This is a refereed journal and all articles are professionally screened and reviewed. Electromechanical Active Filter as a Novel Custom Power device

Similar documents
We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

UPQC CONTROL BASED ON MO-ADALINE APPROACH

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

MODELING AND SIMULATION OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT

A Modified Control Method For A Dual Unified Power Quality Conditioner

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

Downloaded from

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Key-Words: - NARX Neural Network; Nonlinear Loads; Shunt Active Power Filter; Instantaneous Reactive Power Algorithm

2020 P a g e. Figure.2: Line diagram of series active power filter.

Power Quality improvement of a three phase four wire system using UPQC

Power Quality Improvement in Fourteen Bus System using UPQC

LOAD REACTIVE POWER COMPENSATION BY USING SERIES INVERTER OF UPQC

Multiconverter Unified Power-Quality Conditioning System: MC-UPQC T.Charan Singh, L.Kishore, T.Sripal Reddy

Power Quality Improvement by Simultaneous Controlling of Active and Reactive Powers in UPQC-S

Literature Review for Shunt Active Power Filters

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

Mitigation of Voltage Sag/Swell Using UPQC

Improvement of Power Quality Using a Hybrid Interline UPQC

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

Modeling and Analysis of a Nonlinear Adaptive Filter Control for Interline Unified Power Quality Conditioner

B.Tech Academic Projects EEE (Simulation)

CONTROL OF VOLTAGE SAG/SWELL IN THREE PHASE DISTRIBUTION LINE

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

Performance Analysis of UPQC for Non-Linear Load by Using MATLAB

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Review on Shunt Active Power Filter for Three Phase Four Wire System

UPQC for Improvement Power Quality.

Control of Power Flow with Multi Bus Three-Feeder Distribution System using GUPQC

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

p. 1 p. 6 p. 22 p. 46 p. 58

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

A Voltage Controlled DSTATCOM using Hybrid Renewable Energy DC Link VSI for Power Quality Improvement

Compensation for Voltage and Current in Multifeeder System Using MC-UPQC

Application of Fuzzy Logic Controller in Shunt Active Power Filter

A Novel Approach to Simultaneous Voltage Sag/Swell and Load Reactive Power Compensations Using UPQC

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Enhancement of Power Quality in Multi Feeders by using MC-DPFC

Enhancement of Power Quality Using Advanced Series Active Power Filters

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

A Power Control Scheme for UPQC for Power Quality Improvement

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

UPQC with Islanding and Grid Connection for Microgrid Applications

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

WITH THE advent of advanced power-electronics technologies,

Power Quality Improvement in Distribution System Using D-STATCOM

UPQC (Unified Power Quality Conditioner)

SIMULATION OF D-STATCOM IN POWER SYSTEM

Fuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics Reduction

Analysis & Function of Unified Power Quality Conditioner for Power Quality Improvement of Distributed Network

Design of Unified Power Quality Conditioner (UPQC) Connected To Three Phase Four Wire System

P.CHAITHANYAKUMAR, T.VARAPRASAD/

Unified Power Quality Conditioner Based on Neural-Network Controller for Mitigation of Voltage and Current Source Harmonics

A Control Scheme for Dual Unified Power Quality Conditioner to Improve Power Quality

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

Protection from Voltage Sags and Swells by Using FACTS Controller

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

ISSN Vol.03,Issue.07, August-2015, Pages:

Modeling and Analysis of DPFC to Improve Power Quality

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Design and Control of Interline Unified Power Quality Conditioner for Power Quality Disturbances

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

Control of grid connected inverter system for sinusoidal current injection with improved performance

POWER QUALITY ASSESSMENT AND ENHANCEMENT IN A GRID CONNECTED RENEWABLE ENERGY SYSTEM USING DYNAMIC VOLTAGE RESTORER

FUZZY LOGIC CONTROLLER BASED UPQC FOR POWER QUALITY MITIGATION IN GRID CONNECTED WIND ENERGY CONVERSION SYSTEM

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Power Quality Improvement using Shunt Passive Filter

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Mitigation of Voltage Sag and Swell Using Dynamic Voltage Restorer

DESIGN A D STATCOM FOR VOLTAGE HARMONIC SUPPRESSION IN DISTRIBUTION SYSTEM

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Improvement of Power Quality Using a Hybrid UPQC with Distributed Generator

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

STATCOM BASED ON REDUCTION OF PQ ISSUES IN MICRO GRID APPLICATION SYSTEMS

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Design and Simulation of Active Power and Power Angle Control of UPQC to Mitigate Voltage Sag/Swell and Load Reactive Power Compensation

PERFORMANCE OF DISTRIBUTION STATIC COMPENSATOR IN LOW VOLTAGE DISTRIBUTION SYSTEM

ANALYSING THE EFFECT OF USSC CONNECTION TO DISTRIBUTION SYSTEM ON VOLTAGE FLICKER

A Time Domain Reference-Algorithm for Shunt Active Power Filters

A Review on Improvement of Power Quality using D-STATCOM

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Transcription:

Advances in Environmental Biology, 7(3): 445-457, 3 ISSN 995-756 445 This is a refereed journal and all articles are professionally screened and reviewed ORIGINAL ARTICLE Electromechanical Active Filter as a Novel Custom Power device A. Mokhtarpour, H.A. Shayanfar, M. Bathaee Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran A. Mokhtarpour, H.A. Shayanfar, M. Bathaee; Electromechanical Active Filter as a Novel Custom Power device ABSTRACT In this paper electromechanical active filter which can be used as parallel compensator in power quality compensation area has been introduced theoretically. Algorithm and mathematical relations for the control of small synchronous generator as an electromechanical active filter have been presented, too. Power quality compensation in sag, swell, unbalance, and harmonized conditions have been done by use of introduced active filter with integration of Unified Power Quality Conditioner (UPQC). In this research, voltage problems are compensated by the Series Active Filter (SAF) of the UPQC. On the other hand, issues related to the compensation of current problems are done by the electromechanical active filter and the Parallel Active Filter (PAF) of UPQC. Main principle of the control approach is based on moving average window Fourier transform theory. For validation of the proposed theory in power quality compensation, a simulation has been done in MATLAB/SIMULINK and a number of selected simulation results have been shown. Key words: Synchronous generator, UPQC, Power Quality. Introduction One of the serious problems in electrical power systems is the increase of electronic devices which are used by the industry as well as residences. These devices, which need high-quality energy to work properly, at the same time, are the most responsible ones for decreasing of power quality by themselves. In the last decade, Distributed Generation systems (DGs) which use Clean Energy Sources (CESs) such as wind power, photo voltaic, fuel cells, and acid batteries have integrated at distribution networks increasingly. They can affect in stability, voltage regulation and power quality of the network as an electric device connected to the power system. One of the most efficient systems to solve power quality problems is Unified Power Quality Conditioner (UPQC). It consists of a Parallel-Active Filter (PAF) and a Series-Active Filter (SAF) together with a common dc link [-6]. This combination allows a simultaneous compensation for source side currents and delivered voltage to the load. In this way, operation of the UPQC isolates the utility from current quality problems of load and at voltage quality problems of utility. Obviously, modern power systems need high reliability of supplied energy. Nowadays, small synchronous generators, as DG source, which are installed near the load can be used for increase reliability and decrease losses. Scope of this research is integration of UPQC and mentioned synchronous generators for power quality compensation and reliability increase. In this research small synchronous generator which will be as electromechanical active filter, not only can be used as another power source for load supply but also, can be used for the power quality compensation. Main principle of the proposed theory for extraction of reference signals is based on the variable window Fourier transforms. A T-type active power filter for power factor correction is proposed in [7]. In [8], neutral current in three phase four wire systems is compensated by using a four leg PAF for the UPQC. In [9], UPQC is controlled by H approach which needs high calculation demand. In [], UPQC can be controlled based on phase angle control for share load reactive power between SAF and PAF. In [] minimum active power injection has been used for SAF in a UPQC-Q, based on its voltage magnitude and phase angle the same time isolates the load from the Corresponding Author A. Mokhtarpour, Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran E-mail: a.mokhtarpour@gmail.com

ratings in sag conditions. In [], UPQC control has been done in parallel and islanding modes in dqo frame use of a high pass filter. In [3-5] two new combinations of SAF and PAF for two independent distribution feeders power quality compensation have been proposed. Section generally introduces UPQC and main relations of voltage and current signals. Section 3 explains generally proposed control strategy. Section 4 introduces electromechanical active filter. Section 5 explains control of Electromechanical Active Filter and used algorithm of the variable window Fourier transforms for extraction of the reference signals in detail. Also, in this section used implemented model of the electromechanical active filter in the paper, has been shown. Section 6 simulates the paper. Finally, section 7 concludes the results. 446 Unified Power Quality Conditioner (UPQC): UPQC has composed of two inverters that are connected back to back []. One of them is connected to the grid via a parallel transformer and can compensate the current problems (PAF). Another one is connected to the grid via a series transformer and can compensate the voltage problems (SAF). These inverters are controlled for the compensation of the power quality problems instantaneously. Fig. shows the general schematic of a UPQC. A simple circuit model of the UPQC is shown in Fig.. Series active filter has been modeled as the voltage source and parallel active filter has been modeled as the current source. Fig. : General schematic of a UPQC. Fig. : Circuit model of UPQC. Proposed Configuration: Fig. 3, shows schematic of the proposed compensator system. As mentioned earlier the main principle of the proposed control system is based on the Fourier transforms. Required components of source side voltage and load side current can be extracted by the moving average window Fourier transforms. It is known that for obtaining the satisfied response from Fourier transform at least one cycle data is need. So, in the proposed control system there is a data window with the length of the main period of power system which is moved to the right by new data interring for the extraction of Fourier transforms. This is because of mathematical calculation reduction. In this paper, for SAF control, first order component of source voltage has been determined as reference voltage. Also, for PAF control, sum of current harmonics with

higher order than 7, has been determined as PAF compensator signal. But, load current 447 harmonics with lower order than 7 and reactive power have been compensated by the proposed filter. Fig. 3: Proposed compensator system. Electromechanical Parallel Active Filter: Fig. 4 shows the simple structure of a synchronous generator. Based on Eq. (), a DC field current of i f produces a constant magnitude flux. N, f if N, f N si F f f N f if f s Mi R R f () Where, N f and N s are effective turns of the field windings and the stator windings, respectively; F f is the magnetomotive force; R is the reluctance of the flux line direction and M is the mutual induction between rotor and stator windings [6]. Speed of rotor is equal to the synchronous speed ( n f s ). p Thus, the flux rotates with the angular speed n of s s. So, stator windings passing 6 flux has been changed as Eq. (). It is assumed that in t, direct axis of field and stator first phase windings conform each other. s() t if M cos( t) () The scope of this section is theoretically investigation of a synchronous machine as a rotating active filter. This theory will be investigated in the static state for a circular rotor type synchronous generator that its equivalent circuit has been shown in Fig. 5. Where, X s is the synchronous reactance of the generator [6]. Fig. 4:

448 Fig. 5: Equivalent circuit. Eq. (3) shows the relation between magnetic flux and voltage behind synchronous reactance of the generator. d () d( if M cos( t)) d( if cos( t)) s t e M (3) dt dt dt Based on Eq. (3), if the field current be a DC current, the stator induction voltage will be a sinusoidal voltage by the amplitude of M i f. But, if the field current be harmonized as Eq. (4) then, the flux and internal induction voltage will be as Eqs. (5) and (6), respectively. if Idc Ifn sin( nt fn) (4) n f if M cos( t) [ Idc Ifn sin( nt fn)] M cos( t) n (5) MIdc cos( t ) M I fn[sin(( n ) t fn ) sin(( n ) t fn )] n eo [ MIdcsin( t) MIf cos( t f )] (6) [ MI f ( n _) ncos( nt f ( n) ) MI f ( n) ncos( nt f ( n) )] n Eq. (6) shows that each component of the generator output voltage has composed of two components of the field current. This problem has been shown in Fig. 6. Fig. 6: Relation of the field current components by the stator voltage components. It seems that a synchronous generator can be assumed as the Current Controlled System (CCS). Thus it can be used for the current harmonic compensation of a nonlinear load ( I hn ) as parallel active filter. Algorithm of reference extraction: From Fig. 5, relation between terminal voltage of the generator and I hn can be derived as Eq. (7).

449 eo V PCC Z nihn V n sin( nt n) (7) n Where, n is the harmonic order; Z n R jnx is the harmonic impedance of the synchronous generator and connector transformer which are known, V PCC is the point of common coupling voltage and I hn is the compensator current that has been extracted from the control circuit. If similar frequency components of voltage signal e o in Eq. (6) and e o in Eq. (7) set equal, the magnitude and phase angle of the related field current components will be extracted as: For n=: MIdc sin( t) MI f cos( t f ) V sin( t ) (8) [ MI dc MI f sin f ] [ MI f cos f ] V (9) MI f cos f tan [ ] MI dc MI f sin f () For simplicity equations (9) and () can be rewritten as follows: X MIdc MIf sinf () Y MIf cosf () X Y V (3) Y X (4) From the above equations, magnitude and phase of the second component of filed current can result in: X V (5) tan X MIdc tanf X tan (6) ( X MIdc) I f M sinf (7) For n : X MIf ( n) nsinf ( n) MIf ( n) nsinf ( n) (8) Y MIf ( n) ncosf ( n) MIf ( n) ncosf ( n) (9) X V n () tan n X.5MnIf ( n) sinf ( n) tanf ( n) X tann.5mnif ( n) cosf ( n) () ( X.5MnIf ( n) sin f ( n) ) I f ( n) Mnsin () f ( n) Where, M and are the mutual inductance and angular frequency, respectively. Obviously for the extraction of required components of filed current from the above equations, first suggestion for DC and first order component of the field current are need. Resulted field current can be injected via a PWM and current inverter to the field windings of the synchronous generator. Fig. 7 shows the model used for the electromechanical active filter. Field circuit can be modeled by the impedance of Z f in series with a controlled voltage source which shows induction voltage in the rotor side. k is determined as stator to rotor windings turn ratio. I h and I f are desired compensator current and calculated field current signal. Z ( Rs RT ) j( X s X T ) which, subscript s returns to the synchronous machine and subscript T returns to the connection transformer.

Detail of the proposed control circuit can be found in the equations () to (). In the present research controlled voltage source of MATLAB has been used instead of required PWM and inverter. Constant and integrator coefficients in the PI controller have been chosen and, respectively. As mentioned earlier first order load active and reactive powers can be easily attended in the 45 electromechanically compensated share of load current for decrease of SAF and PAF power range of UPQC. This problem can control power flow as well as power quality. In other word it can be possible to use a synchronous generator not only for first order voltage generation but, also for the harmonic compensation too. Fig. 7: Block diagram of the proposed active filter control. Fig. 8: General test system circuit.

Simulation: For the investigation of the validity of the mentioned control strategy for power quality compensation of a distribution system, simulation of the test circuit of Fig. 8 has been done in MATLAB software. Source current and load voltage, have been measured and analyzed in the proposed control system for the determination of the compensator signals of SAF, PAF and filed current of the electromechanical active filter. Related equations of the controlled system and proposed model of the electromechanical active filter as a current controlled source have been compiled in MATLAB software via M-file. In mentioned control strategy, voltage harmonics have been compensated by SAF of the UPQC and current harmonics with higher order than 7, have been compensated by PAF. But, the total of load reactive power, 5 percent of load active power 45 and load current harmonics with lower order than 7 have been compensated by the proposed CCS. This power system consists of a harmonized and unbalanced three phase 38V (RMS, L-L), 5 Hz utility, a three phase balanced R-L load and a three phase rectifier as a nonlinear load. For the investigation of the voltage harmonic condition, utility voltages have harmonic and negative sequence components between.5 s and. s. Also, for the investigation of the proposed control strategy in unbalance condition, magnitude of the first phase voltage is increased to the.5 pu between.5 s and. s and decreased to the.75 pu between.5 s to. s. Table, shows the utility voltage harmonic and sequence parameters data and Table, shows the load power and voltage parameters. A number of selected simulation results will be showed further. Table : Utility voltage harmonic and sequence parameters data. Voltage Order Sequence Magnitude (pu) Phase Angle (deg) 5. -45 3. Table : Load power and voltage parameters data. Load Nominal Power (kva) Nominal Voltage (RMS, L-L) Linear 38V Non linear 5 38V Fig. 9 shows the source side voltage of phase. Fig. shows the compensator voltage of phase. Fig. shows load side voltage of phase. Fig. shows the load side current of phase. Fig. 3 shows the CCS current of phase that has been supplied by the proposed active filter. Fig. 4 shows the PAF of UPQC current of phase. Fig. 5 shows the source side current of phase. Fig. 6 shows the field current of the proposed harmonic filter. Fig. 7 and 8 show source voltage and load voltage frequency spectrum, respectively. Figs. 9 and show load current and source current frequency spectrum, respectively. Figs. and show CCS and PAF frequency spectrum, respectively. Table 3 shows THDs of source and load voltages and currents. Load voltage and source current harmonics have been compensated satisfactory. 4 3 Voltage (V) - - -3-4..4.6.8...4.6.8. Fig. 9: Source side voltage of phase (swell has been occurred between.5 and. sec and sag has been occurred between.5 and. sec. Also, harmonics of positive and negative sequences have been concluded between.5 to. sec).

45 5 5 Voltage (V) -5 - -5..4.6.8...4.6.8. Fig. : Compensator voltage of phase (compensator voltage has been determined for the sag, swell, negative sequence and harmonics improvement). 4 3 Voltage (V) - - -3-4..4.6.8...4.6.8. Fig. : Load side voltage of phase (sag, swell, harmonics, positive and negative sequences have been canceled). 4 3 Current (A) - - -3-4..4.6.8...4.6.8. Fig. : Load side current of phase (it is harmonized. It should be noticed that this current has been calculated after the voltage compensation and thus voltage unbalance has not been transmitted to the current).

453 5 5 Current (A) -5 - -5 -..4.6.8...4.6.8. Fig. 3: Proposed CCS current of phase (this current has been injected to the grid by the electromechanical active filter. The solid line shows output current of filter and dotted line shows desired current of filter). 4 3 Current (A) - - -3..4.6.8...4.6.8. Fig. 4: PAF of UPQC current of phase (this current has been injected to the grid by the parallel active filter of UPQC). 4 3 Current (A) - - -3-4..4.6.8...4.6.8. Fig. 5: Source side current of phase (harmonics and reactive components of load current have been canceled).

454 4 Current (A) 8 6 4..4.6.8...4.6.8. Fig. 6: Field current of proposed harmonic filter (field current is controlled for the load active, reactive and harmonic current compensation). 35 3 5 Amplitude (V) 5 5 3 4 5 6 7 8 9,,,,3,4 Frequency (Hz) Fig. 7: Source side voltage frequency spectrum. 35 3 5 Amplitude (V) 5 5 Fig. 8: Load side voltage frequency spectrum. 3 4 5 6 7 8 9 3 4 Frequency (Hz)

455 45 4 35 3 Amplitude (A) 5 5 5 Fig. 9: Load side current frequency spectrum. 3 4 5 6 7 8 9 3 4 Frequency (Hz) 35 3 5 Amplitude (A) 5 5 Fig. : Source side current frequency spectrum. 3 4 5 6 7 8 9 3 4 Frequency (Hz) 8 Amplitude (A) 6 4 3 4 5 6 7 8 9 3 4 Frequency (Hz) Fig. : Proposed current controlled system frequency spectrum.

456.4. Amplitude (A).8.6.4. Fig. : Parallel active filter frequency spectrum. 3 4 5 6 7 8 9 3 4 Frequency (Hz) Table 3: Total Harmonic Distortion (THD). Source Voltage THD Load Current THD Load Voltage THD Source Current THD.56.79.. Conclusions: It is known that series and parallel active filters are generally used for power quality compensation in distribution systems. Also, use of small synchronous generators in distributed generated networks can reduce transmitted active and reactive powers from the main source and consequently line losses. In this paper power quality compensation was done by composition of UPQC and synchronous generators as electromechanical active filter. In other word, by proper determination and control of synchronous generator field current it could be used as controlled current source for power quality compensation. This was for reduction of UPQC power rating in the distributed generated networks. Also, an algorithm was investigated for the determination of the reference field current. Proposed CCS modeling was implemented based on the mentioned related algorithm in MATLAB software. Control strategy had three instantaneously stages. Voltage harmonics were compensated by SAF of the UPQC. Current harmonics with higher order than 7 were compensated by PAF of the UPQC. Lower order current harmonics, load reactive power and a part of load active power were compensated by the proposed controlled current source. Total harmonic distortion of load voltage before compensation was.56 which was reduced to almost zero after compensation. Also, total harmonic distortion of the source current before compensation was.79 which was reduced to almost zero after compensation. Source voltage unbalance, reactive component of load current and a part of its active component were compensated, too. In this research the investigation of load change and dynamic states were not included which will be proposed in the future work. References. Fujita, H., H. Akagi, 998. The Unified Power Quality Conditioner: The Integration of Series and Shunt Active Filters, IEEE Transaction on Power Electronics, 3(): 35-3.. Shayanfar, H.A., A. Mokhtarpour,. Management, Control and Automation of Power Quality Improvement, INTECH Book Company, ISBN 978-953-769-X-X, Austria. 3. Hannan, M.A., A. Mohamed, 5. PSCAD/EMTDC Simulation of Unified Series- Shunt Compensator for Power Quality Improvement, IEEE Transaction on Power Delivery, (): 65-656. 4. Shayanfar, H.A., N.M. Tabatabaei, A. Mokhtarpour, 7. Best Control Strategy for Unified Power Quality Conditioner (UPQC) Based on Simulation, in: The IASTED International Conference on Power and Energy Systems (PES 7), Clearwater, Florida, U.S.A., January 3-5: 57-6. 5. Kazemi, A. Mokhtarpour, M. Tarafdar Haque, 6. A New Control Strategy for Unified Power Quality Conditioner (UPQC) in Distribution Systems, in: IEEE International Conference on Power System Technology (POWERCON 6), Chongqing, China, October -6: -5. 6. Shayanfar, H.A., N.M. Tabatabaei, A. Mokhtarpour, 5. Modified Strategy for Unified Power Quality Conditioner (UPQC) Based on Intelligent Devices, in: The Ninth World Multiconference on Systemic,

Cybernetics and Informatics, Orlando, Florida, U.S.A., July -3: 3-7. 7. Han, Y., M.M. Khan, G. Yao, L.D. Zhou, C. Chen, 8. A novel harmonic-free power factor corrector based on T-type APF with adaptive linear neural network (ADALINE) control, Simulation Modeling Practice and Theory, 6: 5-38. 8. Khadkikar, V., A. Chandra, 9. A Novel Structure for Three Phase Four Wire Distribution System Utilizing Unified Power Quality Conditioner (UPQC), IEEE Transactions on Industry Applications, 45(5): 897-9. 9. Kwan, K.H., Y.C. Chu, P.L. So, 9. Model- Based H Control of a Unified Power Quality Conditioner, IEEE Transactions on Industrial Electronics, 56(7): 493-54.. Khadkikar, V., A. Chandra, 8. A New Control Philosophy for a Unified Power Quality Conditioner (UPQC) to Coordinate Load- Reactive Power Demand Between Shunt and Series Inverters, IEEE Transactions on Power Delivery, 3(4): 5-534. 457. Lee, W.C., D.M. Lee, T.K. Lee,. New Control Scheme for a Unified Power Quality Compensator-Q With Minimum Active Power Injection, IEEE Transactions on Power Delivery, 5(): 68-76.. Han, B., B. Bae, H. Kim, S. Baek, 6. Combined Operation of Unified Power-Quality Conditioner with Distributed Generation, IEEE Transaction on Power Delivery, (): 33-338. 3. Mohammadi, H.R., A.Y. Varjani, H. Mokhtari, 9. Multiconverter Unified Power-Quality Conditioning System: MC-UPQC, IEEE Transactions on Power Delivery, 4(3): 679-686. 4. Jindal, A.K., A. Ghosh, A. Joshi, 7. Interline Unified Power Quality Conditioner, IEEE Transactions on Power Delivery, (): 364-37. 5. Mokhtarpour, H.A. Shayanfar, N.M. Tabatabaei, 9. Power Quality Compensation in two Independent Distribution Feeders, International Journal for Knowledge, Science and Technology, (): 98-5. 6. Machowski, J., J. Bialek, J.R. Bumby, 997. Power System Dynamics and Stability, John Wiley and Sons, ISBN. 4795643, 97847956433.