).030 (.76) 4 Typ. Figure 1. Typical application circuit.

Emergency lighting units EM powerled

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

DC Current Transducers

600W Single Output Switching Power Supply HB-600 series IP65 IP67 SELV. Features. Applications. Description. Model Encoding HB A

HLG-600H IP65 IP67. series. 600W Single Output Switching Power Supply. Features. Applications

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

UNIVERSAL PNEUMATIC TRANSDUCER FEATURES

POWER SUPPLY MODEL XP-720. Instruction Manual ELENCO

B850 Boiler House Energy Monitor

Power Supplies Supplying power for your industrial applications

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION

Transcription:

FEATURES IPS-2/24 Transformer isolation Selectable voltage outputs Thermal overload protected Fused outputs Snap track mounted APPLICATIONS AC power isolation Isolated DC power supply 2, 3 & 4 wire transmitter supply ± DC power supply DESCRIPTION & OPERATION The IPS-2, or IPS-4 provides the isolation needed for position reference 4-20mA transmitters. It can also be used for AC isolation or ± voltage power supply. The IPS-2 uses a 24VAC/20VAC transformer. The 250mA outputs are sufficient for most isolation and transmitter needs. The IPS comes mounted in 3" wide snap track. SINGLE CHANNEL SCHEMATIC Power is applied to the isolation transformer's primary. The secondary voltage is fused and provides a 20VAC at 250Ma AC output. The fused secondary voltage is then rectified and filtered. Voltage regulator (LM317T) is biased by resistors R1 and jumpers selected R3, R5, R7, or R9 for output voltages 5, 6, 15, or 24VDC respectively. The trim potentiometer (P1) allows for a fine output voltage adjustment (clockwise to increase). The LM317T employs internal current-limiting and thermal-shutdown protection to protect from short circuits. SPECIFICATIONS SIZE: IPS-2 3"W x 3"L x 1.5"H IPS-4 3"W x 6"L x 1.5"H MOUNTING: IPS-2 3 RDI snap track (supplied) IPS-2 6 RDI snap track (supplied) POWER: FUSE REQ: 24VAC ± 10%, 50/60Hz IPS-2 20VA @ full load IPS-4 40VA @ full load 120VAC is available also 2AG.25 Amp (1 per channel) Littlefuse #229.250 OUTPUT SIGNALS: Jumper selectable ranges 5VDC 100mA 6VDC 100mA 15VDC 175mA 24VDC 250mA REGULATION: ± 15m VDC AMBIENT TEMP: 0 TO 50 C WIRINGE CONFIGURATION IPS-4/24

OUTPUT CODE OPTIONS PHYSICAL CONFIGURATION OUTPUT WATTAGE CODE OPTIONS 2 Two isolated outputs, AC or DC 2C Two custom isolated outputs One AC output and one AC or DC output. 2AC Two isolated AC outputs only 4 Four isolated outputs, AC or DC 4C Four custom isolated outputs, Two AC outputs and two AC or DC outputs. 4AC Four isolated AC outputs only PRIMARY AC VOLTAGE OPTION CODES 120 110-120VAC Primary Voltage 24 24VAC Primary Voltage ORDERING CODE EXAMPLES IPS-2/120 IPS-4/24 IPS-2C/24 IPS-2AC/120 110-120VAC Primary voltage with two selectable DC outputs 24VAC Primary voltage with four selectable DC outputs 24VAC Primary voltage with one AC output and one selectable DC output 110-120VAC Primary voltage with two 24VAC outputs only PHYSICAL CONFIGURATION IPS-4

APPLICATION 1 ISOLATED POWER FOR NARROW RANGE SENSORS The IPS-2 isolated DC power supply is used to maintain the input isolation from the 24VAC line and provide 4 selectable voltage ranges to power various temperature sensors and 4-20mA transmitters. APPLICATION 2 ISOLATED + 5V POWER SUPPLY FOR DIM-2 INDICATORS It is often required to provide multiple panel indication meters for various signal ranges. The IPS-2 has 4 selectable voltage ranges and a fine adjust trimmer per output channel to power multiple DIM-2 indicators and other DC devices. APPLICATION 3 POWERING 2 WIRE DWYER PRESSURE TRANSMETTERS Often a 24VDC supply is required to power a number of 4-20mA transmitters such as the Dwyer 600 series. The IPS-2 eliminates the need for a separate 24VAC transformer and can provide 24VDC @ 250mA to power up to 8 current loop transmitters simultaneously.

APPLICATION 4 POWERING 3 WIRE DWYER PRESSURE TRANSMITTERS When using Dwyer s 606 3 wire 4-20mA transmitter, a separate 24VDC supply is needed for each transmitter. This is because the 606 is a positive referenced device, with +24VDC supply connecting to controller signal input and 606 red wire. The 24VDC supply common connects to 606 black wire, and the 606 signal common (green wire) connects to input common with a 250V load resistor connected between signal input and signal common. APPLICATION 5 POWERING 4 WIRE 24VAC DWYER PRESSURE TRANSMITTER Often when powering a Dwyer 4 wire pressure transmitter, a 24VAC isolated AC supply is required to avoid ground loops with different pieces of equipment. The IPS-2AC provides two isolated 24VAC outputs rated for loads up to 250mA AC

APPLICATION 6 POWERING 3 WIRE VERIS HD2XVSX HUMIDITY TRANSMITTERS When using Veris humidity 3 wire 4-20mA transmitters & the Siemens Predator controller, a separate 24VDC supply is needed for each transmitter. This is because the input commons on the controller are not common to each other and thus one signal can effect to other.