PP-9213 Pre Amplifier

Similar documents
PAM-240/360 Public Address Amplifier

PA-2312 Public Address 2 CH Power Amplifier

Welcome Warning...1 Unpacking...2. Installation Environment...2 Important Safety Instructions...2. Features...3 Accessories...3

VCA-100 Wall Volume Controller

L800/1400/1800/2400 Professional Power Amplifier

PT-9107S Stereo Tuner

Operation Manual. Public Address Amplifier MA-106

Operation Manual. Pre Amplifier PP-6214

R150 PLUS/300 PLUS/500 PLUS Reference Amplifier

H-3200/4200 Professional Power Amplifier OFF

PP-9214 Pre Amplifier

Operation Manual PA-6312/6324/6336/6348. Public Address Power Amplifier

PA-9312/9324/9336 Public Address Power Amplifier

Operation Manual PA-9312/9324/9336/9348. Public Address Power Amplifier

A-60/120 Public Address Amplifier

PT-9107SD Stereo Tuner

Operation Manual. Digital Amplifier MA-110/110N

PT-9107SD Stereo Tuner

PAM-240A/360A Public Address Amplifier

Operation Manual. Professional Power Amplifier V2-1000/2000/3000/4000

RM-05A Remote Amp with Zone Selector

Operation Manual. Public Address Amplifier PAM-120A/340A/480A

Inter-M, Ltd. (Korea) began operations in 1983.

Operation Manual. Digital Amplifier MA-103

Operation Manual. Mixing Amplifier PA-360/480/600

Operation Manual FTA-108S/ITX-108/ITX /8 Channel Audio Transmitter/Receiver. Transmitter: Receiver: FRA-108S/IRX-108/IRX-102

Operation Manual. Dual 31-Band Graphic Equalizer EQ-2231A

Inter-M, Ltd. (Korea) began operations in 1983.

EQ-2131/2231/2215 Graphic Equalizer

AMPLIFIER QD-4240/4480

PAT-20TB MOBILE PUBLIC ADDRESS AMPLIFIER WITH TALK BACK SYSTEM

L800/1400/1800/2400/3000 Professional Power Amplifier

Operation Manual. Mixing Amplifier PA-60/120/240

Operation Manual QD-4240/4480/4960 QX Quad Amplifier

MC58 Eight Channel Power Amplifier

User Manual. MA 240 Mixing amplifier

Operation Manual TP-6231A. Telephone Paging

User Manual. imix 63 Stereo mixing preamplifier

ST-3103 ST-3108 ASW-138 ST-20 ASW-158 ST-20 SPEAKER SYSTEM

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions

ZM-6. Professional 19 Rack Mixer USER MANUAL. Content

POWERED MIXER DIGITAL ECHO EFFECT ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO VOL REPEAT MPM CHANNEL POWERED MIXER OWNER S MANUAL

WX-1 & WX-3 OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier. WX-1 and WX-3.indd :23:16

User Manual. MA 21 Two zone mixing amplifier

Model CC4041. CC Series Amplifier. Installation and Use Manual

3.Avoid spilling liquids or allowing materials to enter the cabinet

Big Bang. B B O w n e r s M a n u a l. Power Amplifiers. SpeakerCraft BB2125 POWER ACTIVE PROTECTION L

INSTRUCTION MANUAL POWERED MIXER MX-628

User Manual. ia480x Power amplifier

Model CC4052. CC Series Amplifier. Installation and Use Manual

Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM. Model KD-1. Toa Electric Co., Ltd. KOBE, JAPAN

M-300 Mono power amplifier User s guide

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

H A 6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

LA-SERIES LOOP AMPLIFIERS. Item ref: UK, UK User Manual

CABINET POWERED MIXING CONSOLE

STEREO TUBE POWER AMPLIFIER

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

DA216S DISTRIBUTION AMPLIFIER

DSR-3. Bedienungsanleitung User Guide

IMPORTANT SAFETY INSTRUCTIONS

PM7400MKII. Instruction manual

3400 Watt Stereo Power Amplifier

MIC MECHANIC 2. Ultra-Simple Battery-Powered Vocal Effects Stompbox with Echo, Reverb and Pitch Correction. User Manual

REVAMP2250 Instruction manual

TOA 500 SERIES MIXER POWER AMPLIFIER

Integrated mixer amplifier PA-60/120/240

mix 502, mix 802, mix 1202FX mixer user manual

HTA125A/250A. Power Amplifiers. Installation & Use Manual

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide

User Manual TUBE CONDENSER MICROPHONE T-1. Vacuum Tube Condenser Microphone

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

HARMONY SINGER 2. Battery-Powered Vocal Effects Stompbox with Guitar-Controlled Harmony, Reverb and Tone. User Manual

!!! WARNING!!! TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

arthur ART48 - YELLOW ACOUSTIC FIDELITY USER MANUAL Assembling instruction on ART48-L/Rmast manual

REVAMP4100 Instruction manual

SA 125 mixer amplifier. user manual

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide

Classic Series Public Address Amplifiers C10 & C20 Models

GUITAR POWER AMPLIFIER U S E R ' S M A N U A L

SR Series Crossovers. Owner s Manual SR 823 SR 834. A Harman International Company

plifier D-501 otion Am Tactile M

REVAMP4120T Instruction manual

MC1000 POWER AMPLIFIER

Operation Manual. Mixing Amplifier PMU-60N/120N/240N

Primare A33.2 Amplifier User Guide

IPA 2300 Power Amplifer Owner s Manual

American Audio. User Instructions. American Audio 4295 Charter Strret Los Angeles Ca Revised 5/01

IMPORTANT SAFETY INSTRUCTIONS

EX WATT POWERED SUBWOOFER OWNERS MANUAL SAMSON

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

PROFESSIONAL FOUR-CHANNEL AUDIO MIXER WITH DSP PROCESSOR

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

HOOKING IT UP. Unpacking and Inspection. Installing in a Rack CHAPTER 3: Hooking It Up

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA

Transcription:

PP-923 Pre Amplifier CH CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 INPUTS MASTER OUTPUTS PEAK -6-6 -6-6 AUX AUX2 - POWER ON PRIORITY - 6 SUB OFF PRIORITY2 SUB2 6 MASTER * Rack mount products in the Western Hemisphere(North America, South America, and the Caribbean) do not have handles installed due to customer preference.

Contents. Unpacking and Installation... 2. Features...2 3. Front Panel Controls...3 4. Rear Panel Controls...5 5. Connections...7 6. Block Diagram...8 7. Specifications...9 OFFICE : 653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA TEL : 82-2-2289-84~8, FAX : 82-2-2289-844 Home Page : http://www.inter-m.com E-mail : export@inter-m.com

Unpacking and Installation Although it is neither complicated to install nor difficult to operate your Pre Amplifier, a few minutes of your time is required to read this manual for a properly wired installation and becoming familiar with its many features and how to use them. Please take a great care in unpacking your set and do not discard the carton and other packing materials. They may be needed when moving your set and are required if it ever becomes necessary to return your set for service. Never place the unit near radiators, in front of heating vents, excessive humid or dusty location to avoid early damage and for your years of quality use. Connect your complementary components as illustrated in the following page. Do not install this equipment in a confined space such as a book case or similar unit. The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. Caution: This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance. To prevent electric shock do not use this (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure. WARNING To prevent fire or shock hazard, do not expose the unit to rain or moisture. Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert. PP-923

Features - Low, Mid, High and Trim controls on each channel. - 2 Channel Aux inputs. - 2 Auto Ducking Priority inputs. - 4 Band (Low, Low-mid, Hi-mid and High) EQ on master channel. - Master output, 2 Sub output and Recording output. - 2 Ducking channels. (channel, 2) - Signal and Peak indicators on each channel. - 2 Channel Phantom powers. - DC power operation. 2 PP-923

Front Panel Controls 2 3 4 5 6 7 CH CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 INPUTS MASTER OUTPUTS PEAK -6-6 -6-6 AUX AUX2 - POWER ON PRIORITY - SUB 6 OFF PRIORITY2 SUB2 6 MASTER PP 923 PRE AMPLIFIER 8 9 2. CONTROL This control adjusts the input sensitivity of each channel from -6dB to -6dB for microphone source, and from +24dB to -2dB for line source. For the best performance, adjust this control so that PEAK indicator LED lights occasionally. 2. SIGNAL INDICATOR LED indicates that a signal is present at the channel input. 3. PEAK INDICATOR This warning light indicates an overload situation. This indicator light in red when the post EQ, or pre fader signal of the corresponding channel s input reaches a level 3dB below the clipping level. 4. CHANNEL FADER This is the main level control for each input channel. It determines level of the signal sent from the corresponding input channel to the master mixing buss. Faders of channels not in use should be pulled down. 5. AUX CONTROLS These controls adjust the level of the Aux signals that are received at the rear panel AUX, 2. 6. MASTER PEAK INDICATOR This warning light indicates an overload situation. This indicator light in red when the post fader signal of the corresponding Master output reaches a level 3dB below the clipping level. 7. MASTER OUTPUT FADER The master faders independently adjust level of the master mixing buss signals appearing at the MASTER OUT connectors. PP-923 3

8. EQ CONTROLS OF INPUT CHANNEL Each input channel equalizer is divided into three band. This level is adjustable over a wide range of boost and cut. GH: ±2dB at khz : ±2dB at khz : ±2dB at Hz 9. PRIORITY CONTROLS These controls adjust the level of the Priority signals that are received at the rear panel PRIORITY, 2.. EQ CONTROLS OF MASTER Master output channel equalizer is divided into four band. This level is adjustable over a wide range of boost and cut. GH: ±2dB at khz -: ±2dB at 2kHz -: ±2dB at 4Hz : ±2db at 8Hz. SUB OUTPUT CONTROLS This control adjusts the level of the signal output from the SUB OUT. 2. POWER SWITCH Pressing this switches to on the power is supplied to this unit. 4 PP-923

Rear Panel Controls 2 3 4 5 S N OC3 2 2 2 ~AC INPUT 23V 5Hz W MASTER OUTPUT SUB OUT PRIORITY INPUT AUX INPUT L L L FUSE T25mAL/ 25V REC OUT INSERT - + DC INPUT 24V R CH9 R CH8 R CH7 CH6 CH5 CH4 CH3 DUCK CH2 P.PWR DUCK CH P.PWR 6 7 8 9 2 3. MASTER OUTPUT This is XLR type connector used to connect a power amplifier. (Pin assignment : GND, 2: HOT, 3: COLD) 2. SUB OUTPUTS These are phone type connectors used to connect another amplifier. 3. PRIORITY INPUT JACKS This inputs are unbalanced line level input with phone jacks. All other channels are controlled by the signal of priority inputs with Automatic ducking operation. 4. AUX INPUT JACKS This inputs are unbalanced line level input with phone jacks. 5. These XLR type connectors be connected with microphone. (Pin assignment : GND, 2: HOT, 3: COLD) Impedance range is 5Ω to 6Ω. Turn the phantom power switch ON to apply +8V DC to pin 2 and 3 of these connectors. (MIC and MIC2) 6. AC POWER ENTRY MODULE An inlet socket to connect the power cable and fuse holder. A correct capacity of fuse should be applied. Please make sure the value of fuse before replacing. 7. REC OUTPUT This phone jack is unbalanced outputs for use with tape recorder. PP-923 5

8. INSERT JACK Whenever a plug is inserted into INSERT jack, the master mixing buss is disconnected from the Master output stage. The Master output is direct connected to INSERT jack. 9. DC POWER TERMINAL A terminal to connect the DC24V output terminal of power distributor unit. (PD-92 or PD-9359). STEREO These are Unbalanced Stereo input connector which can be connected line level equipment.. MONO These are balanced input connector which can be connected line level equipment. 2. DUCKING SWITCH When the ducking is on, the set will automatically lower the gain of other channel inputs when someone is speaking into one of the microphones. 3. PHANTOM POWER SWITCH This switch turns on and off the phantom power supply. The phantom power supply provides power for condenser type microphone through the microphone cable. When switched on, it produces 8 volts DC (with 6.8kΩ source impedance) at pins 2 and 3 on CH, CH2 microphone input connectors. Pin (the shield conductor) provides the ground return path. This will power standard condenser microphones and will not affect most dynamic microphones. When switched on or off, the voltage will ramp slowly up or down; it takes a few seconds to reach full level. This prevents unwanted transients from reaching the microphone inputs. 6 PP-923

Connections S N OC3 2 2 2 ~AC INPUT 23V 5Hz W MASTER OUTPUT SUB OUT PRIORITY INPUT AUX INPUT L L L FUSE T25mAL/ 25V REC OUT INSERT - + DC INPUT 24V R CH9 R CH8 R CH7 CH6 CH5 CH4 CH3 DUCK P.PWR DUCK P.PWR CH2 CH EMERGENCY PANEL FIRE MICROPHONE DISTRIBUTOR MICROPHONE POWER AMPLIFIER CASSETTE DECK CD PLAYER TUNER SPEAKERS KEY BOARD PP-923 7

Block Diagram 2 8 PP-923

Specifications...dB=.775Vrms - ELECTRICAL OUTPUTS Master Output...+4dBm/6Ω, BALANCED Sub, 2 Output...+4dBm/6Ω, UNBALANCED Rec Output... dbv/kω, UNBALANCED INPUTS Mic (CH~CH9)... 6dBm/6Ω, BALANCED Line (CH~CH6)... 2dBm/47kΩ, BALANCED Line (CH7~CH9)... 2dBm/47kΩ, UNBALANCED Aux, 2... dbm/2kω, UNBALANCED Priority, 2...dBm/2kΩ, UNBALANCED Insert...dBm/2kΩ, UNBALANCED T.H.D...Less than.3% Frequency Response...3Hz~2kHz (+d, 3dB) INPUT Channel EQ High (khz)...±2db Mid (khz)...±2db Low (Hz)...±2dB OUTPUT EQ High (khz)...±2db Hi-Mid (2kHz)...±2dB Low-Mid (4Hz)...±2dB Low (8Hz)...±2dB Residual Noise...Less than 9dB Crosstalk...Less than 6dB Phantom Power...+8V DC - GENERAL Power Source...AC 2V, 23V, 24V, 5/6Hz, DC 24V Power Consumption...W Weight...7.5kg Dimensions...482(W) 88(H) 28(D)mm * Specifications and design subject to change without notice for improvements. PP-923 9

Inter-M, Ltd. (Korea) began operations in 983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM). The company is no longer just a Korean company, but rather a global company that is truly international in scope, with factories and offices in Korea and China, and sales and marketing operations located in Japan, Europe, and the U.S.A. With more than 85 employees around the globe, Inter-M is well-poised for further growth and expansion. INTER-M AMERICAS, INC. EAST BEACON LIGHT LANE CHESTER, PA USA 93-449 TEL : -6-874-887, FAX : -6-874-889 Home Page : http://www.inter-m.net, E-mail : service@inter-m.net INTER-M Corporation SEOUL OFFICE:653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA TEL : 82-2-2289-84~8, FAX : 82-2-2289-849 Home Page : http://www.inter-m.com, E-mail : export@inter-m.com MADE IN KOREA December 25 97983 A