Keratoconus is one of the most leading causes for visual disability

Similar documents
10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

The Aberration Structure of the Keratoconic Eye

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

Refractive Power / Corneal Analyzer. OPD-Scan III

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction

Aberrations Before and After Implantation of an Aspheric IOL

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

Principles and clinical applications of ray-tracing aberrometry (Part II)

Keratoconus contact lenses

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Aberrometry in Clinical Practice

Customized intraocular lenses

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

Optical Connection, Inc. and Ophthonix, Inc.

Dr. Magda Rau Eye Clinic Cham, Germany

Fitting Manual Use with kerasofttraining.com

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

DESIGNED FOR SUCCESS...GUARANTEED TO FIT

Posterior corneal aberrations and their compensation effects on anterior corneal. aberrations in keratoconic eyes. Minghan Chen and Geunyoung Yoon

Fitting Manual Use with

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Customized Correction of Wavefront Aberrations in Abnormal Human Eyes by Using a Phase Plate and a Customized Contact Lens

ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

What s New in Ocular Biomechanics?


Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals

Effects of Pupil Center Shift on Ocular Aberrations

Experience with correcting myopia with different types of contact lenses

ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

(495) (495)

This is the author s version of a work that was submitted/accepted for publication in the following source:

ClearKone Restoring vision. Changing lives.

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Introducing a lens that can take your scleral fitting to a higher plane.

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Unique Aberration-Free IOL: A Vision that Patients

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

Explanation of Aberration and Wavefront

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Improving Lifestyle Vision. with Small Aperture Optics

What s a Corneal GP Lens?

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Siesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs.

The soft approach to RGPs

FEATURE ARTICLE ON LINE. Uncorrected Wavefront Error and Visual Performance During RGP Wear in Keratoconus

SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009

Trouble Shooting Guide for Ortho-K lenses

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

Irregular Corneas. Expanding Your Lens Options for SPECTRUM. Experts discuss a customized soft lens that delivers visual acuity and comfort.

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

The War against Corneal Warpage

Introducing an enlightened scleral lens designed specifically for regular corneas.

FITTING GUIDE. Applications. Design Options THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Normal Wavefront Error as a Function of Age and Pupil Size

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

ATLAS Corneal Topography System

FOR PRECISE ASTIGMATISM CORRECTION.

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Multifocal Contact Lenses. Steps for Success. Disclosures. Patient Selection. Presbyopic Soft Contact Lenses: Options for Success

case report Scleral lens fit based on OCT data

CONTACT LENSES FOR KERATOCONUS & ALL IRREGULAR CORNEAS

Aberrations and Visual Performance: Part I: How aberrations affect vision

HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design

ROTATIONAL STABILITY MAKES THE DIFFERENCE

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.

Characterizing the Wave Aberration in Eyes with Keratoconus or Penetrating Keratoplasty Using a High Dynamic Range Wavefront Sensor

Subjective Image Quality Metrics from The Wave Aberration

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Better Optics Deliver Clear, Consistent Vision

Showcasing the Innovative Lens Design Portfolio that will Maximize Your Patient s Vision. Carri Russell, FCLSA, COT

FOR FREQUENT REPLACEMENT SOFT HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

4/11/2016 DISCLOSURES DR. EIDEN (CONSULTING, LECTURER, RESEARCH, OR FINANCIAL INTEREST*)

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

A Study of the Effectiveness of CK One-Step Lenses for Correcting Myopia

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

OPH 260 BASIC CONTACT LENS CONCEPTS

Auto Ref / Keratometer ARK-560A / 530A / 510A

OPTOMETRY. I COMMENTARY I Contact lens fitting following corneal graft surgery. Clin Exp Optom 2003; 86: 4:

THE ASPHERIC PRELOADED INJECTION

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

The Unique Mu l t i f o c a l S i l i c o n e H y d r o g e l

PROFESSIONAL FITTING GUIDE

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP

Roadmap to presbyopic success

Optical aberrations and the eye Part 3

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

Transcription:

ARTICLE A New Fitting Approach for Providing Adequate Comfort and Visual Performance in Keratoconus: Soft HydroCone (Toris K) Lenses Koray Gumus, M.D., FEBOphth. and Nisa Kahraman, M.D. Objective: To evaluate the comfort and visual performance of soft HydroCone (Toris K) silicone hydrogel lenses in keratoconus patients. Methods: Fifty eyes of 50 keratoconic patients who were fitted with the Toris K lens were included in the study. All patients were evaluated at baseline and after 2 weeks of lens wear. Uncorrected and best-corrected visual acuities were measured. Corneal topography, ocular aberrations, and point spread function (PSF) were obtained using NIDEK-OPD Scan. Comfort level and visual performance in daytime and nighttime conditions were scored from 0 to 5 after 2 weeks of lens wear. Results: Best-corrected visual acuity was significantly better with the Toris K lens (P,0.001). Mean increase in visual acuity with the lens was 4.5 lines. Mean K 1,K 2, and K max values significantly decreased with the lens (P,0.001). Both total and higher-order root-mean-square errors were significantly corrected with the Toris K lens (P,0.001 and P¼0.038, respectively). A significant correction of total coma and trefoil aberrations was achieved with the lens. Also, PSF values were significantly increased with the lens (P,0.001). Although comfort scores in 46 eyes (92.0%) were classified as good/excellent, only 4 eyes (8.0%) had moderate comfort scores. Visual acuity was classified as good/excellent in 46 eyes (92.0%) in daytime and in 38 eyes (76%) in nighttime conditions. Conclusions: Soft HydroCone silicone hydrogel keratoconus lenses should be considered as alternative visual correction for keratoconus patients. The soft and full-custom design provides optimal comfort and visual performance for the patients daily requirements. Key Words: Keratoconus Contact lens Soft HydroCone contact lens. (Eye & Contact Lens 2015;0: 1 6) Keratoconus is one of the most leading causes for visual disability in the developed world. It is typically diagnosed in the patient s adolescent years. 1 3 With contemporary technological and medical advancements such as improved corneal topographic systems, early signs of keratoconus have been detected, resulting in an apparent increase in the incidence and prevalence of keratoconus. 4 Keratoconus can cause different kinds of visual distortions, such as ghosting, multiple images, glare, halos, starbursts around lights, From the Ocular Surface & Contact Lens Division (K.G., N.K.), Department of Ophthalmology, Erciyes University School of Medicine, Kayseri, Turkey. Presented in part at the 44th ECLSO Meeting, October 10 and 11, 2014, Dubrovnik, Croatia. The authors have no relevant funding or conflicts of interest to disclose. Address correspondence to Koray Gumus, M.D., FEBOphth., Erciyes University School of Medicine, Department of Ophthalmology, Kayseri 38039, Turkey; e-mail: drkorayg@hotmail.com Accepted July 20, 2015. DOI: 10.1097/ICL.0000000000000183 and blurred vision. 1,2 Multiple unsatisfactory attempts to obtain optimum spectacle correction should be a warning sign of keratoconus for clinicians. Visual rehabilitation is certainly the most important step in management. Although patients with early keratoconus may successfully use spectacles or spherical/toric soft contact lenses (SCLs), patients with moderate-to-advanced keratoconus often require other alternatives, including rigid contact lenses, hybrid lenses, piggyback contact lenses, scleral lenses, intrastromal corneal rings, phakic intraocular lenses, and eventually corneal transplantation. 5 8 Even though gas-permeable contact lenses have been widely used for many years because of their success in improving visual acuity, prolonged use may lead to lens intolerance and ocular discomfort in most patients with keratoconus. 9 In such cases, today s special design SCLs for keratoconus should be considered. One type of lens is soft HydroCone (Toris K) lens (SwissLens, Prilly, Switzerland), which have a silicone hydrogel material (definite 74/Igel 77). Toris K lenses include a front toric surface and have a dynamic stabilization with nasal and temporal bumps. Toris K lenses cause spherical with aspherical flattening on the back surface. Basically, there are 2 types of lenses in a trial set: HydroCone-K12 (for grade 1 2 keratoconus) and HydroCone-K34 (for grade 3 4 keratoconus). In this research, we aimed to evaluate the comfort and visual performance of this new alternative approach, soft HydroCone silicone hydrogel lenses, in keratoconus patients. MATERIALS AND METHODS This study was approved by the Institutional Review Board of the Erciyes University School of Medicine. The research protocol adhered to the tenets of the Declaration of Helsinki for clinical research. Written informed consent was obtained from all the participants after explanation of the purpose and possible consequences of the study. Fifty eyes of 50 keratoconic patients (18 men and 32 women; mean age, 24.5 years; range, 18 45 years) who were fitted with soft HydroCone silicone hydrogel lenses were included in the study. The parameters of the lenses and a fitting guide are shown in Tables 1 and 2. Exclusion criteria included those patients who underwent any ocular surgery, with a history of ocular trauma, or any ocular disease (e.g., active ocular infection, corneal dystrophies, severe dry eye, corneal dystrophies, clinically significant nuclear sclerosis/cataract, etc) that might affect the results. Eye & Contact Lens Volume 0, Number 0, Month 2015 1

K. Gumus and N. Kahraman Eye & Contact Lens Volume 0, Number 0, Month 2015 TABLE 1. Technical Data The Fitting Set Parameters of Soft HydroCone (Toris K) Lens Values Total diameter 13.70 mm (HydroCone K12) 14.00 mm (HydroCone K34) Base curve 7.20 to 8.40 D Sphere 240.0 to +40.0 D Cylinder 20.01 to 28.00 D Axis 0 180 Optimized center thickness Flattening HydroCone K12+ HydroCone K34++ Standard K12¼0.42 mm, K34¼0.52 mm Range of thickness: 0.3520.59 mm All patients were evaluated at baseline and after 2 weeks of lens wear. Uncorrected and best-spectacle-corrected visual acuities were measured with the logarithm of the minimum angle of resolution (logmar) chart (Smart System II 2020 Visual Acuity System; M&S Technologies, Inc, Skokie, IL). Subjective refraction, including spherical error, cylindrical error, and spherical equivalent (spherical error+[cylindrical error/2]) were performed. Biomicroscopy and fundoscopy were also performed. Corneal topography, ocular aberrometry, and point spread function (PSF) (the Strehl s ratio) were obtained using NIDEK- Optical Path Difference Scanning System ARK-10000 refractive power/corneal analyzer (version 1.12iAC; NIDEK, Co, Ltd, Gamagori, Japan). Three images were recorded for each eye across a natural (undilated) pupil. The image with the best alignment and at least six digitized rings were selected for analysis. The simulated keratometry values in the two major axes were noted from each selected axial map. Ocular aberrations were measured using sixth-order Zernike s polynomials decomposition. The parameters analyzed included the rootmean-square (RMS) values of total aberrations (Total), tilt (S1), higher-order aberrations (HOA), total coma (T. Coma) aberrations, total trefoil (T. trefoil), total tetrafoil (T. 4foil), TABLE 2. Fitting Assessment Procedure of Soft HydroCone (Toris K) Lens First contact lens choice It is suggested working with trial lenses with cylindrical power 20.01 D Keratoconus classification First apply topographical indications or follow the rules: Vcc.0.6 and/or keratometry.6.8: grade 1 or 2 (choose HydroCone K12) Vcc,0.6 and/or keratometry,6.8: grade 3 or 4 (choose HydroCone K34) Diameter and base curve selection Add 0.8 diopters to the average K value, then select a trial lens HydroCone K12/ØT¼14.00 mm HydroCone K34/ØT¼13.70 mm Further steps The first lens helps to validate base curve and total diameter The patient should wait for 30 min Dynamic stabilization marks should be evaluated to measure the stabilization axis Push-up test should be done The fitting curve should demonstrate typical fitting of characteristics of a standard soft lens fit If the fitting curve is too flat, there will be excessive movement and/or edge lift, then switch to a steeper trial lens Little or no movement and/or edge impingement would indicate the fitting curve is too steep, then switch to a flatter trial lens Over refraction should be done Prescription should include both spherical and cylindrical errors with its axis In case of glare and/or halo, you can request to enlarge the optical zone ØT, total diameter. total spherical aberrations (T. Sph), and higher-order astigmatism (HiAstig). Ocular health status, including bulbar hyperemia and corneal and conjunctival staining, was also evaluated. Comfort level and visual performance in both daytime and nighttime conditions were scored from 0 to 5 (0, worst; 1, bad; 2, fair; 3, moderate; 4, good; 5, excellent) after 2 weeks of lens wear. The data were analyzed using SPSS 20.0 for Mac (SPSS, Inc, Chicago, IL). A paired sample t test was performed to compare the difference in the means before and after fitting the lens. The correlations between the two study parameters were analyzed using the Spearman s correlation test. A P value of,0.05 was considered statistically significant. RESULTS Although 10 patients (20.0%) wore nothing for visual rehabilitation, 35 patients (70.0%) wore glasses and 5 patients (10.0%) wore rigid gas-permeable (RGP) contact lenses before the study. Thirty eyes (60.0%) had a history of accelerated corneal crosslinking (CCL) with riboflavin/uv-a (30 minutes+9 minutes) in our clinic. These eyes were fitted with the lens at least 6 months after the uneventful CCL. Best-corrected visual acuity was significantly better with the lens than that with spectacles (P,0.001) (Fig. 1). When using the log- MAR chart, the mean increase in logmar visual acuity with the Toris K lens was 4.5 lines (range, 1 9 lines). With the Toris K lens, mean K1, K2, and K max values were significantly decreased by 6.463.1 (from 51.4 to 45.0), 3.963.3 (from 46.3 to 42.4), and 7.963.6 diopters (from 54.5 to 46.6), respectively (P,0.001). Moreover, mean baseline topographical spherical equivalent values were significantly decreased from 26.0 to 21.3 with the lens (P,0.001). Both total and higher-order (HO) ocular RMS wavefront errors were significantly corrected with the Toris K lens (P,0.001 and P¼0.038, respectively). A detailed analysis of HO aberrations revealed a significant correction of total coma and trefoil aberrations with the lens. However, other aberrations such as tetrafoil, spherical, and HO astigmatism RMS values were nearly identical. Moreover, PSF, the Strehl s ratio, was significantly increased with the lens (P,0.001). The higher the Strehl s ratio, the better the potential image quality. Details of above-mentioned analysis are given in Figure 2. An example of corneal topography before and after fitting the lens is shown in Figure 3. A subgroup analysis was performed according to the history of CCL. All ocular aberration and PSF values were compared in two groups to evaluate the impact of CCL on visual performance of the Toris K lens. Data regarding this analysis are summarized in Table 3. Although comfort score in 46 eyes (92.0%) was classified as good/excellent, only 4 eyes (8.0%) had moderate comfort scores. Visual acuity was classified as good/excellent in 46 eyes (92.0%) in daytime and in 38 eyes (76%) in nighttime conditions. Among the study parameters, lower total coma and the higher Strehl s ratio values appeared to be correlated to better visual performance in daytime (20.352/P¼0.014 and 0.334/P¼0.020, respectively). In addition, visual performance in nighttime conditions was negatively correlated with larger photopic and mesopic pupil sizes (20.376/P¼0.007 and 20.401/P¼0.004, respectively). 2 Eye & Contact Lens Volume 0, Number 0, Month 2015

Eye & Contact Lens Volume 0, Number 0, Month 2015 Soft HydroCone Lenses for Keratoconus FIG. 1. Box plot reveals that the Toris K contact lens provides much better logmar (logarithm of the minimum angle of resolution) visual acuity levels according to the uncorrected and corrected values with spectacles. DISCUSSION The range of contact lens options in the market for the successful optical correction of keratoconus has greatly expanded over the past few decades. In this study, we assessed the optical performance of a new soft HydroCone (Toris K) silicone hydrogel lens for keratoconus. In early keratoconus, spherical and toric SCLs can provide successful optical correction. 5,10 While selecting SCL, thicker lenses with low water content should be preferred to neutralize the irregular astigmatism. 5 However, with increasing severity of keratoconus, these lenses are not given preference because of their inadequate optical performance. So, management should be switched to other lens modalities such as RGP lenses, hybrid lenses, piggyback lenses, and scleral lenses, depending on the severity and location of the cone. 5 In keratoconus patients, RGP lenses have been used as the first lens of choice for visual improvement since the late 1970s because of their benefits such as better vision, oxygen permeability, and simple cleaning procedures. The overall purpose of RGP contact lenses in keratoconus is to provide vision correction by masking the anterior corneal surface irregularity and secondary visual distortion through the creation of a regular anterior optical surface. A tear layer at the posterior surface of the lens may contribute to refractive error correction by compensating for slight irregularities of the corneal anterior surface. 11 One important disadvantage of these lenses is the potential to damage the cornea, which has been largely overcome by specially designed multicurve RGP lenses. 12 Even, these newer designs of keratoconic RGP lenses should be fit without touching the apical cornea. Numerous studies have demonstrated that the use of RGP lenses can also improve visual performance by altering ocular aberrations and increasing contrast sensitivity 13 15 ; however, ocular discomfort as a result of the rigid material of the lens still remains the most common reason for discontinuation. In addition, rigid lenses still have the potential to decenter, entrap dust or debris, and dislodge. In these patients who become intolerant to RGP contact lenses, other options should be evaluated. Switching from the rigid to TABLE 3. Total and Higher-Order Aberrations and Point Spread Function Data at Baseline and With the Toris K Lens According to the History of Corneal Cross-linking No CXL (n¼20) CXL (n¼30) Parameters Baseline Toris K P Baseline Toris K P T. aberration 3.5461.21 1.8661.00,0.001 3.7761.46 1.2960.45,0.001 T. HOA 0.8360.59 0.7160.67 0.583 0.7460.30 0.4960.23 0.001 T. coma 0.3860.25 0.3260.33 0.479 0.4760.19 0.2360.15,0.001 T. trefoil 0.5560.39 0.4060.30 0.192 0.5460.29 0.3360.13,0.001 T. tetrafoil 0.2060.43 0.1860.45 0.918 0.0960.04 0.1160.11 0.449 T. spherical 0.1360.09 0.1660.16 0.526 0.1360.08 0.1160.09 0.204 T. HOAst 0.1160.05 0.1360.12 0.466 0.0960.03 0.1260.09 0.111 PSF 0.0360.03 0.0560.04 0.056 0.0260.02 0.0560.03,0.001 Bold numbers represent statistically significant P values. CXL, corneal cross-linking with riboflavin/uv-a; HOA, higher-order aberration; HOAst, higher-order astigmatism; PSF, point spread function; T, total. Ó 2015 Contact Lens Association of Ophthalmologists 3

K. Gumus and N. Kahraman Eye & Contact Lens Volume 0, Number 0, Month 2015 FIG. 2. Box plots reveal the change of total and higher-order aberration RMS (root-mean-square) values and PSF (point spread function) ratio with the Toris K lens. 4 Eye & Contact Lens Volume 0, Number 0, Month 2015

Eye & Contact Lens Volume 0, Number 0, Month 2015 Soft HydroCone Lenses for Keratoconus FIG. 3. An example of an Optical Path Difference scan before (left side) and after (right side) fitting the Toris K lens. Ó 2015 Contact Lens Association of Ophthalmologists 5

K. Gumus and N. Kahraman Eye & Contact Lens Volume 0, Number 0, Month 2015 soft material seems to be logical to alleviate lens-related ocular discomfort. Currently, there are few studies that have addressed the question of whether soft keratoconus lenses can provide adequate vision as compared with rigid lenses. One possible way to increase visual performance of SCLs is the customization of lenses. Marsack et al. 16 produced such a lens and evaluated whether custom wavefront-guided SCLs provide visual and optical performance equivalent to habitual gas-permeable corrections. Finally, this investigation concluded that custom wavefront-guided SCLs can provide equivalent photopic highcontrast logmar visual acuity to that achieved with rigid lens correction in three keratoconus subjects. 16 Other alternatives may include KeraSoft IC (Bausch & Lomb, Inc., Rochester, NY) and NovaKone (Alden Optical, Lancaster, NY) soft lenses, which are also designed for the keratoconic eye. 17 These lenses can be a viable solution for all stages of keratoconus and seem to be good alternatives to RGP lenses before trying to fit more sophisticated lenses such as hybrid or scleral lenses. 17 In this study, a new alternative, soft HydroCone (Toris K) silicone hydrogel keratoconus lenses, was investigated in detail. These lenses can be categorized as full-custom lenses because both spherical and cylindrical corrections are added to the toric surface of the lens to increase the visual performance. In our case series, BCVA values were significantly better with the lens than with the spectacles (P,0.001). When compared with spectacles, the mean increase in visual acuity with the Toris K lens was 4.5 lines (range, 1 9 lines). With the Toris K lens, mean K1, K2, and K max values and baseline topographical spherical equivalent values were significantly decreased (P,0.001). All these results are better than RGP lenses as documented in the literature. Moreover, both total and HO ocular RMS wavefront errors significantly corrected with the Toris K lens (P,0.001 and P¼0.038, respectively), which is an important indicative value of satisfactory visual performance. A detailed analysis revealed that although total coma and trefoil aberrations were significantly corrected with the Toris K lens, other aberrations such as tetrafoil, spherical, and HO astigmatism RMS values were nearly identical. Whereas, another study showed that the use of RGP contact lenses exhibited a large corrective effect on spherical aberration. 11 This diversity can be attributed to different design, material, and functional properties of these two different lenses. Furthermore, PSF, the Strehl s ratio, was significantly increased with the lens (P,0.001), meaning much better image quality. Both these results and survey scores implied that Toris K provides satisfactory visual performance particularly in daytime. This performance seems to decline at night because of glare and halos reported by some patients with larger photopic and scotopic pupils. The association between history of CCL and clinical outcomes using the lens was analyzed in this study. Interestingly, a strong association was found in which CCL seems to contribute to better visual performance in patients fitted with the Toris K lens. This issue is still being investigated in our ongoing studies to clarify this association in a larger sample size. To date, the results reported here demonstrate that soft Hydro- Cone (Toris K) silicone hydrogel keratoconus lenses should be considered as a new alternative fitting approach for keratoconus patients. A customized lens design provides optimal comfort and visual performance for the patients daily requirements. ACKNOWLEDGMENTS The authors thank Professor Dwight Cavanagh (Department of Ophthalmology, UT Southwestern Medical Center, Dallas, TX) for his outstanding editing and proof reading of the manuscript. REFERENCES 1. Krachmer JH, Feder RS, Belin MW. Keratoconus and related noninflammatory corneal thinning disorders. Surv Ophthalmol 1984;28:293 322. 2. Rabinowitz YS. Keratoconus. Surv Ophthalmol 1998;42:297 319. 3. Davidson AE, Hayes S, Hardcastle AJ, et al. The pathogenesis of keratoconus. Eye (Lond) 2014;28:189 195. Review. 4. Rabinowitz YS. Corneal topography. Curr Opin Ophthalmol 1993;4:68 74. Review. 5. Barnett M, Mannis MJ. Contact lenses in the management of keratoconus. Cornea 2011;30:1510 1516. Review. 6. Ertan A, Colin J. Intracorneal rings for keratoconus and keratectasia. J Cataract Refract Surg 2007;33:1303 1314. Review. 7. Kamiya K, Shimizu K, Kobashi H, et al. Three-year follow-up of posterior chamber toric phakic intraocular lens implantation for the correction of high myopic astigmatism in eyes with keratoconus. Br J Ophthalmol 2015;99: 177 183. 8. Romano V, Iovieno A, Parente G, et al. Long-term clinical outcomes of deep anterior lamellar keratoplasty in patients with keratoconus. Am J Ophthalmol 2015;159:505 511. 9. Wu Y, Tan Q, Zhang W, et al. Rigid gas-permeable contact lens related life quality in keratoconic patients with different grades of severity. Clin Exp Optom 2015;98:150 154. 10. Jinabhai A, Radhakrishnan H, Tromans C, et al. Visual performance and optical quality with soft lenses in keratoconus patients. Ophthalmic Physiol Opt 2012;32:100 116. 11. Yu Q, Wu JX, Zhang HN, et al. Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses. Int J Ophthalmol 2013;6:178 182. 12. Hwang JS, Lee JH, Wee WR, et al. Effects of multicurve RGP contact lens use on topographic changes in keratoconus. Korean J Ophthalmol 2010;24:201 206. 13. Griffiths M, Zahner K, Collins M, et al. Masking of irregular corneal topography with contact lenses. CLAO J 1998;24:76 81. 14. Loretta B, Szczotka F, Shamil P. Menicon Z rigid gas permeable lenses for keratoconus and irregular corneas: A retrospective case series. Eye Contact Lens 2008;34:254 260. 15. Kazuno N, Takashi K, Yoshikazu U, et al. Effect of higher-order aberrations on visual function in keratoconic eyes with a rigid gas permeable contact lens. Am J Ophthalmol 2007;144:924 929. 16. Marsack JD, Parker KE, Applegate RA. Performance of wavefront-guided soft lenses in three keratoconus subjects. Optom Vis Sci 2008;85:E1172 E1178. 17. Uçakhan OO, Bayraktutar B. KeraSoft 3 contact lenses in corneal ectasia. Eye Contact Lens 2014;40:390 394. 6 Eye & Contact Lens Volume 0, Number 0, Month 2015