K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

Similar documents
Programmable K-Factor Scaler B and Programming Software Kit B

K-FACTOR SCALER B & B

SSR-150xxx-40VL-12P-xC-xxxCS

Fits Tiger 320 Series UNIVERSAL FREQ/COUNTER INPUT MODULE

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

SSR VL-12P-xC-NCS

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

American Power Design, Inc.

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

K-Factor Scalers. Models B , B , B and B B B B B User Manual. SGN-UM EN-05 (June 2017)

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

TMP-100 Turbine Meter Pulse Divider Circuit

BC145 SIGNAL ISOLATOR BOARD

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

American Power Design, Inc.

2006 MFJ ENTERPRISES, INC.

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

Digital Lighting Systems, Inc.

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

GPS140 DOS Application User s Manual Version 1.0.x

P.O. BOX 1521 POLSON, MT SSR V-12C

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

MFJ-1886TR. Receive Loop Antenna INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment

LUDLUM MODEL 421 AND PMT BASE WITH PREAMPLIFIER/BIAS SUPPLY. October 2014 Serial Number and Succeeding Serial Numbers

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

Pen Multimeter. Model

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

American Power Design, Inc.

Amplified High Speed Photodetectors

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

Preliminary Data Sheet!

Series 3000 Model R-107A

PCO-7114 Laser Diode Driver Module Operation Manual

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

MFJ ENTERPRISES, INC.

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

AMP-13 OPERATOR S MANUAL

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

200Amp AC Clamp Meter + NCV Model MA250

Canoga Traffic Sensing System

TRANSDUCER IN-LINE AMPLIFIER

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

E7000, E7500, and E ma Analog Transmitters

MBC Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

Non-amplified Photodetectors

SC-FI Series Frequency to Current Signal Conditioner

Data Acquisition Modules/ Distributed IO Modules

TABLE OF CONTENTS WARRANTY

AUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc

Warranty Terms & Conditions

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

MS23SL Magnetic Linear Sensor With Smart Limit Switches

Field Hub Installation Guide. P/N Rev. C 05/15

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

Starbox. Installation guide

MODEL DDS8par 48-bit Binary Parallel Controlled Synthesizer

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

SANPERA I. Player`s Handbook

American Power Design, Inc.

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

MFJ ENTERPRISES, INC.

CDT. Service and Installation Manual. Manual Revision Oct 2014

Pen Multimeter. Model

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Non-amplified High Speed Photodetectors

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

OPERATING INSTRUCTIONS

Model 1791 VHF Radio User's Manual

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Operation/Reference Guide NXP-CPI16. NetLinx Custom Panel Interface. Custom Panel Interfaces

1.5µm PbSe Power Detector

M2/M2A AC-DC Power Supply Operator s Manual

Amplified Photodetectors

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Global Water Instrumentation, Inc.

MODEL TI196 Current Loop Meter Installation and Operation Instructions

AMP-12 OPERATOR S MANUAL

Classic Series Public Address Amplifiers C10 & C20 Models

Broadband Step-Up Transformer. User Manual

MFJ ENTERPRISES, INC.

HydroLynx Systems, Inc.

American Power Design, Inc.

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

TARGETuner Antenna Management System for Screwdriver Antennas

Indoor Contact Input Photosensor

TETRIS 1000 High Impedance Active Probe. Instruction Manual

DM-46 Instruction Manual

MFJ ENTERPRISES, INC.

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

Signal Isolation Module. Instruction Manual SIM

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

Fiber Optic Expansion Interface

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Transcription:

F5140 and Programming Kit F5141 8635 Washington Avenue Racine, WI 53406 USA Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 E-Mail: flo-techsales@racinefed.com www.flo-tech.com

TABLE OF CONTENTS Introduction...3 Operating Principle...3 Specifications...3 Installation...4 Enclosure Mounting... 4 Power...4 Turbine Meter...4 Pulse Output...4 Start-up and Configuration Using Optional Programming Software Kit F5141...5 Software... 5 Setting the K-factor...6 Setting the output pulse width...6 Setting the output level to normally high or normally low...6 Setting the output pulse to use the internal or external pull-up resistor...6 Return Goods Authorization...7 Waste Electrical and Electronic Equipment (WEEE) Directive...7 Statement of Warranty...8 Page 2 Form #FLIT 555 11/10

INTRODUCTION The Flo-tech is a field adjustable frequency divider, which interfaces the output signal from a turbine meter with a magnetic pick-up to the input of a PLC, RTU, CPU data acquisition card, or similar totalizer device. The adjustable frequency divisor, referred to as the K-factor, allows the pulses being sent from a turbine meter to be divided into a recognizable unit that an end device, such as a PLC can count and display. OPERATING PRINCIPLE Fluid moving though a turbine flow meter causes the rotor to rotate in relation to the flow rate. The rotation of the rotor blades cuts through the magnetic field generated by the magnetic pick-up which in turn generates a frequency output signal that is directly proportional to the speed of the rotor. The signal produced is received by the input amplifier, which has an input sensitivity of 30 mv p-p to 30 V p-p. The signal is then sent to an onboard microcontroller, which acts as a divisor with a range of 1 to 999,999,999. The divisor (K-factor) is user adjustable through the optional programming software kit. The microcontroller handles the dividing process by counting the input pulses and comparing it to the programmed K-factor value. Once the count equals this value, an output pulse occurs for a selectable time period and the counting process starts over. In addition, if the K-factor is set to 1, the can be used as a pre-amplifier where the frequency from a low-level turbine meter is proportional to the logic level frequency output needed by a PLC or CPU data acquisition card. This option allows the end device to control the dividing process of the turbine meter output to a recognizable flow rate. SPECIFICATIONS External Power: Input Voltage; 8.5 to 30 Vdc (Diode protected) Maximum Current draw; 18 ma (using internal resistor @ 30 Vdc input) Environmental: Operating Temperature; -22 F (-30 C) to +158 F (+70 C) Inputs: Magnetic Pick-up Input Frequency Range; 0 to 4000 Hz Trigger Sensitivity; 30 mv p-p to 30 V p-p Output Signal: Max. Voltage; 30 Vdc Max Power; 0.25 W Pulse Type (using internal pull-up resistor); VH = Power Input Voltage 0.7 Vdc VL = Less then 0.4 V @ max input power Pulse Type (using external pull-up resistor); VH = Input Voltage to external pull-up resistor VL = [VH /(selected resistor value + 47)] 47 Pulse Length; 150μs, 1ms, 25ms, 100ms, 500ms, 1s, or Auto mode selectable. Output Options: Jumper Configurations Internal Pull-up; 3.6K Ω to device power External Pull-up; Open collector Enclosure: ABS with mounting flanges Form #FLIT 555 11/10 Page 3

INSTALLATION The programmable was designed to provide a field adjustable frequency divider that converts the low level frequency output from a turbine meter into a scaled square wave output signal. Refer to Figure 1 below for the I/O terminal connections. The board connections include Power Input, Turbine Meter Input, and the Pulse Output to a totalizing device. PROGRAMMING PORT INTERNAL 3.6K PULL-UP RESISTOR JUMPER OUTPUT + OUTPUT VIN + VIN 8.5-30 VDC TURBINE PICK-UP 1 2 3 4 5 6 Figure 1 Board Connections Enclosure Mounting The enclosure has four (4) mounting holes for easy mounting. Power The requires 8.5-30 VDC to operateand is protected by a diode. Polarity is shown in Figure 1 above. Turbine Meter The turbine meter connections are non-polarized. Shielded twisted pair wire is recommended for this connection to the turbine meter. Pulse Output Either the internal or external pull-up resistor must be used for the to provide an output pulse. This option is controlled by the onboard jumper. With the jumper installed, the internal pull-up resistor is connected. Internal Pull-up Resistor The internal pull-up resistor allows for simple installation but care must be taken to ensure that the device being connected to by the pulse output can handle voltage levels as high as the supply feeding the K-Factor board. Another important setup consideration when using the internal pull-up resistor is to make sure the output pulse from the K-Factor board can supply enough current for the receiving device to be able to read the pulse. The available current that the K-Factor board can supply to the receiving device can be calculated with the following equation. Available Current = Input Voltage - 0.7 V 3600 Ω + 47 Ω Verify that the receiving device input current requirement is below this value for proper operation. Otherwise, an external pull-up resistor less then 3.6K will have to be used. External Pull-up Resistor Using an external pull-up resistor offers the end user greater flexibility of controlling the output pulse provided by the K-Factor board to the receiving device. Since power sources and receiving devices differ between users, different resistor values may be required by different setups. The external pull-up resistor is connected between the receiving device s input and external power source. This power source would be the maximum input voltage (of the pulse) to the receiving device. Refer to the following equation to help determine the resistor value needed. Page 4 Form #FLIT 555 11/10

R = Supply Voltage I Where: R = Resistor value in Ohms Supply Voltage = External supply voltage connected to the external pull-up resistor I = Input current required by the receiving device in amps After the Resistor value has been calculated, make sure in the following equation, that P is less than or equal to 0.25. P represents the power capability of the output and should not exceed 0.25 Watts. Exceeding this value could damage the K-Factor board. Raising the Resistor value will decrease the available power output. P = ( Supply Voltage ) Supply Voltage R + 47 STARTUP and CONFIGURATION USING OPTIONAL PROGRAMMING SOFTWARE KIT (F5141) The programmable can be factory or user configured through a serial port of a PC by a Windows compatible software utility. A programming adapter is required that interfaces the serial port from the PC to the programming port on the board. To program the, begin with the power turned off and connect the adapter cable to the K-Factor Scaler board. See Figure 2. Then, connect the Serial -to- TTL converter (black box) to the adapter cable. Next, attach the serial extension cable to the Serial-to-TTL converter and connect the opposite end to an available 9-pin serial port of a PC. Lastly, make sure power is being supplied. Power must be supplied to the in order to program. The programming software is divided into two columns as shown in Figure 3. The Program Values column is the information that is to be programmed into the K-Factor board and can be entered by the user. The Board Values column is Read ONLY and indicates the information that the K-Factor board currently contains. The Board Values column will only display the contents of the board after a program, read, or verify function was performed. The proper computer serial port must be selected within the K-Factor Programming software for it to communicate with the board. This is done by going to TOOLS COM PORT, from the menu bar, and selecting the Com Port (1 through 16) that the serial programming cable is connected to on the computer. If the serial port selected is invalid, the software will show the message ERROR- Invalid Com Port when trying to program the board. If the serial port selected is the incorrect port (or if there is a problem with the cable), the software will show the message << No Response>> after trying to program the board. All information under the Program Values column must be entered before the software will allow the board to be programmed. 1 2 3 4 5 6 Figure 2 Interface connection The PROGRAM button programs the K-factor, Pulse Width, and Pulse Output to the K-Factor board. After the program function is complete, the board is automatically read and verified. The K-Factor board will retain these values when disconnected from power and can be re-programmed at any time. Figure 3 Programming software screen Form #FLIT 555 11/10 Page 5

The READ button reads the current information from the K-Factor board and displays it under the Board Values column of the PC software. The VERIFY button performs the same function as the READ button but compares the Board Values to the Program Values and displays an error if the two do not match. Configuring and programming the K-Factor board consists of the following four items: Setting the K-factor (divider) Setting the output pulse width Setting the output level normally high or normally low Setting the pulse to use the internal or external pull-up resistor Setting the K-factor The K-factor is the ratio of input pulses per each output pulse and can be viewed as a divisor. The minimum K-factor can be set to 1 where each input pulse yields an output pulse. The maximum K-factor can be set to 999,999,999 where it would take this many input pulses to yield one output pulse. The K-factor is set by entering it into the Program Values column of the software under K-Factor. The K-factor will be programmed into the board when the Program button is pressed, but note that all values must be entered before programming is allowed by the software. Setting the output pulse width The output pulse width is the length of time the pulse remains active before resetting to its resting state. The K-Factor has a total of six different pulse widths to choose from. Some end devices require that the pulse be a certain length or longer in order for proper detection of each incoming pulse. For these devices, it s important to select a pulse width that is long enough for the end device to recognize. The pulse width option is set by selecting the desired pulse width radio button in the Program Values column of the software. The Pulse Width option will be programmed into the board when the Program button is pressed, but note that all values must be entered before programming is allowed by the software. In addition to six pre-set pulse widths to choose from, another option is also available called "Auto mode. This mode acts in the same manor but does not restrain the output pulse to a specific length. Instead, it varies and is dependent on output frequency. The higher the output frequency, the shorter the pulse width output. The lower the frequency output, the longer the pulse width output. This option turns off the Pulse Output option because it does not apply in this mode. Setting the output level normally high or normally low Most end devices will be unaffected by this setting, but the has the ability to invert the output pulse level. This option is set by selecting the desired pulse output radio button in the Program Values column of the software. The Pulse Output option will be programmed into the board when the Program button is pressed, but note that all values must be entered before programming is allowed by the software. When the Pulse Output option High is selected, the output level is normally low and the duration of the selected pulse width is high. When the Pulse Output option Low is selected, the output level is normally high and the duration of the selected pulse width is low. Setting the output pulse to use the internal or external pull-up resistor Either the internal pull-up resistor or an external resistor must be used for the to provide an output pulse. This option is controlled by the onboard jumper and not by software. With the jumper installed, the internal 3.6K pull-up resistor is connected to the input voltage of the board. With the jumper uninstalled, the internal pull-up resistor is disconnected and an external pull-up resistor and supply voltage is required. Page 6 Form #FLIT 555 11/10

Return Goods Authorization When returning equipment for service, a Returned Goods Authorization (RGA) number must be obtained from our Service Department. Please contact them by phone at 800-433-5263 or 262-639-6770 or by e-mail to flo-techtechhelp@racinefed.com. All returns go to the following address and must include the RGA number on the outside of the box: Flo-tech Division of Racine Federated Inc. 8635 Washington Avenue Racine, WI 53406-3738 USA Attn: RGA # xxx-xxxx Waste Electrical and Electronic Equipment (WEEE) Directive In the European Union, this label indicates that this product should not be disposed of with household waste. It should be deposited at an appropriate facility to enable recovery and recycling. For information on how to recycle this product responsibly in your country, please visit: www.racinefed.com/recycle/ Form #FLIT 555 11/10 Page 7

Flo-tech Division of Racine Federated Inc. Limited Warranty and Disclaimer Flo-tech, Division of Racine Federated Inc. warrants to the end purchaser, for a period of one year from the date of shipment from the factory, that all flow meters manufactured by it are free from defects in materials and workmanship. This warranty does not cover products that have been damaged due to misapplication, abuse, lack of maintenance, or improper installation. Flo-tech s obligation under this warranty is limited to the repair or replacement of a defective product, at no charge to the end purchaser, if the product is inspected by Flo-tech and found to be defective. Repair or replacement is at Flo-tech s discretion. A returned goods authorization (RGA) number must be obtained from Flo-tech before any product may be returned for warranty repair or replacement. The product must be thoroughly cleaned and any process chemicals removed before it will be accepted for return. The purchaser must determine the applicability of the product for its desired use and assumes all risks in connection therewith. Flo-tech assumes no responsibility or liability for any omissions or errors in connection with the use of its products. Flo-tech will under no circumstances be liable for any incidental, consequential, contingent or special damages or loss to any person or property arising out of the failure of any product, component or accessory. All expressed or implied warranties, including the implied warranty of merchantability and the implied warranty of fitness for a particular purpose or application are expressly disclaimed and shall not apply to any products sold or services rendered by Flo-tech. The above warranty supersedes and is in lieu of all other warranties, either expressed or implied and all other obligations or liabilities. No agent or representative has any authority to alter the terms of this warranty in any way. 8635 Washington Avenue Racine, WI 53406-3738 USA flo-tech.com Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 E-Mail: flo-techsales@racinefed.com Materials and specifications subject to change without notice. Flo-tech is a trademark of Racine Federated Inc. WINDOWS is a registered trademark of Microsoft Corp. UL is a registered trademark of Underwriters Laboratories. 2010 Racine Federated Inc. All rights reserved. Printed in USA Form #FLIT 555 11/10