Pulsed Laser Power Measurement Systems

Similar documents
Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Solid State Luminance Standards

We bring quality to light. MAS 40 Mini-Array Spectrometer

Photodiode Heads and Instruments

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

LEADING THE WAY in Light Measurement Systems

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

LED Lighting Flux and Color Measurement System (LFC)

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

Thermal Heads for Power and Single-Shot Energy - mw to KW, mj to 300J

Chameleon Spectroradiometer

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

NIRCam optical calibration sources

Tunable KiloArc. Tunable Broadband Light Source.

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

New automated laser facility for detector calibrations

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

How-to guide. Working with a pre-assembled THz system

BTS2048-VL-CP-ILED-B-IS-1.0-HL

improved stability (compared with

Power Meters and Detectors

UPK Series - Precision Integrating Spheres with Synthetic ODM98 Coating

Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions

pulsecheck The Modular Autocorrelator

Atlantic. Industrial High Power Picosecond Lasers. features

TEST MEASUREMENT CHAPTER Goniophotometer. Integrating Sphere System.

illumia Plus Temperature Controlled Light Measurement Systems

Silicon Avalanche Photodiode SAR-/SARP-Series

Status of Low-Background Infrared Calibration Facility at NIST

Power Sensors Introduction

The CORONA Dryer and Blender

Fully Portable Spectrophotometer for Transmission Measurement

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Miniature Spectrometer Technical specifications

Vixar High Power Array Technology

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Improved Radiometry for LED Arrays

Novel laser power sensor improves process control

JETI Specbos Instruments

RADIATION BUDGET INSTRUMENT (RBI): FINAL DESIGN AND INITIAL EDU TEST RESULTS

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

Spectroradiometer specbos 1201

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

Application Note (A16)

HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

POWER DETECTORS. How they work POWER DETECTORS. Overview

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

The ASTRI SST-2M Illuminator

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

A-CUBE-Series High Sensitivity APD Detector Modules

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Optical and Quantum Electronics (2005) 37: Ó Springer 2005 DOI /s

LED Tester BTS256-LED

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS

Atlantic. Industrial High Power Picosecond Lasers. features

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

LI-1500 Light Sensor Logger

Infrared wire grid polarizers: metrology, modeling, and laser damage threshold

LBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations

WARRANTY. Any unauthorized alteration or repair of the product is also not covered by the warranty.

LTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2

PLCC-2 Pkg Infrared Light Emitting Diode

Radiometric performance of Second Generation Global Imager (SGLI) using integrating sphere

P-CUBE-Series High Sensitivity PIN Detector Modules

Supercontinuum Sources

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

Laser Speckle Reducer LSR-3000 Series

Pyroelectric, Photodiode and RP Heads for Repetitive Energy Measurements

OP710. Multichannel Optical Power Meter Instruction Manual. (Also supports the OP710-ANX)

PGS Family Plane Grating Spectrometer from ZEISS

NOW WITH BROADER TUNING RANGE

Standard InGaAs Photodiodes IG17-Series

End Capped High Power Assemblies

MS260i 1/4 M IMAGING SPECTROGRAPHS

Extended InGaAs Photodiodes IG22-Series

Influence of the light spectral distribution used in the radiometers calibration

SPECTRAL IRRADIANCE DATA

The FTNIR Myths... Misinformation or Truth

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

Aurora II Integra OPO Integrated Nd:YAG Pumped Type II BBO OPO

Measurements of Infrared Sources with the Missile Defense Transfer Radiometer

How to Avoid Thermal Sensor Damage & Out of Tolerance Conditions

Sensor Fusion Enables Comprehensive Analysis of Laser Processing in Additive Manufacturing

LI-193 Spherical Quantum Sensor

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

Miniaturized Laser Speckle Reducer OEM Series

Zenith Polymer Diffuse Reflectance Standards, Targets and Materials. ... your Partner in Lighting Technology!

Wavelength LDH - P / D - _ / C / F / FA / TA - N - XXX - _ / B / M / L / XL. Narrow linewidth (on request) Tappered amplified

Advances in Measuring UV LED Arrays

White Paper: Modifying Laser Beams No Way Around It, So Here s How

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

LI-192 Underwater Quantum Sensor

AvaLight-DHc Full-range Compact Light Source

CDRH 21 CFR Part 1040 Informative Laser Report

Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Oriel MS260i TM 1/4 m Imaging Spectrograph

Deschutes Series InGaAs Avalanche Photodiodes

DL Blue Laser Diode in TO38 ICut Package. PRELIMINARY Datasheet. Creative Technology Lasers (925) Tele.

Transcription:

Pulsed Laser Power Measurement Systems Accurate, reproducible method of determining total laser and laser diode power Ideal for Beam Power Measurement Labsphere s Pulsed Laser Power Measurement Systems assure an accurate, reproducible method of determining the total power from a collimated or divergent laser or laser diode. Specifically designed for laser applications, the spheres are ideal for measuring the total power of a beam of optical radiance. Because of the unique geometry of the sphere, beam power measurements are independent of beam polarization, and are insensitive to beam alignment. The attenuation which accompanies the sphere throughput also alleviates detector saturation. The systems can be used with an open port and can be apertured with an array of optional fiber adaptors for laser diode modules or port reducers. Flexible Design Each system consists of a laser power measurement sphere, post, post holder and base assembly, a detector assembly, and multi-wavelength calibration. A second detector port gives the user the flexibility to add an additional detector assembly for broader spectral sensitivity, or add a spectrometer for spectral characterization. An input port that permits a beam of radiation is machined into the sphere. A detector, located 45 from the entrance port, views the sphere wall next to the entrance port. The field of view of the detector is designed to limit the viewing area so that highly divergent sources may be input without effecting measurement accuracy. The systems provide options for laser power measurement over the 350 to 1700 nm wavelength region for optical powers ranging from nw to hundreds of watts. The system s calibrations are traceable to the National Institute of Standards and Technology (NIST). The 2, 4, or 6 inch diameter integrating spheres are coated with either Labsphere s Spectraflect or Infragold, or fabricated from Spectralon, our highly reflective diffuse material. All options are durable and highly stable over time. These diffuse reflective interiors ensure the accurate integration of light. Value Spectraflect, Infragold or Spectralon sphere interiors for reduced alignment sensitivity Sturdy port frames for mounting fiber accessories Second detector port for a spectrometer or additional fiber Three integrating sphere size options Two detector options NIST traceable system calibrations Measures Lasers Laser diodes Laser diode modules Divergent monochromatic sources Pulsed laser

Example of Labsphere s Laser Power Measurement Software Reported values include: Average Radiant Power at nth wavelength (CW) Average Peak Radiant Power at nth wavelength (pulsed) COV (CW) Detector Sampling Rate (Hz) Detector Scan Interval (sec) Laser Power Density: the instantaneous laser beam power per unit area. W/cm 2 with option to beam area in cm 2 Require input of beam area Max Power (CW) Min Power (CW) Overrange Warning Peak Radiant Power (Pulsed) Pulse width or interval of duration of a pulse Radiant Power Range (CW) Radiant Power (W) Repetition Rate/Frequency (Pulsed) Standard Deviation (CW) Threshold Max for given LPMS detector sensitivity range and system responsivity Threshold Min for given LPMS detector sensitivity range and system responsivity Total Measurement Time: not necessarily the same as the laser emission duration during the measurement. sec Total Pulses Wavelength (chosen by customer based on laser output and data table from calibration

For lower power VIS NIR lasers Part Number LPMS-020-SF-SDTP LPMS-040-SF-SDTP LPMS-060-SF-SDTP Sphere Material: Spectraflect Spectraflect Spectraflect Sphere Diameter: 2 inch 4 inch 6 inch Sensor: Silicon Silicon Silicon Spectral Range: (nm) 350 1100 350 1100 350 1100 Spectral Peak: (nm) 975 975 975 Spectral Responsivity: (A/W) 5.7E-4 @975 1.4E-4 @975 6.3E-5 @975 Minimum Power at 975 nm: 1.8 nw 7.0 nw 1.6 nw Maximum Power at 975 nm: 1.8 W 7 W 16 W For mid-power lasers in VIS NIR, more robust Part Number LPMS-020-SL-SDTP LPMS-040-SL-SDTP LPMS-060-SL-SDTP Sphere Material: Spectralon Spectralon Spectralon Sphere Diameter: 2 inch 3.3 inch 5.3 inch Sensor: Silicon Silicon Silicon Spectral Range: (nm) 350 1100 350 1100 350 1100 Spectral Peak: (nm) 975 975 975 Spectral Responsivity: (A/W) 9.7E-5 @975 3.6E-5 @975 5.0E-6 @975 Minimum Power at 975 nm: 10 nw 28 nw 200 nw Maximum Power* at 975 nm: 10 W 28 W 200 W * Actual maximum power based on thermal limits of sphere coating and/or material. Contact our sales engineers for further information.

For lower power NIR lasers Part Number LPMS-020-SF-IDTP LPMS-040-SF-IDTP LPMS-060-SF-IDTP Sphere Material: Spectraflect Spectraflect Spectraflect Sphere Diameter: 2 inch 4 inch 6 inch Sensor: InGaAs InGaAs InGaAs Spectral Range: (nm) 900-1700 900-1700 900-1700 Spectral Peak: (nm) 1300 1300 1300 Spectral Responsivity: (A/W) 9.4E-5 @1300 2.0E-5 @1300 1.0E-5 @1300 Minimum Power at 1300 nm: 10 nw 50 nw 100 nw Maximum Power* at 1300 nm: 10 W 50 W 100 W For mid-power lasers in NIR, more robust Part Number LPMS-020-SL-IDTP LPMS-040-SL-IDTP LPMS-060-SL-IDTP Sphere Material: Spectralon Spectralon Spectralon Sphere Diameter: 2 inch 3.3 inch 5.3 inch Sensor: InGaAs InGaAs InGaAs Spectral Range: (nm) 900-1700 900-1700 900-1700 Spectral Peak: (nm) 1600 1600 1600 Spectral Responsivity: (A/W) 2.5E-5 @1600 9.2E-6 @1600 3.6E-6 @1600 Minimum Power at 1600 nm: 40 nw 109 nw 280 nw Maximum Power* at 1600 nm: 40 W 109 W 280 W * Actual maximum power based on thermal limits of sphere coating and/or material. Contact our sales engineers for further information.

For high-power lasers in NIR, higher heat threshold, robust Part Number LPMS-020-IG-IDTP LPMS-040-IG-IDTP LPMS-060-IG-IDTP Sphere Material: Infragold Infragold Infragold Sphere Diameter: 2 inch 3 inch 6 inch Sensor: InGaAs InGaAs InGaAs Spectral Range: (nm) 900-1800 900-1800 900-1800 Spectral Peak: (nm) 1600 1600 1600 Spectral Responsivity: (A/W) 1.4E-5 @1600 3.4E-6 @1600 1.5E-6 @1600 Minimum Power at 1600 nm: 73 nw 290 nw 659 nw Maximum Power* at 1600 nm: 73 W 290 W 659 W * Actual maximum power based on thermal limits of sphere coating and/or material. Contact our sales engineers for further information. Average Spectral Responsivities of LPMS-060-SL-SDTP or IDTP with InGaAs Sensor 1.80E-05 1.60E-05 1.40E-05 1.20E-05 A/W 1.00E-05 8.00E-06 6.00E-06 4.00E-06 2.00E-06 0.00E+00 nm LPMS-060-SL-SDTP LMPS-060-SL-IDTP

Ordering Information Model LPMS-020-SF-IDTP LPMS-020-SF-SDTP LPMS-020-SL-IDTP LPMS-020-SL-SDTP LPMS-040-IG-IDTP LPMS-040-SF-IDTP LPMS-040-SF-SDTP LPMS-040-SL-IDTP LPMS-040-SL-SDTP LPMS-060-IG -IDTP LPMS-060-SF-IDTP LPMS-060-SF-SDTP LPMS-060-SL-IDTP LPMS-060-SL-SDTP LPMS-100-IGC-IDTP LPMS-100-IGC-SDTP SDA-050-HS1 IDA-050-HS1 Description Spectraflect 2 inch, 3 port CW and pulsed laser power measurement system with high speed Spectraflect 2 inch, 3 port CW and pulsed laser power measurement system with high speed Spectralon 2 inch, 3 port CW and pulsed laser power measurement system with high speed Spectralon 2 inch, 3 port CW and pulsed laser power measurement system with high speed Infragold 4 inch, 3 port CW and pulsed laser power measurement system with high speed Spectraflect 4 inch, 3 port CW and pulsed laser power measurement system with high speed Spectraflect 4 inch, 3 port CW and pulsed laser power measurement system with high speed Spectralon 4 inch, 3 port CW and pulsed laser power measurement system with high speed Spectralon 4 inch, 3 port CW and pulsed laser power measurement system with high speed Infragold 6 inch, 3 port CW and pulsed laser power measurement system with high speed Spectraflect 6 inch, 3 port CW and pulsed laser power measurement system with high speed Spectraflect 6 inch, 3 port CW and pulsed laser power measurement system with high speed Spectralon 6 inch, 3 port CW and pulsed laser power measurement system with high speed Spectralon 6 inch, 3 port CW and pulsed laser power measurement system with high speed Water-cooled Infragold 10 inch, 3 port CW and pulsed laser power measurement system with high speed InGaAs detector and control software and UI 900 nm to 1700 nm every 10 nm. Watts at X nm Water-cooled Infragold 10 inch, 3 port CW and pulsed laser power measurement system with high speed Silicon detector and control software and UI 700 nm to 1100 nm every 10 nm. Watts at X nm Silicon Detector Assembly - High Speed. Mounts on PF-050 0.5 inch port frame Silicon Detector Assembly - High Speed. Mounts on PF-050 0.5 inch port frame Order Number AA-01548-400 AA-01548-100 AA-01549-400 AA-01549-100 AA-01550-400 AA-01551-400 AA-01551-100 AA-01552-400 AA-01552-100 AA-01553-400 AA-01554-400 AA-01554-100 AA-01555-400 AA-01555-100 AA-01556-400 AA-01556-100 AS-81067-000 AS-81067-001 Optional Accessories SMA-050-SF/SL Adaptor, SMA, 0.5, SF/SL AS-02428-004 SMA-100-SF/SL Adaptor, SMA, 1.0, SF/SL AS-02428-008 SMA-050-IG Adaptor, SMA, 0.5, Infragold AS-02432-004 SMA-100-IG Adaptor, SMA, 1.0, Infragold AS-02432-008 SMA-050-FB Adaptor, SMA, 0.5, Flat Black AS-02436-004 SMA-100-FB Adaptor, SMA, 1.0, Flat Black AS-02436-008