Datasheet - PROTECT-IE-02

Similar documents
Datasheet - ZQ Pull-wire emergency stop switches / ZQ 700

Datasheet - ZQ N

Datasheet - BN 20-RZ. Ordering details. Approval. Global Properties :52:27h. Magnetic reed switch / BN 20.

Operating instructions Fail-safe delay timer AZS About this document. Content

02/11/2015

E-STOP relays, safety gate monitors

02/11/2015

02/11/2015

E-STOP relays, safety gate monitors

Type CP-S, CP-C & CP-A Switch mode

PSR-SCP- 24DC/ESD/5X1/1X2/300

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Installation / Monitoring Technique

02/11/2015

Electronic timer CT-TGD.22

Technical features table for miniature circuit-breakers SH 200 Series

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Safety switches with slotted hole lever

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Electronic timer CT-SDD.22

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Output of three-phase motors at 50 Hz and 400 V

PNOZ X3. } Safety relays. Operating Manual EN-08

P RODUCT C ATALOGUE 1/2002

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

New Products Catalogue 2009 Safety Relays ESR5

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Electronic timer CT-SDE

Power supply CP-D 24/1.3

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Power supply CP-D 12/2.1

Power supply CP-E 24/20.0

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Classification Enclosure rating Contact form Contact material

Acceleration sensors With relay output for limit monitoring Analog / CANopen

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Power supply CP-E 24/0.75

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Components for safety applications Preventa safety modules

Electronic Circuit Breaker ESS1 for System SVS1

02/11/2015

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Components for safety applications

Power supply CP-E 24/2.5

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

02/11/2015

in one housing (3). The light beam is reflected by a reflector (4). The objects are detected by interruption of the light beam.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Switching power supplies CP range, Linear power supplies CP-L range. Content

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-MFS.21

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Thermistor motor protection relays

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Electronic Circuit Breaker ESS1 for System SVS1

Description Basic devices with positive operation contacts

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Three-phase monitoring relay

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Protection components

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Safety relays - PSR-SCP- 24DC/ESD/4X1/

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

FM series position switches

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

PNOZ X2.7P. } Safety relays. Operating Manual EN-19

Electronic timer CT-SDS.22

Three-phase monitoring relays CM-PFE and CM-PFE.2

Transcription:

Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emergency stop devices, interlocking devices and others 2 safety contacts Signalling output for each sensor (monitoring of both circuits of the sensors) (Minor differences between the printed image and the original product may exist!) Ordering details Product type description Protect-IE-02 Article number 1184759 EAN code 4030661322605 Approval Approval USA/CAN Classification Standards EN ISO 13849-1, IEC 61508, EN 60947-5-1 PL up d (STOP 0) Control category up 3 (STOP 0) DC > 60% (STOP 0) CCF > 65 points PFH value 2 x 10-7/h (STOP 1) - notice up to max. 36.500 switching cycles/year SIL up 2 (STOP 0) Mission time 20 Years - notice

Global Properties Product name PROTECT-IE Standards IEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508 Compliance with the Directives (Y/N) Climatic stress EN 60068-2-78 Mounting snaps onto standard DIN rail to EN 60715 Terminal designations IEC/EN 60947-1 Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, ventilated Weight 200 g Start conditions Automatic Start input (Y/N) Feedback circuit (Y/N) Start-up test (Y/N) Automatic reset function (Y/N) Reset with edge detection (Y/N) Pull-in delay - ON delay with automatic start 20 ms Drop-out delay - Drop-out delay in case of emergency stop 20 ms Mechanical data Connection type Cage clamps Cable section - Min. Cable section 0,08 mm² - Max. Cable section 2.5 mm² Pre-wired cable rigid or flexible Detachable terminals (Y/N) Mechanical life 10.000.000 operations Electrical lifetime Derating curve available on request restistance to shock 30 g / 11 ms Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm, ± 15 % Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +55 C Storage and transport temperature - Min. Storage and transport temperature 40 C - Max. Storage and transport temperature +85 C Protection class - Protection class-enclosure IP20 - Protection class-terminals IP20 - Protection class-clearance IP20 Air clearances and creepage distances To IEC/EN 60664-1

- Rated impulse withstand voltage Uimp 800 V - Overvoltage category III To VDE 0110 - Degree of pollution 2 To VDE 0110 Electromagnetic compatibility (EMC) EMC rating conforming to EMC Directive Electrical data Rated DC voltage for controls - Min. rated DC voltage for controls 20.4 V - Max. rated DC voltage for controls 28.8 V Rated AC voltage for controls, 50 Hz - Min. rated AC voltage for controls, 50 Hz 20.4 V - Max. rated AC voltage for controls, 50 Hz 26.4 V Rated AC voltage for controls, 60 Hz - Min. rated AC voltage for controls, 60 Hz 20.4 V - Max. rated AC voltage for controls, 60 Hz 26.4 V Contact resistance max. 100 mω Power consumption max. 1.7 W; plus signalling outputs Y1-Y4 Type of actuation DC Rated operating voltage Ue 24 VDC 15% / +20%, residual ripple max. 10% Operating current Ie 0,075 A; plus signalling outputs Y1-Y4 Electronic protection (Y/N) Fuse rating for the operating voltage Internal electronic trip, tripping current > 0,1 A Current and tension on control circuits 24 VDC, 10 ma Inputs Monitored inputs - Short-circuit recognition (Y/N) - Wire breakage detection (Y/N) - Earth connection detection (Y/N) Number of shutters Number of openers Input resistance approx. 2900 Ω at GND or at Ue Input signal "1" 19-28.8 VDC Input signal "0" 0-1 VDC Outputs Stop category 0 Number of safety contacts Number of auxiliary contacts Number of signalling outputs 4 piece Switching capacity - Switching capacity of the safety contacts max. 24 VDC, 2 A ohmic (inductive in case of appropriate protective wiring) - Switching capacity of the signaling/diagnostic outputs Y1-Y4: 24 VDC, 0,1 A Fuse rating - Protection of the safety contacts 2 A slow blow - Fuse rating for the signaling/diagnostic outputs Internal electronic trip, tripping current > 0,5 A Utilisation category To EN 60947-5-1 DC-13: 24 V / 2 A Number of undelayed semi-conductor outputs with signaling

function Number of undelayed outputs with signaling function (with contact) Number of delayed semi-conductor outputs with signaling function. Number of delayed outputs with signalling function (with contact). Number of secure undelayed semi-conductor outputs with signaling function Number of secure, undelayed outputs with signaling function, with contact. Number of secure, delayed semi-conductor outputs with signaling function Number of secure, delayed outputs with signaling function (with contact). 4 piece 1 piece LED switching conditions display LED switching conditions display (Y/N) Number of LED s LED switching conditions display - The integrated LEDs indicate the following operating states. - Position relay K2 - Position relay K3 - Position relay K4 5 piece - LED s or signalling outputs signalise an opened protective device or emergency stops. - Monitoring effected on both contact circuits of the sensor. - Position relay K1 - When the safety guard or the emergency stop circuit is opened, a 24V signal is switched at each output concerned (Y1...Y4) and the assigned LED is lit. - Supply voltage UB Miscellaneous data Applications Emergency-Stop button Pull-wire emergency stop switches Guard system Safety sensor Dimensions Dimensions - Width 48 mm - Height 126 mm - Depth 61 mm notice Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. notice - Wiring example Start level: Depends on the wiring of the safety relay module.

Sensor level: 2-channel control of magnetic safety switches according to EN 60947-5-3 Output level: 2-channel control of a downstream safety relay module The control recognises cross-short, cable break and earth leakages in the monitoring circuit. If the inputs S1, S3, S5 and S7 are not used, they have to be bridged to + If the inputs S2, S4, S6 and S8 are not used, they have to be bridged to - The safety relay modules must be suitable for signal processing for single or dual-channel floating NC-contacts Start and actuator configuration has to be effected in accordance with the data sheet The obtainable control category according to EN 954-1 depends on type and wiring of the used safety relay module Control category 4 to EN 954-1 (when an individual guard door is opened). Control category 3 to EN 954-1 (upon opening of several guard doors simultaneously). The wiring diagram is shown with guard doors closed and in de-energised condition. Keywords Keywords Protect Documents Wiring example (99) 11 kb, 22.08.2008 http://127.0.0.1/bilddata/si_baust/protect-ie/schaltun/kpriel02.pdf Wiring example (99) 19 kb, 25.08.2008 http://127.0.0.1/bilddata/si_baust/protect-ie/schaltun/kpriel01.pdf Images Wiring example Wiring example K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 20.04.2011-18:28:58h Kasbase 1.4.7 DBI