Comparative Analysis of Harmonics with and Without Shunt Active Power Filter

Similar documents
HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

Harmonics Elimination Using Shunt Active Filter

Active Harmonics Filtering of Distributed AC System

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

ISSN Vol.03,Issue.07, August-2015, Pages:

Control Of Shunt Active Filter Based On Instantaneous Power Theory

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

COMPENSATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER

Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

ABSTRACT I. INTRODUCTION

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Harmonics Reduction of 3 Phase Diode Bridge Rectifier by Implementing P-Q Theory with Active Filter

2020 P a g e. Figure.2: Line diagram of series active power filter.

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Literature Review for Shunt Active Power Filters

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

ISSN Vol.03,Issue.42 November-2014, Pages:

Cascaded Multilevel Inverter based Active Filter for Power Line Conditioners using Instantaneous mitigates

Simulation Results of a Shunt Active Power Filter with Control Based on p-q Theory

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Review on Shunt Active Power Filter for Three Phase Four Wire System

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Power Quality improvement of a three phase four wire system using UPQC

Application of Fuzzy Logic Controller in Shunt Active Power Filter

ISSN: (Online) Volume 2, Issue 2, February 2014 International Journal of Advance Research in Computer Science and Management Studies

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

PI Controller Based Shunt Active Power Filter with Cascaded Multilevel Inverter

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Power Quality Improvement using Shunt Passive Filter

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

REDUCED COMMON MODE NOISE AND LOWER ORDER HARMONIC IN PUSH PULL CONVERTER BY ACTIVE FILTER

Enhancement of Power Quality Using Advanced Series Active Power Filters

Power Quality Improvement in Fourteen Bus System using UPQC

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

Kanuru; Krishna (Dt); A.P, India. DOI: / Page. 1 G. Aruna Jyothi, 2 DR. P. V. R. L.

Mitigation of Voltage Sag/Swell Using UPQC

Single Phase Shunt Active Filter Simulation Based On P-Q Technique Using PID and Fuzzy Logic Controllers for THD Reduction

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Experimental Results of a Single-Phase Shunt Active Filter Prototype with Different Switching Techniques

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Simulation Study of PWM Techniques for Voltage Source Converters

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

A Comparative Study on Four Time-Domain Harmonic Detection Methods for Active Power Filters Serving in Distorted Supply

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Shunt Active Power Filter for Compensation of System Harmonics

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

Power Factor Improvement Using a Three Phase Shunt Active Power Filter

A Time Domain Reference-Algorithm for Shunt Active Power Filters

Indirect Current Control of LCL Based Shunt Active Power Filter

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

Exploration in Power Quality Furtherance on Shunt Active Power Filter

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

shunt (parallel series

SIMULATION AND COMPARISON OF SPWM AND SVPWM CONTROL FOR TWO LEVEL UPQC

A Novel Control Strategy of Shunt Active Filters

NEUTRAL CURRENT COMPENSATION USING FOUR LEG SHUNT ACTIVE POWER FILTER

Design of Unified Power Quality Conditioner (UPQC) Connected To Three Phase Four Wire System

Fig. 1 Schematic Diagram Showing Connections to the Active Filter With Non-Linear Load

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A NOVEL STRUCTURE FOR THREE-PHASE FOUR-WIRE DISTRIBUTION SYSTEM UPQC

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

Power Quality improvement with Shunt Active Power filter using p-q control technique

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

Design of Shunt Active Filter to Improve Power Quality using Pq Theory

Mitigation of Flicker Sources & Power Quality Improvement by Using Cascaded Multi-Level Converter Based DSTATCOM

Comparison of Various Reference Current Generation Techniques for Performance Analysis of Shunt Active Power Filter using MATLAB Simulation

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Reduction In Total Harmonic Distortion Using Active Power Filters

Performance Analysis of Shunt Active Power Filter Base On Active Reactive Power Theory

Modeling of Shunt Active Filter Using P-Q Theory

SIMULATION VERIFICATION OF DYNAMIC VOLTAGE RESTORER USING HYSTERESIS BAND VOLTAGE CONTROL

Power Quality Improvement using Active shunt Power filter using PI Controller

A New Control Method for Series Active Filter in Distribution System using Unit Vector Control

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Improvement of Power Quality Using a Hybrid Interline UPQC

POWER QUALITY IMPROVEMENT BY HARMONIC REDUCTION USING THREE PHASE SHUNT ACTIVE POWER FILTER WITH p-q & d-q CURRENT CONTROL STRATEGY

POWER QUALITY IMPROVEMENT USING SHUNT ACTIVE FILTER

Transcription:

Comparative Analysis of Harmonics with and Without Shunt Active Power Filter 1 Priya Goswami, 2 A. Pachori 1 PG Scholar (High Voltage Engineering), 2 Associate prof, Dept. of Electrical Engineering, JEC, Jabalpur, India Abstract: Electricity consumption had been increased so rapidly once in line with the development of the country to achieve its status as the industrial countries. The large consumption of electrical energy, one thing that plays an important role in a distribution system is the quality of electrical power itself. The distribution system will have many problems related to efficiency and functionality of electrical equipment. Therefore, the entire system does not operate efficiently due to the presence of harmonic in the distribution system. Among of them, one of the disorders that cause poor power quality is harmonic. This disturbance causes electrical equipment used to heat and cannot function properly. Thereby, the aim of this paper is to design and develop of a three phase shunt active power filter for harmonics reduction in industrial using MATLAB/SIMULINK[1,2]. Keywords: Power System, Harmonic Distortion, Shunt Active Power Filter, Non-Linear Loads, Total Harmonic Distortion. 1. INTRODUCTION Power quality is important in the distribution system. To provide power supply with good quality is not easy because it depends on the type of load used. Phenomenon that causes an interruption in the electrical system such as overvoltage, voltage sags, voltage surges and harmonic [3]. Harmonic distortion problem has existed in the power system for a long time. it causes a wave of the line current and voltage in the power system to be distorted. In the past, discussions about the existence of harmonics have been discussed. However, at that time, the impact and influence of harmonic distortion is slightly lower than at present, where it only covers in the delta grounded w-ye connection of the transformer and also in some design of power transformer [4]. At present, the creation of modern equipment, especially electronic equipment and also the increased use of non-linear loads in industry has produced harmonic distortion, harmonic distortion in electrical systems became more serious because the use of electronic equipment are among the largest contributors to the formation of harmonic distortion. In recent years, with the increasing use of adjustable speed drives, arc furnace, controlled and uncontrolled rectifiers and other nonlinear loads, the power distribution system is polluted with harmonics. Such harmonics not only create more voltage and current stress but also are responsible for Electromagnetic interference, more losses, capacitor failure due to overloading, harmonic resonance, etc. Introduction of strict legislation such as IEEE519 [5] limits the maximum amount of harmonics (THD-Total Harmonic Distortion) that a supply system can tolerate for a particular type of load. Therefore, use of active or passive type filters is essential. To solve the current harmonic related problems, passive filters connected in several circuit configurations present a low cost solution. However passive filter implementations to filter out the current harmonics have the following disadvantages: Possibility of resonances with the source Impedance Supply impedance dependent system performance Fixed compensation Page 156

In order to diminish the preceding disadvantages of the passive filters, active power filters(apf) have been worked on and developed in recent years. Elimination of the current harmonics, reactive power compensation and voltage regulation are the main functions of active filters for the improvement of power quality. APFs have a number of advantages over the passive filters. First of all, they can suppress not only the supply current harmonics, but also the reactive currents. Moreover, unlike passive filters, they do not cause harmful resonances with the power distribution systems. Consequently, the APF performances are independent of the power distribution system properties.on the other hand, APFs have some drawbacks.apf necessitates fast switching of high currents in the power circuit resulting high frequency noise that may cause an electromagnetic interference (EMI) in the power distribution system. Fig.1 Active power filter with non-linear load. 2. INSTANTANEOUS ACTIVE AND REACTIVE POWER THEORY This method offers a good precision and ease of implementation. Its main disadvantage is that it can t be applied in the case of unbalanced grid voltage [13]. In this case, A Self Tuning Filter (STF) can be used after the measurement of the grid voltages to extract the fundamental balanced three phase voltage components of the distorted unbalanced one. This transformation may be viewed as a projection of the three-phase quantities onto a stationary two-axis reference frame. The Clarke transformation for the voltage variables is given by [14]: [ ] = [ ]. (1) [ ] Similarly, this transform can be applied on the distorted load currents to give [ ] = [ ] (2) [ ] The instantaneous active power p(t) can be defined by: ( ) (3) This expression is given in the stationary frame by: ( ) ( ).(4) Page 157

Where, p(t) is the instantaneous active power, p 0 (t) is the instantaneous homo-polar sequence power. Similarly the instantaneous reactive power can be given by: ( ) ( ) ( ) ( ) (5) From eqns. 4 and 5, the instantaneous active and reactive power can be given in matrix form by: [ ] [ ] [ ]...(6) In order to separate the harmonics from the fundamental of the load currents, it is sufficient to separate the alternating term of the instantaneous power from the direct.after the separation of the direct and alternating terms of instantaneous power, the harmonic components of the load currents can be given using the inverse of equation (3.6) which gives: [ ] [ ] [ ].(7) The inverse Clarke transform can be used as follow: [ ] [ ] [ ]..(8) Figure presents the principle of the active and reactive instantaneous power. Fig.3 Principle of instantaneous active and reactive power theory 3. MODELLING OF SHUNT ACTIVE POWER FILTER The simulation model of system without SAPF is shown in fig 4.1 and the simulation model of system with SAPF is shown in fig 3 which shunt active power filter (SAPF) is connected across the non linear load. The control of Shunt active power filter (SAPF) is divided in two parts. First part is used for the harmonic current extraction. There are instantaneous active and reactive power method (p-q method). Second part is used for the generation of gate pulse to control of voltage source inverter. Hysteresis Current Control Method is used. Page 158

3.1 Simulation Model of System without SAPF: 3.1.1 Simulation Result: Fig.4. Simulation model of system without SAPF shows source current without shunt active filter. Due to the presence of the non linear load, so the current waveform is in distorted manner. The current is taken along the Y-axis and time is taken along the X-axis.. Fig.5 Voltage and current waveform without filter Fig.6 voltage and current waveform without filter Fig 7.Voltage and Current Waveform without Filter Page 159

3.2 Simulation Model of System with Shunt Active Power Filter: 3.2.1 Simulation Results: Fig.8 Simulation model of system with SAPF A number of simulations have been performed to check the working of the shunt active power filter under various nonlinear loadings (w.r.t connection of the loads at the PCC) and nonideal supply. The analysis of the results show that the working of the active filter is very satisfied to compensate the harmonics and reactive power even under unbalanced and distorted conditions of distribution supply. Fig.9 Voltage and current waveform with SAPF Fig.10 Voltage and current waveform with SAPF Fig.11 Voltage and current waveform with SAPF Page 160

4. FFT ANALYSIS The following figure shows the THD analysis of source current without SAF. THD is found to be 20.49% respectively due to nonlinear load which creates harmonics in the three phase system. In order to reduce the THD the proposed system is implemented. Figure FFT analysis without SAPF Figure FFT analysis with SAPF Table.1 Comparison of THD in Source Current THD IN SOURCE CURRENT BEFORE SHUNT ACTIVE FILTER THD IN SOURCE CURRENT AFTER SHUNT ACTIVE FILTER 20.49% 0.53% Page 161

5. CONCLUSION The three phase three wire shunt active filter with controller based on instantaneous active and reactive power (p-q) theory is simulated in MATLAB/SIMULINK to compensate the problems of the harmonics and reactive power which are encountered from power electronic non-linear loads. The performance of the shunt active power filter is investigated under different scenarios. It is investigated that the p-q theory based active filter manages to compensate the harmonics and reactive power of the power distribution network even under unbalanced and distorted supply voltages. The active power filter is able to reduce the THD in source current at a level well below the defined standards specified by power quality standards. The THD in source current after the active filtering is not exactly zero. It is because internal switching of the compensator itself generates some harmonics. In each of the case studied, the source current after the working of the active filter becomes perfectly sinusoidal, free from harmonics and in-phase with voltage of the main supply maintaining the unity power factor. In each simulation studied, multiple non-linear loads have been used to investigate the time response of the active filter. In each case it has noted that filter is successfully able to follow the reference currents with one power cycle with change in loads. It has been noted that if voltage unbalance or distortion or both are present in the system, the simple p-q theory didn t work well. It give rise the demand of the fundamental positive sequence voltage detector to extract the fundamental positive voltage form the unbalanced or distorted voltage. Once the fundamental positive sequence voltage is extracted, the theory worked very well. Even though the p-q theory has managed to compensate the harmonics and reactive power of the system and to produce the sinusoidal source current with unity power factor and free from harmonics. 6. FUTURE WORK The scope of the future work can be to look for the solution of the following points: This work is based on three phase three wire system and the active filter does not work well if there is a zero sequence in the supply voltage. In future, a detailed analysis can be carried out for a 3 phase four wire filter in order to compensate the zero sequence present in the system. the APF for the compensation of harmonics and zero sequence. REFERENCES [1] 978-1-4673-0455-9/12/$31.00 2012 IEEE Mitigation of Harmonics using Fuzzy Logic Controlled Shunt Active Power Filter with Different Membership Functions By Instantaneous Power Theory, Suresh Mikkili and Anup Kumar Panda. [2] Akagi, H. 1994. Trends in active power line conditioners. IEEETrans.Power, Electron., vol.9, no.3,pp,263-268.2.bhonsle, D.C., Zaveri, N.K., and Dr.Kelkar, R.B. 2008.Designand Simulation Of Single phase Shunt Active Power Filter for Harmonic mitigation in distribution system.the International Conference on Electrical Engineering. [3] Allmeling, J. A control structure for fast harmonics compensation in active filter Electron.,vol.19, no. 2, pp. 508-514, (Mar 2004). [4] Ali Ajami and Seyed Hossein Hosseini, 2006. Implementation of a Active Filter, ECTI Transactions on Electrical Eng., Electronics, And Communications Vol.4, No.1 [5] Peng, F. Z., Akagi, H. and Nabae, A. A Novel Harmonics Power Filter.IEEE Transaction of Electronics Specialists Conference. April 11-14. PESC 88 Record: IEEE. 1988. 1151-1159. [6] T. Haddad. K. Joos. and A. Jaafari, Performance Evaluation of Three Phase Three and Four Wire Active Filters, Conference Record of the IEEE IAS Annual Metting, pp. 1016-1023, 1996. [7] F. Hamoudi., A. Chaghi., H. Amimeur.,E. Merabet, Sliding Mode Control of a Three-Phase Three-Leg Voltage Source Inverter Based Four-Wire Shunt Active Power Filter, Journal of Electrical Systems, no. 2, pp. 82-86, 2010 Page 162

[8] S. Saetio. R. Devaraj. D. Torrey, The Design and Implementation of a Three-Phase Active Power Filter Based on Sliding Mode Control, IEEE Transactions on Industrial Applications, vol. 31, pp. 993, 1995 [9] H. Akagi. E. Watanabe. M. Aredes, Instantaneous Power Theory and Applications to Power Conditioning, edited by Mohamed E. El- Hawari, ISBN: 978-0-470-10761-4, 2007. [10] S. Buso. L. Malesani. and P. Mattavelli, Comparison of current control techniques for active filter applications, IEEE transaction on Industrial Elactronics, vol. 45 pp. 722-729, 1998 [11] V. Utkin. J. Guldner. J. Shi, Sliding Mode Control in Electromechanical Systems,Prentice-Hall of India Pvt. Ltd. isbn :0-7484-0116-4, 1998 [12] V. Cardenas. N. Viizquez. C. Hernandez. S. Horti, Analysis and Design of a Three Phase Sliding Mode Controller for a Shunt Active Power Filter, IEEE transaction, vol. 4, pp. 219-223, 1999 12th IEEE Workshop on Variable Structure Systems, VSS 12, January 12-14, Mumbai, 2012 978-1 [13] L. Gyugyi and E. C. Strycula, "Active AC power filters", IEEE IIAS Annual Meeting, 1976, p. 529. [14] H. Akagi, Y. Kanazawa, A. Nabae, Instantaneous Reactive Power Compensators comprising Switching Devices without Energy Storage Components, IEEE Transactions on Industry Applications, Vol. IA-20, No. 3, May/June 1984. Page 163