International Journal of Informative & Futuristic Research ISSN:

Similar documents
Underground Cable Fault Detection using Robot

International Journal of Advance Engineering and Research Development. Fault Detection Robot for Underground Cable

Feeder Protection From Over Load and Earth Fault Relay

Distance Measurement of an Object by using Ultrasonic Sensors with Arduino and GSM Module

Soldier Tracking and Health Indication System Using ARM7 LPC-2148

HAND GESTURE CONTROLLED ROBOT USING ARDUINO

Development of a Prototype of a GSM based Underground Cable Fault Detector

Mobile Agent Based Intelligence Power Distribution Control System

IMPLEMENTATION OF EMBEDDED SYSTEM FOR INDUSTRIAL AUTOMATION

GSM Based Water Billing System

International Journal of Research in Advent Technology Available Online at:

ARDUINO BASED DC MOTOR SPEED CONTROL

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: April, 2016

BOAT LOCALIZATION AND WARNING SYSTEM FOR BORDER IDENTIFICATION

International Journal of Current Research and Modern Education (IJCRME) ISSN (Online): & Impact Factor: Special Issue, NCFTCCPS -

RF Based Pick and Place Robot

Multitasking quad copter with hand gesture technology

International Journal for Research in Applied Science & Engineering Technology (IJRASET) DTMF Based Robot for Security Applications

International Journal of Advance Engineering and Research Development. Wireless Control of Dc Motor Using RF Communication

Gesture Controlled Car

Controlling Robot through SMS with Acknowledging facility

IOT Based Smart Greenhouse Automation Using Arduino

MOBILE PHONE SIGNAL JAMMER FOR GSM, CDMA WITH PRE-SCHEDULED TIME DURATION USING ARM7 TDMI LPC2148. K.Navaneetha* 1, Prof.

GPS and GSM Based Transmission Line Monitoring System with Fault Detection Introduction:

Study of M.A.R.S. (Multifunctional Aero-drone for Remote Surveillance)

Multi Frequency RFID Read Writer System

Self-Invented Keypad Based Electronic Notice Board for Wired & Wireless Communication

RFID- GSM- GPS Imparted School Bus Transportation Management System

WIRELESS SPEED CONTROL OF SINGLE PHASE AC MOTOR

AUTOMATIC RESISTOR COLOUR CODING DETECTION & ALLOCATION

WIRELESS THREE PHASE LINE FAULT MONITORING

International Journal Of Engineering Research & Management Technology

GREEN HOUSE USING IOT

Design and Implementation of Integrated Smart Township

Assistant Professor, 2, 3, 4, 5 Students, 1, 2, 3, 4, 5

Development of a Real Time Trains Monitoring System:Case Study of Tanzania Zambia Railway Authority

Design of a prototype to detect mobile phone usage in restricted areas

Four Quadrant Speed Control of DC Motor with the Help of AT89S52 Microcontroller

DISTRIBUTION LINE FAULT DETECTION AND INTIMATION USING GSM

Automatic Load Sharing of Transformers using Microcontroller

DTMF based Surveillance Robot

Object Detection for Collision Avoidance in ITS

IMPLEMENTATION OF AUTOMATIC COLLEGE BELL SYSTEM USING ARDUINO

Energy Efficient Ceiling Fan using BLDC Motor

ATB200. Datasheet. ATB200 GPRS / GPS based Fleet Management Terminal. 1

Automated E-Billing and Supply Control using Power Line Communication

X10 PROTOCOL FOR DATA COMMUNICATION

International Research Journal in Advanced Engineering and Technology (IRJAET)

Online Signature Verification by Using FPGA

GREEN RADIO: ENERGY EFFICIENT MOBILE TOWER NETWORK COMMUNICATION

Above All. The most sophisticated unit for tracking containers in real time for security and management.

Microcontroller Based Speed Control of Induction Motor using Wireless Technology

Bare PCB Inspection and Sorting System

Accident Sensor with Google Map Locator

IOT BASED AUTOMATIC VEHICLE ACCIDENT DETECTIONANDRESCUE INFORMATION SYSTEM

HT12A/HT12E 2 12 Series of Encoders

Electronic Travel Aid for Amaurotic People

International Journal of Advance Engineering and Research Development

Simulation Of Radar With Ultrasonic Sensors

MDSRC Proceedings, December, 2017 Wah/Pakistan

DESIGN OF A DEVICE FOR CHECKING THE CONTINUITY IN ELECTRICAL CIRCUIT

AUTOMATIC MISSILE DETECTOR USING ULTRASONIC PROXIMITY DETECTOR

Auto-Fact Security System

International Journal of Applied Sciences, Engineering and Management ISSN , Vol. 06, No. 02, March 2017, pp

REDUCTION OF HARMONIC DISTORTION IN BLDC DRIVE USING BL-BUCK BOOST CONVERTER BLDC DRIVE

Smart Monitoring and Power Factor Correction of Distribution Transformer using IOT

International Journal of Pure and Applied Mathematics

Anti Drowning system using remote alert

Design and Development of Blind Navigation System using GSM and RFID Technology

Smart Blind Help ABSTRACT I. INTRODUCTION II. LITERATURE SURVEY

Design and Implementation of GSM Based Fertigation System Bhudev Singh 1

Design of WSN for Environmental Monitoring Using IoT Application

AUTOMATIC ELECTRICITY METER READING AND REPORTING SYSTEM

Embedded Based Smart Helmet for Bike Rider's Safety

MICROCONTROLLER BASED SPEED SYNCHRONIZATION OF MULTIPLE DC MOTORS IN TEXTILE APPLICATIONS

Design and implementation of GSM based and PID assisted speed control of DC motor

Speed Control of Single Phase Induction Motor Using Infrared Receiver Module

Auto Selection of Any Available Phase in 3 Phase Supply System

Design and Implementation of AT Mega 328 microcontroller based firing control for a tri-phase thyristor control rectifier

MULTI ROBOT COMMUNICATION AND TARGET TRACKING SYSTEM AND IMPLEMENTATION OF ROBOT USING ARDUINO

POWER LINE COMMUNICATION. A dissertation submitted. to Istanbul Arel University in partial. fulfillment of the requirements for the.

INNOVATIVE ENERGY METER WITH LOAD CONTROL BHARATHY R 1, JHANANI SHREE U 1 and ANITHAMARY M 1 1 Assistant Professor

Azaad Kumar Bahadur 1, Nishant Tripathi 2

WifiBotics. An Arduino Based Robotics Workshop

Luxurious Transporting System

Microcontroller Based Three Phase Fault Analysis for Temporary and Permanent Fault

International Journal of Pure and Applied Mathematics

IOT Based Waste Management System for Smart City

Hardware Implementation of an Explorer Bot Using XBEE & GSM Technology

Wireless technologies Test systems

Keyword: - GSM kit, Transformer, sensors, rectifier, microcontroller, power supply, LCD.. Vol-3 Issue INTRODUCTION

International Journal of Advance Engineering and Research Development AUTOMATIC METER READING FOR ELECTRIC BOARD USING RF (RADIO FREQUENCY)

An Autonomous Self- Propelled Robot Designed for Obstacle Avoidance and Fire Fighting

SPEED CONTROL OF DC MOTOR USING PWM TECHNIQUE

SMART ELECTRONIC GADGET FOR VISUALLY IMPAIRED PEOPLE

DISTRIBUTION TRANSFORMER MONITORING AND CONTROL SYSTEM FOR REMOTE ELECTRIC POWER GRIDS THROUGH GSM

Design and Development of Train Tracking System in South Central Railways

Gesture Controlled Robot with Wireless Camera Monitoring

INTELLIGENT SELF-PARKING CHAIR

A Super trainer with advanced hardware and software features only found in very expensive equipment.

Transcription:

www.ijifr.com Volume 4 Issue 8 April 2017 International Journal of Informative & Futuristic Research Underground Paper ID IJIFR/V4/ E8/ 062 Page No. 7141-7148 Subject Area Elec. & Comm. Engineering Key Words GPS module, GSM module, Live wire scanner, Atmega 328, Robot 1st 2nd 3rd 4th Assistant Professor Vidya P. Kodgirwar Department of Elec. & Comm. Engineering P.E.S Modern College of Engineering, Pune Pooja Gajanan Dharamkar UG Students Ashutosh Dattatray Gawade Department of Elec. & Comm. Engineering P.E.S Modern College of Engineering, Pune Sagar Rajnarayan Gupta Abstract The basic principle of Electromagnetic theory is used to detect discontinuity in the cables laid below the ground. These underground cables are used for many applications. It may be telephone, cable service or may be for internet and data services. Companies prefer laying the cables underground because the climatic adversities don t affect this. With advantages come challenges. There are many difficulties in laying the cables and once laid in case of any complaints, it is difficult and costly to fix it. We have come up with a solution, where the robot that we design in this project is capable of finding where the complaint lies, so that the engineer can directly get the exact location of fault with the help of GPS and notification on respective mobile with the help of GSM technology. I. INTRODUCTION Defect in its electrical circuit takes place due to the current is diverted from the certain intended path and a fault occurs due to this. Faults are generally occurring due to mechanical failure, accidents, excessive internal and external stresses etc. When a fault occurs the power flow gets diverted due to this and supply of neighbouring zone gets affected voltages become unbalanced. Thus, it is of utmost important to detect the fault sooner.in last decade cables were made for overhead laying and currently underground cables are used because of superiority. The biggest advantage is that they are not This work is published under Attribution-NonCommercial-ShareAlike 4.0 International License Copyright IJIFR 2017 7141

affected by adverse weather conditions. Neither hot sunny day nor the rain influences it. But its biggest drawback is to locate the breakage of cable due to any reason. Currently approximate locations are found and the cables are dug out from location and checked manually to find exact point of discontinuity. Cable maintenance practices are of two categories: unplanned maintenance or planned maintenance. Unplanned maintenance is caused due to a power outage. Planned maintenance is a time to time inspection of power cables. Planned maintenance delivers reliable services, but it is not economical. Premature replacement of cables leads to economic losses, which can be avoided by replacing decision based on the specific site data rather than on generic estimates.the cable inspection is a very costly process. A broad spectrum of sensing is used for the inspection of cables. Some of these sensing methods are like acoustic detection, are greatly enhanced by the ability to make measurements along the cable, as opposed to relying on measuring parameters at the ends of the cables.the goal of this project is to develop an autonomous robotic platform that can inspect underground power distribution cables, thus providing utilities with accurate information regularly and at a lower cost. Currently developed robot can be used to locate break from an external point. When an underground cable is broken or short circuited then our robot will work over it and locate the exact point of discontinuity. II. PREVIOUS WORK 1. The model of a mobile robot is made that can inspect the conditions in an underground cable tunnel even in dangerous environmental conditions where human presence is harmful. Hence, this robot substitutes the inspection of a human in the underground cable tunnel. The robot does online inspection through the tunnel travelling from one end to other end and all the information about the underground tunnel with respect to temperature, presence of harmful gases, obstacles, fire accidents, failure in supply etc. is transmitted wirelessly to a device on the ground [1]. 2. The robot is made which is capable of finding the location where the complaint lies, so the engineer can directly get the hole dug at that point and fix the issue. The fault detection robot consists of a signal generator part and robotic part. Short circuit cable is checked for its continuity by passing a 3 KHz low frequency signal. The AC signal passing through wire produces a magnetic field around it. This magnetic field is sensed by the robot using an inductor circuit. The AC signal sensed by robot is then amplified using an LM386circuit. This amplified signal is then rectified and converted to DC. DC level is provided to the analog input of microcontroller. Microcontroller converts this analog input to digital signal. When the robot reaches the point where the discontinuity lies, the magnetic field will be zero. In such case the input signal at the analog input port will be substantially low. When the input signal strength is less than 10 (binary reading), the PIC is programmed to display, short circuit Detected and is displayed in LCD [2]. 7142

3. A robot is designed who will find out correct location of fault then by using GSM technology message will send to main control room. So, the engineer can directly dig at that point & fix the issue. The rising demand for electrical energy increases the importance and priorities of uninterrupted service to customer. The current sensing circuit is interfaced to the microcontroller. The 16*2 LCD display connected to the microcontroller is used to display the information. GSM will send SMS to the control room as fault detected [3] III. DESIGN OF ROBOT Figure 1: Block diagram of underground cable fault detection 1. POWER SUPPLY We are using linear regulated power supply having 5V output which will be useful for driving the other components in the circuit like microcontroller, gsm module and GPS module. 2. LIVE WIRE SCANNER CD4017 When we hold the sensor (metallic conductor or copper wire) close to the live wire, electric field from mains activates the circuit. As the input impedance of the CMOS IC is high, the electric field induced in the sensor is sufficient to clock it. The output obtained at pin 11 of CD4017 drives the LED. Flashing of the LED (LED2) indicates the presence of mains, while LED1 indicates that the scanner is active. 7143

3. RF TRANSMITTER (HT12E) - They are capable of encoding information which consists of N address bits and 12N data bits. Each address/data input can be set to one of the two logic states. The programmed addresses/data are transmitted together with the header bits via an RF upon receipt of a trigger signal. The capability to select a TE trigger on the HT12E enhances the application flexibility of the 212 series of encoders. 4. RF RECEIVER (HT12D) - The decoders receive serial addresses and data from a programmed 212 series of encoders that are transmitted by a carrier using an RF medium. They compare the serial input data three times continuously with their local addresses. If no error or unmatched codes are found, the input data codes are decoded and then transferred to the output pins. 5. BRUSHLESS DC MOTOR - The BLDC motor is widely used in applications including appliances, automotive, aerospace, consumer, medical, automated industrial equipment and instrumentation. The BLDC motor is electrically commutated by power switches instead of brushes. Compared with a brushed DC motor or an induction motor, the BLDC motor has many advantages. Motors convert electrical energy into mechanical energy using electromagnetic principles. The energy conversion method is fundamentally the same in all electric motors. 6. MICROCONTROLLER AT mega 328 - Arduino Uno microcontroller board based on the ATmega328.It is Open-source hardware, open source software. Boards are available commercially in preassembled form. Large number of PWM pins available. Pins can be configured as I/O and o/p as per requirement. 7. LCD - When the voltage is zero, the robot displays fault is detected on the LCD. 8. GSM MODULE (SIM-900) - GSM/GPRS RS232 Modem from rhydolabz is built with S IMCOM Make SIM900 Quad-band GSM/GPRS engine, works on frequencies 850 MHz, 900 MHz, 1800 MHz and 1900 MHz it is very compact in size and easy to use as plug in GSM Modem. The baud rate can be configurable from 9600-115200 through AT command. Initially Modem is in Auto baud mode. This GSM/GPRS RS232 7144

Modem is having internal TCP/IP stack to enable you to connect with internet via GPRS. It is suitable for SMS as well as DATA transfer application in M2M interface. 9. GPS MODULE - The GXB5005 is a 12-channel GPS (Global Positioning System) receiver module. This small module includes all the functions required for GPS and is designed for using an active antenna. The GXB5005 can support the various kinds of the portable applications as well as the car navigation system. IV. ALGORITHM OF SYSTEM 1. START. 2. Power is given to the circuit. 3. RF transmitter transmits the signal to RF receiver wirelessly. 4. RF receiver gives signal to motor driver and Robot moves in respective direction. 5. Live Wire Scanner will detect the discontinuity in the cable. 6. If there is no discontinuity, then Robot will move in the respective direction. 7. If there is discontinuity, then microcontroller will send stop signal to the motor and motor will be stopped and LCD displays a message that fault is detected. 8. Message will be sent through SMS on respective mobile phone by GSM. 9. And the location of the fault detected by by Robot will be sent on respective mobile phone by GPS. 10. Go to step 2. V. SIMULATION RESULT MOTOR DRIVER-LS293D: Condition 1- Figure 5.1: OFF Condition for motor driver module Condition 2-When condition 01 is applied i.e. first push button is untouched and 2nd button is closed. 7145

Figure 5.2: Clockwise movement of motor driver Condition 3-When condition 10 is applied i.e. 1st push button is pushed and 2nd one is untouched. Figure 5.3: Anti-clockwise movement of motor driver VI. EXPERIMENTAL TESTING Figure 6.1: Photo of the proposed system 7146

Currently designed robot can be used to locate fault in underground cable system. When an underground cable is broken or short circuited then our robot will work over it and locate the exact point of discontinuity. This robot works on the principle of electromagnetic theory. We can directly get the exact location of fault with the help of GPS and notification of fault location on respective mobile with the help of GSM technology [2]. VII. CONCLUSION 1. The aim of the project is realized by testing the inspection of a mobile robot in a virtual environment conducive in producing real time operating atmosphere of an underground cable which can accurately spot the fault point and can report the coordinates of the fault point, which is novel attempt by using a GPS tracker. 2. Current scenario of digging along the cable laid and then pulling the cable out and checking whether the fault exists in the cables is a tedious work. This is not only being wastage of manpower and money for the companies, but this also causes a lot of inconvenience to the normal public. We believe that our cable fault detection robot will solve this issue to a great extent and will be really helpful for such application. The robot that we have designed is very much user friendly and can be easily controlled. VIII. ACKNOWLEDGEMENT We wish to thank the head of the department of electronics and telecommunication, Modern college of engineering. We would like to express special appreciation and he artful thanks to our guide Mrs. V.P.Kodgirwar for giving helpful guidance, suggestions and directions for the preparation of the project work. We also sincerely thank all our teachers for the valuable support. IX. REFERENCES [1] Merugumalla Manoj kumar, Pasumarthi Vishnuvardhan, Pudota Ignatius Sirisha, Robotic Cable Inspection System Using Microcontroller and GPS Tracker, International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, Vol. 3, Issue 3, March 2014. [2] Jery Althaf, Muhammad Imthiaz, Rejith Raj, Underground Cable Fault Detection using Robot, International Journal of Electrical and Computer Engineering (IJECE), Vol. 3, No. 2, April 2013. [3] Miss Nikam Radhika R, Miss Tandale Swapnali S, Prof. Talewad Gururaj, Underground Cable fault finding Robot Using GSM Technology and AT MEGA 16 interfacing, International Journal of Civil, Mechanical and Energy Science (IJCMES), Vol-2, Issue-2, March-April, 2016. [4] Bing Jiang, Alanson P. Sample, Ryan M. Wistor, Alexander V. Mamishev, Autonomous Robotic Monitoring of Underground Cable Systems, IEEE, Vol. 4, Issue December 2005 [5] M.-S. Choi, D.-S. Lee, and X. Yang, A line to ground fault location algorithm for underground cable system, KIEE Trans Power Eng., pp. 267 273, Jun. 2005. 7147

[6] E.C. Bascom and D.W. Von Dollen, Computerized underground cable fault location expertise, in IEEE [7] Power Engineering Society Transmission and Distribution Conference, pp. 376 382, 10 15April1994. [8] Charles A. Maloney, "Locating Cable Faults", IEEE Transactions on Industry Applications, Volume IA-9, No.4, July-August 1973. [9] F.S. Nickel, T.M. Salas, D.E. Thomas, and C.M. Wiggins, "Advanced Cable Fault Locator, Final Report, EPRI EL-7451, October 1991, Electric Power Research Institute, Palo Alto, California. [10] Dhivya Dharani.A, Sowmya.T Development of a Prototype Underground Cable Fault Detector, ISSN (Online): 2347-2820, Volume -2, Issue-7, 2014. [11] Jiang B, Stuart P, Raymond M,Villa D, Mamishev A.V 2002. Robotic platform for monitoring underground cable systems. Transmission and Distribution Conference and Exhibition Asia Pacific. IEEE/PES Volume: 2 TO CITE THIS PAPER Kodgirwar,P.V., Dharamkar,G.P., Gawade,D.A., Gupta, R.S. (2017) :: Underground International Journal of Informative & Futuristic Research (), Vol. 4 No. (8), April 2017, pp. 7141-7148, Paper ID: IJIFR/V4/E8/062. 7148