OUTPUT CHARACTERISTICS

Similar documents
PTE-50-CET. Three phase relay test set Current/Voltage

PTE-100-C / PLUS / PRO

PTE-100-C. Current and Voltage Relay testing unit to 250A

T 1000 PLUS Secondary Injection Relay Test Set

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

Universal Protective Relay Test Set

Advanced Test Equipment Rentals ATEC (2832)

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

SVERKER 900 Relay and Substation Test System

FREJA 306 Relay Testing System

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

N. TEST TEST DESCRIPTION

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

N. TEST TEST DESCRIPTION

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Arbitrary/Function Waveform Generators 4075B Series

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Signet 9950 Dual Channel Transmitter

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

Photovoltaic / Solar Array Simulation Solution

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

High Speed Milliohm Resistance Meter

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

22 kw 4Q POWER AMPLIFIER RS232

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Models 296 and 295 combine sophisticated

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Moving Test - MT3000

PD300. Transformer, generator and motor protection Data sheet

Computer-14d - xx - 144a

MIT510/2, MIT520/2 and MIT1020/2

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

SVERKER 750/780 Relay Test Sets

2026Q CDMA/GSM Interferer MultiSource Generator

FEATURES DESCRIPTION THE OEM ADVANTAGE

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

RS232. DC POWER SUPPLY 20kW 3 RANGES

DC Resistance Meters 2840 Series

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

1510A PRECISION SIGNAL SIMULATOR

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

3050 Stereo Power Amplifier

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

Data Sheet. DG1000 series Dual-Channel Function/Arbitrary Waveform Generators. Product Overview. Main Features. Applications. Easy to Use Design

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

WD series DIN Rail or Screw Mounted Protective Relays

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

IRT Mini Evo. Technical Manual. quality IN MOTION. quality IN MOTION

Battery Analyzers BA6010 Series

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Voltage Transient Emission Test

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

COPYRIGHTED MATERIAL. Index

ALL-TEST IV PRO. Very Easy To Use. Economical! MOTOR CIRCUIT ANALYZER PREDICTIVE MAINTENANCE QUALITY CONTROL TROUBLE SHOOTING

RIGOL Data Sheet. DG1022 Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Supplemental Motor Protection Devices Specifications

MIT510, MIT520 and MIT1020

Advanced Test Equipment Rentals ATEC (2832)

TOSHIBA International Corp

DC Electronic Loads 8500 Series

AF91 Adjustable Frequency Drives Series B

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

Signet 9950 Dual Channel Transmitter

BOP 1 KILOWATT 1000 WATTS OF FOUR-QUADRANT BIPOLAR POWER FROM KEPCO AN ISO 9001 COMPANY

VF-nC1 Adjustable Speed Drive Engineering Specification

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Advanced Test Equipment Rentals ATEC (2832)

Model 7000 Low Noise Differential Preamplifier

ODEN AT Primary Current Injection Test System

RIGOL Data Sheet. DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A. Product Overview. Main Features.

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Stabilized Differential Relay SPAD 346. Product Guide

Boulder W Mono Power Amplifier

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

DC PRECISION "HIGH CURRENT" SOURCES / RANGE EXTENDERS

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

INSTRUMENT DRTS 66 FOR TESTING PROTECTIVE RELAYS, ENERGY METERS AND TRANSDUCERS

AMX Series. Precision AC Test Power Single and Three Phase Linear AC Power Sources. Parallelable to 30 kva. T h e P o w e r o f E x p e r t i s e

Transcription:

ELECTRONIC PTE RANGE Protective relay test sets with direct on-board control and computer-based test automation THE ELECTRONIC PTE TEST EQUIPMENT RANGE The electronic PTE test equipment range has been designed for maximum efficiency and simplicity when testing protective relays in the field. These universal, rugged and powerful units provide the required accuracy and performance to test any electromechanical, static, or numerical relay. Output waveforms are digitally synthesized, and completely isolated from the mains supply. The signal is then electronically amplified to attain up to 50 A or 300 V with an effective power of 100 VA. 2 PTE-50-CET PTE-300-V PTE-50-CE PTE-100-V FLEXIBILITY The range includes four products: the PTE-300-V, with three output channels, and the smaller PTE- 100-V, with one channel only, are mainly designed for voltage-related protections like generator, motor and synchronizing relays. The other two (PTE-50-CET and the one-channel version PTE-50-CE) are specially powerful in current-based testing. Each output channel in these units can be switched between current and voltage injection by just pressing a button. Amplitude and phase angle can also be adjusted independently in each channel. One of the biggest advantages in the PTE sets is their ability to communicate to each other, in order to use all their output channels simultaneously. You can purchase several simple units for the most frequent testing and, when time arrives for more demanding tasks, interconnect two or three according to the application s requirements. This is a cost-effective solution when you need more than one test set. Furthermore, the PTE units can also be used in combination with equipment from other manufacturers, thanks to their built-in external synchronization input. Need computer-generated reports? Not only does the PTE range feature the best manual control board in the market, but also the possibility to operate automatically under the control of optional software from a standard computer. This capability is especially useful when a great number of different protections must be tested periodically. Relay types and test routines are stored in a custom-defined database, so that you only need to double-click on each installed relay s entry to perform the complete test process and to save and produce a report in a fully unattended manner. The automatic testing software can also control combinations of several PTE units as if it was a single device. POWER Behind the 100-VA output power in the PTE channels, you will find a generous duty cycle and a great number of test resources. For example, several channels can be controlled from a single button, even if they belong to various interconnected units, thanks to the master/slave function. And you can refer the phase angle of each channel or the base frequency of the harmonics function to an incoming signal from an external generator, or setup ROCOF frequency ramps in less than one minute without a computer. The PTEs feature an idle power mode to save energy and keep the amplifiers cool when testing low impedance relays. Each output channel provides an independent neutral, which enables the interconnection of two or more channels in series or in parallel with absolute freedom. The optional PTE-SER plug allows the injection of up to 50A with a compliance voltage of up to 60V in the PTE-50-CET. OUTPUT CHARACTERISTICS PTE-50-CE PTE-50-CE Pro PTE-50-CET PTE-100-V PTE-300-V Output channels 1 2 3 1 3 Current per channel 0-50 A 3 x 0-50 A 0-8 A 3 x 0-8 A Voltage per channel 0-150 V 0-150 V, 0-140 V 3 x 0-150V 0-300 V 3 x 0-300 V Frequency 1º - 7º harm. 1º - 7º harm., 40-70 Hz 1º - 7º harm. 40-420 Hz Chronometer Yes No

Digital timer Harmonics selector UNO (PTE-50-CE + PTE-100-V) Complete single-phase system with chronometer, frequency generator and two reversible channels (50 A + 300 V, 50 A + 8 A, 150 V + 300 V or 150 V + 8 A) OTRO (PTE-50-CET + PTE-100-V) 4-channel system with chronometer and frequency generator (3 x 50 A + 300 V, 150 A + 300 V, 3 x 150 V + 8 A, 450 V + 8 A etc.) Current / voltage channel ASSISTED MANUAL CONTROL The comprehensive and well-designed control board in the PTE units provides fast and accurate operation for the simplest one-shot testing to the most complex dynamic fault simulation. The board s design and the studied position of each control and button is uniform and coherent, so that all the units are operated in the same way. The three-channel versions feature a master/slave function that allows to control and adjust two or three channels simultaneously from channel #1. You just adjust the pre-fault and fault quantities, launch the simulation and note the reading from the chronometer. Dynamic simulation Each channel can store two sets of amplitude (voltage or current) and phase angle parameters in memory. You can then step into fault state from zero or from non-fault values. You can also edit and playback digitized transients in COMTRADE format from an external PC using optional software. Control BUS The EuroSMC s exclusive PTE BUS, supplied as standard equipment, allows the interconnection of up to five PTE units in order to use all their output channels simultaneously. Phase and frequency synchronization signals, as well as output control messages, timer start/stop commands and trip signal detection messages, are transmitted by this high-speed bus in real time. Any unit can be set as master or slave in the system s operational hierarchy. The PTE BUS integrates the resources of each individual unit into a single virtual system that can be operated from the master unit or from an external computer. Digital Instrumentation All the instruments are digital, including the chronometer, the frequency generator and the injection measurement displays. Quantities are adjusted with contact-free digital encoders on high-contrast LED indicators. The adjustment speed and resolution is easily controlled by selecting the digit to be modified. The chronometer features six start/stop modes selectable by pressing a button, and can be set to display milliseconds or cycles of the working frequency. The frequency generation module features a fully programmable ramp for ROCOF testing and a direct adjustment method with two modes: absolute frequency and delta (incremental) mode referred to an external signal s frequency. TRES (PTE-50-CET + PTE-300-V) Complete three-phase system with up to 6 current or 6 voltage channels (3 x 50 A + 3 x 300 V, 150 A + 900 V, 3 x 50 A + 3 x 8 A, 3 x 50 A + 900 V, etc.) 3

ELECTRONIC PTE RANGE Selectable frequency and phase angle reference The frequency and phase reference for the generation of the sinusoidal output can be chosen from various sources by just pushing a toggle button. You can select, for example, an internal frequency generator, the supply s line, an external signal at the synch input or the active source in another PTE unit connected to the bus. Lightweight nylon bag INTEGRAL PROTECTION Output amplifiers are safeguarded against overheating and overload by electronic protections that resume the output automatically when the trouble is cleared out. Furthermore, the complete isolation between amplifiers prevent accidental damages from being propagated between channels, so that the healthy channels in the unit can still be used while the damaged module is repaired. 4 PTE-300-V

PTE-50-CE PRO Any test set in the PTE range can be upgraded with an additional voltage source, the PTE-FCN option. This electronic, independent source can be adjusted in amplitude, frequency, and phase angle. It comes installed as standard with the 'Pro' versions of the PTE sets, but it can also be purchased separately and mounted by the user inside the unit's lid in a few minutes. The PTE-FCN will dramatically increase the relay types that can be tested, usually avoiding unnecessary investment in three-phase equipment. The PTE-50-CE Pro, for example, is an unbeatable single-phase test set for directional, frequency, synchronisation and generator protection relays. PTE-FCN optional voltage source Current / voltage reversible channels 100 VA power per channel Up to 50 A and up to 300 V per channel Manual, direct or automatic, pc-controlled operation Multi-unit bus architecture with centralized control External signal synchronization input Electronic protection against overload and overheating Supply-independent digitally generated waveform Automatic generation of 2nd to 7th harmonics Digital multimode chronometer Programmable frequency ramp Serial and parallel interconnection of channels Up to 150 A and 900 V single-phase injection Depending on model APPLICATIONS OVERVIEW (See Compatibility Chart on the next page) Single- and three-phase testing of electromechanical, static and numerical protective relays Motor protection testing Differential protections testing Generator protection testing Reclosing and synchronization relay testing Low-voltage protections testing at line levels Impedance relay testing Directional protection testing COMTRADE transient playback Automatic relay testing and reporting In three-channel models 5

ELECTRONIC PTE RANGE TESTABLE IEEE RELAYING FUNCTIONS IEEE No. Protective device PTE-50-CE PTE-100-V PTE-300-V PTE-50-CET UNO PTE-100-V PTE-100-C PTE-300-V PTE-50-CE PTE-300-V PTE-100-C PTE-50-CET PTE-100-V 2 Timing relay 21 Distance 1Ø Pro 21 Distance (open delta) 21 Distance 3Ø 24 Volts / Herz Pro 25 Synchronization Pro 27 Undervoltage AC / DC 32 Directional power 1Ø 32 Directional power 3Ø 37/76 Under- and Overvoltage DC 40 Loss of field 46 Reverse phase sequence Pro 46N Negative sequence overcurrent 47 Reverse phase voltage Pro 49 Thermal relay 50 Instantaneous overcurrent 51 Timed overcurrent 55 Power factor relay 59 Overvoltage 60 Voltage balance Pro 64 Neutral detection 67 Directional overcurrent Pro 67N Directional neutral overcurrent 78 Angle / out of step 79 Reclosing relay 81 Frequency relay Pro 82 DC reclosers. 85 Carrier or pilot wire protection 87 Differential protection 91 Directional voltage 92 Directional power and voltage 94 Tripping relay Options required Pro: with the PTE-FCN module Partially tested TRES PTE-30-CH PTE-FCG PTE-12 PTE-GPS PTE-SER OPTIONAL ACCESSORIES The PTE-FCG battery simulator can be used externally or fitted inside the lead of the three-channel models. It provides a 60W supply of 48, 125 or 250 VDC to energize any electronic or numerical relay during the tests. The PTE-12 interface allows the integration of a personal computer in the PTE-BUS for software based operation of the PTE equipment. It also implements the PTE-COM command interpreter that enables the user to build his own automation applications using popular programming languages like Visual Basic or C++, as well as any scripting language featuring RS-232 communications control. The PTE-GPS receiver enables the synchronization of two test sets located at any distance in order to initiate a software-based test simultaneously with an accuracy of 1 microsecond. The PTE-SER set of connectors allows the interconnection of two or three channels in series in the PTE-50-CET when currents of up to 50 A are required on extremely high burdens, with compliance voltages up to 60 V. The PTE-30-CH handheld chronometer can complement the PTE-300-V and PTE-100-V models for time-based testing if no other PTE unit with a built-in chronometer is available. It features the same functions as the built-in version and can measure the time of any electrical event in dry contacts or voltages up to 250Vac/dc with an accuracy of 1 ms. The PTE-FCN module, featured as standard in the PTE-50-CE Pro, provides an additional voltage, frequency and phase angle adjustable source, remarkably increasing the relay types that can be tested. It can be purchased separately and installed inside the unit's lid in a few minutes. 6

Eurotest RTS EuroFAULT SOFTWARE APPLICATIONS The PTE range of relay testing equipment offer the best of both worlds: a powerful, yet easy to use control panel and the capability to communicate with a computer to do the testing and the reporting automatically, by means of optional software applications: Eurotest RTS This powerful software uses the widely known Microsoft Access database technology to organize the test routine definitions, the settings and the historical results of the tests conducted in all your installed relays. The program comes with a database containing pre-defined test routines for dozens of popular relays in the market, ready to be used. This database is periodically updated and can be downloaded by service subscribers at any time. The existing routines can be easily adapted to other relays with minor changes, and the user can build his own test routines from scratch with the help of the FasTEST assistant, that guides the user throughout a menu of selections according to the type of protection and type of test he wants to create. Every installed relay is recorded in the system table along with its nameplate data and its working settings, and a map is configured to resemble the actual location of each relay in the user s maintenance plan. The testing is launched with a simple mouse click and results are displayed and automatically attached to the relay s entry in the database for future reference or report generation. Eurotest RTS can operate any of the models described in this catalogue, as well as any combination of two or more units in the PTE-BUS automatically. EuroFAULT If you have oscillographic recordings of faults and transients in digital COMTRADE format, you can play them back into your relay with EuroFAULT. You only need to open the file from the program, assign the voltage and current components to the available channels in your PTE unit or combination and click on PLAYBACK. EuroPACK EuroPACK is a cost-effective software suite containing EuroTEST RTS and EuroFAULT if you happen to need both applications. PTE-COM PTE-COM is the command language used by software applications to control the PTE equipment from a computer. The PTE-COM commands, interpreted by the PTE-12 interface during the software-controlled test process, are available to the users for the development of their own custom applications and test automation procedures, if needed. Remember that you will need the PTE-12 interface to control the PTE units from a computer, regardless the software application used. Do not hesitate to call for any questions related to software-based applications of your PTE equipment, or to any other aspect of the products described in this catalogue. EuroSMC s technical staff will be very pleased to help and to provide you with the appropriate suggestions for the optimal use of your PTE equipment. PTE-COM sample application 7

ELECTRONIC PTE RANGE SPECIFICATIONS REVERSIBLE OUTPUT CHANNELS DIGITAL CHRONOMETER (PTE-50-CET, PTE-50-CE) Range Accuracy Start modes Stop modes TRIP MONITOR Dry contact input Voltage input EXTERNAL REFERENCE INPUT 0.001-99999 s. o 0.1 9999.9 cycles ±0.003% of reading ±1 digit Output ON or OFF Pre-fault / fault state switching PTE BUS event External START signal NO or NC contact Voltage ON / OFF PTE BUS event Open circuit voltage: 10.2 Vdc Short circuit current: 25 ma Voltage input Fuse protected 5-250 Vac/dc Impedance: 19 kω Fuse protected Current input Input impedance 47 kω 25 mω Signal range 5 300 Vac 0.1 25 Aac Frequency range PTE-50-CET PTE-50-CE PTE-300-V PTE-100-V Number of channels 3 1 3 1 Interconnections Serial or parallel Serial or parallel Current ranges 0-0.330 A / 0-8.000A / 0-25.00A / 0-50.00A 0-0.330A / 0-8.000A Voltage ranges 0-6.25V / 0-150.0V 0-6.25V / 0-150 V / 0-300V Harmonics generated 1st 7th automatic in each channel Manual, up to 420 Hz Phase angle 0-359.9º Frequency range Parametric: 40.00-420.0 Hz Transient: 0.5-5000 Hz Power per channel 40-70 Hz 100 VA Accuracy ±0.5% Distortion GENERAL 1% máx. FREQUENCY GENERATOR (PTE-300-V, PTE-100-V) Modo normal STANDARD ACCESSORIES Complete 2-m / 6,5 ft. test lead set 1.5-m / 4,9 ft. power cord 4-mm terminal adapters 4-mm crocodile clip set RS-232 communications cable PTE BUS interconnection cable Set of replacement fuses Coaxial BNC to 4-mm connection cable Nylon bag for test set and accessories Calibration software User manual in English Certificate of calibration Modo diferencial Range 40-420 Hz 0.001-10 Hz Resolution 0.01 / 0.1 / 1 Hz 0.001 / 0.01 / 0.1 Hz Accuracy 1 digit ±0.003 Hz 1 digit ±0.001 Hz Ramp limits 0.1 10.0 Hz/s. _ Ramp lapses 0.1 10.0 s. _ PTE-FCN OPTION Output power Voltage output Max. current 30 VA (70 140 Vac) 0 140 Vac (res.: 0.1V) 0.45 A (0 70 Vac) Phase angle 0 359.9º (res.: 0.1º, Vout> 5V) Frequency Phase reference PTE-50-CET PTE-300-V PTE-50-CE PTE-100-V Weight 25 Kg / 55.1 lb. 22 Kg. / 48.5 lb. 13.5 Kg. / 29.7 lb. 13.5 Kg. / 29.7 lb. Dimensions (mm) inches Auxiliary voltage output 442 x 327 x 200 17.4 x 12.8 x 7.8 in 110 Vca / 0.3 A máx. Supply power 230 / 110 Vca ±10% Temperature range 300 x 200 x 200 11.8 x 7.8 x 7.8 Storage : -20 to 70ºC / -4º F - 158º F / Operation: 0 to 50ºC / 32ºF - 122º F 40 70 Hz (res.: 0.1 Hz) AC supply or internal generator Please note: Due to the continuous research and development by EuroSMC, specifications in this catalog may be changed without previous notice. PTECCEN - Version 3 DISTRIBUTED BY: EuroSMC, S.A. Polígono industrial P-29, Calle Buril, 69 28400 Collado Villalba. Madrid (Spain). Tels: +34 91 849 89 80 Fax: +34 91 851 25 53 www.eurosmc.com e-mail: sales@eurosmc.com