DOCUMENTATION OF INSULATION MEASUREMENTS FOR ELECTRICAL MACHINES

Similar documents
Motor-CAD winding temperature model verification using Finite Element Analysis

Linked Electromagnetic and Thermal Modelling of a Permanent Magnet Motor

Contents. About the Authors. Abbreviations and Symbols

Lifetime Consumption and Degradation Analysis of the Winding Insulation of Electrical Machines

Final Publishable Summary

REQUIRED SKILLS AND KNOWLEDGE UEENEEE104A. Topic and Description NIDA Lesson CARD #

rheostat (about 100 ) multimeter

MiniSKiiP Dual Utilization, PCB Design Recommendations and Test Results

HOT SPOT STUDIES FOR SHEET WOUND TRANSFORMER WINDINGS

ELECTRICAL AND THERMAL MODELING OF JUNCTION BOXES

Chapter 1: DC circuit basics

Single-turn and multi-turn coil domains in 3D COMSOL. All rights reserved.

Units. In the following formulae all lengths are expressed in centimeters. The inductance calculated will be in micro-henries = 10-6 henry.

Application Note Silicon Flow Sensor SFS01

NUMERICAL STUDY ON MIXED CONVECTION AND THERMAL STREAKING IN POWER TRANSFORMER WINDINGS

Siemens Transformer Technology Seminar Insulation & Thermal Design

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

AGN Winding and Bearing Temperature Sensors

NIRMA UNIVERSITY INSTITUTE OF TECHNOLOGY ELECTRICAL ENGINEERING DEPARTMENT EE101: Elements of Electrical Engineering DC CIRCUIT


2.3 PF System. WU Weiyue PF5 PF PF1

Ohm s Law and Electrical Circuits

Loss prophet. Predicting stray losses in power transformers and optimization of tank shielding using FEM

Chapter 1: DC circuit basics

A piece of wire of resistance R is cut into five equal parts. These parts are then connected in

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

Course outline: 121 DC Circuits E104A UEENEEE104A - Solve problems in D.C. circuits

II. Experimental Procedure

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

GOVERNMENT COLLEGE OF ENGINEERING, BARGUR

Poh Seng (PS) Lee, PhD Associate Professor Micro Thermal Systems (MTS) Group Department of Mechanical Engineering National University of Singapore

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Thermal behavior of the new high-current PROFET

CHAPTER 6 FABRICATION OF PROTOTYPE: PERFORMANCE RESULTS AND DISCUSSIONS

Product Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000

DIELECTRIC HEATING IN INSULATING MATERIALS AT HIGH DC AND AC VOLTAGES SUPERIMPOSED BY HIGH FREQUENCY HIGH VOLTAGES

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

CFD STUDY OF NON-GUIDED LAMINAR MIXED CONVECTION OF A HIGH PRANDTL NUMBER FLUID IN A TRANSFORMER WINDING-LIKE GEOMETRY

CHAPTER 3: ELECTRIC CURRENT AND DIRECT CURRENT CIRCUIT

HTS PARTIAL CORE TRANSFORMER- FAULT CURRENT LIMITER

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

5. Transducers Definition and General Concept of Transducer Classification of Transducers

Module 1, Lesson 2 Introduction to electricity. Student. 45 minutes

CFD Simulation on Forced Air Cooled Dry-type Transformers. W. WU ABB Inc. USA

Measurement of the thickness of thin foils and testing of the heat sealing of food and medicinal packaging

Power Supplies. 11/2 Introduction. 4AV Non-Stabilized. Power Supplies

EELE 354 Lab Assignment 4: Voltage Drop in Cables

Therma FM, Ltd. is a Czech producer of wound magnetic cores intended for construction of electrical machines.

Vertex Detector Mechanics

Conservation of energy during the reflection and transmission of microwaves


Numerical Simulation of PCB-Coil-Layouts for Inductive Energy Transfer

CONTENTS 2/ /7 8/9 10/11 12/13 14/15 16/17 18/19 20/21 22/23 24/25 26/27 28/29 30/31 32/ Contact Us 38

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

K Factor Power Transformers

Calibration Department Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain. 0 mm to 600 mm / 0.01 mm 7.

Generator Users Group Annual Conference Core testing, low and high flux, tap. Mladen Sasic, IRIS Power

High Efficient Heat Dissipation on Printed Circuit Boards. Markus Wille, R&D Manager, Schoeller Electronics Systems GmbH

OHM S LAW. Ohm s Law The relationship between potential difference (V) across a resistor of resistance (R) and the current (I) passing through it is

1433 SERIES. High-Accuracy Decade Resistor User and Service Manual

Magnetic Micro Testing System Microservo MMT Series C225-E014A

Life Prediction of Mold Transformer for Urban Rail

-Vivaldi. Innovative strip centre measurement in high temperature ranges

RTD-6M PD SENSOR BOARD

Development of an Indirect Resistance Brazing Technology for Sandwich Metal Panels

Resistance and Ohm s law

Picture perfect. Electromagnetic simulations of transformers

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Transformer Technology Seminar What to consider at Design Reviews

Processes for Flexible Electronic Systems

Electromagnetic and thermal model for Brushless PM motors

LABORATORY Experiment 1

Voltage Current and Resistance II

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

Metal Film Resistor Kit

Metal Film Resistor Kit

11. AC-resistances of capacitor and inductors: Reactances.

CURRENT SENSORS REFERENCE DESIGNS Application Note

MAHALAKSHMI ENGINEERING COLLEGE

Essential Thermal Mechanical Concepts Needed in Today s Microwave Circuit Designs. John Coonrod, Nov. 13 th, 2014

Critical Conductor Temperatures in Submarine Cables Equipped with Protection Pipes

Analysis of the dynamic transmission behaviour of piezoelectric film sensors. Andre Zander 1 and Rolf Kumme 2

Keysight Technologies Achieve Accurate Resistance Measurements with the 34980A Multifunction Switch Measure Unit. Application Note

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

A battery of emf 10 V and internal resistance 3 Ω is connected to a resistor. If the current

Episode 108: Resistance

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

ELECTRIC Circuits Test

Reactor and inductor are names used interchangeably for this circuit device.

Power transformers for Network, Rectifiers, Furnace

Glossary of Common Magnetic Terms

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

Contactless Power and Data Transfer for Multiple Nonlinear Loads

Design Guide for High-Speed Controlled Impedance Circuit Boards

Development of A Novel Powder Cluster Wick Structure for LTCC Embedded Heat Pipes

Test description for dry-type transformers chapter for type tests

ESCC2006 European Supply Chain Convention

LOCALIZED LNA COOLING IN VACUUM

Transcription:

FRAUNHOFER INSTITUTE FOR MANUFACTURING TECHNOLOGY AND ADVANCED MATERIALS IFAM DOCUMENTATION OF INSULATION MEASUREMENTS FOR ELECTRICAL MACHINES Processing period: February 2018 September 2018 Michael Gröninger Fraunhofer Institute for Manufacturing Technology and Advanced Materials IFAM in Bremen Offer number: A218102 Purchase number: 3200259751 Project partner:, Mrs Edith Serafini

1 Objective The aim of the project is to verify the work carried out in the previous year on the offer A217279. The estimation of the heat dissipation properties of a new insulation system developed by DuPont (Electronics & Imaging - Interconnect Solutions) in a slot for compared to conventional insulation systems will be verified within this project by means of a measurement setup. The focus is on the determination and comparison of the stationary temperatures of the windings within the slots of a lamination stack with two different slot insulations. 2 12

2 measurement methods for comparability of simulation and measurement In the previous project, the stationary temperatures in the individual winding layers were calculated using the schematic simulation model in Figure 1, which represents the tooth-slot symmetry of the stator of an electric machine representative of the application. Symmetry axis Symmetry axis 4/2 2.4/2 Slot Insulation and air (fitting) distances 1.95 Winding with Insulation and air (fitting) distances 10 Housing (as free and forced convection) Figure 1: Schematic simulation model of the tooth-slot symmetry of an electrical machine Due to the relatively small dimensions of the wires and the slot width, a direct temperature measurement of the windings in the different layers with e.g. embedded or bonded thermocouples is not suitable. Because of their considerable size, these would detect a wrong value in the very limited space within the slot due to a considerable change in the heat path. For this reason, the temperature is determined using an indirect measuring method. The temperature of the conductor can be calculated from the change in the electrical resistance due to a temperature difference. The physical relationship between the temperature-dependent electrical conductivity of a material can be described as follows: In general, the ohmic resistance of a conductor with cross-sectional area A, length l and specific resistance ρ at an initial temperature of 20 C is defined as follows: R 20 = ρ l A = R(T 0) However, the temperature dependence of a physical quantity, including an electrical resistance, is generally not linear. A good approximation of this dependence can be described by a Taylor polynomial of nth degree with the following equation: 3 12

n R( T) = R( T ) (1 + α( T T ) + β( T T ) + γ( T T ) +... + k ( T T ) ) 2 3 0 0 0 0 n 0 where: R -dependent resistor T to be considered T 0 Reference temperature, frequently 20 C α Temperaturcoeffizient 1st degree β Temperaturcoeffizient 2nd degree γ Temperaturcoeffizient 3rd degree k n Temperaturcoeffizient nth degree Due to the temperature range for wires in of insulation class H (200 C), in the following only the first term from the above Taylor polynomial is used to determine resistance. The resulting error compared to the quadratic approximation is approx. 1.2 % at a temperature sweep of 180 K for copper wires and can be assumed to be negligible. With the help of the temperature coefficient α the following expression for the resistance results: RT ( ) = RT ( ) (1 + α( T T)) 0 0 For the determination of resistance, this test setup relies on the method of voltage-correct measurement of ohmic resistances. It is particularly suitable for measurements of very lowimpedance resistors where contact and line resistances can no longer be neglected. Figure 2 illustrates the wiring, which is comparable to a four-wire measurement. Winding section in slot IWinding = I DC I DC IV = 0 V Voltmeter DC-Source Figure 2: Principle circuit for voltage correct measurement of ohmic resistances The resistance value R(T 0) is first determined using a micro-ohmmeter. An adjustable DC-source is connected to the terminals of an ohmic resistor so that the test specimen heats up. The stationary temperature condition of the test specimen is awaited. Afterwards the voltage over the lowimpedance resistor can be measured directly at the terminals using a high-impedance voltage meter. With the help of ohm s law T aaa = R(T) = U/I and R(T) α R(T 0 ) 1 α + T 0 it is possible to calculate the mean temperature of the conductor section in the slot. 4 12

3 Test specimen and measuring setup Description of the test specimen Based on the nomenclature of the previous offer A217279 Table 1 shows the selection of the materials to be tested for the test specimen. All three materials have been provided by DuPont. The mean cross-section geometry including insulation of the wires used for this test is 2.65 mm x 1.71 mm. Since this differs from the geometric dimensions from the simulation work of the previous work, additional simulations have been carried out within this project which takes the real dimensions into account. The results are presented in the following chapter. Table 1: Selection of the wire and insulation materials to be investigated Typ Wire2 SlotA SlotC Type of insulation Winding wire Nomex Paper NKN Laminate Material Film A (Kapton FWN), foil thickness 33 µm, 1 foil with 50 % overlap Thickness of insulation (µm) 66 0.19 Nomex 410 0.18 0.12 Laminate B, (1.5-5-1.5, Kapton MT + Film) 0.22 0.35 Thermal conductivity (W/mK) The schematic simulation model in Figure 1 represents the basis for the construction of a suitable test specimen. It shows a tooth-slot symmetry of the stator of an electrical machine representative of the intended purpose. This two-dimensional model must be converted into a three-dimensional model for a real test setup. In order to obtain a statistical estimation, two sheet packages in the form of linear stators with six identical slots each for the different wire and insulation paper combinations were constructed. Table 2 shows the characteristic values of the two sheet packages. Table 2: Overview of the characteristic values of the two test specimens Lamination material Wire / Slot insulation (see Table 1) Lamination stack 1 Lamination stack 2 M400-50A with bonding varnish insulation C3 (DIN EN 10106) Wire2 - SlotA M400-50A with bonding varnish insulation C3 (DIN EN 10106) Wire2 - SlotC Vacuum impregnation Axalta Voltatex 4250 Axalta Voltatex 4250 Amount of slots 6 6 Slot width/length 3.16 mm / 140 mm 3.24 mm / 140 mm Tooth width/height 8 mm / 16 mm 8 mm / 16 mm Yoke height 10 mm 10 mm Contact surface to cooling plate 140 mm x 140 mm (grounded) 140 mm x 140 mm (grounded) 5 12

In addition to the characteristic data from Table 2, the wires of both lamination stacks are meandered into the slots in series and fixed by a slot closure. In order to realistically increase the thermal connection of the coils to the laminated stack, the coil was impregnated with an epoxy resin according to Table 2 in a vacuum impregnation process. Figure 3 shows the complete setup in different views. Winding section to be measured Figure 3: Lamination stack as test specimen In order to be able to measure the voltages over the winding layers for the measurements (example see Figure 3), the copper has been stripped for a contact surface at the end of the respective end winding section on both sides. Viewed from the slot opening, the 1st, 3rd and 6th winding layer in all slots have been prepared for the voltage measurement. Thus, for each lamination stack there are 18 winding sections for the measurements (Figure 4). Figure 4: Measuring points on the test specimen 6 12

Description of the measurement setup The measuring setup should reproduce the coil with the slot insulations in a water-cooled lamination stack, which is usually to be found in highly utilised. For a comparable thermal connection of the lamination stack, it is mounted horizontally on a watercooled aluminium heat sink with four screw clamps, the teeth pointing upwards. Figure 5 demonstrates the completely installed test specimen in the test environment. Air pistol DC-Connection Screw clamp Test specimen Water connection and heat sink Figure 5: Test specimen in the test environment The air pistols only blow linearly along the two outer teeth in order to protect the outer wires from overheating. A temperature-controlled water circuit is used to cool the lamination stack. The inlet temperature of the cooling water into the heat sink is maintained at 30 C at a flow rate of about 1 l/min. Table 3 lists the devices used for the test. Table 3: List of test bench equipment used Manufacturer Modell Type Purpose of use Keysight 34461 A Digital Multimeter Voltage measurement, calibrated InfraTec VarioCAM HR IR-Camera measurement/monitoring EA Elektro Automatik EA-PSI 9080-120 DC power source DC power source, calibrated TFA Dostmann Digital Thermo- /humidity /humidity meter, Hygrometer meter calibrated Fluke 54 II Thermometer for Digital Thermometer Thermometer countermeasurement Chauvin Measurement of ohmic resistant CA 6240 Mikro-Ohmmeter Arnoux at room temperature 7 12

4 Results of the measurements Thermographic analysis Thermographic images were taken to show the spatial distribution of temperature and to monitor hotspots. An example for a qualitative distribution is shown in Figure 6. Similar to usual electric machines the hot spots are located at the end windings. In addition, it can be seen from this that the winding layers outside the slots along the tooth do not receive sufficient cooling. So an active cooling by the air pistols described in the measurement setup is necessary to protect the conductor. Figure 6: Exemplary thermographic image for qualitative spatially resolved temperature display and monitoring Due to the difference in the setup as described above adapted simulations have been carried out in order to be compared with the measurements. The following modified boundary conditions were assumed for the calculations: 1. Two heat sinks a. Upper side tooth end: α=50-70 W/m²K (temperature-dependent) representative of free convection b. Contact surface to cooling plate: α=2500 W/m²K, representative of forced convection (e.g. water jacket cooling of a housing) 2. To consider the impregnation of the coil a. Each winding layer has a gap of 5 µm to the adjacent winding layer due to the mounting distance which has the thermal properties of air. b. Each winding position has a mounting distance to the adjoining tooth flank of 10 µm, which has the thermal properties of air 3. The DC losses respectively the currents are adjusted so that a temperature level of around 100 C, 150 C and 200 C is obtained. 8 12

Simulation and measurement results Figure 7 shows the simulation results of the winding temperatures of a complete coil at different temperature levels at 23 C ambient temperature, which are achieved by imprinting three different DC currents. An average temperature difference of approx. 13 K (100 C), 22 K (150 C) or 30 K (200 C) is achieved between the two lamination stacks over all winding positions. This indicates an increase in heat dissipation with the combination "Wire2-NutC". Furthermore, as expected, the temperature drops from the middle windings to the two heat sinks. Coil temperature in C 105 100 95 90 85 80 75 70 1 2 3 4 5 6 Layer number Coil temperature in C 160 150 140 130 120 100 1 2 3 4 5 6 Layer number Coil temperature in C 210 190 170 150 130 1 2 3 4 5 6 Layer number Figure 7: Simulation results of the winding temperatures of a complete coil at different temperature levels 9 12

As already illustrated in Figure 4, there are 18 measuring points per test specimen. Only the winding layers of the inner four slots were used for the statistical evaluation, as these have homogeneous boundary conditions. The four measured values of one winding layer were averaged. Figure 8 compares the averaged winding temperatures of the inner four slots of the two lamination stacks at the different temperature levels. The room temperature during the measurements was 24.5 C for measurement of lamination stack 1 (Wire2-NutA) and 22.5 C for lamination stack 2 (Wire2-NutC). In agreement with the simulation results in Figure 7, a temperature gradient from the middle of the slot (winding layer 3) to the outside (winding layer 1 and 6) to the two heat sinks is also shown here in both lamination stacks. 210 190 170 150 130 90 70 level 100 C level 150 C level 200 C 210 190 170 150 130 90 70 level 100 C level 150 C level 200 C Figure 8: Measured coil temperatures of the two lamination stacks at different temperature levels In addition, the lower maximum temperatures of the winding layers with lamination stack 2 (Wire2- NutC) are clearly visible. Figure 9 illustrates the temperature difference of the winding layers of the two lamination stacks. Obviously, the temperature difference increases with a higher temperature level. 50 Difference of the winding layer temperature in C 45 40 35 30 25 20 15 10 5 0 level 100 C level 150 C level 200 C Figure 9: difference of both lamination stacks 10 12

Figure 10 compares the simulation and measurement results for the winding temperatures of the two lamination stacks. For all temperature levels the simulation can confirm the difference between the two setups. 105 100 95 90 85 80 75 Simulation C 105 C 100 C 95 C 90 C 85 C 80 C 75 C Measurement 70 70 C 160 150 140 130 120 160 C 150 C 140 C 130 C 120 C C 100 100 C 210 210 C 190 170 150 130 190 C 170 C 150 C 130 C C Figure 10: Comparison of the simulation and measurement results of the winding temperatures of the two lamination stacks 11 12

5 Conclusion The simulation results for the lamination stacks with different wire-slot insulations from the previous offer A217279 have been verified within this project. For this purpose, two lamination stacks (test specimens) with identical windings, but with different slot insulations according to Table 1 have been produced. For better heat dissipation, the two lamination stacks were additionally vacuum impregnated. The has set up a test environment with appropriate equipment for the implementation of the measurements. An indirect measuring method was used to determine the temperatures of the individual winding layers in order not to influence the results of the measurements by integrating temperature sensors. For the indirect measuring method, different DC currents have been applied to the windings in order to reach the three coil temperature levels of 100 C, 150 C and 200 C. The voltage has been tapped off at the end windings of different winding layers in the slot. With the aid of the temperature-dependent properties of the conductor it is possible to calculate the temperature in the winding layer section. Due to changes in the boundary conditions compared to the offer A217279 (change in the geometry of the wire, addition of impregnation processes), the simulations for the comparison of measurement and simulation were adapted to the new boundary conditions and new results generated for these two sheet packages. The measurements have shown that with the same DC current, the winding layers reach a significantly lower maximum temperature when Kapton MT + Film is used for the slot insulation. At a temperature level of 100 C, the stationary end temperature of the coil is reduced by 20 K with the new insulation paper, by 26 K at 150 C and by 45 K at 200 C. This is due to the significantly better heat dissipation properties of the new insulation paper (SlotC) in the slot, which has a three times better thermal conductivity. 12 12