SHARDA Make Harmonics Filter

Similar documents
PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

Effects of Harmonic Distortion I

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Power Quality and Harmonic :Causes and Effects with Paper Mill Factory

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

ACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng

Ritz Instrument Transformers GmbH. Welcome

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

K Factor Power Transformers

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

Power Factor & Harmonics

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Electromagnetic Harmonic Filters Technical Guide

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Power Processor - Series 700F 10KVA to 150KVA

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

A PQ Case Study CS 36 HOSP 14. A Case Study OF Harmonics Mitigation in a Hospital and its Benefits

Presents. Harmonics Years

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Subject: Drive isolation transformers. VFD definition: History the short version. February 2012

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Arc Suppression Coils

Open-Delta Systems Affect Variable Frequency Drives

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Pulse Niru Company. General Catalogue.

Cast resin transformers HARMONY TM

TMC Transformers TMC

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Effective Harmonic Mitigation with Active Filters

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

ULTRA-K Series 600K - he

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

VARIABLE FREQUENCY RESONANT TEST SYSTEM

OIL-IMMERSED ARC-SUPPRESSION COILS

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

Line Frequency Transformer

SECTION TRANSFORMERS

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

NSL-10 STANDARD LIFE MODULAR CAPACITORS

Low Pass Harmonic Filters

HOW TO SAFE GUARD THE TRANSFORMER..???

Transformer Factory Testing

Thyristorised Automatic Power Factor

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

7/15/2002 PP.AFD.08 1 of 28

Generator Advanced Concepts

Maharashtra State Electricity Distribution Co. Ltd.

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

Reactor and inductor are names used interchangeably for this circuit device.

Automatic capacitor banks with detuned filters

LC31L-BAT Link Coupler

Power IT LV Active Filters PQFA - PQFL - PQFT

CHAPTER 4 HARMONICS AND POWER FACTOR

FAQ for SIMOREG 6RA70 and Control Module

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

FLOOR ANCHOR SYSTEM APPLICATIONS L TRACK APPLICATIONS

ABB drives. Technical guide No. 6 Guide to harmonics with AC drives

NJWA - Harmonics and Drives Proper System Design

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

thepower to protect the power to protect i-gard LITERATURE Low and medium voltage

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

CAPACITORS. Capacitors for AC and DC General Purpose Applications. Proven EIA-456-A Compliant 60,000 Hour Reliability Industry Standard

WHITE PAPER. Medium Voltage On-Site Generation Overview. BY MIKE KIRCHNER Technical Support Manager at Generac Power Systems

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Power Quality Solutions

Reactive Energy Management

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

Short Circuit Current Calculations

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

Transcription:

SHARDA Make Harmonics Filter SHARDA offers perfect solution to minimize Harmonics level of industries where non-linear load like, VFD, Electronics load, Convertors, Voltage booster equipment s are present. Harmonics Filters are used to reduce Harmonics from the electrical network / system. First, our technical executive analyse full system and as per system requirements to reduce voltage and current harmonics level compliances to IEEE STD 519. We provide tuned or detuned filter. SHARDA manufactures Capacitors and Reactors which is used in Harmonics filter has sturdy design with considering all electrical and mechanical parameters to achieve harmonics level to IEEE standard level in system. Current carrying capacity of reactor is 300% to the rated current. The temperature of the reactor increase at time of full working is only 10% to 20% beyond the ambient temperature. CONCEPT OF HARMONICS Harmonics are integral multiple of some fundamental frequency that, when added together result is distorted waveform as shown in below figure 1 (a), 1 (b) & 2 Fig1 (a) Fundamental Fig1 (b) Harmonics Frequency Frequency Above figures, shows the graph of fundamental as well as harmonics frequency, respectively and the below figure shows how it looks when harmonics enters in to the system. Fig 2 Addition of Fundament & Harmonics Frequency Fig. 3 picture of Harmonics present in system The nature of electrical wave form is as per above figure when Harmonics presents in Electrical network / system.

SYMPTOMS OF HARMONICS WHEN IT PRESENT IN SYSTEM Increase KVA Demand. Neutral Over loading & excessive N-G Voltage. Excessive Capacitor current, frequent capacitor failure. Overheating of transformer. Error in electricity metering i.e. erratic meter reading. CAUSES OF HARMONICS Harmonics are generated by various sources which inherently have non-linear load like VFD, Diode, Computer, & all electronics equipment s. That is generally where frequency as well as voltage conversion system are used. These loads use current in a pulsating manner at times of feed harmonic currents back in to the wiring. In non-linear load current waveform is different from voltage waveform. The major equipment s which generates Harmonics, 1. AC / DC Drives Used in Rolling Mill, CCM etc. 4. Electronics Load 2. Variable Frequency Drives 5. Booster 3. LED 6. Converters STANDARD HARMONIC LIMIT AS PER IEEE Institute Electrical & Electronics Engineering (IEEE) has set recommended limit on both current & voltage distortion in IEEE 519-1992 Voltage Harmonics Limit Sr. No. Bus Voltage at PCC Individual Voltage Total Voltage 1 Below 69 kv 3.0 5.0 2 69 kv to 161 kv 1.5 2.5 3 161 kv & above 1.0 1.5 Harmonics Current Limit Sr No. Isc/I}} <11 11 h<17 17 h<23 23 h<25 35 h Total current 1 <20 4 2 1.5 0.6 0.3 5 2 20-50 7 3.5 2.5 1 0.5 8 3 50-100 10 4.5 4 1.5 0.7 12 4 100-1000 12 5.5 5 2 1 15 5 >1000 15 7.0 6 2.5 1.4 20 Where, Isc: Maximum short-circuit current at the Point of Common Coupling (PCC) IL: Maximum demand load current (Fundamental) at the PCC. Even harmonics are limited to 25% of odd harmonics limits above. Current distortion that result in a DC offset, for example, half wave converter are not allowed. HARMONICS FILTER CONSISTS of, 1. Double Dielectric type ultra heavy duty All PP Capacitor 2. Dry type Aluminum / Copper Reactor (percentage of reactance is depends on harmonics level) 3. Conducting Material : 99% pure Aluminum foil 4. Housing CRCA / Stainless steel Panel. 5. Busbar Aluminum / Copper. 6. Finish Anti corrosive & UV Protected powder coating. FEATURES of CAPACITOR USED IN HARMONICS FILTER Imported raw material Impregnated under high Vacuum Non-PCB insulating fluid. Less Losses High performance Anti UV Protection based paint coated Special design constructions for compliance to high seismic requirement. FEATURES of REACTOR USED IN HARMONICS FILTER Aluminum / Copper wound reactors. Foil based winding to minimize eddy current losses. 300% linearity to withstand heavy fluctuation of current. All reactors are impregnated to circulate in all core. Special design constructions for compliance to high seismic requirement.

PRODUCT RANGE Sr. No. Product Description Product Code Harmonics Filter (As per Bill of Material) 1 50 kvar SE&CHF400050 2 75 kvar SE&CHF400075 3 100 kvar SE&CHF400100 4 150 kvar SE&CHF400150 5 200 kvar SE&CHF400200 6 250 kvar SE&CHF400250 7 300 kvar SE&CHF400300 ** Note: We provides Harmonics Filter as per system / customer requirement. BILL OF MATERIAL Sr. No. Description 01 APP type LV / LT Ultra Heavy duty Capacitor (specially design for Harmonics Filter) 02 Harmonics Filter Series Reactor 03 MCCB for each capacitor step for manual operation 04 Fabrication 14/16 gauge front operated 05 Non corrosive Powder coating after seven tank process. 06 Hinges 07 Lock with panel Key 08 Eye Bolts 09 Aluminum Bus Bar EC grade with HSS sleeves 10 Power & Control cable for all outgoing feeder 11 G.I. Plated hardware, Gasket, Epoxy Insulator 12 Misc. Material like end screw, lugs, PVC channel, Spiral connection etc., SMC support for bus bar TECHNICAL DATA SHEET Sr. No. 1 Make Description Technical data SHARDA Electronics & Co. Plot No. J-32 MIDC Kupwad Sangli, 416436, Maharashtra, India. Make : SHARDA 2 IS Reference IS 5553 3 Type of winding Copper / Aluminum 4 Rated Banking Output 50 kvar to 4000 kvar 5 Rated Voltage 380 volt to 1000 volt 6 Frequency 50 / 60 Hz 7 Detuning Factor 0.2%, 0.4%, 2%, 5.67%, 7%, 14% 8 Linearity 200 % 9 Ambient Temperature 50 C 10 Insulation Class F class 11 Cooling Method Iron core, Natural Cooling (AN) 12 Temperature Sensor Normally Closed at 140 C 13 Installation Indoor, LT panel Mounted 14 Altitude 1000 meter above sea level 15 Max Cont. Current 135% for continues For More details on products and services Pleases communicate our Techno-commercial executive (+91-9503435575) or visit us at www.shardacapacitor.com