Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Similar documents
Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

Keysight U1231A/ U1232A/U1233A Handheld Multimeter. Quick Start Guide

Agilent U1211A, U1212A, and U1213A Clamp Meter. Quick Start Guide U1211A U1212A U1213A

Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester

Keysight U1241C/ U1242C Handheld Digital Multimeter. Quick Start Guide

Agilent U1251A and U1252A Handheld Digital Multimeter

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

USER'S MANUAL DMR-6700

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MS2030 CAT III 600 V A V AUTO RS232

400Amp True RMS AC/DC Clamp Meter Model EX613

Autoranging Multimeter Extech EX503

1.General instructions Specifications Description...7

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DVM1190 DIGITAL MULTIMETER

Compact MultiMeters + Voltage Detector

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Dawson DDM190. Digital Multimeter User s Manual

AMM-1022 Digital Multimeter USER`S MANUAL

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Agilent U1253B True RMS OLED Multimeter

AX-C Introduction. 2. Safety Information

AC/DC CLAMP METER USER S MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

OPERATING INSTRUCTION

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Agilent U1251B and U1252B Handheld Digital Multimeter

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

User s Guide. 400A AC/DC Clamp Meter. Model MA220

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

400Amp True RMS AC Clamp Meter + NCV

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

Digital MultiMeter - Make your job efficiency User Instruction Manual

True RMS Digital Multimeter Model:

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Pocket Size Digital Multimeter with USB Model: A & A

Agilent U1251A and U1252A Handheld Digital Multimeter

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

OPERATOR S INSTRUCTION MANUAL

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DM-45 Digital Multimeter

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

True-RMS Digital Multimeter User Manual

200Amp AC Clamp Meter + NCV Model MA250

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Fluke 123/124 Industrial ScopeMeter

Digital Clamp Meter Model: &

Not for Reproduction

User Manual Digital Multimeter

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Keysight U1273A/U1273AX Handheld Digital Multimeter

Keysight U1253B True RMS OLED Multimeter

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

DIGITAL CLAMP METER Use s Manual

Agilent U1273A/U1273AX Handheld Digital Multimeter

770E DIGITAL MULTIMETER OPERATOR S MANUAL

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Keysight U1253B True RMS OLED Multimeter

BENCH METER Model>9803. Wavecom Instruments

Keysight U1273A/U1273AX Handheld Digital Multimeter

DIGITAL MULTIMETER INSTRUCTION MANUAL

Digital automotive analyser 13 function with ic

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

M-1000D DIGITAL MULTIMETER

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

PCMT20 PYLE C;",D J WWWPYLEAUDIO.COM

The Meter Structure The Figure 2-1 shows the Meter structure.

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

Model 77 Series IV. Digital Multimeter. Users Manual

Digital Automotive Analyser 14 Function With IC

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

User Manual Digital Multimeter. model no.: MSR-U1000

Keysight U1241B and U1242B Handheld Digital Multimeters

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

Digital Clamp Meter. User Manual

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Transcription:

Agilent U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 8.4 V battery Power cord and AC adapter Certificate of Calibration If anything is missing or damaged, please contact the nearest Agilent Sales Office. For more detailed information, please refer to the Agilent U1253B True RMS OLED Multimeter User s and Service Guide on Agilent Web site (www.agilent.com/find/handheld-tools). WARNING Ensure the terminal connections are correct for that particular measurement selection before starting any measurement. To avoid damage to the device, do not exceed the input limit. Agilent Technologies

Charging the Battery It is strongly recommended that you use the specified 24-volt DC adapter included as an accessory to charge the rechargeable battery. 1 Remove the test leads from the multimeter and turn the rotary switch to. 2 Plug the DC adapter into a power outlet. 3 Insert the red (+) and black ( ) banana plugs (4 mm plugs) of the DC adapter to the and terminals respectively. Ensure that the polarity of the connection is correct. 4 The display will show a countdown timer of 10 seconds for the self-test to start. The multimeter will output short single-tone sounds to remind you to charge the battery. Press to start charging the battery, or the multimeter will automatically start charging after 10 seconds. It is recommended not to charge the battery if the battery capacity is over 90%. NOTE For the battery charger, the main supply voltage fluctuations must not exceed ±10%. CAUTION Do not rotate the rotary switch from position when charging the battery. Perform battery charging only with 7.2 V or 8.4 V NiMH rechargeable battery, 9 V size. Disconnect test leads from all the terminals when charging the battery. Ensure proper insertion of battery in the multimeter, and follow the correct polarity. A new rechargeable battery comes in a discharged condition and must be charged before use (refer to the U1253B User's and Service Guide for charging instructions).

CAUTION Upon initial use (or after a prolonged storage period), the rechargeable battery may require three to four charge/discharge cycles before achieving maximum capacity. To discharge, simply run the multimeter under the rechargeable battery's power until it shuts down or the low battery warning appears. The multimeter may indicate that charging is complete after ten minutes when charging a new rechargeable battery. This is a normal phenomenon with rechargeable batteries. Remove the rechargeable battery from the device, reinsert it, and repeat the charging procedure. Functions and Features Action Steps Changes the OLED brightness Press. Freezes the measured value Press. Starts MIN MAX AVG NOW recording Offsets the measured value Press. Changes the measurement range Press. Press and hold for > 1 s. Turns on auto range Press and hold for > 1 s. Turns on dual display Press. Starts manual data logging Press and hold for > 1 s. Views the logged data Press for > 1 s, press or to scroll through the logged data. Clears the logged data Press for > 1 s, press for > 1 s. NOTE Your multimeter is capable of remote data logging. To use this feature, you will need an IR-USB cable (U1173A, purchased separately) and the Agilent GUI Data Logger Software (downloadable from www.agilent.com/find/hhtechlib).

Input Terminals and Overload Protection Measurement Functions Input Terminal Overload Protection Voltage COM 1000 Vrms Diode 1000 Vrms Resistance Capacitance Temperature Current (μa and ma) µa.ma COM < 0.3 A short circuit current 440 ma/1000 V 30 ka/fast-acting fuse Current (A) A COM 11 A/1000 V 30 ka/fast-acting fuse

Performing Voltage Measurements Measuring AC voltage 1 Set the rotary switch to. For and mode, press to ensure is shown on the display. 2 Connect the red and black test leads to input terminals V. mv (red) and COM (black) respectively. 3 Probe the test points and read the display. 4 Press to display dual measurements. Parameter can be switched consecutively. Measuring DC voltage For measuring DC voltage from a NOTE mixed signal in DC measurement mode, ensure that the Filter is enabled 1 Set the rotary switch to or. Ensure that is shown on the display. 2 Connect the red and black test leads to input terminals V. mv (red) and COM (black) respectively. 3 Probe the test points and read the display. 4 Press to display dual measurements. Parameter can be switched consecutively.

Using the Filter 1 Press and hold for more than 1 second to enter the multimeter s Setup menu. 2 Press or to scroll to menu 6. 3 Press or to browse to the DC Filter option. 4 Press to enter the Edit mode. 5 Press or to enable the DC Filter. 6 Press for more than 1 second to save your changes and exit the Edit mode. 7 Press and hold until the meter restarts and returns to its normal operating mode. CAUTION To avoid possible electric shock or personal injury, enable the Filter to verify the presence of hazardous DC voltages. Displayed DC voltages can be influenced by high frequency AC components and must be filtered to assure an accurate reading.

Performing Current Measurements To perform current measurements, set up your multimeter as shown in the figure below. For measuring DC current from a mixed signal in DC measurement mode, ensure that the Filter is enabled. Measuring AC current 1 Set the rotary switch to or. Press to ensure is shown on the display. 2 Connect the red and black test leads to input terminals µa.ma (red) and COM (black) or A (red) and COM (black) respectively. 3 Probe the test points in series with the circuit and read the display. Measuring DC current 1 Set the rotary switch to or. Ensure that is shown on the display. 2 Connect the red and black test leads to input terminals µa.ma (red) and COM (black) or A (red) and COM (black) respectively. 3 Probe the test points in series with the circuit and read the display. CAUTION If the current is 440 ma, connect the red and black test leads to input terminals µa.ma (red) and COM (black). If the current is > 440 ma, connect the red and black test leads to input terminals A (red) and COM (black).

Performing Resistance, Conductance, and Continuity Measurements PRESS SHIFT Audible continuity PRESS SHIFT 1 Set the rotary switch to. 2 Connect the red and black test leads to input terminals Ω (red) and COM (black) respectively. 3 Probe the test points (by shunting the resistor) and read the display. 4 Press to scroll through audible continuity ( / ), conductance ( ), and resistance tests (,, or ) as shown.

Performing Capacitance and Temperature Measurements Capacitance 1 Set the rotary switch to. 2 Connect the red and black test leads to input terminals (red) and COM (black) respectively. 3 Connect the red test lead to the positive terminal of the capacitor, and the black test lead to the negative terminal. 4 Read the display. Temperature 1 Set the rotary switch to. Press to select temperature measurement. 2 Connect the red and black test leads to input terminals (red) and COM (black) respectively. 3 Plug the thermocouple adapter (with the thermocouple probe connected to it) into input terminals (red) and COM (black). 4 Touch the measurement surface with the thermocouple probe. 5 Read the display.

Frequency and Frequency Counter Measurements Frequency Measurement During AC/DC voltage or AC/DC current measurements, you can measure the signal frequency by pressing at any time. Frequency Counter Measurement 1 Set the rotary switch to. 2 Press to select the frequency counter ( ) function. The default input signal frequency is divided by 1. This allows signals up to a maximum frequency of 985 khz to be measured. 3 Connect the red and black test leads to input terminals V (red) and COM (black) respectively. 4 Probe the test points and read the display. 5 If the reading is unstable or zero, press to select division of input signal frequency by 100 ( will be shown on the display). This accommodates a higher frequency range of up to 20 MHz. 6 The signal is out of the U1253B frequency measurement range of 20 MHz if the reading is still unstable after step 5. WARNING Use the frequency counter for low voltage applications. Never use the frequency counter on AC power line systems. For input more than 30 Vpp, you are required to use frequency measurement mode available under the current or voltage measurement instead of frequency counter.

Square Wave Output 1 Turn the rotary switch to. 2 Press to select duty cycle (%) on the primary display. 3 The default square wave frequency is 600 Hz as shown by the secondary display, with a 50% duty cycle as shown by the primary display. 4 Press or to scroll through the available frequencies (there are 28 frequencies to choose from). 5 Press or to adjust the duty cycle. The duty cycle can be set from 0.390625% to 99.609375%, in steps of 0.390625%. The displayed duty cycle has a resolution of 0.001%.

Safety Notices Safety Symbols CAUTION WARNING A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. CAT III 1000 V CAT IV 600 V Earth (ground) terminal Equipment protected throughout by double insulation or reinforced insulation Caution, risk of electric shock Caution, risk of danger (refer to the instrument manual for specific Warning or Caution information) Category III 1000 V overvoltage protection Category IV 600 V overvoltage protection Safety Information This meter is safety-certified in compliance with EN/IEC 61010-1:2001, UL 61010-1 Second Edition and CAN/CSA 22.2 61010-1 Second Edition, CAT III 1000 V/Category IV 600 V, Pollution Degree II. Use with standard or compatible test probes. For further safety information details, refer to the Agilent U1253B True RMS OLED Multimeter User s and Service Guide.

Printed in Malaysia U1253-90045 Fourth Edition, September 9, 2013 Agilent Technologies, Inc., 2009 2013 Agilent Technologies