MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE DTL. = DETAIL DIM. = DIMENSION EQ. = EQUAL FHWS. = FLAT HEAD WOOD SCREW = FRAME Hatch Patterns LBS. MAX. MIN. M.O. NA. OC. OPG. OPP. = POUNDS = MAXIMUM = MINIMUM = MASONRY OPENING = NOT APPLICABLE = ON CENTER = OPENING = OPPOSITE REQD. = REQUIRED = ROUGH OPENING SDS. = SELF-DRILLING SCREW = SIMILAR TOT. = TOTAL FRAME V.G. = VISIBLE GLASS VIF. = VERIFY IN WO = WINDOW OPENING PLYWOOD BRICK STEEL FOAM GYPSUM CONCRETE RIGID INSULATION SOLID WOOD CONCRETE BLOCK GROUT BATT INSULATION Symbols T = TEMPERED GLAZING L = LAMINATED P = PANEL I = IMPACT GLAZING O = OBSCURE GLAZING S = SPANDREL INDICATOR PARTIAL BLOCKING - DETAIL CUT CONTINUOUS BLOCKING BACKER ROD M -.- REINFORCEMENT SPRAY FOAM Components & Cladding Design Pressures Special Notes Construction Documents Received THESE DRAWINGS WERE PREPARED FROM THE FOLLOWING INFORMATION DATED ARCHITECTURAL PLANS COMPLETE SET 2-28- SPECIFICATIONS SECTIONS 08, 08 80 00 - ADDENDUM NONE - OTHER NONE - Mullion Reinforcement THIS REINFORCING DESIGN CONSIDERS WIND LOADING ON THE COMBINATION AND DEAD LOAD FOR PELLA PRODUCTS ONLY. FAILURE TO CONFIRM THESE DESIGN PRESSURES BY A LOCAL STRUCTURAL ENGINEER OR BUILDING OFFICIAL MAY RESULT IN INADEQUATE DESIGN OR SELECTION OF PRODUCTS. MARK # REINFORCEMENT TYPE MAX. END LOAD M. PELLA /2" IMPERVIA ALUMINUM W/ /" x 2 " STAINLESS STEEL 2 LBS M. (MIN. REQ'D) 8 GA. -/8x-/8 NESTED STEEL STUD (UNPUNCHED) 2 LBS END CONNECTIONS MUST NOT INTERFERE WITH FRAMES OR PLACEMENT. WALL CONSTRUCTION AND END CONNECTIONS MUST BE DESIGNED TO ACCEPT THE LOADS INDICATED. STEEL REINFORCEMENT MUST BE PRIMED & TOP COATED WITH QUALITY PAINT, USE FULL PENETRATION WELDS AT CONNECTIONS. 0 OF2
8'-0 " '-6 '-6 APPLIED '- 2" 6 CORNER M. M. 22'-0 " TOT. M. M. 2-- WA ORDER ITEM:, 6 2-0- '-0 8" TOT. 8'- 6" 2" 8'-0 2" 2" 8'- 6" APPLIED '-9 '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-9 6 " 6 " 8'-0 " '- 2" 6 M. M. M. M. M. M. M. M. 2 2 M. WB ORDER ITEM: 0,, 2 EXPANSION EXPANSION '- 8" TOT. 8'-0 6" 2" 8'-0 2" 2" 8'-0 6" APPLIED '-" '- 2" '- 2" '- 2" '- 2" '- 2" '- 2" '- 2" '- 2" '- 2" '- 2" '-" 9 6 " 9 6 " 8'-0 " '- 2" 6 M. M. M. 2 M. M. M. 2 M. M. M. WB ORDER ITEM: 0,, 2 EXPANSION EXPANSION 02 OF 2
8'-0 " '-6 '-6 APPLIED '- 2" 6 CORNER M. M. 22'-0 " TOT. M. M. '-8 " '-8" '-2" '-2" '-2" '-2" 6 M. 6'-0 " M. M. 2-- WC ORDER ITEM: 20, 2 2 WF ORDER ITEM: 2 8 2-0- 0'-9 " TOT. 0'-9 " TOT. 0'-9 " TOT. '-2 8" 2" '- 8" '-2 8" 2" '- 8" '-2 8" 2" '- 8" '- 2" '-" '- 2" '-" '- 2" '-" 2'- 2" '- 2" 2'- 2" '- 2" 2'- 2" '- 2" 8'-9 2" 8'-9" TOT. APPLIED 6'-9 '- 9 20 22 2 8 2 2 ORDER ITEM: 2, HL Level One ORDER ITEM: 0, 29 M. 2 ST FLR. M. PANEL 9 PANEL STONE 6 APPLIED HL Level Two W2 Awn L 2 ORDER ITEM: W2 Awn L ORDER ITEM: 8 SIDING STONE SIDING 2 0 SIDING STONE PANEL '- 2" '- 8" '- 8" TOT. '-6 2" 9'-0 8" 9'-0 8" TOT. 6'-9 2'-2 8" '- 2" '- 8" '- 8" TOT. '-6 2" 8'- 8" 8'-0 8" TOT. APPLIED 6'-9 2'- 8" HL Level Three ORDER ITEM: 0, 0 W2 Awn L ORDER ITEM: '- 2" '- 8" '- 8" TOT. '-6 2" NOTE: GENERAL CONTRACTOR TO VERIFY DOOR HINGING. 0 OF2
8'-0 " 8'-9 " TOT. APPLIED 6'-9 2'-0" '-2 8" 2" '- 2" 0'-9 " TOT. 2'- 2" '- 8" '-" '- 2" '- 2" '- 8" '- 8" TOT. '-6 2" '-6 2" '- 8" TOT. APPLIED '- 2" '- 8" '- 2" '- 8" '-" 0'-9 " TOT. 2'- 2" 2" '-2 8" '- 2" 6'-9 '- 8'-9" TOT. 8'-9 2" 2-0- 2-- HL Level Four ORDER ITEM:, 6 W2 Awn L ORDER ITEM: W2 Awn R ORDER ITEM: 22 HR Level One ORDER ITEM:, 29 0'-9 " TOT. 0'-9 " TOT. 0'-9 " TOT. '- 8" 2" '-2 8" '- 8" 2" '-2 8" '- 8" 2" '-2 8" '-" '- 2" '-" '- 2" '-" '- 2" APPLIED '- 2" 2'- 2" APPLIED '- 2" 2'- 2" APPLIED '- 2" 2'- 2" '-6 2" '- 8" TOT. '- 2" '- 8" W2 Awn R ORDER ITEM: 22 0 HR Level Two ORDER ITEM: 0, 6'-9 2'-2 8" 0 9'-0 8" TOT. 9'-0 8" '-6 2" '- 8" TOT. '- 2" '- 8" W2 Awn R 9 HR Level Three 6'-9 2'- 8" 8'-0 8" TOT. 8'- 8" '-6 2" ORDER ITEM: 22 ORDER ITEM:, 0 9 '- 8" TOT. '- 2" '- 8" W2 Awn R ORDER ITEM: 22 HR Level Four ORDER ITEM: 60, 6 6'-9 2'-0" 8'-9 " TOT. 8'-0 " 0 OF2
'-6 8" '- 8" TOT. '- 2" '- 8" '-" TOT. 2'- 2" '- " M. '- 2" '-6 8" '- 8" TOT. '- 2" '- 8" '-" TOT. 2'- 2" M. '- " '- 2" '-6 8" '- 8" TOT. APPLIED '- 2" '- 8" 2'- 2" '- 8" '-" 0'-9 " TOT. '- 2" M. M. 2" '-2 8" '- 2" '- 8" 2'-0" '- 8" TOT. '-6 8" '-6 8" '- 8" TOT. APPLIED '- 2" '- 8" 2'- 2" '- 8" '-" 0'-9 " TOT. '- 2" M. M. 2" '-2 8" '- 2" '- 8" 2'-0" '- 8" TOT. '-6 8" 2-0- 2-- W2 Awn L No Temp ORDER ITEM: 8 W2 Awn R no Temp ORDER ITEM: 220 W ORDER ITEM: 0, 2 2 2 W Awn R ORDER ITEM: 20, 2 '-0 " '-0 " 0'-0" TOT. 0'-0" TOT. 6'- " '-0" '-0" APPLIED 6'-0 8" 6'-9 2" '-0 8" 2'- 2" APPLIED '-0 8" 2'- 2" 2" 6'-0 8" 6'-9 6'- 2" TOT. 2'- 2" '-" '-6 8" '- 8" TOT. '- 2" '- 8" W R M. M. 2 ORDER ITEM: 2 '-6 8" '- 8" TOT. '- 2" '- 8" M. W L ORDER ITEM: 2 M. '-6 8" '- 8" TOT. '- 2" '- 8" W ORDER ITEM: 8 M. 6 '-0 " '-0" W Temp ORDER ITEM: 26 '-0 " 2 '-0" '-0 " '-0 " '-0" '-0" W ORDER ITEM: 2 2 '-6 " '- 2" '-6 " '- 2" '-6 " '- 2" '-6 " '- 2" W8 ORDER ITEM: 28 2 Operable Left ORDER ITEM: 20 8 Operable Right ORDER ITEM: 2 9 0 OF 2
TM0.0 AC0. AC.0 TM0.2 ROD & AC0.0 REQUIRED OVER SPREAD S TM0.2 ROD & SEE ELEV CC2.0 COVER " " CC2.0 COVER TM0.02 AC0.02 AC.0 TM0.2 ROD & " TM0.2 ROD & BC0.09 DETAIL KEYNOTES AC : ATTACHMENT COMPONENTS AC0.02 AC0.0 AC0. AC0.0 AC.0 AC.0 BC : BUILDING COMPONENTS (BY OTHERS) BC0.0 BC0.09 CC : COVERS CC2.0 IMPERVIA EXTERIOR COVER. SEE TYPICAL DETAIL T. SEAL TO WALL CONSTRUCTION AT HEAD AND JAMBS. DO NOT SEAL VERTICAL COVERS AT SILL TO ALLOW FOR DRAINAGE OF INCIDENTAL MOISTURE. CC2.0 IMPERVIA INTERIOR COVER. TM : THERMAL AND MOISTURE PROTECTION TM0.2 TM0.0 TM0.02 TM0.0 PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY /2" ON THE UNIT, OVER THE, AND ONTO WEATHER RESISTIVE BARRIER. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY OVER ROUGH OPENING SILL EXTENDING 6" UP EACH JAMB AND OVERLAP TO EXTERIOR AS PER DETAIL. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY FROM /2" ON UNIT, OVER, AND ONTO WALL SURFACE., CUT TO OVERALL WIDTH OF WINDOW COMBINATION. APPLY AT EACH END OF COMBINATION HEAD AND ACROSS COMBINATION AT THE JOINT WHERE HEAD FIN AND FRAME CONNECT. INSTALL IMMEDIATELY AFTER APPLYING TO HOLD IN PLACE WHILE SETS UP. APPLY A PIECE OF AT EACH END OVERLAPPING AND NAILING FIN. IF THERE ARE NO INSTALLATION HOLES IN THE, DRILL /2" CLEARANCE HOLES /2" FROM TOP EDGE, " FROM EACH END AND 6" ON CENTER. INSTALLATION CLIP. CUT AND BEND AS REQUIRED. SPACE 6" FROM EACH EDGE AND 6" ON CENTER. ANCHOR (2 PER CLIP) TO WALL CONSTRUCTION. ANCHOR THROUGH EACH PRE-PUNCHED HOLE AS FOLLOWS (BASED ON MATERIAL FIN WILL BE ATTACHED TO): WOOD: 2" GALVANIZED ROOFING NAILS OR #0 x 2" CORROSION RESISTANT PAN HEAD SCREW. STEEL: #0 x 2" SELF-DRILLING SCREWS. VERIFY FASTENER MATERIAL IS COMPATIBLE WITH ADJACENT STRUCTURE. STAINLESS STEEL FASTENERS ARE RECOMMENDED FOR USE WITH ACQ TREATED LUMBER. LEVEL OPENING SILL PRIOR TO UNIT INSTALLATION. PROVIDE IMPERVIOUS /2" FROM EACH OPENING JAMB AND AT WINDOW AS REQUIRED. FOR VINYL WINDOWS, ADD SO MAXIMUM SPACING IS 8". SHIM AND PLUMB UNITS AS PER INSTALLATION INSTRUCTIONS. (DO NOT OVER SHIM) WATER RESISTANT BACKER ROD AND. (SEE NOTE BELOW) WEATHER RESISTIVE BARRIER. WEATHER RESISTIVE BARRIER. FOLD IN AT OPENING JAMBS AND SECURE TO WALL CONSTRUCTION. WEATHER RESISTIVE BARRIER. LAP OVER WINDOW AND AT HEAD. 2-0- 2-- HEAD REF. ARCH. DWG.: 2/A62 JOINING JAMB REF. ARCH. DWG.: 6/A62, /A (SIM), 0/A (SIM) " BC0.0 TM0.02 TM0.2 ROD & AC0.02 AC.0 TM0.2 ROD & TM0.2 ROD & AC.0 METAL SILL FLASHING BY OTHERS " TM0.2 ROD & AC0.0 NOTE PELLA WINDOW AND DOOR INSTALLATION OR EQUIVALENT ASTM C920 CLASS 2, AAMA 80. AND AAMA 808. QUALIFIED BC0.09 TM0.0 2 JAMB REF. ARCH. DWG.: /A62 JOINING 8 SILL REF. ARCH. DWG.: /A62 " BC0.0 TM0.2 ROD & TM0.0 TM0.2 ROD & AC.0 AC0.0 TM0.0 NOTE: DUE TO INSTALLATION SEQUENCING, THE STEEL LINTEL AND FLASHING IN THIS DETAIL MUST BE INSTALLED PRIOR TO THE WINDOW INSTALLATION. THE TOP OF THE WINDOW FRAME IS NOT TO BE LEFT EXPOSED. TM0.2 ROD & AC.0 INSTALLATION CLIP TM0.2 ROD & AC0. AC.0 TM0.2 ROD & TM0.2 ROD & SILL REF. ARCH. DWG.: /A62 6 HEAD REF. ARCH. DWG.: /A62 9 HEAD REF. ARCH. DWG.: 8/A62 09 OF2
TM0.02 AC0.02 AC.0 TM0.2 ROD & " TM0.2 ROD & BC0.09 SEE ELEVATION AC0.06 CC0.0 COVER BC0.0 WOOD BLOCKING TM0.2 ROD & AC8.0 Note PROVIDE FLASHING @ HEAD OF. AC0.0 BC0.09 SHIM TM0.2 ROD & TM0.02 AC0.02 AC.0 TM0.2 ROD & " TM0.2 ROD & BC0.09 DETAIL KEYNOTES AC : ATTACHMENT COMPONENTS AC0.0 AC0.0 AC0.02 AC0.0 AC0.06 AC0. AC0.0 AC.0 AC8.0 BC : BUILDING COMPONENTS (BY OTHERS) BC0.0 BC0.0 BC0.08 BC0.09. ANCHOR THROUGH EACH PRE-PUNCHED HOLE AS FOLLOWS (BASED ON SUBSTRATE): WOOD: 2" GALVANIZED ROOFING NAILS OR #8 x /8" ZINC K-LATH SHEET METAL SCREW. TREATED WOOD: #8 x /8" STAINLESS STEEL K-LATH SHEET METAL SCREW. STEEL STUD: #8 x /" ZINC SELF-DRILLING K-LATH MODIFIED TRUSS SCREW. STEEL: #0 x 2" SELF-DRILLING SCREWS. VERIFY FASTENER MATERIAL IS COMPATIBLE WITH ALUMINUM FIN AND ADJACENT STRUCTURE. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR #80H (OR EQUAL). APPLY OVER STRUCTURE EXTENDING 6" ONTO ADJACENT STRUCTURE. PROVIDE WATERSHED OVERLAPS AT ENDS. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY /2" ON THE UNIT, OVER THE, AND ONTO WEATHER RESISTIVE BARRIER. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY OVER ROUGH OPENING SILL EXTENDING 6" UP EACH JAMB AND OVERLAP TO EXTERIOR AS PER DETAIL. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY /2" ONTO THE FRAME, OVER, ONTO BLOCKING, OVER ADJACENT UNIT, AND /2" ONTO ADJACENT UNIT FRAME. OVER LAP ADDITIONAL PIECES OF FLASHING TAPE AS NEEDED TO COVER. PROVIDE WATERSHED OVERLAPS AT ENDS. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY FROM /2" ON UNIT, OVER, AND ONTO WALL SURFACE., CUT TO OVERALL WIDTH OF WINDOW COMBINATION. APPLY AT EACH END OF COMBINATION HEAD AND ACROSS COMBINATION AT THE JOINT WHERE HEAD FIN AND FRAME CONNECT. INSTALL IMMEDIATELY AFTER APPLYING TO HOLD IN PLACE WHILE SETS UP. APPLY A PIECE OF AT EACH END OVERLAPPING AND NAILING FIN. IF THERE ARE NO INSTALLATION HOLES IN THE, DRILL /2" CLEARANCE HOLES /2" FROM TOP EDGE, " FROM EACH END AND 6" ON CENTER.. ANCHOR THROUGH EACH PRE-PUNCHED HOLE AS FOLLOWS (BASED ON MATERIAL FIN WILL BE ATTACHED TO): WOOD: 2" GALVANIZED ROOFING NAILS OR #0 x 2" CORROSION RESISTANT PAN HEAD SCREW. STEEL: #0 x 2" SELF-DRILLING SCREWS. VERIFY FASTENER MATERIAL IS COMPATIBLE WITH ADJACENT STRUCTURE. STAINLESS STEEL FASTENERS ARE RECOMMENDED FOR USE WITH ACQ TREATED LUMBER.. ANCHOR THROUGH EACH PRE-PUNCHED HOLE AS FOLLOWS (BASED ON MATERIAL FIN WILL BE ATTACHED TO): WOOD: 2" GALVANIZED ROOFING NAILS OR #0 x 2" CORROSION RESISTANT PAN HEAD SCREW. STEEL: #0 x 2" SELF-DRILLING SCREWS. VERIFY FASTENER MATERIAL IS COMPATIBLE WITH ADJACENT STRUCTURE. STAINLESS STEEL FASTENERS ARE RECOMMENDED FOR USE WITH ACQ TREATED LUMBER. DP 0: INSERT #8 x 2" PAN HEAD STAINLESS STEEL WOOD SCREWS WITH FLAT WASHER INTO EVERY PRE-PUNCHED HOLE IN THE NAILING FIN. DRIVE SCREWS UNTIL THE HEAD/WASHER CONTACTS THE FIN, HOWEVER DO NOT SINK THE WASHER. WOOD BLOCKING. HOLD FLUSH AT WINDOW FRAME. ANCHOR TO. LEVEL OPENING SILL PRIOR TO UNIT INSTALLATION. PROVIDE IMPERVIOUS /2" FROM EACH OPENING JAMB AND AT WINDOW AS REQUIRED. FOR VINYL WINDOWS, ADD SO MAXIMUM SPACING IS 8". SHIM AND PLUMB UNITS AT HINGE LOCATIONS AND AS REQUIRED TO KEEP JAMBS STRAIGHT. (DO NOT OVER SHIM) SHIM AND PLUMB UNITS AS PER INSTALLATION INSTRUCTIONS. (DO NOT OVER SHIM) 2-0- 2-- 0 JAMB REF. ARCH. DWG.: 9/A62 VERTICAL 6 JAMB REF. ARCH. DWG.: /A CC : COVERS CC0.0 ALUMINUM COVER. SEE TYPICAL DETAIL T. SEAL TO WALL CONSTRUCTION AT HEAD AND JAMBS. DO NOT SEAL VERTICAL COVERS AT SILL TO ALLOW FOR DRAINAGE OF INCIDENTAL MOISTURE. FC : FASTENING COMPONENTS " FC0.02 PRE-DRILL AND ANCHOR DOOR TO WALL CONSTRUCTION WITH ONE SCREW PER HINGE LEAF. TM : THERMAL AND MOISTURE PROTECTION BC0.0 TM0.2 ROD & TM0.0 TM0.2 TM0.0 TM0.02 TM0.0 WATER RESISTANT BACKER ROD AND. WATER RESISTANT BACKER ROD AND. (SEE NOTE BELOW) WEATHER RESISTIVE BARRIER. WEATHER RESISTIVE BARRIER. FOLD IN AT OPENING JAMBS AND SECURE TO WALL CONSTRUCTION. WEATHER RESISTIVE BARRIER. LAP OVER WINDOW AND AT HEAD. AC0. AC.0 TM0.0 TM0.2 ROD & AC.0 AC0.0 NOTE TM0.0 TM0.2 ROD & AC0.0 PELLA WINDOW AND DOOR INSTALLATION OR EQUIVALENT ASTM C920 CLASS 2, AAMA 80. AND AAMA 808. QUALIFIED REQUIRED OVER SPREAD S TM0.2 ROD & SILL REF. ARCH. DWG.: /A62 HEAD REF. ARCH. DWG.: 2/A62 Note PROVIDE FLASHING @ HEAD OF. SEE ELEVATION AC0.06 CC0.0 COVER BC0.0 WOOD BLOCKING TM0.0 ROD & AC0.0 BC0.09 AC0.0 TM0.0 ROD & BRAKE METAL BY OTHERS TM0.0 AC0. AC.0 TM0.2 ROD & AC.0 AC0.0 TM0.2 ROD & " BC0.0 TM0.2 ROD & BC0.08 SHIM FC0.02 SCREW TM0.2 ROD & TM0.0 2 VERTICAL HEAD REF. ARCH. DWG.: 2/A0 SILL REF. ARCH. DWG.: 2/A62 0 OF2
TM0.0 AC0. AC0.0 AC0.0 REQUIRED OVER SPREAD S AC0.08 TM0.29 TM0.6 BRAKE METAL BY OTHERS Door Sill Notes ARCHITECT / CONTRACTOR TO REVIEW INTERIOR FINISHED FLOOR THICKNESS & DETERMINE DOOR SILL SETTING HEIGHT REQUIREMENT. ARCHITECT / CONTRACTOR TO VERIFY FLOOR CONSTRUCTION PROVIDES SUPPORT FOR TOTAL DEPTH OF DOOR THRESHOLD. LEVEL FLOOR SURFACE PRIOR TO UNIT INSTALLATION. CLEAN AND SEAL CONCRETE IN PREPARATION FOR APPLICATION UNDER DOOR SILL. FC0.28 SCREWS TM0. TM0.6 SEE ELEVATION AC0.06 CC06.0 COVER BC0.0 WOOD BLOCKING FE0.02 FRAME EXPANDER TM0.2 ROD & AC8.0 Note PROVIDE FLASHING @ HEAD OF. AC0.0 BC0.09 SHIM TM0.2 ROD & DETAIL KEYNOTES AC : ATTACHMENT COMPONENTS AC0.0 AC0.0 AC0.02 AC0.06 AC0.08 AC0. AC0.0 AC8.0 BC : BUILDING COMPONENTS (BY OTHERS) BC0.0 BC0.08 BC0.09. ANCHOR THROUGH EACH PRE-PUNCHED HOLE AS FOLLOWS (BASED ON SUBSTRATE): WOOD: 2" GALVANIZED ROOFING NAILS OR #8 x /8" ZINC K-LATH SHEET METAL SCREW. TREATED WOOD: #8 x /8" STAINLESS STEEL K-LATH SHEET METAL SCREW. STEEL STUD: #8 x /" ZINC SELF-DRILLING K-LATH MODIFIED TRUSS SCREW. STEEL: #0 x 2" SELF-DRILLING SCREWS. VERIFY FASTENER MATERIAL IS COMPATIBLE WITH ALUMINUM FIN AND ADJACENT STRUCTURE. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR #80H (OR EQUAL). APPLY OVER STRUCTURE EXTENDING 6" ONTO ADJACENT STRUCTURE. PROVIDE WATERSHED OVERLAPS AT ENDS. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY /2" ON THE UNIT, OVER THE, AND ONTO WEATHER RESISTIVE BARRIER. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY /2" ONTO THE FRAME, OVER, ONTO BLOCKING, OVER ADJACENT UNIT, AND /2" ONTO ADJACENT UNIT FRAME. OVER LAP ADDITIONAL PIECES OF FLASHING TAPE AS NEEDED TO COVER. PROVIDE WATERSHED OVERLAPS AT ENDS. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). CLEAN FLOOR AREA AND APPLY OVER ROUGH OPENING FLOOR SURFACE EXTENDING 6" UP EACH JAMB AND OVERLAP TO EXTERIOR AS PER DETAIL. PELLA SMARTFLASH FOIL BACKED, BUTYL WINDOW AND DOOR (OR EQUAL). APPLY FROM /2" ON UNIT, OVER, AND ONTO WALL SURFACE., CUT TO OVERALL WIDTH OF WINDOW COMBINATION. APPLY AT EACH END OF COMBINATION HEAD AND ACROSS COMBINATION AT THE JOINT WHERE HEAD FIN AND FRAME CONNECT. INSTALL IMMEDIATELY AFTER APPLYING TO HOLD IN PLACE WHILE SETS UP. APPLY A PIECE OF AT EACH END OVERLAPPING AND NAILING FIN. IF THERE ARE NO INSTALLATION HOLES IN THE, DRILL /2" CLEARANCE HOLES /2" FROM TOP EDGE, " FROM EACH END AND 6" ON CENTER.. ANCHOR THROUGH EACH PRE-PUNCHED HOLE AS FOLLOWS (BASED ON MATERIAL FIN WILL BE ATTACHED TO): WOOD: 2" GALVANIZED ROOFING NAILS OR #0 x 2" CORROSION RESISTANT PAN HEAD SCREW. STEEL: #0 x 2" SELF-DRILLING SCREWS. VERIFY FASTENER MATERIAL IS COMPATIBLE WITH ADJACENT STRUCTURE. STAINLESS STEEL FASTENERS ARE RECOMMENDED FOR USE WITH ACQ TREATED LUMBER. DP 0: INSERT #8 x 2" PAN HEAD STAINLESS STEEL WOOD SCREWS WITH FLAT WASHER INTO EVERY PRE-PUNCHED HOLE IN THE NAILING FIN. DRIVE SCREWS UNTIL THE HEAD/WASHER CONTACTS THE FIN, HOWEVER DO NOT SINK THE WASHER. WOOD BLOCKING. HOLD FLUSH AT WINDOW FRAME. ANCHOR TO. SHIM AND PLUMB UNITS AT HINGE LOCATIONS AND AS REQUIRED TO KEEP JAMBS STRAIGHT. (DO NOT OVER SHIM) SHIM AND PLUMB UNITS AS PER INSTALLATION INSTRUCTIONS. (DO NOT OVER SHIM) 2-- 8 HEAD REF. ARCH. DWG.: /A62 TM0.0 ROD & 2 2 SILL REF. ARCH. DWG.: /A602, 2/A602 (SIM), /A602 (SIM) 2 VERTICAL CC : COVERS CC0.0 CC06.0 FC : FASTENING COMPONENTS FC0.02 FC0.08 ALUMINUM COVER. SEE TYPICAL DETAIL T. SEAL TO WALL CONSTRUCTION AT HEAD AND JAMBS. DO NOT SEAL VERTICAL COVERS AT SILL TO ALLOW FOR DRAINAGE OF INCIDENTAL MOISTURE. EXPANSION COVER WITH BULB GASKET. PRE-DRILL AND ANCHOR DOOR TO WALL CONSTRUCTION WITH ONE SCREW PER HINGE LEAF. PRE-DRILL PILOT HOLES AND ANCHOR UNITS TOGETHER WITH WOOD SCREWS 6" FROM ENDS AND 6" ON CENTER (MAXIMUM). 2-0- FC0.28 REMOVE EXISTING SCREWS THAT ATTACH THE OAK THRESHOLD TO THE DOOR FRAME SILL. RE-DRILL THROUGH THE EXISTING HOLES THROUGH THE FRAME SILL. COUNTER SINK THE OAK THRESHOLD. INSERT #8 X " CORROSION RESISTANT FLAT HEAD DECK SCREW ANCHORING TO WOOD FLOOR CONSTRUCTION. (IF CONCRETE FLOOR USE: /6" X -/" CORROSION RESISTANT FLAT HEAD MASONRY FASTENER). FE : FRAME EXPANDERS / RECEPTORS TM0.02 TM0.02 FE0.02 FRAME EXPANDER. TRIM AS REQUIRED. SEAL AT TOP END TO WALL CONSTRUCTION. DO NOT SEAL AT BOTTOM. SEE TYPICAL DETAIL T. AC0.02 AC0.02 JE : JAMB EXTENSIONS AND INTERIOR TRIM JE0.0 PRE-APPLIED JAMB EXTENSION. TM : THERMAL AND MOISTURE PROTECTION AC0.0 AC0.0 TM0.0 TM0. TM0.6 TM0.8 TM0.2 TM0.29 TM0.02 TM0.0 WATER RESISTANT BACKER ROD AND. CONTINUOUS. TURN UP AT JAMBS 6" MINIMUM CONTINUOUS. TIE IN WITH PERIMETER. CONTINUOUS. WATER RESISTANT BACKER ROD AND. (SEE NOTE BELOW) APPLY BEAD OF AT SILL. ALLOW 2" SPACE IN LINE AT CENTER OF OPENING. WEATHER RESISTIVE BARRIER. FOLD IN AT OPENING JAMBS AND SECURE TO WALL CONSTRUCTION. WEATHER RESISTIVE BARRIER. LAP OVER WINDOW AND AT HEAD. TM0.0 ROD & TM0.0 ROD & TM0.0 ROD & TM0.0 ROD & NOTE FC0.02 SCREW PELLA WINDOW AND DOOR INSTALLATION OR EQUIVALENT ASTM C920 CLASS 2, AAMA 80. AND AAMA 808. QUALIFIED BC0.08 8" 8" 9 JAMB REF. ARCH. DWG.: 6/A62 22 JAMB REF. ARCH. DWG.: /A62 TM0.02 FC0.08 SCREWS AC0.02 TM0.8 JE0.0 JAMB EXTENSION AC0.0 TM0.0 ROD & TM0.0 ROD & FC0.02 SCREW CC0.0 COVER TM0.6 BC0.08 8" 20 JAMB REF. ARCH. DWG.: 6/A62 2 JOINING OF2