DOWEL ACTION OF TITANIUM BARS CONNECTING MARBLE FRAGMENTS AT DIFFERENT ANGLES

Similar documents
Nonlinear behavior of Reinforced Concrete Infilled Frames using ATENA 2D

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

NUMERICAL ANALYSIS OF SCREW ANCHOR FOR CONCRETE

Anti-check bolts as means of repair for damaged split ring connections

Cyclic Response of Dowel Connections in Precast Structures

Dowel connections in laminated strand lumber

Design of structural connections for precast concrete buildings

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

Space-frame connection for small-diameter round timber

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad

Double Shear Testing of Bolts

Umbrella Inserts and Stubby Screens

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

Moment Resisting Connections for Load Bearing Walls

SEISMIC BEHAVIOR OF BEAM-TO-COLUMN DOWEL CONNECTIONS: NUMERICAL ANALYSIS VS EXPERIMENTAL TEST

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

STRUCTURAL ATTACHMENTS

Module 10 : Improvement of rock mass responses. Content

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

Index Terms: Lathe waste concrete; Shear and bending; Shear strength; Stirrups; Simply supported beams.

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

Umbrella Inserts and Stubby Screens

Glued laminated timber beams repair.

Special Provision No. 904S14 October OPSS 904, January 1995, Construction Specification for Concrete Structures, is amended as follows:

Connection and Tension Member Design

SEA SELF DRILLING, THREADED, HOLLOW BAR / GROUT-ABLE SOIL NAILS / ANCHORS

Material measures of length for general use

Cyclic tests of engineered shear walls with different bottom plate and anchor bolt washer sizes (Phase II)

K L Rakshith, Smitha, International Journal of Advance Research, Ideas and Innovations in Technology.

PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD

Title. CitationJournal of Wood Science, 58(4): Issue Date Doc URL. Rights. Type. File Information.

DTFACT 16 C IN PAVEMENT LIGHT FIXTURE TESTING AND ANALYSIS FINAL SUMMARY PRESENTATION

Module 2 WAVE PROPAGATION (Lectures 7 to 9)

European Technical Assessment ETA-13/0029 of 11/07/2017

Experimental investigation of the behaviour of pinned beam to column connections to pure shear monotonic and cyclic excitation

Shear force transmission in expansion joints

Effect of shoulders on bending moment capacity of round mortise and tenon joints

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

PRO LIGNO Vol. 11 N pp

EXPERIMENTAL INVESTIGATION OF FATIGUE BEHAVIOUR IN COMPOSITE BOLTED JOINTS

Powder Actuated Fastening INTRODUCTION

Please do not open this exam until you are told to do so.

Module 3 Selection of Manufacturing Processes

ScienceDirect. Formability of pure titanium sheet in square cup deep drawing

WELDA FASTENING PLATES

Bolts and Set Screws Are they interchangeable?

Finite Element Modeling of Early Stage Self-loosening of Bolted Joints Haoliang Xu 1, a, Lihua Yang 1, b,, Lie Yu 1,2, c

Internal Threads for Thin-Walled Sections

fischer Test Report Fixing Tests for Fastfloor and Hollowcore Units

Comparison of behaviour of laterally loaded round and squared timber bolted joints

Composite Sections. Introduction BETON PRATEGANG TKS Session 10: 2015/4/27

Experimental Study on Pile Groups Settlement and Efficiency in Cohesionless Soil

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

HUS 6 Screw anchor, Redundant fastening

LABORATORY EVALUATION OF CONCRETE-FILLED GFRP DOWELS IN JOINTED CONCRETE PAVEMENTS

Prof. Sudhir Misra, Dept of CE (PI) Prof. Samit Raychaudhari, Dept of CE (Co PI) Dr. KK Bajpai, Dept of CE (Co PI)

Letter of Transmittal/Submittal

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C)

Finite Element Study of Using Concrete Tie Beams to Reduce Differential Settlement Between Footings

HPD Aerated concrete anchor. Approvals / certificates. Basic loading data (for a single anchor)

Experimental Study of Two Way Half Slab Precast Using Triangular Rigid Connection of Precast Concrete Component

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE STRENGTHENING OF RC FRAMES

Initiating Cracks in PCC Pavements. Malcolm K. Lim, PE

Connection and performance of two-way CLT plates

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Development of Wooden Portal Frame Structures with Improved Columns

A New Technique to Determine the Load Transfer Capacity of Resin Anchored Bolts

ScienceDirect. Effect of rubber forming process parameters on micro-patterning of thin metallic plates

Mechanical behavior of fiberglass reinforced timber joints

IN-PLANE STIFFNESS OF TRADITIONAL TIMBER FLOORS STRENGTHENED WITH CLT

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION MANHOLES

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

Hollo Set Drop-In Anchors

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

Evaluation of In-Pavement Light Fixture Designs and Performance

Sliding shear capacities of the Asymmetric Friction Connection

Strain Measurements with the Digital Image Correlation System Vic-2D

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber

Development of a New-Generation Dowel and Screw Combination 2014 International Crosstie and Fastening System Symposium Urbana, IL, USA 3 June 2014

Glass Fiber Reinforced Polymer (GFRP) Dowel Bars - Aslan 600

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings

TECH SHEET PEM - REF / TESTING CLINCH PERFORMANCE. SUBJECT: Testing clinch performance of self-clinching fasteners.

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

SIMULATION AND EXPERIMENTAL WORK OF SINGLE LAP BOLTED JOINT TESTED IN BENDING

Session 8: Load Transfer Restoration. (Dowel Bar Retrofit, Cross-Stitching, and Slot Stitching)

Experimental Study on the Seismic Behavior of Retrofitted Concrete Infill

Erstantie 2, FIN Villähde Tel , Fax

Disclaimer for FAA Research Publication

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2007 EDITION

A NEW MOTION COMPENSATION TECHNIQUE FOR INFRARED STRESS MEASUREMENT USING DIGITAL IMAGE CORRELATION

Special Provision No. 999S29 May 2010

Transcription:

13 th International Brick and Block Masonry Conference Amsterdam, July 4-7, 2004 DOWEL ACTION OF TITANIUM BARS CONNECTING MARBLE FRAGMENTS AT DIFFERENT ANGLES E.Vintzileou 1, E.-E.Toumbakari 2 Abstract Very often, marble elements belonging to ancient monuments, such as those of the classical Greek antiquity, are fragmented in many pieces. In order to be repaired, those fragments need to be connected again. The connection of marble fragments with dowels and bars is the main mechanism for undertaking the applied shear and traction forces. This paper presents the results of tests that were performed to gain evidence concerning the dowel action of titanium bars connecting marble fragments. The parameters investigated were: the diameter of the bars and the angle between a plane perpendicular to the dowel longitudinal axis and the marble surface. In a previous programme the effect of the size of the cover was investigated as well. Main aims of the testing program were to determine the failure mode and to evaluate the dowel shear strength as a function of the angle between dowel and marble surface. Key Words Dowel, marble, titanium, shear Notation d b : D u : τ u : d u : Nominal bar diameter Maximum mobilized shear resistance Shear strength of dowel Shear displacement corresponding to D u 1 Introduction Titanium is quite extensively used in the conservation works of the monuments at the Athens Acropolis. The commercially pure titanium was selected both for its resistance to all types of corrosion and for its physicochemical compatibility with the marble. Threaded titanium bars, installed in drilled holes and connected with the marble by means of a white cement mortar, have been used up to now, to connect pieces of 1 E. Vintzileou, Assoc.Prof.NTUA, elvintz@central.ntua.gr 2 Eleni-Eva Toumbakari, Dr.Eng., YSMA (Office for the Preservation of the Acropolis Monuments), Min.of Culture page 1 1

fractured architectural members. In those applications, in which titanium bars are subjected to tension, the connections are designed in a way to exclude failure of the connected marble pieces. The relevant design method (Zambas 1988, Zambas 1992) is supported by experimental evidence. There are, however, numerous applications, in which the marble to titanium connection is subjected to shear. For this type of loading, neither experimental evidence nor a design method was, until recently, available. As a first step, in order to provide relevant experimental evidence, an experimental program was carried out at the Laboratory of Reinforced Concrete, NTUA. Threaded titanium bars were installed in drilled holes in Dionysos marble and they were subjected to shear up to failure. Various parameters were investigated, namely the diameter of the titanium bars, their cover and the direction of loading (against the strong or the weak direction of marble s anisotropy) (Vintzileou and Papadopoulos 2001). In this research, the longitudinal axis of the titanium dowels was always perpendicular to the marble surface. However, an angle of 90 between dowel and marble represents only one of the many possibilities that may occur in praxis. Indeed, as in case of the multi-fragmented beams (architraves) of the western part of the Parthenon, the fragments may have various angles or, it might be impossible to insert dowels with a direction perpendicular to each fractured surface (Figure 1). It became necessary to study the effect of the angle between a dowel and a marble surface. In this paper, the main experimental findings of this program are presented and commented. In a future work, formulae will be proposed for the calculation of the maximum shear force carried by the titanium to marble connection. Figure 1 Example of multi-fragmented marble element: architrave OE3.3 of the western part (Opisthodomos) of the Parthenon (measured by E.-E. Toumbakari, drawn by E.-E. Toumbakari and A.Kafourou) (Toumbakari 2002) page 2 2

2 Experimental 2.1 Materials 2.1.1 Dionysos marble Pentelic marble is the basic material of the Acropolis monuments. However, since the quarries of Penteli were closed for environmental reasons, marble from Dionysos mountain, near Penteli, is used in restoration works. Dionysos marble was selected because its physical and mechanical properties are similar to those of the remarkably durable Pentelic marble (Zambas 1988). According to tests carried out at the National Technical University of Athens (Vardoulakis and Kourkoulis 1997, Vardoulakis et al 2000), the compressive strength of Dionysos marble is equal to 83 N/mm 2 and 70 N/mm 2 in its strong and weak direction respectively. Its strength in direct tension is equal to 8.7 N/mm 2 in the strong direction of the marble. The available data regarding the tensile strength of the marble in its weak direction are not considered to be reliable. The Poisson s ratio is equal to 0.33 in both directions. 2.1.2 Titanium Titanium bars, threaded along their whole length, are used to provide continuity between the fractured pieces of the architectural members. Commercially pure titanium (Grade 2, in accordance with ASTM B348) was selected because of its high resistance to all types of corrosion, as well as for its physical and mechanical properties that render it suitable for joining together pieces of the original marble. In fact, the Poisson s ratio of titanium (=0.32) is practically equal to that of the marble. In addition, titanium exhibits a low coefficient of thermal expansion (=9x10-6 grad -1 ), sufficient (but not excessively high) mechanical strength and high elongation at failure (20% 22%). The yield strength of titanium is equal to 300 N/mm 2, whereas its tensile strength is equal to 420 N/mm 2. 2.1.3 Cement mortar As mentioned previously, titanium bars are inserted into drilled holes and connected to the marble by means of white cement mortar. To this purpose, white Portland cement is used. The mechanical properties of the mortar were measured on conventional 40x40x160 [mm] specimens. Its mean compressive strength at 28 days was equal to 12.1 N/mm 2, whereas its tensile strength (in flexure) was equal to 0.96 N/mm 2. 2.2 Experimental procedures 2.2.1 The specimen Eight pieces of Dionysos marble were used for testing in the strong direction of the marble. All pieces were free of macroscopic discontinuities and imperfections. The cross section of the marble pieces was initially rectangular, with dimensions ranging from 23 x 25 cm 2 to 28 x 30 cm 2. On the one side of the rectangle, a triangular piece of marble was cut, to materialize a surface inclined in relation to the dowel (Figure 2). Three inclination values were selected: 30, 45 and 60. This value expresses the angle between a plane perpendicular to the dowel longitudinal axis and the marble surface. At the edge between the horizontal upper surface and the inclined one, holes were drilled to the marble, to accommodate titanium dowels (Figure 3). The diameter of holes was by 4mm larger than the diameter of the dowel. The distance of consecutive holes was large enough to avoid overlapping of marble cones in case of cone failure. The depth of holes was equal to 10 times the dowel diameter. The holes were cleaned from dust before the insertion of titanium dowels. page 3 3

MTS actuator (C) steel plate (B) steel ring (A) LVDT (E) Loading axis LVDT (E) dowel LVDT (E) steel tube (D) steel frame marble element steel frame strong floor Triangular marble piece cut off to materialize marble inclined surface Figure 2 Test arrangement Threaded titanium bars with a diameter of 8mm, 12mm or 16mm were used to form the dowels. Each piece was of a length equal to 10 times the bar diameter (equal to their embedment length) plus 100mm (equal to their protruding length). Cement mortar was poured into each hole and the respective dowel was pushed-in by hand. All tests were carried out more than 28 days after the application of dowels, to allow for sufficient hardening and strength gaining of the mortar. Figure 3 Marble specimen during testing. On the right, the angle between the marble surface and the dowel (which is inside the rigid slab) is visible. page 4 4

2.2.2 Experimental setup Figure 2 also shows the set up used for testing the dowels: The specimen was placed horizontally on the strong floor of the Laboratory. A steel ring (A) was surrounding the dowel under testing. Subsequently, a steel plate (B), having a hole of diameter by 2mm larger than the external diameter of the ring was placed on the specimen. Gradually increasing displacements were applied by an MTS hydraulic actuator (C), with maximum capacity of 500 KN, to the steel plate. The longitudinal axis of the actuator coincided with the surface of the marble element, to avoid eccentric loading of the dowels. The reaction was transmitted to one of the strong steel frames of the Laboratory by means of two horizontal steel tubes (D). The distance of the two tubes was large enough to avoid any parasitic loading of the marble at the vicinity of the dowel under testing. Three LVDTs (E) were used to record displacements of the steel plate and of the marble element during testing. 3 Results and discussion 3.1 Failure mode In the first part of the experimental program (Vintzileou and Papadopoulos 2001) two failure modes were observed, depending on the cover of the dowels, as well as on the direction of loading. Both failure modes are schematically shown in Figure 4: Failure mode I consists in fracture of the dowel at the surface of the marble element, accompanied by limited in depth spalling of the marble. Failure mode consists in the separation of a cone of marble. The angle of separation was approximately equal to 23, whereas the depth of the cone was almost equal to 2c (c being the cover of the dowel). It was observed that failure mode I occurred to all dowels to which a cover equal to 6 times the bar diameter was provided. The same failure mode was observed also for a cover equal to 4 times the bar diameter, when the dowels were loaded against the strong direction of the marble. On the contrary, a cover equal to twice the dowel diameter led to a cone failure. The same holds true for dowels with a cover of 4 times the bar diameter, loaded against the weak direction of the marble. In the present experimental program, care was taken to provide a cover equal or bigger than 6 times the bar diameter (in this case, the cover represents the length of the inclined surface). Nevertheless, it was observed that all failures belonged to mode. There was however a differentiation related to the angle of inclination and to the diameter of the titanium bar. When the diameters are small (8mm and 12mm for all angles) or for small angles (30 for all diameters) failure mode was accompanied with simultaneous failure of the dowel (Figure 5a). At bigger diameters (16mm) and steeper angles (45 but mostly 60 ) failure mode occurred sometimes without failure of the dowel, which, of course, was substantially deformed (Figure 5b). Failure mode I Failure c ~23 mode ~2c Figure 4 Modes of failure (schematic) page 5 5

(a) (b) Figure 5 (a) Example of failure mode with simultaneous failure of the dowel (D=12mm, inclination 45 ) and (b) example of failure mode without failure of the dowel (D=16mm, inclination 60 ) 3.2 Shear force-shear displacement curves In Figure 6, some shear force vs. shear displacement curves are presented. In the previous research, in which the dowels were always perpendicular to the marble surface, it was observed that, independently of the failure mode that occurred, there was a practically linear relationship between shear force and shear displacement up to approximately 80% of the maximum mobilized shear force. Then, a less steep curve followed up to failure. This is not, however, the case in the present research. As an example, the behavior of dowels with a diameter of 12mm is discussed. shear force [kn] 30 25 20 15 D=12mm, 30deg -1 D=12mm, 30deg -3 D=12mm, 30deg -4 D=12mm, 45deg -4 D=12mm, 45deg -5 D=12mm, 45deg -6 D=12mm, 60deg -1 D=12mm, 60deg -2 D=12mm, 60deg -4 D=12mm, 60deg -5 10 5 0 0 2 4 6 8 10 12 14 16 18 20 shear displacement [mm] Figure 6 Shear force vs. shear displacement curves of the dowels with diameter 12mm at different angles page 6 6

There is a clear grouping of the curves as a function of the angle of the marble surface. Expectedly, the steeper curves correspond to the smaller angle (30 ). Then, an angle increase brings about a bigger inclination of the shear force shear displacement curves. The very big deformations of the curves corresponding to a marble angle of 60 represent the deformations to which the dowels were subjected before failure (or before the test was stopped). In several cases, an initial part of the curve was recorded, for which shear displacement was increasing without substantial increase of the mobilized shear resistance. This feature is attributed to the fact that this initial part of loading is governed by the characteristics of the cement mortar that lies between the dowel and the marble, which is much softer and less strong than the marble. 3.3 Results In Table 1 the main test results are summarized and are compared with the relevant test results of Vintzileou and Papadopoulos (2001), obtained for titanium dowels perpendicular to the marble surface. Table 1 Main test results d b Angle [deg] Specimen No 8 0 10 11 12 30 1 2 3 45 VI1 VI2 VI3 12 0 22 23 24 D u [kn] τ u [MPa] average τ u [MPa] 9.94 198.8 9.94 198.8 12.21 244.2 9.90 10.00 10.00 7.85 7.30 8.75 198.00 200.00 200.00 157.00 146.00 175.00 d u [mm] 213.90 4.77 8.59 3.73 199.33 n.a.** n.a. n.a. 159.33 15.22 12.37 18.31 Failure mode I* 60 I1 7.00 140.00 (140.00) n.a. 22.89 202.57 204.16 8.91 I* 23.39 206.99 8.24 22.93 202.92 5.75 30 F12IV1 F12IV3 IV4F12 IV5 45 F12VI4 F12VI5 F12VI6 60 F12V1 F12V2 F12V4 F12V5 25.55 23.80 26.20 24.65 21.35 20.80 21.65 12.65 11.75 12.30 12.65 226.11 210.62 231.86 218.14 188.94 184.07 191.59 111.95 103.98 108.85 111.95 221.68 5.46 5.23 6.18 23.94 188.20 11.69 4.26 11.16 109.18 14.63 33.10 7.62 19.40 16 0 not tested I* 30 I3 42.05 209.20 214.05 n.a. I4 44.00 218.91 n.a. 45 F16VI1 F16VI2 F16VI3 33.60 34.05 33.80 167.16 169.40 168.16 168.24 6.87 23.16 6.87 60 F16V2 F16V3 F16V4 24.40 22.70 28.80 121.39 112.94 143.28 * Results obtained from Vintzileou and Papadopoulos (2001) ** Not reliable recording 125.87 29.37 22.82 35.69 page 7 7

It may also be observed that the values of shear displacement at failure are very scattered. In some cases, the failure was very sudden and, thus, the displacement at failure was not reliably recorded. 4 Conclusions Regarding the dowel action of titanium bars connecting marble fragments at different angles, the following conclusions can be drawn: 1. When the angle between the dowel and the marble surface is different than 90, a cone failure is always taking place. 2. The maximum mobilized shear resistance is substantially affected by the angle between the dowel and the marble surface. At very steep angles it may even drop to the half of the shear resistance corresponding to a dowel perpendicular to a marble surface. Acknowledgments The materials needed for testing (Dionysos marble and titanium bars) were offered by the Committee for Conservation of the Acropolis Monuments. The second author wishes to thank Mr N.Toganidis, head of the Parthenon restoration works, for his permission to carry out the tests at the NTUA. References Zambas, C., 1988, Principles for the structural restoration of the Acropolis monuments, Proc. Intern.Conf. on The Engineering Geology of Ancient Works, Monuments and Historical Sites, (Edited by P.Marinos and G.C.Koukis), Balkema, Rotterdam, 1813-1818. Zambas, C., 1992, Structural repairs to the monuments of the Acropolis-The Parthenon, Proceedings of the Institution of Civil Engineers, 166-176. Toumbakari E.-E., 2002, Repair and strengthening of the architectural members of the Opisthodomos of the Parthenon, Proc. 5 th Intern.Meeting for the Restoration of the Acropolis Monuments, Athens 2002 (in press). Vardoulakis, I. Kourkoulis, S.K., Mechanical properties of Dionysos marble, Final Report of the Environment Project EV5V-CT93-0300 Monuments under seismic action, Nat. Tech. Univ. of Athens, Athens. Vardoulakis, I., Stavropoulou, M., Papadopoulos, Ch., 2000, Direct tension tests on Dionysos marble, EU DG X SMT Programme No SMT4-CT96-2130, Final Report Vintzileou, E., 1999, Shear transfer by dowel action and friction as related to size effects, CEB Bulletin No 237, Concrete tension and size effects, 53-77. 9Vintzileou E., Papadopoulos K., 2001, Dowel action of titanium bars connecting marble elements, Proceedings of the International RILEM Symposium «Connections between steel and concrete, Ed. R.Eligehausen, Vol. 2, 899-908. page 8 8