EQD075 Series (Eighth-Brick)DC-DC Converter Power Modules 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W

Similar documents
Naos Raptor 6A: Non-Isolated DC-DC Power Modules 4.5Vdc 14Vdc input; 0.59Vdc to 6Vdc Output; 6A Output Current

NQR010A0X4: Non-Isolated DC-DC Power Modules 4.5Vdc 14Vdc input; 0.59Vdc to 6Vdc Output;10A Output Current

Naos Raptor 10A: Non-Isolated DC-DC Power Modules 4.5Vdc 14Vdc input; 0.59Vdc to 6Vdc Output;10A Output Current

NaOS TM NXA025 SIP Non-isolated Power Modules: 10Vdc 14Vdc Input; 0.8Vdc to 5.5Vdc Output; 25A Output Current

Naos Raptor 60A: Non-Isolated Power Modules Vdc input; 0.6Vdc to 5.0Vdc Output; 60A Output Current

Naos Raptor 20A: Non-Isolated Power Modules Vdc input; 0.59Vdc to 6Vdc Output; 20A Output Current

Naos Raptor 40A Non-Isolated Power Modules Vdc input; 0.6Vdc to 5.0Vdc Output; 40A Output Current

Austin Microlynx TM 12V SIP Non-isolated Power Modules: 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A Output Current

RoHS Compliant. Data Sheet. Features. Applications. Description. April 19, Compliant to RoHS EU Directive 2002/95/EC (- Z versions)

Austin Minilynx TM 12V SIP Non-isolated Power Modules: Vdc Input; 0.75Vdc to 5.5 Vdc Output; 3A Output Current

Naos Raptor 6A: Non-Isolated DC-DC Power Modules

QBW025A0B Series Power Modules; DC-DC Converters Vdc Input; 12Vdc Output; 25 A

24 Austin Lynx TM : Non-Isolated DC-DC Power Modules 20Vdc 30Vdc input; 5.0 Vdc to 15 Vdc output; 70W Output Power

QPW025A0F41/QPW025A0F41-H DC-DC Power Module 36-75Vdc Input; 3.3Vdc Output Voltage; 25A Output Current

n Compatible with RoHS EU Directive /EC n Compatible in Pb- free or SnPb reflow environment n Nonisolated output n High efficiency: 86% typical

12V Austin Lynx TM : SIP Non-Isolated DC-DC Power Modules, Programmable 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current

12V Austin MiniLynx TM : SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 3A Output Current

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Austin MicroLynx TM : SIP Non-Isolated DC-DC Power Modules 3Vdc 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 5A Output Current

EQW006 Series, Eighth-Brick Power Modules: DC-DC Converter 36 75Vdc Input; 12Vdc Output; 6A Output Current

Austin Lynx TM : SIP Non-Isolated DC-DC Power Modules, Programmable 3.0Vdc 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 10A Output Current

SE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W

QPW050/060 Series Power Modules; DC-DC converters 36-75Vdc Input; 1.2Vdc to 3.3Vdc Output

12V Austin SuperLynx TM 16A: SIP Non-Isolated DC-DC Power Module 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current

12V Austin SuperLynx TM II: SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current

12V Austin Lynx TM II: SIP Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current

n Compatible with RoHS EU Directive 2002/95/EC (-Z Versions) n High efficiency: 92.5% typical n Industry standard pinout n Isolation voltage:2250 Vdc

NQR002A. Data Sheet. Features. Application. Description. Compatible in. 0.6Vdc to 5.5Vdc, via external resistor Tunable Loop response.

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

GE Energy. 6A Austin MicroLynx II TM : 12V SIP Non-Isolated DC-DC Power Module. Data Sheet. RoHS Compliant

Austin Microlynx TM 12V SMT Non-isolated Power Modules: 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A Output Current

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

BARRACUDA SERIES Features

QRW025 Series Power Modules; dc-dc Converters 36 Vdc - 75 Vdc Input, 1.2 to 3.3 Vdc Output; 25A. RoHS Compliant. Data Sheet April 7, 2006.

V36SE12005 FEATURES. Delphi Series V36SE, 1/16 th. Brick DC/DC Power Modules: 18~75Vin, up to 60W OPTIONS APPLICATIONS

HC006/010 Series Power Modules; dc-dc Converters 18-36Vdc Input; 3.3Vdc & 5Vdc Outputs; 6.6A to 10A Current

APTS/APXS003A0X: Non-Isolated DC-DC Power Modules: 4.5Vdc 14Vdc input; 0.59Vdc to 5.5Vdc output; 3A Output Current

(DOSA) VDC, 5.5 A.

Delphi Series H48SC3R325, 85W Half Brick Family DC/DC Power Modules: 48V in, 3.3V/25A out

GE Energy. 6A Austin MicroLynx II TM : SIP Non-Isolated DC-DC Power Module. Data Sheet. RoHS Compliant EZ-SEQUENCE TM

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 12V/10A out

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, 3.3Vo, 50W

9-36V ProLynx TM : Non-Isolated DC-DC Power Modules 9Vdc 36Vdc input; 3Vdc to 18Vdc output; 3A to 1.5A Output Current

TBD. Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W FEATURES OPTIONS APPLICATIONS

S24SP series 60W Single Output DC/DC Converter

V36SE12004 FEATURES. Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W OPTIONS APPLICATIONS

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

Cool Power Technologies

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 5V/20A out

JRCW450U Orca* Series; DC-DC Converter Power Modules Vdc Input; 48Vdc Output; 450W Output

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

Austin SuperLynx TM II 12V SMT Non-isolated Power Modules: 8.3Vdc 14Vdc Input; 0.75Vdc to 5.5Vdc Output; 16A Output Current

Austin MiniLynx TM : SMT Non-Isolated DC-DC Power Modules 2.4Vdc 5.5Vdc input; 0.75Vdc to 3.63Vdc output; 3A Output Current

Delphi Series S48SP, 35W 1x1 Brick DC/DC Power Modules: 48V in, 5V/7A out

24V Austin Lynx TM : Non-Isolated DC-DC Power Modules 18/20Vdc 30/32Vdc input; 3 to 6Vdc & 5 to 15Vdc output; 30/50W Output Features

Delphi Series V48SR, 1/16 th Brick 66W

Delphi Series S36SA, 25W Family DC/DC Power Modules: 18Vin to 60Vin, 3.3V/8A out

S24SE/S24DE series 15W Single/Dual Output DC/DC Converter

Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 15V/4A out

Delphi Series H48SA, 450W Half Brick Family

ERCW003A6R Power Modules; DC-DC Converters 36 75Vdc Input; 28Vdc Output; 3.6Adc Output ORCA SERIES Features RoHS Compliant Applications Options

Q54SJ W DC/DC Power Modules FEATURES. Q54SJ12058, 700W Quarter Brick DC/DC Power Modules: 40~60Vin, 12.2V/ 57.4A out OPTIONS APPLICATIONS

` FEATURES. Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.0V/50A out OPTIONS APPLICATIONS

12V Austin MiniLynx TM : SMT Non-Isolated DC-DC Power Modules 8.3Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 3A Output Current

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.8V/40A out

RoHS Compliant. Data Sheet September 10, Features. Applications. Description. Compliant to RoHS EU Directive 2002/95/EC (-Z versions)

Delphi Series H48SA, 150W Half Brick Family DC/DC Power Modules: 36~75V in, 48V/3.2A out

Delphi Series Q48SK, Quarter Brick Family DC/DC Power Modules: 36~75V in, 12V/18A out, 216W

OVP 2:1. Wide Range. Protection

Delphi Series E48SP Eighth Brick Family DC/DC Power Modules: 48V in, 12V/20A out

Delphi S36SE, 25W 1x1 Brick Series DC/DC Power Modules: 36~75V in, 12V/2A out

Austin MicroLynx TM 5A: Non-Isolated DC-DC Power Module 3.0Vdc 5.8Vdc input; 0.75Vdc to 4.0Vdc output; 5A Output Current

12V Austin MicroLynx TM 5A: Non-Isolated DC-DC Power Module 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc Output; 5A Output Current

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

JRCW016A0R Orca * Series; DC-DC Converter Power Modules Vdc Input; 28Vdc Output; 16Adc Output

Delphi Series Q36SR, Quarter Brick 204W DC/DC Power Modules: 18V~75Vin,12V, 17Aout

6. SAFETY 6.1 Input Fusing and Safety Considerations.

Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W

MIW3000 Series EMI. 5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Delphi Series T48SR, 1/32 Brick Family DC/DC Power Modules: 36~75V in, 5V/5A out, 25W FEATURES OPTIONS APPLICATIONS

AA SERIES (1 x 1 Package) Up to 30 Watt DC-DC Converter

SMT20C SERIES. Single Output TÜV. SMT20C Series 20 A DC-DC Converter C Class Non-Isolated

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

12V Mega TLynx TM : Non-Isolated DC-DC Power Modules: 6.0Vdc 14Vdc input; 0.8 to 3.63Vdc Output; 30A Output Current

SIL20C SERIES. Single Output. SIL20C Series 20 A DC-DC Converter C Class Non-Isolated

30A Austin MegaLynx TM : Non-Isolated DC-DC Power Modules 2.7Vdc 4.0Vdc input; 0.8Vdc to 2.0Vdc output; 30A Output Current

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

12V Pico TLynx TM 2A: Non-Isolated DC-DC Power Modules 3Vdc 14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current

SHHD003A0A Hammerhead* Series; DC-DC Converter Power Modules 18-75Vdc Input; 5.0Vdc, 3A, 15W Output

12V Austin SuperLynx TM 16A: Non-Isolated DC-DC Power Module 10Vdc 14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out

QSTS015A0S10R0 BARRACUDA* Series; DC-DC Converter Power Modules 45Vdc 65Vdc input; 10Vdc output; 15A Output Current

AA SERIES (1 x 1 Package) Up to 10 Watt DC-DC Converter

Delphi DNT04, Non-Isolated Point of Load

0RCY-F0S10x Isolated DC-DC Convert

H36SA W DC/DC Power Module

Cool Power Technologies

Encapsulated Type. Page I-III. Page 1-15 Open-Frame Type. S36SE3R305 Datasheet

Transcription:

EQD075 Series (Eighth-Brick)DC-DC Converter Power Modules 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W RoHS Compliant Features Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to RoHS EU Directive 2002/95/EC with lead solder exemption (non-z versions) Applications Distributed power architectures Wireless Networks Optical and Access Network Equipment Enterprise Networks Options Positive logic, Remote On/Off Auto restart after fault protection shutdown Pin length Description High efficiency 92% at 5.0V o, full load, 24V in Industry standard Eighth brick footprint and pin out 57.9 mm x 22.8 mm x 8.5 mm (2.28 in. x 0.90 in. x 0.335 in.) 3:1 Input voltage range: 18-60 Vdc Input under/overvoltage protection Output overcurrent/voltage protection Over-temperature protection Tightly regulated output Remote sense No reverse current during output shutdown Negative logic, Remote On/Off Output voltage programmable from 3.0 Vdc to 5.5Vdc Input-to-output isolation (Basic Insulation: 1500V) Wide operating temperature range (-40 C to 85 C) Meets conducted emissions requirements of FCC/EN55022 Class A without external filter Within FCC and VDE Class A Radiated Limits UL* 60950-1Recognized, CSA C22.2 No. 60950-1- 03 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed Meets the voltage and current requirements for ETSI 300-132-2 and complies with and licensed for Basic insulation rating per EN60950-1 ISO** 9001 and ISO 14001 certified manufacturing facilities The EQD075 series DC-DC converters are a new generation of open-frame DC/DC power modules designed to support a 3:1 input voltage range, that allows operation in both 24V or 48V nominal input voltage systems, thus eliminating the need for separate power modules for each input voltage range. These single output DC-DC converters operate over an input voltage range of 18 to 60 Vdc. The series is also designed to provide a wide output voltage set/trim range of 3.0 to 5.5Vdc, with output current up to 20A at 3.3Vdc or 15A at 5.0Vdc in an industry standard eighth brick package. The output is isolated from the input, allowing versatile polarity configurations and grounding connections. Built in filtering for both input and output minimizes the need for external filtering. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.v. ** ISO is a registered trademark of the International Organization of Standards Document No: DS05-031 ver. 1.31 PDF name: EQD075A.pdf

Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous A V IN -0.3 60 Vdc Transient (100 ms) V IN, trans -0.3 75 Vdc Operating Ambient Temperature A T A -40 85 C (see Thermal Considerations section) Storage Temperature A T stg -55 125 C I/O Isolation (100% factory Hi-Pot tested) Input - Output A 1500 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage A V IN 18 24/48 60 Vdc Maximum Input Current (V IN=0 to V IN, max, V o = V o,set, I O=I O, max ) A I IN,max 6 Adc Input Stand-by Current Module on / off disabled (V IN = V IN, nom, V o = 0 V) A I IN, Stby 25 ma Input No Load Current Module on / off enabled (V IN = V IN, nom, I o = 0 A) A I IN, NL 110 ma Inrush Transient A I 2 t 1 A 2 s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12μH source impedance; T a 25 o C, C in = 33μF) A 30 map-p Input Ripple Rejection (100-120Hz) A 50 db CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a very fast acting surface mount fuse with a maximum rating of 6.3 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer s data sheet for further information. LINEAGE POWER 2

Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit Output Voltage Set-point A V O, set -1.6 +1.6 % V O, set (V IN = V IN, min=24/48, I O =I O, max, T A =25 C) Output Voltage A V O -3 - +3 % V O (Over all line, load, and Temp Conditions Until end of life) Output Regulation Line (V IN = V IN, min to V IN, max) A 0.05 0.2 % V O, nom Load (I O = I O, min to I O, max) A 0.05 0.2 % V O, nom Temperature (T ref =T A, min to T A, max) A 0.25 1 % V O, nom Output Ripple and Noise on nominal output (V IN =V IN, nom and I O = I O, min to I O, max, C out = 1μF ceramic // 10μF Tantalum capacitor) 3.3 to 5.0V output RMS (5Hz to 20MHz bandwidth) A 5 20 mv rms Peak-to-Peak (5Hz to 20MHz bandwidth) A 50 80 mv pk-pk External Capacitance ESR 10 mω A C O 0 5000 μf Output Current @ V o = 3.3V A I o 0 20 A dc @ V o = 5V A I o 0 15 A dc Output Current Limit Inception (Hiccup Mode) (V o = 95% V o, set ) A I O, lim 105 115 150 % I o, max Output Short-Circuit Current A I O, s/c 150 % I o, max V O 250 mv @ 25 o C Efficiency V IN= 24V, T A=25 C, I O= I O, max A @ V o = 3.3V, I O = 20A A η 87 % @ V o = 5V, I O = 15A A η 92 % V IN= 48V, T A=25 C, I O= I O, max A @ V o = 3.3V, I O = 20A A η 88 % @ V o = 5V, I O = 15A A η 90 % Switching Frequency A f sw 160 KHz LINEAGE POWER 3

Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit Dynamic Load Response (di o/dt= 1A / 10 s; V IN = V IN, nom; T A=25 C) Load Change from I o= 50% to 75% of I o,max Peak Deviation A V pk 2 4 %V o Settling Time (V o<10% peak deviation) t s 80 150 s Load Change from I o= 50% to 25% of I o,max Peak Deviation A V pk 2 4 %V o Settling Time (V o<10% peak deviation) t s 80 150 s Isolation Specifications Parameter Min Typ Max Unit Isolation Capacitance 1000 pf Isolation Resistance 10 M General Specifications Parameter Min Typ Max Unit Calculated MTBF (V IN = 24V, I O=80%I O, max, T A=40 C) 1,677,152 Hours Weight 25.3 (0.89) g (oz.) LINEAGE POWER 4

Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit On/Off Signal interface (V IN=V IN, min to V IN, max ; Open collector or equivalent, Signal referenced to V IN (-) terminal Logic Low (Module OFF) Logic High (Module ON) Turn-On Delay and Rise Times (I O=80 % I O, max, T A = 25 o C) Input low Voltage = 0.0 V A VIL -0.7 1.2 V Input low Current = 1 ma A IIL 1.0 ma Input High Voltage = 5.0 V A VIH 5 V Input High Current = 0 ma A IIH 50 μa Case 1: On/Off input is set to Logic High and then input power is applied (delay from instant at which V IN = V IN, min until V o =10% of V o,nom) Case 2: Input power is applied for at least one second and then the On/Off input is set to logic high (delay from instant at which Von/Off = 0.9V until V o=10% of V o, set) A T delay 15 20 msec A T delay 5 10 msec Output voltage Rise time (time for Vo to rise from 10% of V o, nom to 90% of V o, nom) V o, nom set to 3.3V Output voltage Rise time (time for Vo to rise from 10% of V o, nom to 90% of V o, nom) V o, nom set to 5.0V Output voltage overshoot Startup I O= 80% of I O, max; T A = 25 o C A T rise 10 15 msec A T rise 15 20 msec 1 % V O, set Input Undervoltage Lockout A V UVLO Turn-on Threshold 17 18 V Turn-off Threshold 14 15.5 V Hysteresis 1.5 Input Over voltage Lockout A V OVLO Turn-on Threshold 60 62 V Turn-off Threshold 64 65 V Hysteresis 2 Output Voltage Set point Adjustment Output remote sense voltage range A V SENSE 10 % V O,nom (Max voltage drop is 0.5 V) Output voltage adjustment range (TRIM) A 3.0 5.5 Vdc Over voltage protection A V OV, set 5.7 6.5 Vdc Over Temperature Protection A T ref 130 C LINEAGE POWER 5

Characteristic Curves The following figures provide typical characteristics for EQD075A at T A = 25 O C INPUT CURRENT, IIN (A) 6 5 4 3 2 1 Io = 20A Io = 10A Io = 0.05A 0 15 25 35 45 55 65 INPUT VOLTAGE, V IN (V) Figure 1. Typical Input characteristics at room temperature (V o = 3.3V). ON/OFF VOLTAGE OUTPUT VOLTAGE VOn/off (V) (2V/div) VO (V) (1V/div) TIME, t (2 ms/div) Figure 4. Typical Start-Up Characteristics from Remote ON/OFF (V o = 3.3V, I o = 20A, V in = 48V). EFFICIENCY, (%) 95 90 85 80 75 Vin = 18V Vin = 48V Vin = 24V Vin = 60V 70 0 5 10 15 20 OUTPUT CURRENT, I O (A) Figure 2. Typical Converter Efficiency versus Output Current at room temperature (V o = 3.3V). OUTPUT VOLTAGE VO (V) (50mV/div) TIME, t (1 s/div) Figure 3. Typical Output Ripple and Noise at V o = 3.3V and I o = 20A. OUTPUT CURRENT OUTPUT VOLTAGE IO (A) (5A/div) VO (V) (200 mv/div) TIME, t (0.2 ms/div) Figure 5. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (3.3V@20A) at V in =48V. OUTPUT CURRENT OUTPUT VOLTAGE IO (A) (5A/div) VO (V) (200 mv/div) TIME, t (0.2 ms/div) Figure 6. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (3.3V@20A) at V in = 24V. LINEAGE POWER 6

Characteristic Curves (continued) The following figures provide typical characteristics for EQD075A at T A = 25 O C INPUT CURRENT, IIN (A) 6 5 4 3 2 1 Io = 15A Io = 7.5A Io = 0A 0 15 25 35 45 55 65 INPUT VOLTAGE, V IN (V) Figure7. Typical Input characteristics at room temperature (V o = 5V). ON/OFF VOLTAGE OUTPUT VOLTAGE VOn/off (V) (5V/div) VO (V) (2V/div) TIME, t (5 ms/div) Figure 10. Typical Start-Up Characteristics from Remote ON/OFF (V o = 5V, I o = 15A, V in = 48V) EFFICIENCY, (%) 95 90 85 80 75 Vin = 18V Vin = 24V Vin = 48V Vin = 60V 70 0 5 10 15 OUTPUT CURRENT, I O (A) Figure 8. Typical Converter Efficiency versus Output Current at room temperature (V o = 5V). OUTPUT CURRENT OUTPUT VOLTAGE IO (A) (5A/div) VO (V) (100 mv/div) TIME, t (0.2ms/div) Figure 11. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (5V@15A) at V in =48V. OUTPUT VOLTAGE VO (V) (50mV/div) TIME, t (1 s/div) OUTPUT CURRENT OUTPUT VOLTAGE IO (A) (5A/div) VO (V) (100 mv/div) TIME, t (0.2ms/div) Figure 9. Typical Output Ripple and Noise at V o = 5V and I o = 15A. Figure 12. Transient Response to a Dynamic Load Change from 50% to 75% to 50% of full load (5V@15A) at V in =24V. 7

Characteristic Curves (continued) The following figures provide typical characteristics for EQD075A at T A = 25 O C OUTPUT CURRENT (A) 20 15 10 5 NC 0.5 m/s (100 lfm) 1.0 m/s (200 lfm) 2.0 m/s (400 lfm) OUTPUT CURRENT (A) 25 20 15 10 5 NC 0.5 m/s (100 lfm) 1.0 m/s (200 lfm) 2.0 m/s (400 lfm) 0 0 20 30 40 50 60 70 80 90 20 30 40 50 60 70 80 90 TEMPERATURE ( O C) TEMPERATURE ( O C) Figure 13. Thermal Derating Curves for the EQD075 module at 24Vin and V o=5v. Figure 16. Thermal Derating Curves for the EQD075 module at 48Vin and V o=3.3v. 20 2.0 m/s (400 lfm) OUTPUT CURRENT (A) 15 10 5 NC 0.5 m/s (100 lfm) 1.0 m/s (200 lfm) 0 20 30 40 50 60 70 80 90 TEMPERATURE ( O C) Figure 14. Thermal Derating Curves for the EQD075 module at 48Vin and V o=5v. 25 OUTPUT CURRENT (A) 20 15 10 5 NC 0.5 m/s (100 lfm) 1.0 m/s (200 lfm) 2.0 m/s (400 lfm) 0 20 30 40 50 60 70 80 90 TEMPERATURE ( O C) Figure 15. Thermal Derating Curves for the EQD075 module at 24Vin and V o=3.3v. LINEAGE POWER 8

Test Configurations TO OSCILLOSCOPE BATTERY L TEST 12μH C S 220μF Electrolytic E.S.R.<0.1 @ 20 C 100kHz C IN 33 μf Ceramic CURRENT PROBE V IN (+) COM Design Considerations Input Filtering The power module should be connected to a low acimpedance source. Highly inductive source impedance can affect the stability of the power module. For the test configuration in Figure 17, a 220µF electrolytic capacitor (ESR<0.1Ω at 100 khz), mounted close to the power module helps ensure the stability of the unit. Consult your sales representative for further applications guidelines. NOTE: Measure input reflected ripple current with a simulated source inductance (L TEST ) of 12μH. Capacitor C S offsets possible battery impedance. Measure current as shown above. Figure 17. Input Reflected Ripple Current Test Setup. V O (+) COM COPPER STRIP 1uF. 10uF SCOPE RESISTIVE LOAD GROUND PLANE NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 18. Output Ripple and Noise Test Setup. Rdistribution Rcontact VIN(+) VO Rcontact Rdistribution Safety Considerations For safety-agency approval of the system in which the power module is used, the power module must be installed in compliance with the spacing and separation requirements of the end-use safety agency standard, i.e., UL60950-1, CSA C22.2 No. 60950-1- 03, EN60950-1 and VDE 0805:2001-12. These converters have been evaluated to the spacing requirements for Basic insulation, per the above safety standards; and 1500 Vdc is applied from V in to V out to 100% of outgoing production. For end products connected to 48V dc nominal DC MAINS (i.e. central office dc battery plant), no further fault testing is required. For all input voltages, other than DC MAINS, where the input voltage is less than 60V dc, if the input meets all of the requirements for SELV, then: The output may be considered SELV. Output voltages will remain within SELV limits even with internally-generated non-selv voltages. Single component failure and fault tests were performed in the power converters. One pole of the input and one pole of the output are to be grounded, or both circuits are to be kept floating, to maintain the output voltage to ground voltage within ELV or SELV limits. VIN VO RLOAD The power module has ELV (extra-low voltage) outputs when all inputs are ELV. Rdistribution Rcontact COM COM Rcontact Rdistribution NOTE: All voltage measurements to be taken at the module terminals, as shown above. If sockets are used then Kelvin connections are required at the module terminals to avoid measurement errors due to socket contact resistance. Figure 19. Output Voltage and Efficiency Test Setup. All flammable materials used in the manufacturing of these modules are rated 94V-0, or tested to the UL60950 A.2 for reduced thickness. The input to these units is to be provided with a maximum 6.3 A very fast-acting surface mount fuse in the unearthed lead. Efficiency = V O. I O V IN. I IN x 100 % 9

Feature Descriptions Remote On/Off The EQD075 series power modules have primary referenced remote On/Off. The remote on/off is open collector compatible with the signal common referenced to the negative input. The standard remote on/off negative logic is such that a unit operates (ON) when the remote on/off signal is low or short circuit to minus V IN. A module will be OFF when the remote on/off pin is open circuit or when the remote on/off signal is high. The optional positive logic remote on/off is such that a unit operates (ON) when the remote on/off signal is high or open-circuit. A unit will be OFF when the remote on/off signal is low or short-circuited to minus V IN. Ion/off Von/off VIN(+) ON/OFF VIN(-) VO COM Figure 20. Circuit configuration for using Remote On/Off Implementation. Overcurrent Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current-limiting circuitry and can endure current limiting continuously. At the point of current-limit inception, the unit enters a hiccup mode. If the unit is not configured with auto restart, then it will latch off following the over current condition. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. If the unit is configured with the auto-restart option (4), it will remain in the hiccup mode as long as the overcurrent condition exists; it operates normally, once the output current is brought back into its specified range. Input Undervoltage Lockout At input voltages below the input under voltage lockout limit, the module operation is disabled. The module will begin to operate at an input voltage above the under voltage lockout turn-on threshold. Overtemperature Protection These modules feature an overtemperature protection circuit to safeguard against thermal damage. The circuit shuts down and latches off the module when the maximum device reference temperature is exceeded. The module can be restarted by cycling the dc input power for at least one second or by toggling the remote on/off signal for at least one second. If the auto-restart option (4) is ordered, the module will automatically restart upon cool-down to a safe temperature. Over Voltage Protection The output over voltage protection scheme of the modules has an independent over voltage loop to prevent single point of failure. This protection feature latches in the event of over voltage across the output. Cycling the on/off pin or input voltage resets the latching protection feature. If the auto-restart option (4) is ordered, the module will automatically restart upon an internally programmed time elapsing. Remote sense The EQD075 series power modules have a Remote Sense feature to minimize the effects of distribution losses by regulating the voltage at the Remote Sense pin (See Figure 21). The voltage between the Sense pin and Vo pin must not exceed 0.5V. The opened sense line resistor value should be selected in range of 30 ohm 100 ohm that eases use of external parallel load share controller. The amount of power delivered by the module is defined as the output voltage multiplied by the output current (V o x I o). When using Remote Sense, the output voltage of the module can increase, which, if the same output is maintained, increases the power output from the module. Make sure that the maximum output power of the module remains at or below the maximum rated power. When the Remote Sense feature is not being used, connect the Remote Sense pins to the output pins of the module. SUPPLY II CONTACT RESISTANCE VI(+) VI(-) SENSE(+) SENSE( ) VO(+) VO( ) IO LOAD CONTACT AND DISTRIBUTION LOSSES Figure 21. Effective Circuit Configuration for remote sense operation. LINEAGE POWER 10

Feature Descriptions (continued) Output Voltage Programming The output voltage is adjustable between 3.0 to 5.5V (A version). A resistor placed between the Trim pin and Sense (+) increases the output voltage and a resistor placed between the Trim pin and Sense (-) decreases the output voltage. Figure 22 shows the circuit configuration using an external resistor. The trim resistor should be positioned close to the module. If the trim pin is not used then the pin shall be left open. If no trim resistor is connected, for the A version, the output voltage will be 5V. The following equations determine the required external resistor value to obtain a percentage output voltage change of Δ%. To decrease output voltage set point: 510 Rtrim down 10. 2 K % Where, Vo, nom Vdesired % 100 Vo, nom V desired = Desired output voltage set point (V). To increase the output voltage set point 5.1* Vo, nom* 100 % 510 Rtrim up 10. 2 K 1.225* % % Although the output voltage can be increased by both the remote sense and by the trim, the maximum increase for the output voltage is not the sum of both. The maximum absolute increase in output voltage, due to simultaneous remote sense and trim increases, shall not exceed the larger of the specified individual remote sense or trim maximum limits shown in the Features Specifications table. VIN(+) ON/OFF VO(+) SENSE (+) TRIM Rtrim-up LOAD shutdown an internal feature implemented in the module ensures there will be no reverse current. Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation. Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data is based on physical measurements taken in a wind tunnel. The test set-up is shown in Figure 23. Wind Tunnel PWBs The thermal reference point, T ref, used in the specifications is shown in Figure 24. For reliable operation, this temperature should not exceed 125 O C. Please refer to the Application Note Thermal Characterization Process For Open-Frame Board- Mounted Power Modules for a detailed discussion of thermal aspects including maximum device temperatures. x 6.55_ (0.258) Air flow 25.4_ (1.0) 76.2_ (3.0) Figure 23. Thermal Test Set up. Power Module Probe Location for measuring airflow and ambient temperature Rtrim-down VIN(-) SENSE (-) VO(-) Figure 22. Circuit Configuration to program output voltage using an external resistor. Pre-Bias Immunity The modules are able to start into a pre-biased output with a monotonic rise of the output voltage. During Tref Figure 24. T ref Temperature Measurement Location. 11

Mechanical Outline Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] TOP VIEW SIDE VIEW BOTTOM VIEW LINEAGE POWER 12

EQD075 series Single Output: Eighth Brick Power Modules: Recommended Pad Layout Dimensions are in millimeters and [inches]. Tolerances: x.x mm 0.5 mm [x.xx in. 0.02 in.] (Unless otherwise indicated) x.xx mm 0.25 mm [x.xxx in 0.010 in.] LINEAGE POWER 13

Through-Hole Lead-Free Soldering Information The RoHS-compliant through-hole products use the SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components. They are designed to be processed through single or dual wave soldering machines. The pins have an RoHS-compliant finish that is compatible with both Pb and Pb-free wave soldering processes. A maximum preheat rate of 3 C/s is suggested. The wave preheat process should be such that the temperature of the power module board is kept below 210 C. For Pb solder, the recommended pot temperature is 260 C, while the Pb-free solder pot is 270 C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power Power System representative for more details. Post solder Cleaning and Drying Considerations Post solder cleaning is usually the final circuit-board assembly process prior to electrical board testing. The result of inadequate cleaning and drying can affect both the reliability of a power module and the testability of the finished circuit-board assembly. For guidance on appropriate soldering, cleaning and drying procedures, refer to Lineage Power Board Mounted Power Modules: Soldering and Cleaning Application Note. LINEAGE POWER 14

EQD075 series Single Output: Eighth Brick Power Modules: Ordering Information Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Code Product codes Input Voltage Output Output Connector Efficiency Voltage Current Type Comcodes EQD075A1 18 60V 5/3.3V 15/20A 90% TH 108994463 EQD075A41 18 60V 5/3.3V 15/20A 90% TH 108994455 EQD075A41Z 18 60V 5/3.3V 15/20A 90% TH CC109114393 EQD075A641 18 60V 5/3.3V 15/20A 90% TH CC109126117 EQD075A641Z 18 60V 5/3.3V 15/20A 90% TH CC109147880 EQD075A81Z 18 60V 5/3.3V 15/20A 90% TH CC109129103 Table 2. Device Options Option Suffix Negative remote on/off logic 1 Auto-restart (from OTP, OVP, OCP) 4 Pin Length: 3.68 mm 0.25 mm (0.145 in. 0.010 in.) 6 Pin Length: 2.79 mm 0.25 mm (0.110 in. 0.010 in.) 8 RoHS Compliant Z Asia-Pacific Headquarters Tel: +65 6593 7211 World Wide Headquarters Lineage Power Corporation 601 Shiloh Road, Plano, TX 75074, USA +1-800-526-7819 (Outside U.S.A.: +1-972-244-9428) www.lineagepower.com e-mail: techsupport1@lineagepower.com Europe, Middle-East and Africa Headquarters Tel: +49 89 878067-280 India Headquarters Tel: +91 80 28411633 Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Lineage Power DC-DC products are protected under various patents. Information on these patents is available at www.lineagepower.com/patents. 2009 Lineage Power Corporation, (Plano, Texas) All International Rights Reserved. Document No: DS05-031 ver. 1.31 PDF name: EQD075A.pdf