Data sheet DS/ EN Rev. F a rugged, reliable recorder for all single channel recording applications Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers included as standard NEMA X/IP construction hosedown protection Optional Totalizer function 8-digit Flow totalizer -digit indicator panel continuous display of process value
DS/ EN Rev. F The is a single pen, fully programmable circular chart recorder. The instrument s straightforward operator controls and robust construction make it suitable for a variety of industrial environments. Easy to Install A choice of mounting options enables simple installation of the recorder in a panel, on a wall or on a pipe. Mains isolation can be provided by an optional power switch within the instrument. Designed to Survive NEMA X protection ensures the can survive in the harshest environments and makes the recorder ideal for use in panels which are regularly hosed down. The tough, acidresistant case and secure cable-entry glands maintain the NEMA X rating for wall-mount or pipe-mount instruments. Wall-mounting Pipe-mounting Panel-mounting 2
DS/ EN Rev. F Specification General Construction Size Weight Case material Window Material Door latch 15.2 in. (h) x 15.0 in. (w) x 5.57 in. (d) (8.8 x 128.0 x 11.5mm) 18lb (8.2kg) Glassfiber-filled reinforced polyester Polycarbonate High-compression with optional lock Environmental Operational temperature range 2 to 10 F (0 to 55 C) Operational humidity range 5 to 95%RH (non-condensing) 5 to 80%RH (chart only) Case sealing NEMA X (IP) Fast transients IEC 801- Level Installation Mounting options Terminal type Wire size (max) Operation and Configuration Programming method Security Safety General safety Isolation Memory protection Approvals CE CSA CSA/FM Class 1 Div. 2 UL Panel, wall or pipe Screw 1 AWG (I/O), 12 AWG (power) Via front panel keys Password protected menus IEC8 2kV DC (channel/ground) Nonvolatile FRAM (option) (option) (option) Power Supply Voltage 100 to 20V AC ±10% (90V min. to 2V AC max.) 50/0Hz Consumption <0 VA Line interruption Up to 0ms Process Input General Noise Rejection CJC rejection ratio Sensor break protection Out of range detection Temperature stability Long-term drift Input impedance Common mode >120dB at 50/0Hz Normal (series) mode >0dB at 50/0Hz <0.05 C/ C Upscale or downscale drive 0 to 100% of engineering span <0.02% of reading/ C or 1μV/ C <0.01% of reading 10μV annually >10 MΩ (mv and V inputs) 100 Ω (ma input) Analog Input Signal types mv, V, ma, Ω Thermocouple types B, E, J, K, N, R, S, T Resistance Thermometer Pt 100 Other linearizations x /2, x 5/2, square root Sample interval 250ms Digital Filter 0 to 0s programmable Recording System Pen Color Response Resolution Pen lift Chart Chart size Chart speed Rotation accuracy Red 7 seconds (full scale) 0.1% steps Motor-driven, with optional auto-drop 10 in. or 105mm 1 to 17 hours or 7 to 2 days per revolution <0.5% of rotation time Display and Operator Panels Displays Type -digit red LED, 0.5 in. (1mm) high Panel keys Function Programming access, increment/decrement, pen lift and user-defined function key `Totalizer Size Count direction Preset 99,999,999 max. Up or down User-programmable EMC Emissions and Immunity Meets requirements of: EN50081-2 EN50082-2 EN12 for an industrial environment CE mark
DS/ EN Rev. F Analog Input Performance Type V Range Lo Range Hi Min. Span Accuracy m 0 150 5 ± 0.1% reading or 10μV V 0 5 0. 1 ± 0.1% reading or 20mV ma 0 50 1 ± 0.2% reading or 0. 2μA Ohms (low) 0 750 20 ± 0.2% reading or 0. 1Ω Ohms (high) 0 10k 00 ± 0.5% reading or 10Ω C F Type Range Low Range High Range Low Range High Accuracy (excl. CJC) B 18 1800 0 270 ± 2. 0 C (above 200 C) E 100 900 10 150 J 100 900 10 150 K 100 100 10 250 N 200 100 25 250 R 18 1700 0 000 ± 1. 0 C (above 00 ) S 18 1700 0 000 ± 1. 0 C (above 200 C) T 250 00 00 550 Pt100 200 00 25 1100
X DS/ EN Rev. F Wiring Connections + + + Voltage Thermocouple Low Voltage (mv) + 5 Red White Red 5 Link White Red Current -wire RTD Standard Input Connections 2-wire RTD and Resistance Earth (Ground) Stud 2 5 Line Neutral Power Switch (Optional) Fuse (Optional) Power Supply Connections 5
DS/ EN Rev. F Overall Dimensions Dimensions in mm (in.) 15.0 (82) 15.2 (8) 1.0 () 2.0 () 1.8 (5) Typical Space Between Adjacent Knockout Centers 7.22 (18.) 12. (20.8) 1. (.) 0.88 (22.5) 12. (20.8)
DS/ EN Rev. F Ordering Information 1901 X X 0 X X X 0 0 0 0 0 XXXX Chart Type Build Taylor (ER/C) charts KPC 105, Kent PX and Kent PXR type charts Chessel brand charts ABB Standard CSA approved CSA/FM Class 1 Division 2 approved UL approved Options None Totalizer Door Lock Not fitted Fitted Power Supply 115V AC 20V AC 115V AC with On/Off switch 20V AC with On/Off switch Programming/Special Features Configured to factory standard Configured to customer requirements Special features J K C A B F U 0 1 2 1 2 5 STD CUS SPXX 7
Contact us ABB Limited Process Automation Howard Road St. Neots Cambridgeshire PE19 8EU UK Tel: + (0)180 7521 Fax: + (0)180 21798 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 1897 USA Tel: +1 215 7 000 Fax: +1 215 7 718 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2011 ABB All rights reserved KXR200105R1001 DS/ EN Rev. F 07.2011 www.abb.com