SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

Similar documents
SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Brunata Optuna H. Properties. Counter

RAY COMPACT ENERGY METER MECHANICAL

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY MC COMPACT ENERGY METER MECHANICAL

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter

RAY MC COMPACT ENERGY METER MECHANICAL

INFOCAL 8 Energy calculator

SonoMeter 31 Energy Meters

WESAN WP E ELECTRONIC METER WOLTMAN

Infocal 9 Energy calculator

ULTRASONIC D. Compact ultrasonic heat meter

SonoSelect 10 and SonoSafe 10 Energy Meters

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

SONO 1500 CT Ultrasonic flow sensor

SONOMETER TM 1000 Ultrasonic compact heat meter

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

MULTICAL 302 DATA SHEET

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Supercal 531 Multi function Integrator that lives up to Your highest expectations

HDU-SF (Horizontal Distribution Units - Single Flat)

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

MULTICAL Energy meter TS PTB. Application

Heat meter Q heat 5 US

MULTICAL 403. Data sheet

SONOMETER 2000 Ultrasonic heat meter

SVM F22. Calculator for heating or cooling applications. Data sheet

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

MULTICAL 601 DATA SHEET

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ultego III smart plus

Release A Member of the

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling)

MULTICAL 403. Data sheet

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Ultrasonic heat and cooling energy meters

FLOMID FX Electromagnetic Flowmeter

ULTRAHEAT T230 ULTRACOLD T230

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

flowiq 3100 Data sheet

ULTRAFLOW TS Application OIML R75 DS/EN 1434

Technical Description MULTICAL 302. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

UTM10 Series Ultrasonic Transit-time Flowmeters

MULTICAL 602 DATA SHEET

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

A Member of the. Integrated Metering Technologies

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron

User s Manual. F2 Calculator. A metering component for thermal energy applications

flowiq 3101 DATA SHEET

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat)

mass flowmeter for compressed air

Electronic Heating Energy Meters

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

E l e c t r o m a g n e t i c f l o w m e t e r s

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Datasheet (Preliminary) Modular Inverter System VARIS Datasheet VARIS

WATERFLUX 3070 Technical Datasheet

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

A T u n e d M e a s u r e

SVM F27 Compact. Compact heat meter. Users manual

sustainable savings that can be viewed directly on the internet

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Model Sono-Trak Transit Time

MID MP-01, MP WATER MEASUREMENT

FAST SAMPLING CONVERTER

HMM/CHW CHW Heat Meters

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

flowiq 3100 Data sheet

FLOW RATE CORRECTION CALCULATOR GDR 1403

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Datasheet. Modular Inverter System VARIS Datasheet VARIS

Energy Management Energy Analyzer Type EM112

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Multifunctional counter tico 772/773/774

ph or ORP Transmitter

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Energy Management Three-phase energy meter with output modules Type EM4-DIN

The innovative way forward symphonic sensor net radio system

HMM/LPHW LPHW Heat Meters

ICARUS ELECTRONIC GAS VOLUME CONVERTER

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Digital Multifunction Instrument - Rish Master 3440

Transcription:

APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the measurement of the transit time. Ultrasonic technology offers many benefits: no moving parts (avoids wear and tear of the metering components), low pressure loss, large metering dynamics and low start flowrate, insensitiveness to suspended particles... FEATURES 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 4 Complete range from DN 15 mm qp 0.6m³/h up to DN 100 mm qp 100m³/h 4 Extremely low power consumption enabling a long battery lifetime (up to 16 years) 4 Radio option integrated 4 Modular version, M-Bus, RS232, RS485, Analog outputs 4-20mA, pulse outputs and pulse inputs

GENERAL Application Heating - heating with cooling tariff Approval MID (DE-10-MI004-PTB013) Mounting position flow sensor Any position, calming sections not necessary Protection class flow sensor Heating: IP 54; heating with cooling tariff: IP 65 Battery supply 3.6 VDC- D-cell up to 16 years lifetime Mains supply 24 VAC (50-60 Hz); 230 VAC (50-60 Hz) Temperature sensor type Pt 500 with 2-wire leads; Ø 5.2 mm or direct sensor Cable length of temperature sensor Pt 500: 2 / 3 / 5 / 10m Absolute temperature range calculator Θ C 1... 180 Volume measuring cycle With power supply: ⅛ s; with D-cell battery: 1 s Material of the flow sensor body Brass or grey cast iron (only q p 15 m³/h up to q p 100 m³/h) Test possibilities Via display, optical test pulses, test output or via NOWA software CALCULATOR - BASIC FEATURES Environmental class (EN 1434) Class C Ambient class (MID) Class E2 + M2 Ambient operating temperature C +5... +55 Ambient storage temperature C -25... +60 (>35 C max. 4 weeks) Protection class IP 54 Communication Integrated Radio Optional Interfaces standard Optical ZVEI interface Interfaces optional 3 communication slots (e. g. M-Bus + M-Bus + integrated radio; 2 primary addresses, 1 secondary address) Temperature range heating C +5... +130 / +150 (depends on meter size) Temperature range heating/ cooling meter C +5... +105 Extensive readable data memory Periodical log 1 ; history log; event memory 1 : Programmable storage interval (daily, weekly, monthly,...) 2 Slots for modules with M-Bus, L-Bus, RS232, RS485, pulse output, pulse input, combined pulse in-/output or analogue output CALCULATOR - INTEGRATED RADIO Frequency band 868 or 434 MHz Type of radio telegram Real Data or Open Metering Standard (OMS) Transmission data updating Online - no time delay between value measurement and data transmission Data transmission Unidirectional Sending interval 12 s (up to 16 years lifetime); depending on length of telegram (duty cycle) DISPLAY Display indication LCD, 8-digit Units MWh - kwh - GJ - Gcal - MBtu - gal - GPM - C - F - m³ - m³/h Total values 99,999,999-9,999,999.9-999,999.99-99,999.999 (depending of the nominal diameter) Values displayed Energy - Power - Volume - Flow rate - Temperature 02.12.2014 2

INTERFACES Optical ZVEI interface, for communication and testing, M-Bus protocol. M-Bus L-Bus RS232 RS485 Pulse output Pulse input Combined pulse in-/output Analogue output 1 : only with DIEHL support TEMPERATURE INPUT Configurable telegram, according to EN13757-3, data reading and parametrization are via two wires with polarity reversal protection, auto baud detect (300 and 2400 baud), 2 M-Bus with 2 primary adresses. Adapter for external radio module, configurable telegram, according to EN13757-3, data reading and parametrization are via two wires with polarity reversal protection. Serial interface for communication with external devices, a special data cable is required, M- Bus protocol, 300 and 2400 baud. Serial interface for communication with external devices, power supply with 12 V ± 5 V, M- Bus protocol, 2400 baud. Module with 2 Open Collector pulse outputs (potential-free), output 1: 4 Hz (pulse width 125 ms) pulse or static conditions (e.g. errors); output 2: 100 Hz (pulse width 5 ms), ratio: pulse duration / pulse break ~ 1:1, configurable via IZAR@SET software 1. Module with 2 pulse inputs, max. 20 Hz, configurable via IZAR@SET software 1, data can be transferred remotely. Module with 2 pulse inputs and 1 pulse output, configurable via IZAR@SET software 1, needed for leak detection. Module for 4... 20 ma with 2 programmable passive outputs, programmable value in case of error. Measuring cycle T s With mains supply: 2 s; with D-cell battery: 4 s Starting temperature difference ΔΘ K 0.125 Min. temperature difference ΔΘ min K 3 Max. temperature difference ΔΘ max K 177 02.12.2014 3

TECHNICAL DATA FLOW SENSOR Nominal flow rate q p m 3 /h 0.6 1.5 1.5 2.5 6 6 Nominal diameter DN mm 15 15 20 20 25 32 Overall length L mm 110 110 130 130 260 260 Starting flow rate l/h 1 2.5 2.5 4 7 7 Minimum flow rate q i l/h 6 6 1 6 1 10 1 24 1 24 1 Maximum flow rate q s m 3 /h 1.2 3 3 5 12 12 Overload flow rate m 3 /h 2.5 4.6 4.6 6.7 18.4 18.4 Operating pressure PN bar 16/25 16/25 16/25 16/25 16/25 16/25 Pressure loss at q p Δp mbar 85 75 75 100 128 128 Temp. range heating C 5... 130 5... 130 5... 130 5... 130 5... 150 5... 150 Kvs value (Δp=Q 2 /Kvs 2 ) 2.06 5.48 5.48 7.91 16.77 16.77 Nominal flow rate q p m 3 /h 10 15 25 40 60 100 Nominal diameter DN mm 40 50 65 80 100 100 Overall length L mm 300 270 300 300 360 360 Starting flow rate l/h 20 40 50 80 120 120 Minimum flow rate q i l/h 40 1,2 60 1,2 100 1,2 160 1 240 1,2 240 2 Maximum flow rate q s m 3 /h 20 30 50 80 120 120 Overload flow rate m 3 /h 24 36 60 90 132 132 Operating pressure PN bar 16/25 16/25 16/25 16/25 16/25 16/25 Pressure loss at q p Δp mbar 95 80 75 80 75 75 Temp. range heating C 5... 150 5... 150 5... 150 5... 150 5... 150 5... 150 Kvs value (Δp=Q 2 /Kvs 2 ) 32.44 53.03 91.29 141.42 219.09 219.09 1 : For a dynamic range of 1:250 2 : Only for horizontal installation 02.12.2014 4

DIMENSIONS THREAD VERSION Nominal flow rate q p m 3 /h 0.6 1.5 1.5 2.5 6 6 Nominal diameter DN mm 15 15 20 20 25 32 Overall length L mm 110 110 130 130 260 260 Overall length with coupling L2 mm 190 190 230 230 380 380 Length of calculator L1 mm 150 150 150 150 150 150 Height H mm 14.5 14.5 18 18 23 23 Height H1 mm 82 82 84 84 88.5 88.5 Height of calculator H2 mm 54 54 54 54 54 54 Width of calculator B mm 100 100 100 100 100 100 Connection thread on meter Inch G¾B G¾B G1B G1B G1¼B G1½B Connection thread of coupling Inch R½ R½ R¾ R¾ R1 R1¼ Weight kg 0.76 0.76 0.85 0.85 1.5 1.5 Nominal flow rate q p m 3 /h 10 15 25 40 60 100 Nominal diameter DN mm 40 50 65 80 100 100 Overall length L mm 300 270 300 300 360 360 Overall length with coupling L2 mm 440 - - - - - Length of calculator L1 mm 150 - - - - - Height H mm 33 - - - - - Height H1 mm 94 - - - - - Height of calculator H2 mm 54 - - - - - Width of calculator B mm 100 - - - - - Connection thread on meter Inch G2B - - - - - Connection thread of coupling Inch R1½ - - - - - Weight kg 3.1 - - - - - 02.12.2014 5

DIMENSIONS FLANGE VERSION Nominal flow rate q p m 3 /h 0.6 1.5 1.5 2.5 6 6 Nominal diameter DN mm 15 15 20 20 25 32 Overall length L mm 110 110 130 130 260 260 Length of calculator L1 mm - - - - 150 150 Height H mm - - - - 50 62.5 Height H1 mm - - - - 88.5 88.5 Height of calculator H2 mm - - - - 54 54 Width of calculator B mm - - - - 100 100 Flange dimension F mm - - - - 100 125 Flange diameter D mm - - - - 114 139 Hole circle diameter K mm - - - - 85 100 Screwhole diameter D1 mm - - - - 14 18 Number of screwholes pcs - - - - 4 4 Weight brass body kg - - - - 3.5 4.8 Weight grey cast iron body kg - - - - - - Nominal flow rate q p m 3 /h 10 15 25 40 60 100 Nominal diameter DN mm 40 50 65 80 100 100 Overall length L mm 300 270 300 300 360 360 Length of calculator L1 mm 150 150 150 150 150 150 Height H mm 69 73.5 85 92.5 108 108 Height H1 mm 94 99 106.5 114 119 119 Height of calculator H2 mm 54 54 54 54 54 54 Width of calculator B mm 100 100 100 100 100 100 Flange dimension F mm 138 147 170 185 216 216 Flange diameter D mm 148 163 184 200 235 235 Hole circle diameter K mm 110 125 145 160 180 1 /190 180 1 /190 Screwhole diameter D1 mm 18 18 18 19 19 1 /22 19 1 /22 Number of screwholes pcs 4 4 8 8 8 8 Weight brass body kg 6.4 7.0 8.9 10.9 16.4 16.4 Weight grey cast iron body kg - 5.9 7.7 9.6 15.2 15.2 1 : Value for PN 16 housing 02.12.2014 6

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 02.12.2014 7