For Air Conditioning Systems

Similar documents
Installation manual. Version: October,2008. Daikin Installation Manual EN V01.Doc

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

IP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS

Communicative heating controller

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

SETTOPSURVEY, S.L. Bofarull 14, Barcelona (Spain) Phone: (+34) Fax: (+34)

TRBOnet 5.1 New Features

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Connecting two Phoenix Studio Audiocodecs through a point-to-point IP radio link operating in the 5 GHz band

P2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT

Connecting two Phoenix Studio Audiocodecs through a point-to-point IP radio link operating in the 5 GHz band

Wireless sensor system

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

Quick Start Guide.indd 1 05/11/15 10:07

Functions Added to Smart Camera FQ2 Sensor Software

GPSR116 Quick Start Guide

WJ200 series Pursuing the Ideal Compact Inverter

AIR CONDITIONER. UNIVERSAL - More than 4O A.C brands SPECIFIC. - Mitsubishi Electric. - Daikin - Panasonic - LG. - Midea

Programmable AC Current Transducer MT418

FD423-EA-000 EtherCAT Servo Drive

SRC-110 Series Zone Controllers with Modbus RTU

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

GPSR400 Quick Start Guide

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

Wireless Sensor for Humidity / Temperature / CO 2

CONTROLS CS-I. MFDC/AC Inverter Weld Control

TC LV-Series Temperature Controllers V1.01

AERINOS Profisens - Wireless IoT Platform

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

MA40E Mini Amplifier with DSP

Connecting the Radio:

PowerShare PS604A adaptable power amplifier

Programmable AC Voltage Transducer MT416

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

GCS20K. Conductivity Switch FEATURES

MODEL: WL40MW1F. Wireless I/O WL40F Series

Integrations GW Programming manual

ADJUSTABLE SPEED DRIVES FS1

Main Features. Highlights

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

HC500 Heater Controller

Electrical devices may only be mounted and connected by electrically skilled persons.

Quick Start Instructions EMV-INspektor V2

Citilog XCOM-TS2 and XCOM-TS2-EXT. Interface Boards for Citilog XCAM-P specifications

B850 Boiler House Energy Monitor

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

Relay Driver Overview and Applications

Serial Communications RS232, RS485, RS422

RF Wireless Serial Device Server

TOSVERT TM VF-nC3 Parameter List

Solutions ADVANCED SOLUTIONS FOR SMART COMMUNICATIONS. RADIO DISPATCHER FLEET PHONE APP BRIDGE

R-Log Radio data logger

E3 Adjustable Speed Drive Engineering Specification

Install Guide. EMPower03 Power Monitor 1.1

Before using the Device. Using your Drifta. Connecting to a PC

Built-in soft-start feature. Up-Slope and Down-Slope. Power-Up safe start feature. Motor will only start if pulse of 1.5ms is detected.

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

SpeedTouch 190. Setup and User s Guide. SIP Gateway. Release R1.0

ARP Radio Modem & Router Datasheet

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Installation Manual REbus Beacon. Part of the Pika Energy Island M

Procon MelcoBEMS MINI (A1M)

Sales Bulletin #CT007

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

INSTRUCTION MANUAL FOR ULTRASONIC/MICROWAVE SENSORS

AW900-SPEC USER S MANUAL

FLOW RATE CORRECTION CALCULATOR GDR 1403

i-repeater Control and monitor all your repeaters through the cloud

USB PWM Motor 8810-D. Manual. Date : July, 2013 Version :1.0

PEM353. Universal measuring device

LAUREL ELECTRONICS, INC.

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

Inverter Drive /Vector Drive Motors & Controls

S11 Adjustable Speed Drive Engineering Specification

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

USER GUIDE THIS USER GUIDE WILL TAKE YOU THROUGH ALL THE DIFFERENT INSTALLATION STEPS OF PHANTOM. YOU CAN ALSO ACCESS OUR VIDEO TUTORIALS HERE

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

RC-WIFI CONTROLLER USER MANUAL

MARINE POWER CONVERSION & CONSULTING

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

Setting up a Wires-X node station and why you would want to

FLOW RATE CORRECTION CALCULATOR GDR 1403

Improve asset protection and utilization

DC Resistance Meters 2840 Series

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

ēko Pro Series System

CONTROL MANUAL. Dry-Pic 09PE - 09VE

BAS Integration Manual

ADJUSTABLE SPEED DRIVES. AS1 Drive

Case Air Wireless TETHERING AND CAMERA CONTROL SYSTEM

Quick Start Guide. RSP-Z2 Dual Channel Analog-IP Interface

Transcription:

Quick Guide to on For Air Conditioning Systems (CoolMasterNet - Interface Adapter for Air Conditioning Systems) Mini USB L4 L5 L6 L7 Touch Screen Power 12V DC RS232 L1 L2 Modbus Ethernet Port Air Conditioning Communication Bus Lines: L1 L2: For Mitsubishi Electric, Daikin, Toshiba, Panasonic, Sanyo and Hitachi L4 L7: For Mitsubishi Heavy Industries, LG, Samsung, and Gree T e n w a y s E n g i n e e r i n g S e r v i c e s L t d Page 1 of 5

The CoolMasterNet is an advanced device which acts as a link between an Air Conditioning System and the CoolRemote Web App. The CoolMasterNet communicates with the Air Conditioning System using the Air Conditioning manufacturer s communication Bus Line. The Bus line is used for Intersystem communication between all the units in an Air Conditioning system, as well as for control via a centralised controller. This Bus line is normally present on all VRF/VRV indoor and outdoor units as well as some Split Air Conditioning Units. On split Air Conditioning units where the Bus line it is not present by default, the Air Conditioning manufacturers offer an optional PCB with Bus line capabilities. The CoolMasterNet is able to communicate with all the major Air Conditioning manufactures Bus Lines. Bus Line Names Manufacturer Bus Name Daikin Sanyo Panasonic Toshiba Mitsubishi Electric LG Mitsubishi Heavy Industries Hitachi Samsung DIII Net S Net P Net TCC Link M Net PI485 Super Link / Super Link II H Link Nasa Protocol T e n w a y s E n g i n e e r i n g S e r v i c e s L t d Page 2 of 5

SETUP The CoolMasterNet is simple and easy to install, no IT skills required to set it up. Simply follow these 4 steps: Step 1 Connect a 2 core cable from the Green Connector on the CoolMasterNet to the Air Conditioning Bus (see diagram at the end of this Guide). Step 2- Connect the Power supply using the supplied transformer. Step 3 - Using an Ethernet cable connect the CoolMasterNet to a local router. It will now automatically connect to our CoolRemote servers. Step 4 - Register (http://beta.coolremote.net/registration.php) the CoolMasterNet, select a user name & password. Done! OPERATION Smartphone-Tablet- PC control Once setup is complete, you can now control and monitor the Air Conditioning units using a Smartphone, Tablet or PC. Control options (subject to manufacturer s limitation for some units) are: On/Off (Collective) On/Off (individual) Temperature set point Mode (Cool, Heat, Auto, Fan) Fan Speed Selection Scheduling (Active 2015) Fault Code Display CoolMasterNet Touch Screen Control Control on the Touch Screen On/Off (Collective) On/Off (individual) Temperature set point Mode Selection Fan Speed Selection Fault Code Display T e n w a y s E n g i n e e r i n g S e r v i c e s L t d Page 3 of 5

Home Automation and BMS The CoolMasterNet also connect to Home Automation Systems and Building Management Systems, through IP, RS232 and Modbus RTU. The CoolMasterNet would act as a bridge between these two systems providing a simple solution to a complex problem. Connection Options Diagrams T e n w a y s E n g i n e e r i n g S e r v i c e s L t d Page 4 of 5