Wave Inspector Navigation and Search: Simplifying Waveform Analysis APPLICATION NOTE

Similar documents
Wave Inspector Navigation and Search: Simplifying Waveform Analysis

Wave Inspector Navigation and Search: Simplifying Waveform Analysis. Introduction. Application Note

How to Troubleshoot System Problems Using an Oscilloscope with I 2 C and SPI Decoding

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Visual Triggering. Technical Brief

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Measuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

KickStart Instrument Control Software Datasheet

Measuring Power Supply Switching Loss with an Oscilloscope

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

Isolation Addresses Common Sources of Differential Measurement Error

Digital Debug With Oscilloscopes Lab Experiment

Be Sure to Capture the Complete Picture

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Power Measurement and Analysis Software

Replicating Real World Signals with an Arbitrary/Function Generator

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

If I Could... Imagine Perfect Vision

MDO4000B Series Mixed Domain Oscilloscope. Product Selection and Comparison Guide

100GBASE-KR4/CR4 & CAUI-4 Compliance and Characterization Solution

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

S540 Power Semiconductor Test System Datasheet

Low Cost RF Sensors. application note

AC/DC Current Probe TCP0150 Datasheet

Measuring Wireless Power Charging Systems for Portable Electronics

Advanced Statistical Analysis Using Waveform Database Acquisition

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope

Using the Ramp Rate Method for Making Quasistatic C-V Measurements with the 4200A-SCS Parameter Analyzer APPLICATION NOTE

10 FACTORS IN CHOOSING A BASIC OSCILLOSCOPE

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

Automotive EMI/EMC Pre-compliance Tests

Measurement Statistics, Histograms and Trend Plot Analysis Modes

20X Low Capacitance Probe P6158 Datasheet

Low Capacitance Probes Minimize Impact on Circuit Operation

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Programmable Pulse/Pattern Generator PSPL1P601 and PSPL1P602 Datasheet

100GBASE-KR4, 100GBASE-CR4, & CAUI-4 Compliance and Characterization Solution for Real Time Scopes

30 A AC/DC Current Probe TCP0030A Datasheet

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Passive Voltage Probes

12.5 Gb/s PatternPro Programmable Pattern Generator PPG1251 Series Datasheet

S540 Power Semiconductor Test System Datasheet

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

Soldering a P7500 to a Nexus DDR Component Interposer

Stress Calibration for Jitter >1UI A Practical Method

10 GHz Linear Amplifier PSPL5866 Datasheet

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

1.5 GHz Active Probe TAP1500 Datasheet

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

AC Current Probes CT1 CT2 CT6 Data Sheet

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

High-voltage Differential Probes

Using the 4200A-CVIV Multi-Switch to Make High Voltage and High Current C-V Measurements APPLICATION NOTE

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

Tektronix Logic Analyzer Probes P6800/P6900 Series Datasheet

30 Gb/s and 32 Gb/s Programmable Pattern Generator PPG Series Datasheet

Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet

Time and Frequency Measurements for Oscillator Manufacturers

P7500 Series Probes Tip Selection, Rework and Soldering Guide

Testing with Versatile Pulse Generation Solutions

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

16 Gb/s, 30 Gb/s, and 32 Gb/s PatternPro Pattern Generator PPG1600, PPG3000, and PPG3200 Series Datasheet Notice to EU customers

P7600 Series TriMode Probes

Switching Between C-V and I-V Measurements Using the 4200A-CVIV Multi-Switch and 4200A-SCS Parameter Analyzer APPLICATION NOTE

Differential Probes P6248 P6247 P6246 Datasheet

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

Active Power Factor Correction Verification Measurements with an Oscilloscope APPLICATION NOTE

16 Gb/s, 30 Gb/s Gb/s, and 32 Gb/s Programmable PatternPro Pattern Generator PPG PPG1600, PPG3000, and PPG3200 Series Datasheet Key features

TriMode Probe Family P7700 Series TriMode Probes

High-impedance Buffer Amplifier System

10GBASE-KR/KR4 Compliance and Debug Solution

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

DPO7OE1 33 GHz Optical Probe

Z-Active Differential Probe Family P7313 P7380A P7360A P7340A Datasheet

GENERAL PURPOSE POWER SUPPLIES, SPECIAL PURPOSE POWER SUPPLIES, AND ELECTRONIC LOADS SELECTOR GUIDE

50MHz arbitrary waveform/function generator

Advanced Test Equipment Rentals ATEC (2832)

12.5 Gb/s Driver Amplifier PSPL5865 Datasheet

Choosing an Oscilloscope for Coherent Optical Modulation Analysis

TriMode Probe Family. P7500 Series Data Sheet. Features & Benefits. Applications

Arbitrary Function Generator AFG1022 Datasheet

Arbitrary/Function Generator AFG1000 Series Datasheet

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

Keysight Technologies Triggering on and Decoding the PSI5 Sensor Serial Bus

MIL-STD 1553 Triggering and Hardwarebased Decode (Option 553) for Agilent s InfiniiVision Series Oscilloscopes

Fundamentals of AC Power Measurements

Arbitrary Function Generator AFG1000 Series Datasheet

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Passive High Voltage Probes P5100 P5102 P5120 P6015A

Creating Calibrated UWB WiMedia Signals

Transcription:

Wave Inspector Navigation and Search: Simplifying Waveform Analysis APPLICATION NOTE

Application Note Wave Inspector Controls Figure 1. Wave Inspector provides dedicated front-panel controls for efficient waveform analysis. Introduction As Moore s Law pushes electronic technology faster, system designs continue to become more complex, and subsequently harder to design, build, troubleshoot, and fix when they break. So what does this mean to modern oscilloscopes? As designs become faster and more complex, the need for long records, more bandwidth, and higher sampling rate will also increase. Record length is the number of samples an oscilloscope can digitize and store in a single acquisition. The longer the record length, the longer the time window the oscilloscope can capture with high timing resolution (high sample rate). The record length required for a specific application is directly affected by the bandwidth and sample rate. As bandwidth goes up, the sampling rate must be approximately five times higher to accurately capture the signal s high frequency content. As the sampling rate goes up, a given time window of signal acquisition requires more samples. For example, to capture 2 milliseconds of a 100 MHz signal at 5 GS/s requires a 10 million point record. (Divide 2 milliseconds by the 200 picosecond sample interval.) Even at lower frequencies, there are many applications that require long records. Just capturing a single frame of NTSC video (two fields in a 1/30th of a second interval, at 100 MS/s to resolve all the luminance information) requires over 3 million points (33 milliseconds divided by 10 nanoseconds). Capturing several seconds of bus traffic on a 1 Mb/s CAN bus to diagnose problems in an electromechanical system may require 10 million points for adequate resolution. These and a variety of other applications have driven and continue to drive the need for longer and more detailed data capture windows. Analyzing all that Data The first digital oscilloscopes had very short record length. As such, it was easy to see everything the oscilloscope captured because it was all on the screen at one time. As oscilloscopes evolved and records got longer, horizontal scrolling was used to see all the data. This was not a big issue as you move from one screen s worth of information to two, then up to four, eight, twenty, etc. However, as records became longer and longer with each generation of oscilloscope, the time required to look through all the data captured in a single acquisition grew longer and longer. We are now dealing with record lengths in the millions of points that represent thousands of screens worth of signal activity. By way of comparison, imagine trying to find what you re looking for on the Internet without the assistance of your favorite search engine, web browser, or bookmarks. It would be like searching for a needle in a haystack. Until recently, this is what oscilloscope users faced with their long record length oscilloscopes. Clearly, the old solutions will no longer work. 2 www.tektronix.com/oscilloscopes

Wave Inspector Navigation and Search: Simplifying Waveform Analysis Zoom Figure 2. Navigating through a long acquisition of an I 2 C bus. Figure 1A. Wave Inspector provides dedicated front-panel zoom and pan controls. Wave Inspector Navigation and Search Available on the 5 Series MSO, MSO/DPO5000, MDO4000, MDO3000, and MSO/DPO2000 Series oscilloscopes, Wave Inspector controls make working with long records and extracting the answers you need from your waveforms a simple and efficient process. Zoom / Pan Most digital oscilloscopes on the market today offer some form of zoom capability. However, the controls associated with the zoom view (zoom factor and position) are often buried in menus or multiplexed with other front-panel controls. For example, the zoom window s horizontal position is typically controlled by the horizontal position knob on the front panel. Once you ve zoomed in on an event of interest, if you want to move the zoom window to another location in the acquisition it typically means either turning the horizontal position knob countless times to slowly move the window to the new location, or zooming back out, adjusting the window s location and then zooming back in. Neither approach is efficient nor intuitive. It becomes even less efficient when you have to navigate through menus just to access these basic zoom controls. As shown in Figure 1A, Wave Inspector provides a dedicated two-tier front-panel Zoom / Pan knob for efficient waveform navigation. The inner knob controls the zoom factor. The farther clockwise you turn it, the farther you zoom in. Turning it counter-clockwise zooms back out and ultimately turns zoom off. The outer ring is a force/rate sensitive pan control. Turning it clockwise pans the zoom window right on the waveform, counterclockwise pans it left. The farther you turn it, the faster the zoom window moves across the waveform. In Figure 2, we can quickly navigate from one packet to the next by simply turning the pan control in the desired direction. Even with a 10 million point acquisition, you can rapidly move the zoom window from one end of the record to the other in a few seconds, without ever having to change your zoom factor. In Figure 2 we re probing an I 2 C bus. The complete acquisition is shown in the upper window and the zoomed portion is in the lower, larger window. In this case, we ve zoomed in to view the decoded address and data values for one particular packet. www.tektronix.com/oscilloscopes 3

Application Note Play / Pause Many times when debugging a problem, you don t know what s causing the problem so you re not sure what to look for in the waveform you ve acquired. However, you know you ve captured the time window that contained the problem and you now need to look through the data you ve captured to see if you can find the issue. Again, on most modern oscilloscopes this is done by manually turning the horizontal position knob countless times to inspect the acquired waveforms for any suspicious activity. Wave Inspector controls help in this area as well. You can simply press the Play button on the front panel to have your zoom window automatically pan across the waveform. Play speed and direction are adjusted using the intuitive pan control. The farther you turn the pan control the faster the waveform plays by. This allows hands-free playback so you can concentrate on what s important the waveform itself. In the I 2 C example (Figure 2), you could play the waveform while watching the decoded address and data values to monitor activity on the bus. When you spot the event you re looking for simply press the Play/Pause button again to stop the waveform. Play/Pause Figure 2A. Dedicated front-panel control for automated waveform playback. 4 www.tektronix.com/oscilloscopes

Wave Inspector Navigation and Search: Simplifying Waveform Analysis Set/Clear Marks Figure 3. Placing marks on the waveform to assist in latency measurements on a CAN bus. Figure 2B. Dedicated front-panel controls for setting/clearing marks and navigating between them. Marks While looking for the source of the problem, you may find numerous areas of the waveform that either warrant further investigation or are indicative of something happening in the device under test that you want to use as a reference point during the rest of your analysis. For example, assume you need to make timing measurements associated with the latency from when a driver presses the Passenger Window Down switch on the driver s door panel to when the passenger window actually starts to move. The first event you ll want to find in the acquisition is when the switch was pressed. The next may be when the CAN module in the driver s side door issues the command to the CAN module in the passenger door. The last event may be when the motor engaged in the passenger door and the window started to move. Wouldn t it be nice to mark each of these locations on the waveform so you can quickly jump back and forth between the areas of interest for timing measurements? With the Tektronix Wave Inspector Navigation Series you can. In Figure 3, Channel 1 is the output of the switch in the driver s door, Channel 2 is the CAN bus, and Channel 3 is monitoring the motor drive in the passenger door. We ve set the oscilloscope up to trigger on the packet of interest by specifying the appropriate Identifier and Data. Next, we ve used the front-panel Set / Clear Mark button to mark each of the events of interest on the waveform. These user marks are shown as solid white triangles along the top edge in both the upper and lower windows. The rising edge on Channel 1 indicates when the switch was pressed. The trigger event is the CAN module in the driver s door issuing the command and the window beginning to move is the transition on Channel 3. Using the front-panel Previous and Next buttons we can instantly jump between marks to place cursors for quick and easy latency measurements. In Figure 3, we find that the total time from the press of the switch to window movement is 58.46 ms, well within the amount of acceptable delay. www.tektronix.com/oscilloscopes 5

Application Note Search & Mark In addition to placing marks on waveforms manually, Wave Inspector has the power to search through the entire acquisition and automatically mark every occurrence of a user-specified event. For example, imagine you are capturing laser pulses. The laser fires approximately every 20 µs, with each pulse being only 15 ns wide. You want to look at multiple pulses to characterize their shape and to make precise timing measurements between them, but to navigate from one to the next you need to sift through close to 20 µs of dead time. Then you need to repeat this for every other pulse in the acquisition. Clearly, it would be desirable to be able to move from pulse to pulse instantly without having to waste time twiddling a position knob. Search Function Previous Button Next Button Figure 3A. Wave Inspector s powerful Search capability allows you to find every occurrence of a user-specified event in the acquisition. 6 www.tektronix.com/oscilloscopes

Wave Inspector Navigation and Search: Simplifying Waveform Analysis Figure 4. Wave Inspector marking every pulse that crosses 300mV in a long acquisition. Figure 5. Setup & Hold violation search results in six occurrences found. A very simple search setup that looks for rising edges that cross a threshold of 300mV is illustrated in Figure 4. Marks generated by the search are shown as hollow white triangles along the top edge in both the upper and lower windows. This search resulted in 40 marks being placed throughout the record. Now all you have to do is press the front-panel previous and next buttons to jump from one pulse to the next, no adjustment of zoom scale or position is required! Wave Inspector s Search goes well beyond simple edge searches. Imagine the chip you re working with has an indeterminate output every so often that s causing the overall system to crash. You suspect that it s a metastability issue caused by Setup & Hold violations. In a matter of seconds, you can specify search criteria to have the oscilloscope automatically find every occurrence in the acquisition where setup and hold times you specify were violated. In this case, the part we re using has published setup and hold times of 12 ns and 4 ns, respectively. To have the oscilloscope automatically find violations of these limits, we simply need to tell it Clock is on Channel 1, Data is on Channel 2, set the thresholds, and enter the desired setup and hold times. The oscilloscope then checks the timing relative to every clock edge throughout the entire acquisition and marks the occurrences that violate the specified setup and hold times. In Figure 5, our search resulted in 13 violations. The 13 events are marked with hollow white triangles in the upper window. The lower window is showing a zoomed-in view of one of the violations. It s clear that the data line is transitioning within 4 ns of the positive clock edge. We ve found the metastability source without having to manually scroll through the waveform and without having to use cursors to measure anything. You can even perform worst case checks by adjusting the setup and hold times and seeing how many events Wave Inspector finds. For example, you can set the hold time to zero and then reduce the setup time until only one event is found. 1 Another powerful search capability provided by Wave Inspector is searching for data in a bus. You can use the front-panel bus buttons to define your signals as an I 2 C, SPI, USB, CAN, LIN, FlexRay, RS-232/422/485/UART, I 2 S/LJ/ RJ/TDM, Ethernet, MIL-STD-1553, or parallel bus. Then the oscilloscope will decode the bus into packets, displaying the information in a meaningful form. You can trigger on or search for data in the packets. (Requires optional applications or application modules.) 1 The MSO/DPO5000 Series supports search of setup & hold violations between clock and data on one other input channel. To further simplify waveform analysis, the 5 Series MSO, and the MDO4000, MDO3000, and MSO/DPO2000 Series oscilloscope support simultaneous search for setup & hold violations on all analog and digital input channels in the oscilloscope. www.tektronix.com/oscilloscopes 7

Application Note While this triggering is critical to isolate the time window that contains the problem, it s highly likely that you ll need to view bus activity over many packets to understand what s going on at a system level. The bus search feature enables you to specify packet level criteria and mark every occurrence of it in the record for quick viewing, navigation and analysis. Continuing the earlier CAN example, in Figure 6 we ve searched for every message in a long acquisition of a CAN bus with the specific Identifier (519) and Data (42) values we re interested in. Figure 6. Searching for specific Identifier and Data values in CAN messages. Wave Inspector found four messages in the acquisition that met the criteria. Again, moving the zoom window from one occurrence to the next is as simple as pressing the previous and next buttons on the front panel. And because the oscilloscope is decoding the packets for you, you can instantly see all the relevant information without having to manually decode from analog waveforms. In addition to the examples provided above, Wave Inspector can search for many other types of events. The full list of search capabilities is shown in Table 1. 8 www.tektronix.com/oscilloscopes

Wave Inspector Navigation and Search: Simplifying Waveform Analysis Search Type Edge Pulse Width Timeout Runt Logic Setup & Hold Rise / Fall Time Bus Description Searches for edges (rising, falling, or either) with a user-specified threshold level. Searches for positive or negative pulse widths that are >, <, =, or a user-specified pulse width. Timeout (5 Series MSO, MSO/DPO5000, MDO4000, and MDO3000 Series only): Search for an event which remains high, low, or either, for a specified time period. Searches for positive or negative pulses that cross one amplitude threshold but fail to cross a second threshold before crossing the first again. Search for all runt pulses or only those with duration >, <, =, or a user-specified time. Search for a logic pattern (AND, OR, NAND, or NOR) across multiple waveforms with each input set to either High, Low, or Don t Care. Search for when the event goes true, goes false or stays valid for >, <, =, or a user-specified time. Additionally, you can define one of the inputs as clock for synchronous (state) searches. Search for violations of user-specified Setup and Hold times. Search for rising and/or falling edges that are >, <, =, or a user-specified time. I 2 C: Search for Start, Repeated Start, Stop, Missing Ack, Address, Data or Address & Data. SPI: Search for SS Active, MOSI, MISO, or MOSI & MISO. USB (5 Series MSO, MSO/DPO5000, MDO4000, and MDO3000 Series only): Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet Handshake Packet, Special Packet, or Error. RS-232/422/485/UART: Search for Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error and Rx Parity Error. CAN: Search for Start of Frame, Type of Frame (Data, Remote, Error, Overload), Identifier (standard or extended), Data, Identifier & Data, End of Frame, or Missing Ack. LIN: Search for Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame or Errors such as Sync, Parity, or Checksum Errors. FlexRay (5 Series MSO, MSO/DPO5000, MDO4000, and MDO3000 Series only): Search for Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identifier, Cycle Count, Complete Header Field, Data, Identifier and Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame Errors. I 2 S/LJ/RJ/TDM (5 Series MSO, MDO4000, and MDO3000 Series only ): Search for Word Select, Frame Sync, or Data. 10BASE-T and 100BASE-TX Ethernet (5 Series MSO, MSO/DPO5000, and MDO4000 Series only): Search for Start Frame Delimiter, MAC Addresses, Q-Tag Control Information, MAC Length/Type, MAC Client Data, IP Header, TCP Header, TCP-IPv4 Client Data, End of Packet, Idle, or FCS (CRC) Error. MIL-STD-1553 (MSO/DPO5000, MDO4000, and MDO3000 Series only): Search for packet-level information. Parallel (5 Series MSO, MSO/DPO5000, MDO4000, MDO3000, and MSO2000 Series only): Search for data value. * Additional search types available for MSO/DPO5000 Series. Table 1. List of search events. www.tektronix.com/oscilloscopes 9

Application Note Figure 7. Search side menu. Multiple Searches An obvious question at this point is, What if I want to perform another search, but don t want to lose the results (marks) from my first search? Simply select the Convert Automatic Marks (hollow upside down triangle) to User Marks q menu selection and you ll see that the hollow white triangle search marks become filled in, appearing the same as marks placed with the front-panel Set Mark button. These marks are now saved on the waveform and a new search can be performed. You can do this as many times as you like, effectively creating unlimited searching ability. Of course, if you would like to start over with a clean slate you can press the Clear All Marks button to remove all marks from the waveform or you can remove any single mark using the Set/Clear Mark front-panel button. Search Interaction with Trigger Two other powerful and time-saving capabilities are included in the Search menu: the ability to copy trigger settings to search and copy search settings to trigger. Copying the current trigger settings to the search menu is most useful when you want to search through the acquisition to see if there are any other occurrences of the trigger event in the captured data. Alternatively, copying search settings to the trigger menu is most useful when you ve found an event in your data and you want to reacquire new data using that event as the trigger criteria. Wave Inspector with Advanced Search and Mark The MSO/DPO5000 Series offers extended search and mark capabilities by combining Wave Inspector with Advanced Search and Mark. The MSO/DPO5000 can simultaneously search for up to 8 different events. These products can also stop acquisitions when an event is found in the acquired signals, extending the products' hardware trigger capabilities with software triggering. Conclusion Modern digital oscilloscopes can capture massive amounts of data. Until now, searching through that data has been a time-consuming and frustrating process. With Tektronix Wave Inspector Navigation and Search, you can extract the answers you need with efficiency and precision and unlike any other oscilloscope. 10 www.tektronix.com/oscilloscopes

Wave Inspector Navigation and Search: Simplifying Waveform Analysis Wave Inspector Navigation and Search is available on the following oscilloscopes: Bandwidth 5 SERIES MSO MSO/DPO5000 SERIES MDO4000C SERIES MDO3000 SERIES MSO/DPO2000 SERIES 2 GHz, 1 GHz, 500 MHz, 350 MHz 2 GHz, 1 GHz, 2 GHz, 1 GHz, 500 MHz, 350 MHz 2 GHz, 1 GHz, 500 MHz, 350 MHz Analog Channels 4, 6, 8 500 MHz, 350 MHz 1 GHz, 500 MHz, 2 or 4 2 or 4 Digital Channels 8 to 64 (opt.) 350 MHz, 200 MHz 1 GHz, 500 MHz, 16 (opt.) 16 (MSO) Spectrum Analyzer Channels Record Length (All Channels) Sample Rate (Analog) -- 350 MHz, 200 MHz, 1 (opt.) 1 -- 62.5 M (std.) 125 M (opt.) 100 MHz 200 MHz, 100 MHz, 10 M 1 M Up to 6.25 GS/s 70 MHz Up to 5 GS/s Up to 5 GS/s 1 GS/s Color Display 15.6 in. HD 10.4 in. XGA 10.4 in. XGA 9 in. WVGA 7 in. WQVGA Optional Serial Bus Triggering and Analysis Applications I 2 C SPI RS-232/422/485/UART CAN LIN FlexRay USB 2.0 10/100BASE-T Ethernet I 2 S/LJ/RJ/TDM I 2 C SPI RS-232/422/485/UART CAN LIN FlexRay USB 2.0 10/100BASE-T Ethernet MIL-STD-1553 8b/10b decoding D-PHY MIPI decoding PCI Express decoding I 2 C SPI RS-232/422/485/UART CAN CAN FD LIN FlexRay USB 2.0 I 2 S/LJ/RJ/TDM MIL-STD-1553 I 2 C SPI RS-232/422/485/UART CAN CAN FD LIN FlexRay USB 2.0 I 2 S/LJ/RJ/TDM MIL-STD-1553 1 GHz, 500 MHz, 350 MHz, 200 MHz I 2 C SPI RS-232/422/485/UART CAN LIN www.tektronix.com/oscilloscopes 11

Contact Information: Australia* 1 800 709 465 Austria 00800 2255 4835 Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium* 00800 2255 4835 Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe / Baltics +41 52 675 3777 Central Europe / Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France* 00800 2255 4835 Germany* 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Indonesia 007 803 601 5249 Italy 00800 2255 4835 Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Malaysia 1 800 22 55835 Mexico, Central/South America and Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands* 00800 2255 4835 New Zealand 0800 800 238 Norway 800 16098 People s Republic of China 400 820 5835 Philippines 1 800 1601 0077 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea +82 2 6917 5000 Russia / CIS +7 (495) 6647564 Singapore 800 6011 473 South Africa +41 52 675 3777 Spain* 00800 2255 4835 Sweden* 00800 2255 4835 Switzerland* 00800 2255 4835 Taiwan 886 (2) 2656 6688 Thailand 1 800 011 931 United Kingdom / Ireland* 00800 2255 4835 USA 1 800 833 9200 Vietnam 12060128 * European toll-free number. If not accessible, call: +41 52 675 3777 Find more valuable resources at TEK.COM Copyright Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 04/17 EA 48W-19039-13